Tender For Supply/Fixing Of 150 Ltr Capacity 02 No Water Cooler, 4 Kva Steblizer, Construction Of Water Cooler Cage And Cabling Work Dismentling And Repairing Of 2 No. 30 Mtr Height High Mast, Repairing Of 200 Watt Flood Light Of High Mast, 120Watt L
Tender Overview
Project Description
Tender for Supply/Fixing Of 150 Ltr Capacity 02 No Water Cooler, 4 Kva Steblizer, Construction Of Water Cooler Cage And Cabling Work Dismentling And Repairing Of 2 No. 30 Mtr Height High Mast, Repairing Of 200 Watt Flood Light Of High Mast, 120Watt Led Street Light 20 No, Replacement Of Damage Cable For High Mast 2 Nos, Supply/Fixing Of 110 To 120 Watt 30 Nos Led Street Light And Other Related Work Etc At Nmy Talpura-Jhansi (Distt- Jhansi)( Note :- Rate Are Without Gst, Gst Will Be Paid Extra 18% )
BOQ
| Sl. No. | Item Description |
| 1 | Supply of 150 LTR capacity Usha model No. SS 104 with refrigerator R-22 having cooling capacity 150 Ltr. With extra large stainless steel body with water tap 2 no. complete in all respects. GEM |
| 2 | Supply of 4 KVA Blue Star make stabilizer range 140-280 with plug top complete in all respects. N.S. |
| 3 | P/F following capacity 63 Amp. TP&N disconector fuse switch unit inside the existing pannel board with ISI marked HRC fuses including drailling holes in cubical pannel making connetion etc as requried 2.1.2 |
| 4 | Installation and commissioning of water cooler including comnnection complete in all respects. N.S. |
| 5 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade in existing masonary open duck as directed by Engineer- In charge complete in all respect inculding axcavation and rifling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 10sq mm 2 core 20e.1.2 |
| 6 | Supply and fixing of power plug with 20A/250 volt flush type switch and 5 pin 20A/250V flush type universal socket in suitable M.S. box of 175mm x 50 mm Size with phenolic laminated bakelite sheet cover 3 mm thick fixed with brass machine screw and cup washer. 1.21.3+1.21.5 |
| 7 | Construction of 2 M X 1.5 M X 2.10 M water cooler cage made out of 50x50x5 mm MS angle iron with 10 SWG welded wire mesh of size 1x2 galvanized G.I. sheet of 24 SWG on roof top and side to protect the cooler from rain. The foundation of cage shall be of 0.15 M I 1.2.4 cement concrete base and brick work in 1.6.12 and 4 mm thick and plaster in 1.2.4 plain including painting with aluminium paint. The jcd include supply of all materials labou TP required for proper completion of work. CIVIL SHEDULE |
| 8 | Supply and fixing of chlorinated polybinyl chloride CPVC wash out pipe of 40 mm dia CPVC pipe for wastage water drain from water cooler connection complete in all respact DSR 18.9.5 (563.05) |
| 9 | Supply and fixing of brass stop cock of approved make complete in all respects. DSR Civil 2023 V-2 18.16.1 (353.25) |
| 10 | Supply and fixing of brass bib cock of approved make complete in all respects. DSR Civil 2023 V-218.15.1 (353.25) |
| 11 | Supply and fixing of uplasticised PVC connection pipe with brass unions 30cm lenth 15mm dia pipe fitting including all matrial complete in all respects. DSR Civil 2023 V-2 18.21.1.1 (85.00) |
| 12 | Supply and fixing of chlorinated polybinyl chloride CPVC of 15 mm dia CPVC pipe for water cooler fittings, clamps including all matrial, Labour etc. Complete in all respact DSR Civil 2023 V-2 18.9.1 (244.70) |
| 13 | Supply and burying safe earthing Electorde T-19 (Hot Dip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25, terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Gavanized up to 100 mircon filled with crystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaning capacity along with 30 cm squre C.I. frame with hinged cover & masonry housing (from electode terminal to switch board , cost of 25 x 3 G.I. strip will be extra) Make: As approved in U.P.P.W.D. & C.P.R.I. Certified 725 A |
| 14 | Supply and fixing of one number 8 SWG G.I. wire in 15 mm. dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. 721 |
| 15 | S/F of surface/flush mouthing 4 way SPN distributionboard with additional metal door without MCB complete in all respects and as directed at site. CAT A 1022 A |
| 16 | Supplying and fixing 5 A to 32 A rating 240/415 Volt, 10 KA ,\\"C\\" curve miniature circuit breakers suitable for inductive load as following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required. single pole DSR E/M2025 ,2.10.1 |
| 17 | S/F of 2 mtr high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical. The cage have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron etc. 12sqmm 1142 |
| 18 | Supplying and fixing 5 A to 32 A rating 240/415 Volt, 10 KA ,\\"C\\" curve miniature circuit breakers suitable for inductive load as following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required. double pole ,DSR E/M 2025 ,2.10.3 |
| 19 | Supply and hosting of sintax or equivalent high density polythylene seamless of piece mould tank complete in all respect Jal Nigam |
| 20 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade in on wall surface as directed by Engineer- In charge complete in all respect inculding axcavation and rifling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 16sq mm 4 core 20c.1.9 |
| 21 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade in on wall surface as directed by Engineer- In charge complete in all respect inculding axcavation and rifling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 10sq mm 2 core 20c.1.2 |
| 22 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at dept of 750mm below gorund level over a cushion of 75mm thick sand all round at procteted with burnt bricks on side and on top as directed by Engineer- In charge complete in all respect inculding axcavation and rifling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 50sq mm 3.5 core 20a.1.12 |
| 23 | S/F of LED street light potted driver set suitable for 120W complete in all respect. GEM |
| 24 | S/F of LED street light potted driver set suitable for 102 W complete in all respect. GEM |
| 25 | S/F of Surge Protection Device (SPD) for LED lights. GEM |
| 26 | Dissmentling of high mast |
| 27 | Refixing of high mast |
| 28 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect. 634 |
| 29 | S/F of GI pipe 100mm dia DSR – E/M –2025– 15.13.3 |
| 30 | P/F following capacity 100 Amp. TP&N disconector fuse switch unit inside the existing pannel board with ISI marked HRC fuses including drailling holes in cubical pannel making connetion etc as requried 2.1.3 |
| 31 | Supply and Wiring of submains with 2 nos. of 4 sq. mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge. 289 A |
| 32 | Supplying installation, testing and commissioning of street light LED fixture powder coated pressure die cast aluminium body with built-in or separate driver as per the requirement with driver efficiency > 85% input voltage 140-270 volt, AC frequency 50/60 hz, operating temperature range -5°C to 50°C, internal surge protection of 5KV L,N,E as per IEC 61000-4-5, driver efficiency is >85%, THD <10% as per IEC 61000-3-2, P.F >0.95, IP-66, IK-10, CRI is > 70, under voltage and over voltage protection, EMI - EMC as per CISPR-15, lenses for beam angle as per IESNA type 1/2/3 as per the width of the road and the project requriment, sutable for 2 fit in upto 65mm dia pipe (lifetime LED, driver, electrical. Circuitry) of minimum 50000 burning hours with 70% initial lumen maintain till life end as per LM80, extrapolation as per ASTM 2111 report CCT 3000 Kelvin/ 4000 Kelvin/ 5700 Kelvin/ 6500 Kelvin as per ANSI bin, SDCM, standard deviation color matching is <5, maximum powder composition should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect, I/C, external connection with 1.5mm FRLSH/ HFFR PVC insulated copper conductor single core cable and earthing ETC as required with minimum 5 year OEM warranty system lumen efficiency >135 LM/ watt output LM79 and LM80 test report and all testing required for LEDs fixture as per BIS shall be submitted, safe size and CCT shall be as. Approved by Engineer-in-Charge, as per requirement, thermal management, heat sink of aluminium housing such that LED junction temperature shall not rise above 90 degree Celsius. DSR 8.14.16 12 , 120 watt DSR 8.14.16 |
| 33 | S/F of following capacity of automatic street light cubical control panel paintd with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractor, HRC fuse,isolating switch metering instrument & instrument box with CTs etc.in case of TPN,complete in all respect. 25A TPN 807 e ii Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender