Tender For Repair / Replacement Of Three Phase Ups System With Allied Works And Maintenance Of Mafi Afls/Czech/Afls At Af Stn Chabua Under Ge (Af) Chabua
Tender Value
45 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
5 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dibrugarh → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Replacement Of Three Phase Ups System With Allied Works And Maintenance Of Mafi Afls/Czech/Afls At Af Stn Chabua Under Ge (Af) Chabua
BOQ
| Sl. No. | Item Description |
| 1 | M&L for comprehensive maintenance and repair including replacement of defective parts/fittings including all electronics and electrical spares required for comprehensive maintenance during the entire contract period through AMC 2 KVA to 30 KVA Online UPS System (details mentioned below in NOTE:-1) installed at various wards/area under base hospital during the period of contract every month. NOTE -11.102 Sqn. -03 No2.FMS .- 02 No.3.Dicom- 01 No.NOTE - 2(i) All work shall be carried out only by authorised Rep of OEM and using all genuine spare parts supplied by OEM only, in this regard an MOU between OEM and the Contractor must be perform, A copy of the same MOU shall be uploaded with the tender document in cover - 1 (Tech Bid).(ii) Contractor should be responsible of proper functioning of all the machine.(iii) Batteries for the UPS if required shall be paid sepretaly in respective schedule.(iv) Contractor through OEM shall be responsible for repair and replacement of all defective parts of the equipment as per OEM recommendation during entire comprehensive maintenance period.(v) Preventive maintenance of all systems on monthly basis and upkeep of log book.(vi) Attending all complaints within 24 working hours intimated by Engr-in-Charge.(vii) Field service report shall be maintained and submitted to the Engr-in-charge after expiry of every month and before submission of RAR .(viii) The rates quoted by the contractor shall deemed to be inclusive of necessary T&P etc.(ix) A damage of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by Engr-in-Charge.(x) Contractor also displays his contact number near UPS System and complaint shall be attended immediately within time frame given in particular specification. (ix)Every month Technician shall check serviceability of UPS and serviceability report of system shall be submitted by the contractor. |
| 2 | Dismanling all connection,Repair, Refixing, configuration, and testing of the internal communication Hot-Swappable Inverter/Rectifier Power Module for 3-Phase True Online Double Conversion UPS System upto 30 KVA Vertiv make UPS , including troubleshooting of communication ports, firmware update, replacement of faulty networking components, and verification of remote monitoring alerts/LIFE Services integration to ensure seamless data transmission to the UPS complete in all aspect all as specified and as directed. |
| 3 | Dismanling all connection,Repair, Refixing, configuration, and testing of the Manual Maintenance Bypass (MMB) Switchgear/Board, designed to provide break-before-make switching for isolating the main UPS unit without interrupting power to the critical load for 3-Phase True Online Double Conversion UPS System upto 30 KVA Vertiv make UPS , including troubleshooting of communication ports, firmware update, replacement of faulty networking components, and verification of remote monitoring alerts/LIFE Services integration to ensure seamless data transmission to the UPS complete in all aspect all as specified and as directed. |
| 4 | Supply & fixing in Replacement Sealed Maintenance Free 12V/65AH Batteries with suitable size terminal link upto 30 KVA UPS. |
| 5 | Supply & fixing in Replacement bussmann series 160 amp BS88-4 HRC fuse suitable for 30 KVA UPS complete in all aspect all as specified and as directed. |
| 6 | Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil. |
| 7 | Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil all as specified and directed |
| 8 | Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point all as specified and directed |
| 9 | Supply & lay HDPE pipe 110 mm bore for laying of LT cables etc complete with all accessores all as specified and directed |
| 10 | Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium of following size:-(a) 10 sqmm 4 core |
| 11 | (b ) 25 Sqmm 4 core |
| 12 | (c) 50 Sqmm 31/2 core |
| 13 | (d) 70 Sqmm 31/2 core |
| 14 | (e) 95 Sqmm 31/2 core |
| 15 | (f)120 Sqmm 31/2 core |
| 16 | M & L for repair to existing damaged surface of road by using necessary stone/PCC etc & tarcoal for making smooth surface of road complete matching with existing all as specified and directed. |
| 17 | Supply and Fixing bus bar enclosure 800 mm x 600 mm x 200 mm made out of 3.00 mm thick CRCA steel sheet duly powder coated with provn of MCCB 200 Amp, 25 kA ,4 pole, thermal magnetic type based fitted in bus bar enclosure by using 200 Amp rated aluminium bus bar and RYB indication lamps duly protected by 2A SP MCB outdoor type by using suitable size of copper wire and bus enclosure shall be welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 ; Complete all as specified and as directed by the Engineer-in-charge.Note - Height of the enclouser from ground level shall not be less than 0.5 meter . |
| 18 | Supply and Fixing bus bar enclosure 800 mm x 600 mm x 200 mm made out of 3.00 mm thick CRCA steel sheet duly powder coated with provn of MCCB 100 Amp, 25 kA ,4 pole, thermal magnetic type based fitted in bus bar enclosure by using 200 Amp rated aluminium bus bar and RYB indication lamps duly protected by 2A SP MCB outdoor type by using suitable size of copper wire & bus bar enclosure shall be welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 ; Complete all as specified and as directed by the Engineer-in-charge.Note - Height of the enclouser from ground level shall not be less than 0.5 meter . |
| 19 | Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed.Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates. |
| 20 | Material and labour for providing skilled electrician for maintenance of MAFI/Airfield Lighting system to Air force CSR section, Chabua Note :- (a) Digging, repairing or replacing the cables supplied by Air Force Chabua, relaying and closing of the trenches for the Air Field Lighting System.(b) Epoxy/heat sink jointing of underground cables.(c) Earth work, masonry and concrete works required for repair of light points.(d) Supporting minor repairs of 11 KV/400 Volt Transformer and HT switch gear.(e) Support in repair and maintenance of earthing system.(f) Cleaning of dust from AFLS and water accumulation from inset lights and CI box trenches Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender