Tender For Restoration Of Pumping Service Of 200Kw 11Kv Ht Motor No. 1 By Supply Fitting And Fixing Of Necessary Spares At Patuli Booster Pumping Station
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Nov 2026
14 days left
EMD
6000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Restoration Of Pumping Service Of 200Kw 11Kv Ht Motor No. 1 By Supply Fitting And Fixing Of Necessary Spares At Patuli Booster Pumping Station
BOQ
| Sl. No. | Item Description |
| 1 | 5.3 J.3 DISASSEMBLING THE MOTOR END AND OPENING OF END SHIELD COVERS, STATOR COIL GUARD, TAKING OUT THE ROTOR FROM THE STATOR AND PLACING IT ON THE PROPER ARRANGEMENT BY HOISTING MECHANISM. THOROUGHLY CLEANING OF THE STATOR COIL INSULATIONS, MOTOR BEARINGS, ROTOR CORE SURFACE AND END RING JOINTS TO DEMOISTURISHING OF THE DEPOSITED CARBON WITH CARBON TETRACHLORIDE AND HEATING THE STATOR BY SILICON HEATING ELEMENYS PERIODICALY AT A REQUIRED TEMPERATURE AND COVERED WITH TERPULIN FOR HEAT PROTECTION ALONG WITH THE ARRANGEMENT OF COMPRESSEDF AIR TO BLOW THE VAPOUR MOISTURE AND TO DEVELOP ITS IR VALUE AND VARNISHING WITH DR. BECK?S GRADED CLASS-H VARNISH INCLUDING JEL EPOXY COATYING TYO PREVENT FROM THE MOISTURE. 5.3 J.3.2 UPTO 475KW SQUIRRELCAGE INDUCTION MOTOR OF VOLTAGE RATING 6.6KV (USOR M&E IRRIGATION AND WATERWAYS GOVT. OF WB, W.E.F. 10TH MAY,2022) |
| 2 | MANUFACTURING, FABRICATION, SUPPLY, FITTING & FIXING OF THE MS CABLE TERMINAL BOX BY PROVIDING ALL STIFMESS, GASKETS, PHASE ISOLATION COMPONENT, STUDS ETC. AS PER THE REQUIRED SIZE AND SHAPE OF THE EXISTING HT MOTOR AFTER REPLACING THE DAMAGED TERMINAL BOX AND COMPLETE IN ALL RESPECT AS PER DIRECTION OF EIC (WATT*NO. OF POLES/RPM) APPROVED RATE BY DG WS DTD. 26.02.2019 |
| 3 | Making Indoor type End termination Joint by providing all required terminal joints accessories {viz Heat Shrink Type End Termination Jointing Kits complete with all accessories for 3 core 6.6KV(UE)-11KV (E) XLPE Screened Cable, Aluminium Conductor}& man/equipments tools & tackles etc with the relevant Switch Gear inside the Pumping Station or Switch Room with care & caution including compliance of relevant safety norms & conforms to the relevant IS and complete in all respect as per direction of EIC. 3 core 6.6KV (UE)-11KV (E) XLPE Screened Cable, Aluminium Conductor of following Sizes 240- 300 Sq mm Indoor type Heat Shrinkable Joint (Rechem KIT No- EPKT 3121) |
| 4 | MAKING HT CONNECTOR OF MOTOR TERMINALS WITH ALL EXISTING CABLES CONNECTED WITH THE FEEDER BREAKER/CAPACITOR/SOFT STARTER & LT CONNECTION AS EXISTS OF THE MOTOR SPACE HEATER/MOTOR TEMPERATURE SCANNER & EARTHING TERMINAL ETC. COMPLETE IN ALL RESPECT AS PER DIRECTION OF EIC. APPROVED RATE BY DG WS DTD. 26.02.2019 |
| 5 | REPLACEMENT OF THE DAMAGED STATION END TERMINAL (COPPER CONDUCTORS) FROM HT RATED STATOR WINDING TO TERMINAL BOARD AND MAKE NECESSARY CONNECTION BY PROVIDING ALL SOCKETS SLEEVES ETC. & COMPLETE IN ALL RESPECT WITH PROPER CARE AND CAUTION AS PER DIRECTION OF EIC. APPROVED RATE BY DG WS DTD. 26.02.2019 |
| 6 | 5.3 J.5 REASSEMBLING THE 3.3 KV /6.6 KV SQ. CAGE INDUCTION MOTOR INCLUDING PLACING THE ROTOR INTO THE STATOR, REFIXING THE COIL GUARD, PREFIXING THE MOTOR COVERS, TERMINAL LEADS, TERMINAL BLOCKS, CABLE ENTRY BOX, TERMINAL BOX AFTETR COMPLETION OF REPAIRING WORKS. 5.3 J.5.2 UPTO 475KW SQUIRRELCAGE INDUCTION MOTOR OF VOLTAGE RATING 6.6KV (USOR M&E IRRIGATION AND WATERWAYS GOVT. OF WB, W.E.F. 10TH MAY,2022) |
| 7 | 5.3 J.6 REFITTING THE PUMP MOTOR (3.3 KV /6.6 KV SQ. CAGE INDUCTION MOTOR) SET WITH ALL ITS NECESSARY COUPLING ACCESSORIES TO ITS ORIGINAL POSITION INCLUDING FITTING FIXING WITH BEARING HOUSING, NON-REVERSIBLE RETCHED UNIT AND PUMP SHAFT WITH PROPER TOLERANCE AND CLEARANCE AND RECONNECTION OF TERMINAL POINTS OF THE COMPLETION OF NECESSARY WORK AND SATISFACTORY 2 HOURS TRIAL RUN OF THE PUMP AS PER DIRECTION OF E.I.C. (USOR M&E IRRIGATION AND WATERWAYS GOVT. OF WB, W.E.F. 10TH MAY,2022) |
| 8 | 5.3 J.7 PROPERLY CHEEKING, TESTING OF DEVELOPED IR VALUE OF THE MOTOR, LEAKAGE FACTOR OF BUSHINGS, TERMINAL SHORTINGS, IR VALUE OF G.F.BLOCKS ETC. AFTER THE NECESSARY REPAIRING WORKS FOR 3.3 KV /6.6 KV SQ. CAGE INDUCTION MOTOR (USOR M&E IRRIGATION AND WATERWAYS GOVT. OF WB, W.E.F. 10TH MAY,2022) |
| 9 | Making Straight through Joint by providing all required jointing accessories {viz-viz Heat Shrink Type End Termination Jointing Kits complete with all accessories for 3 core 6.6KV (UE)-11KV (E) XLPE Screened Cable, Aluminium Conductor} & man/equipments tools & tackles etc with care & caution including compliance of relevant safety norms & conforms to the relevant IS and complete in all respect as per direction of EIC. 3 core 6.6KV (UE)-11KV (E) XLPE Screened Cable, Aluminium Conductor of following Sizes 240- 400 Sq mm Indoor type Heat Shrinkable Joint (Rechem KIT No- EPKJ 3118) |
| 10 | Sub Total |
| 11 | GST 18% |
| 12 | CESS 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender