Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #58365846

Tender For Provision Of Standby Supply For Communication Station At Cg Enclave Under Ge(I) (Cg) Goa

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
17.40 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
3 days left
EMD
34800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Standby Supply For Communication Station At Cg Enclave Under Ge(I) (Cg) Goa

BOQ

Name of Work:- PROVISION OF STANDBY SUPPLY FOR COMMUNICATION STATION AT CG ENCLAVE UNDER GE(I) (CG) GOA
Sl. No. Item Description
1Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an output of 100 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz supply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with inbuilt fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following.
2(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) Radiator with blower fan or heat exchanger with guard.(b) Pipe coupling for engine cooling system piping.(c ) Corrosion inhibitor coolant(d) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(e) Fly wheel housing and fly wheel to suit alternator.(f) Engine bearing mechanism in fly wheel housing.(g) Shut off coil with safeties for LLOP/HWT/over speed.(h) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows.(l) Battery charging alternator.
3(m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap.(n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of 30 gauge for the entire length of exhaust pipe.(o) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(p) Interconnecting copper cabling of adequate capacity batteries control.(q ) Fuel pipe class STIC 1\\" /1.5\\" /2\\" dia - 01 lot(r) Self starter 12 volts DC.(s) Electric operated electronic governor.(t) Fuel injection pump.(u) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:-(i) 12v -24V Battery as per OEM instruction(ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(v) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Over speed stop
4(v) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design along with AVM pads.(w) Battery:-12V-24 volts, as per OEM recommendation maintenance free battery conforming to IS:14257 with leads & terminals (Make- Exide/Amaron).(x) Fuel tank: 12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) Isolator panel with 100 amp MCCB(ab) Auto logic panel for automatic stat(b) Alternator: Alternator suitable rated for 100 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conforming to IS: 13364(part-1) MAKE: KOEL GREEN / STAMPFORD /CROMPTON/KIRLOSKAR/GREAVES(c) Acoustic Enclosure:- M & L for acoustic enclosure for the above 100 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.
5(d) AMF Control panel:- Factory fabricated cubicle type, indoor type, IP-43, AMF control panel,(e) AMF control circuit with 4 pole MCCB 160 Amps - 2 nos, with ultimate breaking capacity Icu-16 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts ,-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(f) Digital load manager : Three phase 4 wire indicating V, I, PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(iv) Bottom gland plate for incoming and outgoing cables.(v) Circuit diagram plate.Note : DG set should be as per CPCB -4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.
6Material and labour for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 m below ground level and connected to GI earth strip of size 32 x 6mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection (upto 7.5m long) & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.Note: On completion of the work/job the Contractor is to perform earth resistance tests for each earthing job in the presence of the Engineer-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Department till the results are satisfactory.
7Supply, lay, testing of LT under ground XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor suitable for 1100V grade cross sectional area 70 sqmm, 3.5 core laid in trenches etc complete all as specified and as directed.
8Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in soft disintegrated rock/ laterite rock etc complete all as specified and as directed.
9Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any strata complete all as specified and as directed.
10Removing excavated material to a distance not exceeding 50m, depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
11Supply and lay riddle sand in trenches for cable protection complete all as specified and as directed.Note: Punned thickness only will be measured & paid.
12Supply and laying un re-inforced precast concrete cable cover, class LV type-I, flat size 250mm x 150mm x 40mm in trenches over and across the cable complete all as specified and as directed.
13Supply and lay/ fix GI pipe light grade 80mm dia with all fittings and laid in trenches/ fixing on wall/pole with suitable size MS clamp for cable protection etc complete all as specified and as directed.
14Supply ,installing, testing and commissioning ,factory made and tested CPRI approved LT panel board out door type, hood on top, weather, vermin proof, platform mounted, suitable for 415 Volts, 3 Phase 4 wire 50 HZ AC supply system all as specified and directed, with necessary bus bar arrangement with insulated aluminium bus bar 200 Amps rating installed on porcelain insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tappings, copper control wiring of required size, the panel shall be dust and vermin proof,IP-54 class protection and made of 3.15 mm CRCA mild steel with 40x40x6mm angle iron frame, angle iron support of 40x40x6mm with 0.6m above ground level and 0.4m grouted in ground/PCC floor with necessary earthwork excavation hinged doors, front & rear opening and locking arrangement(including provision of 65mm Godrej(freedom)lock with 2 keys)and duly powder coated on the out side and inside including provision of PCC platform 100mm thick with PCC 1:4:8 type D-2 using 40 mm graded aggregate one metre around the panel board, cable gland and lugs for incoming and outgoing cable etc. Independent chambers to accommodate complete all as specified and directed including the following accessories:-
15Incomer(a) MCCB with thermal & adjustable type 4 pole 200 Amps, 50 Hz, 415 V, 25 KA - 01 Nos ,Outgoing (a) MCCB, 4 pole, 100 Amps, 50 Hz, 415 Volts, 16 KA - 02 Nos (1 Working + 1 Spare)(b) MCCB, 4 pole, 63 Amps, 50 Hz, 415 Volts, 16 KA -02 Nos(c) MCB, TP, 32 Amps, 50 Hz, 415 Volts -01 NosDigital Weekly Programmable Time Switch -1 No.3 Phase LED display, Digital Ammeter 0 to 200 Amps Class 1.0 – 01 No3 Phase LED display Digital Voltmeter 0 to 500 Volts, Class 1.0 – 01 NoIndicator lamp set (R,Y,B) - 01 Set Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58365846
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 17.40 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Standby Supply For Communication Station At Cg Enclave Under Ge(I) (Cg) Goa
Basic Detail
Tender No 8682/Goa/E8
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 04 Nov 2026
Submission Date 25 Nov 2026
Open Date 02 Dec 2026
Finance
Tender Value 17.40 Lakhs
Tender Fee 500
EMD 34800
Exemption Not Available
Document List
8682TENDERPAGES.pdf
917459e7-5c3c-44bd-aaef-6a06075e3086.html
BOQ_894230.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

8682TENDERPAGES.pdf

html

917459e7-5c3c-44bd-aaef-6a06075e3086.html

xls

BOQ_894230.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender