Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #58370991

Tender For Repair/Maint And Day To Day Complaint Of Internal Wiring/Fixture, Exhaust Fan/Ceiling Fan, Post Top Lantern, Bollard Light, Buildings Security Light, Flood Light And Misc E/M Items In Office Complex, W/S Installation & E/S Building Sub Stn

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
50 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
2 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint And Day To Day Complaint Of Internal Wiring/Fixture, Exhaust Fan/Ceiling Fan, Post Top Lantern, Bollard Light, Buildings Security Light, Flood Light And Misc E/M Items In Office Complex, W/S Installation & E/S Building Sub Stn Under Age(I) (U) B/R Delhi Cantt-10

BOQ

Name of Work:- Repair/maint and day to day complaint of internal wiring/fixture, exhaust fan/ceiling fan, post top lantern, bollard light, buildings security light, flood light and misc E/M items in office complex, W/S installation & E/S building sub stn under AGE(I) (U) B/R Delhi Cantt-10
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : AGE(I)(U)(B/R) Delhi Cantt-10 Name of Work : Repair/maint and day to day complaint of internal wiring/fixture, exhaust fan/ceiling fan, post top lantern, bollard light, buildings security light, flood light and misc E/M items in office complex, W/S installation & E/S building sub stn under AGE(I) (U) B/R Delhi Cantt-10 Contract No : AGE(I)(U) B/R-Token-45/2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engr-in-Charge.
3M&L for point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing modular switches , socket outlet and fan regulators etc , for the followings:- (a) One light/Fan/bell/Exhaust Fan/Fresh Air Fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
4All as per item No 2 above but for one multipin socket outlet 5 Amp on the same board with other switches complete all as specified and directed by Engr-in-Charge.
5All as per item No 2 above but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5 sqmm multistranded FRLS copper cable on the independent board complete all as specified and directed by Engr-in-Charge.
6All as per item No 2 above but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 2.5 sqmm multistranded FRLS copper cable, independent board complete all as specified and directed by Engr-in-Charge.
7Supply, laying and drawing in and including 20 mm dia pvc conduit pipe including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete all as specified and directed by Engr-in-Charge. Note:- Two run of 6.00 sqmm multistranded copper cable & one run of 6.00 sqmm copper cable as earth wire including pvc conduit will be measured as one unit length
8M&L for point wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for continous earthing in & incl pvc conduit pipe point wiring with accessories having ISI mark for one light/fan/bell point controlled by one switch complete all as specified and directed by Engr-in-Charge.
9All as per item No 7 here-in-before but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5 sqmm multistranded FRLS copper cable on the independent board complete all as specified and directed by Engr-in-Charge.
10All as per item No 7 here-in-before but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 2.5 sqmm multistranded FRLS copper cable, independent board complete all as specified and directed by Engr-in-Charge.
11M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed conduit, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing switches/sockets etc with cover plate/3mm thick plastic laminated sheet for one light/fan/fresh air/exhaust fan point complete all as specified and directed by Engr-in-Charge.
12All as per item No 10 above but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5 sqmm multistranded FRLS copper cable on the independent board complete all as specified and directed by Engr-in-Charge.
13All as per item No 10 above but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 2.5 sqmm multistranded FRLS copper cable, independent board complete all as specified and directed by Engr-in-Charge.
14All as per item 10 above but for one multipin socket outlet 5 Amp on the same board with other switches complete all as specified and directed by Engr-in-Charge.
15S&F of switch modular type single pole one way 5/6 Amps complete all as specified and directed by Engr-in-Charge.
16S&F of modular socket 5 pin multi purpose 5/6 Amps flush type complete all as specified and directed by Engr-in-Charge.
17S&F of modular socket multi purpose 2-in-1, 6 pin 6/16 Amps 2 module complete all as specified and directed by Engr-in-Charge.
18S&F of modular switch 16 Amps one module single pole one way complete all as specified and directed by Engr-in-Charge.
19S&F of modular ceiling fan regulator , step type for ceiling fan 120 w -2 module complete all as specified and directed by Engr-in-Charge.
20S&F in repair of electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers complete all as specified and directed by Engr-in-Charge.
21M&L for replacement of decorative city 3 walll light fixture made up of polycarbonate/mettalic texture as per site requirement ,suitable for Spiral B-22 Base including 9 watt LED Bulb complete all as specified and directed by Engr-in-Charge.
22S&F in replacement of angle Lamp holder,PVC /Polycarbonete type with back plate and metallic ring suitable for B 22 base complete all as specified and directed by Engr-in-Charge.
23S&F in replacement of rechargeable LED bulb of 9 watt ,B 22 Base, colour temp 6500K complete all as specified and directed by Engr-in-Charge.
24S&F in replacement of ceiling rose, 3 terminal, PVC isolated body complete all as specified and directed by Engr-in-Charge.
25S&F in replacement of switch piano type 5 Amp, 230 Volt, flush type single pole one way complete all as specified and directed by Engr-in-Charge.
26S&F in replacement of socket outlet multipin 5 Amp 230 Volt flush type complete all as specified and directed by Engr-in-Charge.
27S&F in replacement of switch piano type 15 Amp, 230 Volt, flush type single pole one way complete all as specified and directed by Engr-in-Charge.
28S&F in replacement of fan regulator 230 Volt stepped type complete all as specified and directed by Engr-in-Charge.
29S&F in replacement of socket outlet multi pin 15 Amp 230 Volt flush type complete all as specified and directed by Engr-in-Charge.
30S&F in replacement of sheet metal enclosure double door distribution board single pole and neutral, 12 way 240 volt with 100 amps rated bus bar complete with bus and neutral link complete all as specified and directed by Engr-in-Charge.
31S&F in replacement of sheet metal enclosure double door distribution board single pole and neutral, 8 way 240 volt with 100 amps rated bus bar complete with bus and neutral link complete all as specified and directed by Engr-in-Charge.
32S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs complete all as specified and directed by Engr-in-Charge. NOTE :-(a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.[Make- L&T/ Legrand / Indoasian /Havells
33S&F in replacement of MCCB 100 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified and directed by Engr-in-Charge.
34S&F in replacement of Building LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
35S&F in replacement of GI pipe (light grade) bracket of 40mm dia size of 1.2 mtr long bent to shape for fixing of LED street light fittings and fixing to pole, walls etc including fixing of clamp, nut, bolt etc complete all as specified and directed by Engr-in-Charge.
36Supply laying & jointing in replacement aluminium service cable 10 sqmm 2 core fixing on wall/ducts etc including necessary fixing arrangement such as cable lugs glands etc complete after removing/taking out extg unsv cable complete all as specified and directed by Engr-in-Charge.
37S&F in replacement Switch-socket combined 15 amp with Box complete all as specified and directed by Engr-in-Charge.
38S&F in replacement Switch-socket combined 5 amp with Box complete all as specified and directed by Engr-in-Charge.
39S&F in repalacement of LED bulk Head fittings 10 watt warm/white,230 Volts,diffused optics complete with accessories connecting up with twin core twisted flexible copper cable complete all as specified and directed by Engr-in-Charge.
40Taking down ceiling/exhaust fan, BLDC ceiling fan ,ceiling cable complete for reparing & refixing the same complete all as specified and directed by Engr-in-Charge.
41M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) in the workshop wire with appropriate gauge suiatble for existing make including necessary lathingmon shaft, capacitor,Bearing, both sides of rewinding covered with high quality varnish, replacement of ball bearing of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including taking out old burnt wind of copper/aluminium complete all as specified and directed by Engr-in-Charge.
42M&L for rewinding exhaust fan of 300 mm sweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement of ball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified and directed by Engr-in-Charge.
43M&L for opening of BLDC ceiling fan 1200 mm sweep including replacement of PCB card and repair the BLDC ceiling fan and deposit to the MES yard with complete running position complete all as specified and directed by Engr-in-Charge.
44Checking and attending complaints by experience tradesman means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures in office complex ,W/S Installations & E/S Installations maintained by MES daily except national holidays complete all as specified and directed by Engr-in-Charge. Note: 1. Complaints noted'' NO Light,Short circuit,Sparking,Burning etc issues in electric circuits shall be attended imediately up to 2200 hrs on same day without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 2. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape,screws,nut & bolts,washers,fan holding bushes, etc shall deemed to be included in the quoted rate of this item. 3.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding.4. Contracror shall arrange suitable T&P such as Drill machine/cutter machine incl necessary for work and scaffolding and safety measures to make it functional complete all as specified and directed.5. Contractor or his rep will send daily one electrician and one helper at Main Office for collection of complaints from the concerned JE in charge . 6 . Complaint Register including stationary items as per sample shall be provided by the contractor free of cost. 7.All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,fan regulators,MCBs,MCB DB's,MCCB's,security lights,etc shall be paid under respective items of Sch 'A' BOQ8.Item required to replace in repairs based on Day to Day complaints by the users as when as required as site.9.Old unserviceable material obtained from site against issued by the department to be deposited to MES store Yard. 10. The number of workers are required to be increased based upon number of complaints and quantum of work involved and during emergencies irrespective of working hours as decided by AGE/Engr-in-Charge. 11. The work inclludes attending complaints related to repair/replacement of parts and fixing of supply only items as enlisted in Sch'A' BOQ including replacement of switches,sockets,ceiling roses,fan regulator,MCBS,LED fittings,elctic bell,holder,fan bearing,geyser element,CP connection,NEV of geysers,capacitors etc and all other electric works required to keep them fully functional to the entire satisfaction complete all as specified and directed by Engr-in-Charge. 12. A complaint register should be maintain in accordance with supply only items by the contractor & it will have to be produced at the time of payment of the RAR/final bill duly sign by concerned JE & Eng-In-Charge and no payment of supply only items will be allowed without purchase vouchers and complaint register.
45Supply only of copper winding motor of exhaust fan for sweep 300mm as per site requirement complete all as specified and directed by Engr-in-Charge.
46Supply only of outer metallic body including frame & louvre of exhaust fan for sweep 300mm as per site requirement complete all as specified and directed by Engr-in-Charge.
47Supply only of copper winding motor of Fresh air fan for sweep 250mm/300mm as per site requirement complete all as specified and directed by Engr-in-Charge.
48Supply only of PVC body including louvre of fresh air fan for sweep 250 mm/300mm as per site requirement complete all as specified and directed by Engr-in-Charge.
49Supply only of ceiling fan capacitor 2.5 mfd complete all as specified and directed by Engr-in-Charge.
50Supply only LED light fitting 20W, 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
51Supplu only of LED light fitting 10W, 220 volt AC, having colour temperature daylight , Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
52Supply only of MCB 6 to 32 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
53Supply only of MCB SPN 32 amp rating 240V, 10KA 'C' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
54Supply only 2 way PVC box 15 amp complete as per site requirement complete all as specified and directed by Engr-in-Charge.
55Supply only LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light/ warm white light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
56Supply only of MS down rod 300/450 mm for fixing of ceiling fan complete all as specified and directed by Engr-in-Charge.
57Supply only canopy of 1200 mm sweep ceiling fan complete all as specified and directed by Engr-in-Charge.
58Supply only modular cover plate with frame 3 module, complete all as specified per site requirement and directed by Engr-in-Charge.
59Supply only modular cover plate with frame 6 module, complete all as specified per site requirement and directed by Engr-in-Charge.
60Supply only 3 way modular PVC box complete all as specified per site requirement and directed by Engr-in-Charge.
61Supply only 6 way modular PVC box complete all as specified per site requirement and directed by Engr-in-Charge.
62Supply only 3 mm thick hylum sheet 9x11 including cutting of suitable for switch/socket/regulator complete all as specified and directed by Engr-in-Charge.
63Supply only 3 mm thick hylum sheet 8x5 including cutting of suitable for switch/socket complete all as specified and directed by Engr-in-Charge.
64Supply only 3 mm thick hylum sheet 5x5 complete including cutting of suitable for switch/socket all complete all as specified and directed by Engr-in-Charge.
65Supply only metal thick sunken box 4x4 including brass scews and cup complete all as specified and directed by Engr-in-Charge.
66Supply only metal thick sunken box 8x10 including brass scews and cup complete all as specified and directed by Engr-in-Charge.
67Supply only metal thick sunken box 7x4 including brass scews and cup complete all as specified and directed by Engr-in-Charge.
68Supply only building LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
69S&F in replacement of single core copper conductor 2.5 sqmm size including 20 mm pvc conduit pipe with all fixing accessories complete all as specified and directed by Engr-in-Charge.
70S&F in replacement of single core copper conductor 1.5 sqmm size 20 mm pvc conduit pipe with all fixing accessories complete all as specified and directed by Engr-in-Charge.
71S&F in replacement of single core copper conductor 4.0 sqmm size 20 mm pvc conduit pipe with all fixing accessories complete all as specified and directed by Engr-in-Charge.
72S&F in replacement of single core copper conductor 6.0 sqmm size 20 mm pvc conduit pipe with all fixing accessories complete all as specified and directed by Engr-in-Charge.
73S&F in replacement with Solar LED post top lantern 20 watt light in aluminium die cast with modern artistic design and white of suitable size complete including all items such as GI pipe of suitable size, PCC work etc complete all as specified and directed by Engr-in-Charge.
74S&F in replacement of LED bollard light fittings 8/10 watt new generation, energy saving,environmental friendly long life aesthetically designed aluminium landscope IP65 luninaire for diffused lighting with high power led as light source including 3 core PVC copper wire of suitable size PCC work for fixing of bollard light in ground etc complete all as specified and directed by Engr-in-Charge.
75Supplying, laying, & jointing in replacement with suitable size of thimble, connecting and testing in replacement XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables 6.00 Sqmm 2 core (heavy duty) 1100V grade with stranded aluminium conductor laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by Engr-in-Charge . Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
76All as per item No. 74 above but of size 10 Sqmm 2 core complete all as specified and directed by Engr-in-Charge.
77Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etc complete all as specified and directed by Engr-in-Charge.
78M&L for tubes, 'light grade' 40mm dia, galvanised, with all fitting and fixed complete to walls and ceilings or laid in trenches complete all as specified and directed by Engr-in-Charge.
79Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed by Engr-in-Charge.
80Removing excavated surplus material to a distance n.exc 50 m and depositing where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge.
81S&F in replacement of 60 watt Led Post top light for 3600 indirect light with IP 65 protection resistance to impact and corrosion, glare free and better uniformity, complete all as specified and directed by Engr-in-Charge.
82S&F in replacement surface suspended LED luminaire, 36 W, 230 volt, suitable for suspended mounting with extruded aluminium in powder coated housing panel for surface mounting which produces continuous lines of light distribution complete with driver and all accessories internally pre wired and including suspension kit and surface mounting kit and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
83S&F in replacement of 4 side 12 watt led solar wall light waterproof, auto on/off complete all as specified and directed by Engr-in-Charge.
84S&F in replacement of classic outdoor gate light rust & waterproof aluminium die cast exterior Piller lamp base mount for garden, boundary wall of product dimension 15 cm long & 20 cm high including all fixing items such as fasterner nut & bolt etc complete all as specified and directed by Engr-in-Charge.
85S&F in replacement of 20 watt led Gx53 tube light ultra slim 2 ft alumium batten soft cool white complete all as specified and directed by Engr-in-Charge.
86Supply and fixing in replacement LED Flood light 100 Watt 230 V AC with high pressure die cast aluminum hosing and heat resistant complete with driver, corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed.
87S&F in replacement LED flood light 70 Watt 230 V AC with high pressure die cast aluminum hosing and heat resistant complete with driver, corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
88S&F in replacement of corded electric remote controlled led light box type ceiling mounting fan of size 600mm x 600 mm size 95 watt indoor type noise level 45 db 220 volt complete all as specified and directed by Engr-in-Charge. Note:- Old u/s fan will deposited to MES yard by Contractor.
89S&F in replacement of copper winded metallic body 600 mm sweep exhaust fan 4 blade single phase 220 Volt 9400 CMM air delivery 900 rpm heavy duty exhaust fan including cutting of holes and make good surface finish complete all as specified and directed by Engr-in-Charge. Note:- Old u/s fan will deposited to MES yard by Contractor.
90S&F in replacement of copper winded metallic body 450 mm sweep exhaust fan single phase 220 Volt 4 blade 1400 rpm heavy duty exhaust fan including cutting of holes and make good surface finish complete all as specified and directed by Engr-in-Charge. Note:- Old u/s fan will deposited to MES yard by Contractor.
91S&F in replacement of 300mm wall fan 220Volt Ac copper winded 1300 rpm min. 75 CMM air delivery complete all as specified and directed by Engr-in-Charge. Note:- Old u/s fan will deposited to MES yard by Contractor.
92M&L for repair of box type 600mm x 600mm ceiling fan with replacement of led light strip & copper winded motor , capacitor etc complete all as specified and directed by Engr-in-Charge.
93S&F in replacement of solar street light fitting 25 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc including fixing on existing pole complete all as specified and directed by Engr-in-Charge. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58370991
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 50 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint And Day To Day Complaint Of Internal Wiring/Fixture, Exhaust Fan/Ceiling Fan, Post Top Lantern, Bollard Light, Buildings Security Light, Flood Light And Misc E/M Items In Office Complex, W/S Installation & E/S Building Sub Stn Under Age(I) (U) B/R Delhi Cantt-10
Basic Detail
Tender No AGE(I)(U)B/R-TOKEN-45/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 04 Nov 2026
Submission Date 24 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Available
Document List
a3e2beaf-f788-4ab3-b353-65dfeadd0388.html
BOQ_894306.xls
TENDER45.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

a3e2beaf-f788-4ab3-b353-65dfeadd0388.html

xls

BOQ_894306.xls

pdf

TENDER45.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender