Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #58369600

Tender For Provn Of Certain Lbw, Minor Works Under Age B/R-Ii And Provn Of Booster Pump At Af Stn Thanjavur.

Issued by Statutory Bodies & Commissions/Committees · Thanjavur, Tamil Nadu
Tender Value
42.14 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
8 days left
EMD
84500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thanjavur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Provn Of Certain Lbw, Minor Works Under Age B/R-Ii And Provn Of Booster Pump At Af Stn Thanjavur.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Nov-2026 Corrigendum No 01 Other 25-Nov-2026

BOQ

Name of Work:- PROVN OF CERTAIN LBW, MINOR WORKS UNDER AGE B/R-II AND PROVN OF BOOSTER PUMP AT AF STN THANJAVUR.
Sl. No. Item Description
1Please Enable Macros to View BoQ information
2M&L for two coats of Zinc rich epoxy paint over a coat of Modified Alkyd Micaceous iron oxide primer to protect the structures from corrosion of High mast antenna having height not exceeding 26 Mtr from ground of Structural steel surfaces on any description including removing old rusted paint surfaces of any description complete all as specified and as directed.
3M&L for two coats of Zinc rich epoxy paint over a coat of Modified Alkyd Micaceous iron oxide primer to protect the structures from corrosion of High mast antenna having height nit exceeding 26 Mtr from ground of Reinforcement steel surfaces on any description including removing old rusted paint surfaces of any description complete all as specified and as directed.
4Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc 1.5 and n exc 4 sqm complete all as specified and as directed.
5S & F Mild Steel Butt hinges 100mm long cold rolled medium weight complete all as specified and as directed.
6S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming iron or mild stee work of any description not therwise provided for Fe.290.Gde-E-165 complete all as specified and as directed.
7S & F for Mild steel, plain, black sheet Thickness of sheet in 1.25mm covering to door shut ters, covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts, urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded / riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and as directed.
8M & L rendering 15 mm thick on brick wall / cement block wall or concrete surfaces in cement mortar 1:6, surfaces finished even and smooth without using extra cement, on other than fair face surfaces complete all as specified and as directed.
9M&L preparation of new plastered / concrete surface of walls, providing 3mm thick wall care putty to achieve smooth surface and applying two coats of distemper oil emulsion of approved shade / tint over a coat of compatible priming paint complete all as specified and as directed.
10M&L for PCC(1:3:6) type C1 (using 20mm graded stone aggregate) for fixing hold fast/in MS chowkhat complete all as specified and as directed.
11S&F mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece nserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
12Excavation in post holes (or Similar holes) each not exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering and removing surplus soil to a distance not exc 50m and making good surface in soft/loose soil complete all as specified and as directed.
13M&L for providing cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concreting complete all as specified and as directed.
14Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in Soft / loose soil complete all as specified and as directed.
15Removing excavated material (soil) not exc 50 m and depositing where directed at the level not exc 1.5 m above the starting point complete all as specified and as directed.
16Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
17M&L for hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface complete all as specified and as directed.
18M&L PCC 1:4:8 type D-2 100 mm thick as in sub base of floor complete all as specified and as directed.
19M&L precast Cement concrete machine pressed coloured interlocking block 60mm thick M-35 (as per sample approved), Joint and pointed in neat cement slurry as in floors complete all as specified and as directed.
20M&L for 30 mm thick sand filling in bedding layer for laying floor finishes complete all as specified and as directed.
21S&F steel work in tabular truss including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 of grade St-240 complete all as specified and as directed.
22S&F plates (plain or chequered) Channels, square, cut or notched (ordinary and counter sunk) forming holes without any attachment of Fe-410-W (Grade E-250) quality B complete all as specified and as directed.
23S&F mild steel works such as wind ties for roof including securing with bolts etc and similar work using rolled section confirming to Fe-290 Gde E-165 complete all as specified and as directed.
24S&F pre-colour coated high tensile strength galvalume sheet roofing with yield strength (550 MPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through specialist agency and as per profile complete all as specified and as directed.
25S&F Pre-painted galvalume aluminum zinc coating GI based Plain sheet roofing with yield strength (550 MPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions complete all as specified and as directed.
26M&L for applying two coats of synthetic enamel paint over Zinc chromite primer including preparation of steel surfaces complete all as specified and as directed.
27M&L Preperation of new steel surfaces of any description over 10 cm in width or girth and apply two coats of synthetic enamel paint over one coat of redoxide primer complete all as specified and as directed.
28M&L Cutting holes in brick walls inbuilt in cement mortar or cement lime mortar andstone walls for inserting holdfasts and making good dismantled portion in cement mortar 1:3 and applying two coats of exterior emulsion paint exc. half brick but not exc one brick complete all as specified and as directed.
29M&L for RCC(20mm graded stone aggregates) type B1 1:2:4 in Columns, pillars, piers, posts and struts complete all as specified and as directed.
30Use and waste of formwok for fair finished of sides of pillars, posts, struts, piers, columns and stanchions on flat surface complete all as specified and directed.
31M&L Reinforcement 10 mm bar and aboveTMT bars, cut to length and bent to shape required, including cranking and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
32Providing and fixing (upto 20mm dia) approved heavy-duty chemical anchor/ fasteners for securing the RCC pedestal to the existing RCC roof structure, including drilling of holes, cleaning of drilled holes, supply and injection of approved chemical anchoring adhesive (epoxy/vinylester type), and installation of suitable threaded anchor rods with nuts and washers, complete in all respects.The anchor/ fasteners shall be of suitable size, grade, embedment depth and spacing as per approved design, considering the wind load and overturning moment of the flag mast. The work shall include all necessary tools, drilling, chemical adhesive, anchor rods, nuts, washers and labour. Existing reinforcement and waterproofing shall not be damaged during execution. The complete work shall be carried out complete all as specified and as directed.
33Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
34M&L for light shade vitrified ceramic tiles 8-10 mm thick polished area of each tiles not exc 0.36 sqm but n. exc 0.42 Sqm, of any shade and any pattern (Pattern consists combination of two or more tiles ) as in floor etc jointed in neat cement slurry and pointed in colored cement to match colour tiles over and including 15mm thick screed bed in CM 1:6 and pointed in colored cement to match coloured tiles complete all as specified and as directed.Note : The Colour,shade and pattern shall be approved by the GE during execution work. No extra cost sahll be allowed for Removing and re-fixing and necessary cutting of door etc if any required during execution of work
35S&F anodised aluminium powder coated frame for doors, windows, with one or more rebates including joints cleat for fixing etc complete all as specified and as directed.
36S&F 5.50 mm thick sheet tinted glass ordinary quality and glazing with aluminium clip square exc 0.5 sqm in each pane complete all as specified and as directed.
37S&F 5 mm thick Figared glass pin head type gloging with oil putty in squared exc 0.5 sqm in each pane complete all as specified and as directed.
38S/F 12 mm thick prelaminated particle board exterior grade both sides with decorative choice lamination fixed with frame work complete all as specified and as directed.
39S&F Aluminium extruded section body door closer hydraulically regulated designation No 2 universal type suitable for door shutter of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and as directed.
40S&F floor door stopper of alumunium alloy body and 150 mm over all length of cover plate, tongue, anodised with hard drawn steel spring fixed in floor complete all as specified and as directed.
41S&F mortice lock brass 4 levers vertical type size 100 mm complete all as specified and as directed.
42S&F GI grid frame work for false ceiling with 605 x 605 mm sixze, consisting of main Tee of size 23.50 x 36.50 x 1.50mm, cross Tee of size 23.50 x 36.50 x 1.50mm and wall angle of size 36 x 25 x 1.50mm of approved make including all necessary cutting, fixing of aluminium section firmly in position with and including fixing with suitable fastener and including provision of 18 to 19mm thick perforated calcium silicate board as in wall cladding complete all as specified and as directed..Note : Rate quoted above shall be deemed to include for makng holes cutting chasis if any required and making good to existing walls in cement mortar 1:3 to match with existing surface finish as directed at site.
43M&L for Glazed ceramic tiles White (300x450mm) x 7mm thick, in wall/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick backing coat of tiles in CM (1:3) complete all as specified and as directed.
44Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, complete all as specified and as directed.
45M & L for Non Skid coloured ceramic tiles 7 to 8mm mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white cement with pigment to match the tile colour over 15mm thick screed bed in cement mortar (1:4) of floor tiles including cement mortar bedding of any thickness rubbish off the premises complete all as specified and as directed.
46M & L for prepration of new plastered or unplastered surfaces of and applying two coat of white wash on ceiling complete all as specified and as directed.
47Surface excavation not exc 30cm deep & averaging 15cm deep and getting out hard / dense soil complete all as specified and as directed.
48Excavation in trenches not exc 1.50 mtr wide and not exc 1.50 mtr deep and getting out in hard dense soil for foundation etc complete all as specified and as directed.
49M&L for PCC 1:4:8 type D2 (40 mm graded stone aggregate) in foundation and mass concrete complete all as specified and as directed.
50M & L Formwork to sides of concrete foundations, footings,bases of columns sides and soffits (if any) of foundation and plinth beams; and similar work;vertical or to batter for fair finished surfaces complete all as specified and as directed.
51M&L TMT bars 6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
52M&L for reinforced cement concrete 1:1.5:3 type A-1 (nominal mix) (using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc complete all as specified and as directed.
53M&L for reinforced cement concrete 1:1.5:3 type A-1 (nominal mix) (using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and as directed
54M & L for 50 mm thick PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in floors finishing surface even and smooth using extra cement complete all as specified and as directed.
55M&L for Pre- cast cement concrete type C1 1:3:6 (20 mm graded stone aggregate) block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
56M&L for Rendering in CM1:4, 15 mm thick on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
57M&L for Rendering in CM1:6, 10 mm thick other than fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
58Material and labour for preparation of newly plastered wall surfaces and applying three coats of white wash complete all as specified and as directed.
59M&L for Preparation of new surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
60S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc to FE 410-W (Gde-E-250) quality -A complete all as specified and as directed.
61S & F for plain, black, 1mm mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and as directed.
62S & F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed.
63S & F MS hold fast for doors and windows etc complete all as specified and directed.
64S & F Glass dividing 28mm thick strips, 3 mm thick inserted in position, conform to design complete all as specified and as directed.
65M & L for Cement concrete type C1, 1:3:6 (20mm graded stone aggregate) 75 mm thick as in Plinth protection including necessary form work as required complete all as specified and as directed.
66Returning filling in including spreading, levelling watering and well ramming in layers n exc 25 cm thick in hard/dense soils complete all as specified and as directed.
67Removal of excavated soil to a distance exc 1.50km and depositing where directed at a level not exceeding 5km above the starting point including loading, unloading complete all as specified and as directed complete all as specified and as directed.
68Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and as directed.
69Non skid coloured ceramic tiles of any shade and any pattern of sixe (Pattern consists combination of two or more tiles ) exceeding 0.06 sqm but not exceeding 0.11 sqm 7 to 8-10mm thick, over and including 15mm thick screed bed in CM 1:6 as in floors etc. jointed in neat cement slurry and pointed in colored cement to match coloured tiles complete all as specified and as directed. Note: The Colour,shade and pattern shall be approved by the GE during execution work.
70M&L for glazed ceramic Coloured tiles of any shade and any pattern of sixe (Pattern consists combination of two or more tiles ) in vertical surface 450x350x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles over and including 10mm thick backing coat in CM 1:4 complete all as specified and as directed.
71S&F PVC (SWR) pipes 75mm dia, single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
72S&F PVC (SWR) bend 75mm dia without access door complete all as specified and as directed
73S&F PVC (SWR) 75mm bore vent cowl complete all as specified and as directed.
74S&F 1000 ltr capacity roattional moulded polyethylene water storage tanks (cylindrical vertical with closed top) twisted and fixed in position complete all as specified and as directed.
75S&F half / quarter turn 15mm bore bib tap, cast brass chromium plated type with crutch or butterfly handle, screwed for iron pipe long body complete all as specified and as directed.
76S&F half / quarter turn 15mm stop valves, cast brass chromium plated with crutch or butterfly handle complete all as specified and as directed.
77Supply and fix half/quarter turn 15 mm dia Angle cock, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down high pressure with crutch or butterfly handle, screwed both ends iron pipe including taking down old cock, complete all as specified and as directed.
78Supply and fix 15 mm unplasticised PVC pipes of pressure rating 10kg\cm2 fixed to walls or laid in floors, complete all as specified and as directed.
79Supply and fix 20 mm unplasticised PVC pipes of pressure rating 10kg\cm2 fixed to walls or laid in floors, complete all as specified and as directed.
80Supply and fix 25 mm unplasticised PVC pipes of pressure rating 10kg\cm2 fixed to walls or laid in floors, complete all as specified and as directed.
81Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 25 sqmm 4 core with all fixing & connecting accessories like alluminium lugs cable glands etc. complete all as specified and as directed.
82Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.Note :- Mechanical excavation is not allowed in this Stn only manual excavation allowed.
83Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and as directed. Note:- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning.
84M&L for laying in trenches burnt brick sub class 'B' for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified and as directed.
85S&F laying 50 mm bore, steel tubing's galvanized, light grade with all fittings fixing along the electric cable laying in trench or pole / wall for protection of cable complete all as specified and as directed.
86S&F SPN enclosure socket (modular type) complete with one single pole mini protection MCB 20 Amp rating complete all as specified and as directed.
87M&L Submain wiring with 2 run of 4sqmm (nominal cross sectional area) PVC insulated unsheathed single core flam retardant cable (FR) of working voltage 1100V grade with stranded copper conductor incl 01 run of 4dqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant with cable with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and incl 20mm dia PVC rigid non-metallic conduit complete all as specified and as directed.
88S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type ^ designated for input variation between 170 to 250 V with oiutput voltage stabilizer at 230V with accuracy of +/- 2.5% and of capacity 4KVA complete all as specified and as directed.
89Supply, installation, commissioning of water cooler with RO fully SS electric driven single phase having approx 120/60 in ltrs storage and nominal cooling capacity complete all as specified and as directed.
90Cutting existing steel tubing of size 25/32mm bore for alterations or additions (each cut measured) done in position without taking down complete all as specified and as directed.
91Screwing existing steel tubing for alterations or additions (or lenghtening screw on pipe to form connector) done in position without taking down complete all as specified and as directed.
92M&L GI steel tubing medium grade including all fittings such as Tees, elbow, bends etc for 15mm bore of pipe including connecting with existing pipe with suitable tee etc complete all as specified and as directed.
93S & F Gun metal gate valve iron wheel head screwed both ends for GI steel tubing suitable for 15mm bore of pipe complete all as specified and as directed.
94S & F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
95Rotational moulded polye-thylene water storage tanks of capacity 1000 Ltr 5 layerd (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
96M&L GI steel tubing medium grade including all fittings such as Tees, elbow, bends etc for 25 mm bore of pipe including connecting with existing pipe with suitable tee etc complete all as specified and as directed.
97S & F Gun metal gate valve iron wheel head screwed both ends for GI steel tubing suitable for 15mm bore of pipe complete all as specified and as directed.
98S & F Ball polythene float valve and flynut complete,screwed for GI pipe or brass ferrule suitable for 25 mm complete all as specified and as directed.
99S&F monoblock booster pump self priming set of capacity 2.0 HP with starter panel and connected necessary electric and water connection and foundation work complete all as specified and as directed.

AI Tender Summary

OUR REF NO 58369600
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.14 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Provn Of Certain Lbw, Minor Works Under Age B/R-Ii And Provn Of Booster Pump At Af Stn Thanjavur.
Basic Detail
Tender No 8323/E8
Bidding Type Tender
Location
City Thanjavur
State Tamil Nadu
Key Dates
Publish Date 12 Nov 2026
Submission Date 25 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 42.14 Lakhs
Tender Fee 500
EMD 84500
Exemption Available
Document List
18326304-e83b-417d-a4bb-2b113afcb6d6.html
BOQ_894208.xls
TenderDocuments8323.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

18326304-e83b-417d-a4bb-2b113afcb6d6.html

xls

BOQ_894208.xls

pdf

TenderDocuments8323.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender