Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #58365854

Tender For Provn Of 01 High Mast Light, Wiring And Standby Power Supply With Connected Items At Certain Otm Locations And Provn Of Iron Grating On Qty-02 Swts (15K Glns) At 2405 Sqn At Af Stn Chabua Under Ge(Af) Chabua

Issued by Statutory Bodies & Commissions/Committees · Dibrugarh, Assam
Tender Value
46.46 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
5 days left
EMD
93000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dibrugarh → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 01 High Mast Light, Wiring And Standby Power Supply With Connected Items At Certain Otm Locations And Provn Of Iron Grating On Qty-02 Swts (15K Glns) At 2405 Sqn At Af Stn Chabua Under Ge(Af) Chabua

BOQ

Name of Work:- PROVN OF 01 HIGH MAST LIGHT, WIRING AND STANDBY POWER SUPPLY WITH CONNECTED ITEMS AT CERTAIN OTM LOCATIONS AND PROVN OF IRON GRATING ON QTY-02 SWTs (15K GLNS) AT 2405 SQN AT AF STN CHABUA UNDER GE(AF) CHABUA
Sl. No. Item Description
1Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil.
2Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil all as specified and directed
3Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point all as specified and directed
4Supply & lay HDPE pipe 120mm bore for laying of LT cables etc complete with all accessores all as specified and directed
5Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium of following size:-(a) 25 Sqmm 31/2 core
6(b) 95 Sqmm 31/2 core
7(c) 240 Sqmm 31/2 core
8M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
9Supply, installation, testing and commissioning of one 16 m high mast with 08 Nos. 200 W LED floodlights, solar PV power supply and battery backup for two nights.Detailed technical specifications are as under1. High mast: 16 m above ground level, hot-dip galvanized polygonal steel construction, designed for applicable site wind loads in accordance with relevant IS 875 provisions. Include a motorised raising/lowering mechanism, winch, head frame, lantern carriage, locking arrangement and maintenance accessories.2. LED floodlights: 08 Nos. × 200 W, total connected lighting load 1.6 kW. Outdoor floodlights shall have a minimum IP66 enclosure, suitable surge protection, high-efficiency LED modules, corrosion-resistant housing and photometric test documentation.3. Solar PV array: Approximately 5 kWp of PV modules, including mounting structure, DC cabling, connectors, isolators and suitable overcurrent protection.4. Battery bank: Approximately 30 kWh nominal LiFePO₄ battery capacity with battery management system, cell protection and suitable enclosure. Final capacity shall be verified against the approved operating schedule and guaranteed autonomy.5. Charge controller: MPPT-based controller with PV input, battery charging regulation, overload protection, low-voltage protection and monitoring facilities, rated for the selected PV and battery configuration.6. Foundation: RCC foundation designed according to soil bearing capacity, mast manufacturer's foundation drawings, wind loading and anchor-bolt requirements. 7. Earthing and lightning protection: Provide suitable earthing electrodes, protective conductors, bonding, lightning protection and surge protection in accordance with applicable standards and site requirements.8. Testing and commissioning: Include insulation and continuity tests, earthing resistance measurements, PV output verification, battery autonomy tests, lighting operation tests and demonstration of the raising/lowering mechanism.9. Warranty: Specify a minimum five-year warranty for the complete installation, with separate warranty requirements for the battery, PV modules, LED floodlights and mast mechanism as appropriate.10. Battery backup calculationFor preliminary sizing, assume the lights operate for six hours per night at full load.
10S&F in repair for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through & including PVC casing-caping medium grade complete all as specified and as directed.
11All as per ser item No 08 here-in-before but 2x 4 sqmm for Phase and Neutral and 1x 4 sqmm for earth wire
12S&F in repair MCB DB TPN 4 way with metal door suitable for Provision of incomer MCB and outgoing MCB's complete all as specified and as directed.
13S&F in repair MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
14S&F in repair MCB SPN 240 volt 32 Amps 'C' Series 10 KA complete all as specified and directed at site.
15S&F in repair MCB FP 240 volt 63 Amps 'C' Series 10 KA complete all as specified and directed at site.
16S&F in repair MCB SP 240 volt 6 to 32 Amps 'C' Series 10 KA complete all as specified and directed at site.
17M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x 6 mm buried directly in ground verticvally to depth not less than 2.25 mtr below ground level and with top edge of the plate at a depth not less than 1.5 mtr below ground level, size of dipth 0.90 x 0.9 x 2.25 mtr ,earth plate connected to galvanised earth wire of size 4.00 mm dia 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth lead protection pipe light gade GI of size 15 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing lead with Main switch/main control board,filling with charcoal dust 200 Kg, and common salt 100 KG , including necessary excavation and earth work in any type of soil ,perforated watering pipe of 20 mm light grade,funnel with wire mesh,PCC chamber 1:3:6 type C1 of size 400mm x400 mm x400mm(for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC
18Supply and Fixing bus bar enclosure 800 mm x 600 mm x 200 mm made out of 3.00 mm thick CRCA steel sheet duly powder coated with provn of MCCB 200 Amp, 25 kA ,4 pole, thermal magnetic type based fitted in bus bar enclosure by using 200 Amp rated aluminium bus bar and RYB indication lamps duly protected by 2A SP MCB outdoor type by using suitable size of copper wire and bus enclosure shall be welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 ; Complete all as specified and as directed by the Engineer-in-charge.Note - Height of the enclouser from ground level shall not be less than 0.5 meter .
19M&L for providing plain cement conrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in copings, steps, plinth courses, haunching, benching, kneelers, apex stone bed plates and the like including weathering slightly rounded or chamfered angles and throating with and including necessary formwork to achieve even and smooth finish complete all as specified and directed.
20M & L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed
21M &L for applying two coats exterior grade emulsion paint on newly plastered surface of wall over a coat of primer including preparation of surface all as specified and as directed
22S&F framed work such as grills, gratings etc. with ends of bars shouldered and or rebated or forged into spikes, framed guard bars etc confirming to Fe-290-Gde-E-165 complete all as specified and as directed.
23M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58365854
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.46 Lakhs
LAST DATE 27-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 01 High Mast Light, Wiring And Standby Power Supply With Connected Items At Certain Otm Locations And Provn Of Iron Grating On Qty-02 Swts (15K Glns) At 2405 Sqn At Af Stn Chabua Under Ge(Af) Chabua
Basic Detail
Tender No 864
Bidding Type Tender
Location
City Dibrugarh
State Assam
Key Dates
Publish Date 04 Nov 2026
Submission Date 27 Nov 2026
Open Date 04 Dec 2026
Finance
Tender Value 46.46 Lakhs
Tender Fee 500
EMD 93000
Exemption Available
Document List
b8726df1-410c-4dad-8b2f-fe38630bb29e.html
BOQ_894235.xls
generalpage.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

b8726df1-410c-4dad-8b2f-fe38630bb29e.html

xls

BOQ_894235.xls

pdf

generalpage.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender