Tender For Provn Of Transformer With Associated Infra At Living Out Area At Af Stn Mohanbari
Tender Overview
Project Description
Tender for Provn Of Transformer With Associated Infra At Living Out Area At Af Stn Mohanbari
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Nov-2026 | Amendment | Other | 27-Nov-2026 |
| 2 | 19-Nov-2026 | Amendment to critical dates | Date | 27-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, install, testing & commissioning, of Transformer, Outdoor type,Copper wound,ONAN cooled transformer of capacity 400 KVA complete with standard fitting HT 11 KV,3 Phase ,LT 433 Volts, phase 4 wire (Dyn11) with off load tap changer with range -10% to +5% in steps of 2.5% on HT side to vary secondary voltage all as per IS 1180 Level-II complete all as specified and directed.(a) Technical details:-(i) No load voltage ratio(Normal Tap)-11000/433V(ii) No. of Phases-03.(iii) Frequency-50 Hz(iv) Type of cooling- ONAN(v) Winding connection- The primary winding(HV) shall be connected in Delta and secondary winding(LV) shall be connected in star.(vi) Vector group- Windings shall be connected as per vector symbol:Dyn11(vii) Neutral Earthing- The neutral point of secondary(LV) winding shall be brought out to a seperate insulated terminal and shall be solidly earthed.(viii) off load Tap changer of the Transformer - Voltage tapping range on HV side will be (-10%) to(+5%) in steps of 2.5%. The tap changing switch shall be located in a convenient positions so that it can be operated from ground level.The switch handle shall be provided with a locking arrangement along with tap position.(ix) The percentage impedance at 75 deg C & 50 Hz refer to the (normal) Pricipal Tapping shall be as per BIS BEE rating.(x) Losses- Minimum losses as per BIS BEE rating. Please Enable Macros to View BoQ information |
| 2 | Supply, install, testing & commissioning, of Transformer, Outdoor type,Copper wound,ONAN cooled transformer of capacity 400 KVA complete with standard fitting HT 11 KV,3 Phase ,LT 433 Volts, phase 4 wire (Dyn11) with off load tap changer with range -10% to +5% in steps of 2.5% on HT side to vary secondary voltage all as per IS 1180 Level-II complete all as specified and directed.(a) Technical details:-(i) No load voltage ratio(Normal Tap)-11000/433V(ii) No. of Phases-03.(iii) Frequency-50 Hz(iv) Type of cooling- ONAN(v) Winding connection- The primary winding(HV) shall be connected in Delta and secondary winding(LV) shall be connected in star.(vi) Vector group- Windings shall be connected as per vector symbol:Dyn11(vii) Neutral Earthing- The neutral point of secondary(LV) winding shall be brought out to a seperate insulated terminal and shall be solidly earthed.(viii) off load Tap changer of the Transformer - Voltage tapping range on HV side will be (-10%) to(+5%) in steps of 2.5%. The tap changing switch shall be located in a convenient positions so that it can be operated from ground level.The switch handle shall be provided with a locking arrangement along with tap position.(ix) The percentage impedance at 75 deg C & 50 Hz refer to the (normal) Pricipal Tapping shall be as per BIS BEE rating.(x) Losses- Minimum losses as per BIS BEE rating. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender