Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #58365853

Tender For Repair / Replacement Of Three Phase Ups System With Allied Works And Maintenance Of Mafi Afls/Czech/Afls At Af Stn Chabua Under Ge (Af) Chabua

Issued by Statutory Bodies & Commissions/Committees · Dibrugarh, Assam
Tender Value
45 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
5 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dibrugarh → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Replacement Of Three Phase Ups System With Allied Works And Maintenance Of Mafi Afls/Czech/Afls At Af Stn Chabua Under Ge (Af) Chabua

BOQ

Name of Work:- REPAIR / REPLACEMENT OF THREE PHASE UPS SYSTEM WITH ALLIED WORKS AND MAINTENANCE OF MAFI AFLS/CZECH/AFLS AT AF STN CHABUA UNDER GE (AF) CHABUA
Sl. No. Item Description
1M&L for comprehensive maintenance and repair including replacement of defective parts/fittings including all electronics and electrical spares required for comprehensive maintenance during the entire contract period through AMC 2 KVA to 30 KVA Online UPS System (details mentioned below in NOTE:-1) installed at various wards/area under base hospital during the period of contract every month. NOTE -11.102 Sqn. -03 No2.FMS .- 02 No.3.Dicom- 01 No.NOTE - 2(i) All work shall be carried out only by authorised Rep of OEM and using all genuine spare parts supplied by OEM only, in this regard an MOU between OEM and the Contractor must be perform, A copy of the same MOU shall be uploaded with the tender document in cover - 1 (Tech Bid).(ii) Contractor should be responsible of proper functioning of all the machine.(iii) Batteries for the UPS if required shall be paid sepretaly in respective schedule.(iv) Contractor through OEM shall be responsible for repair and replacement of all defective parts of the equipment as per OEM recommendation during entire comprehensive maintenance period.(v) Preventive maintenance of all systems on monthly basis and upkeep of log book.(vi) Attending all complaints within 24 working hours intimated by Engr-in-Charge.(vii) Field service report shall be maintained and submitted to the Engr-in-charge after expiry of every month and before submission of RAR .(viii) The rates quoted by the contractor shall deemed to be inclusive of necessary T&P etc.(ix) A damage of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by Engr-in-Charge.(x) Contractor also displays his contact number near UPS System and complaint shall be attended immediately within time frame given in particular specification. (ix)Every month Technician shall check serviceability of UPS and serviceability report of system shall be submitted by the contractor.
2Dismanling all connection,Repair, Refixing, configuration, and testing of the internal communication Hot-Swappable Inverter/Rectifier Power Module for 3-Phase True Online Double Conversion UPS System upto 30 KVA Vertiv make UPS , including troubleshooting of communication ports, firmware update, replacement of faulty networking components, and verification of remote monitoring alerts/LIFE Services integration to ensure seamless data transmission to the UPS complete in all aspect all as specified and as directed.
3Dismanling all connection,Repair, Refixing, configuration, and testing of the Manual Maintenance Bypass (MMB) Switchgear/Board, designed to provide break-before-make switching for isolating the main UPS unit without interrupting power to the critical load for 3-Phase True Online Double Conversion UPS System upto 30 KVA Vertiv make UPS , including troubleshooting of communication ports, firmware update, replacement of faulty networking components, and verification of remote monitoring alerts/LIFE Services integration to ensure seamless data transmission to the UPS complete in all aspect all as specified and as directed.
4Supply & fixing in Replacement Sealed Maintenance Free 12V/65AH Batteries with suitable size terminal link upto 30 KVA UPS.
5Supply & fixing in Replacement bussmann series 160 amp BS88-4 HRC fuse suitable for 30 KVA UPS complete in all aspect all as specified and as directed.
6Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil.
7Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil all as specified and directed
8Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point all as specified and directed
9Supply & lay HDPE pipe 110 mm bore for laying of LT cables etc complete with all accessores all as specified and directed
10Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium of following size:-(a) 10 sqmm 4 core
11(b ) 25 Sqmm 4 core
12(c) 50 Sqmm 31/2 core
13(d) 70 Sqmm 31/2 core
14(e) 95 Sqmm 31/2 core
15(f)120 Sqmm 31/2 core
16M & L for repair to existing damaged surface of road by using necessary stone/PCC etc & tarcoal for making smooth surface of road complete matching with existing all as specified and directed.
17Supply and Fixing bus bar enclosure 800 mm x 600 mm x 200 mm made out of 3.00 mm thick CRCA steel sheet duly powder coated with provn of MCCB 200 Amp, 25 kA ,4 pole, thermal magnetic type based fitted in bus bar enclosure by using 200 Amp rated aluminium bus bar and RYB indication lamps duly protected by 2A SP MCB outdoor type by using suitable size of copper wire and bus enclosure shall be welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 ; Complete all as specified and as directed by the Engineer-in-charge.Note - Height of the enclouser from ground level shall not be less than 0.5 meter .
18Supply and Fixing bus bar enclosure 800 mm x 600 mm x 200 mm made out of 3.00 mm thick CRCA steel sheet duly powder coated with provn of MCCB 100 Amp, 25 kA ,4 pole, thermal magnetic type based fitted in bus bar enclosure by using 200 Amp rated aluminium bus bar and RYB indication lamps duly protected by 2A SP MCB outdoor type by using suitable size of copper wire & bus bar enclosure shall be welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 ; Complete all as specified and as directed by the Engineer-in-charge.Note - Height of the enclouser from ground level shall not be less than 0.5 meter .
19Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed.Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
20Material and labour for providing skilled electrician for maintenance of MAFI/Airfield Lighting system to Air force CSR section, Chabua Note :- (a) Digging, repairing or replacing the cables supplied by Air Force Chabua, relaying and closing of the trenches for the Air Field Lighting System.(b) Epoxy/heat sink jointing of underground cables.(c) Earth work, masonry and concrete works required for repair of light points.(d) Supporting minor repairs of 11 KV/400 Volt Transformer and HT switch gear.(e) Support in repair and maintenance of earthing system.(f) Cleaning of dust from AFLS and water accumulation from inset lights and CI box trenches Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58365853
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 27-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement Of Three Phase Ups System With Allied Works And Maintenance Of Mafi Afls/Czech/Afls At Af Stn Chabua Under Ge (Af) Chabua
Basic Detail
Tender No 863
Bidding Type Tender
Location
City Dibrugarh
State Assam
Key Dates
Publish Date 04 Nov 2026
Submission Date 27 Nov 2026
Open Date 04 Dec 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
BOQ_894225.xls
c93aec43-139b-447d-9c76-617979e4fbd8.html
generalpage.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_894225.xls

html

c93aec43-139b-447d-9c76-617979e4fbd8.html

pdf

generalpage.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender