Tender For Replacing The Existing 11Kv Indoor Vcb Panels Of Megawin Make With A New 11Kv, 1250A Indoor 10 Panel Set At 33Kv Substation Paravur
Tender Value
5.58 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
6 days left
EMD
14000
Bank guarantee accepted
Document Fee
1416
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kollam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacing The Existing 11Kv Indoor Vcb Panels Of Megawin Make With A New 11Kv, 1250A Indoor 10 Panel Set At 33Kv Substation Paravur
BOQ
| Sl. No. | Item Description |
| 1 | Doing outdoor/indoor cable termination of 1x500 mm2 11KV XLPE cable very carefully observing directions of manufactures and departmental staff including crimping of socket(cost index(e) : 1.3132 included in Rate) |
| 2 | Loading 1x500 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers.(cost index(e) : 1.3132 included in Rate) |
| 3 | Unloading 1x500 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulation as per the direction of department officers.(cost index(e) : 1.3132 included in Rate) |
| 4 | Doing outdoor/indoor cable termination of 3x300 mm2 11KV XLPE cable very carefully observing directions of manufactures and departmental staff including crimping of socket(cost index(e) : 1.3132 included in Rate) |
| 5 | Dismantling the cables from panels by dismantling of cable glands fixing the cable rigidly for the Termination of cables in panel as per direction of departmental staff at site 12/7/6 core 2.5 sqmm cable (using gland of size 25mm) |
| 6 | Doing termination of all sizes of PVC insulated copper control cable 2.5 mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site.(cost index(e) : 1.3132 included in Rate) |
| 7 | Doing termination of all sizes of PVC insulated copper control cable 4.0 mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., using cable tie and cable tie neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site.(cost index(e) : 1.3132 included in Rate) |
| 8 | Dismantling 1 x 500 sq mm 11kV XLPE cables in trench including drawing through pipes wherever necessary and lead to storage place |
| 9 | Unmounting carefully 3x 300 mm2 indoor cable termination from the existing panel and kept carefully without damaging end |
| 10 | Unpacking at the place of storage and transporting 11KV indoor VCB/SF6 switchgear panel and its accessories to the place of erection and erecting after fixing foundation bolts by chipping concrete wherever necessary, tightening, keeping lines and levels taking all safety precautions including erection of potential transformers as per the direction of departmental officers.(cost index(e) : 1.3132 included in Rate) |
| 11 | Interconnection of panels and 11KV bus bars after opening covers, earthing, inter panel wiring, etc. and making ready for commissioning of breaker as per the direction of the departmental officers.(cost index(e) : 1.3132 included in Rate) |
| 12 | Unmounting one 3x300 mm2 XLPE outdoor cable end termination from the structure very carefully without causing any damages as directed by the departmental officers.(cost index(e) : 1.3132 included in Rate) |
| 13 | Disconnecting of panels,11Kv busbars, opening covers, earthing, inter panel wiring, etc. and making ready for storage to a safe distance as per the direction of departmental officers at site. |
| 14 | Dismantling from the place of Erection and transporting 11Kv indoor VCB/SF6 switch gear panel and its accessories to a safe distance after removing foundation bolts by chipping concrete wherever necessary, loosening, keeping lines and levels taking all safety precautions including dismantling of potential transformers as per the direction of departmental officers at site. |
| 15 | Supplying aluminium cable tags punching number and alphabets up to 7 digits and binding to cable using copper wire including cost of all materials as per the direction of Board Officials at site.(cost index(e) : 1.3132 included in Rate) |
| 16 | Laying 3 x 300 sq mm XLPE cables in trench including drawing through pipes wherever necessary.(cost index(e) : 1.3132 included in Rate) |
| 17 | Unmounting carefully 1x500 mm2 outdoor/indoor cable termination from the existing panel and kept carefully without damaging end |
| 18 | Mounting one 3x300 mm2 XLPE outdoor cable termination of structures very carefully without causing any damage to the drilling holes wherever necessary as directed by the departmental officers(cost index(e) : 1.3132 included in Rate) |
| 19 | Mounting one 3x300 mm2 XLPE indoor cable termination of structures very carefully without causing any damage to the drilling holes wherever necessary as directed by the departmental officers(cost index(e) : 1.3132 included in Rate) |
| 20 | Loading 3x300 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers.(cost index(e) : 1.3132 included in Rate) |
| 21 | Unloading 3x300 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulation as per the direction of department officers.(cost index(e) : 1.3132 included in Rate) |
| 22 | Laying 1 x 500 sq mm XLPE cables in trench including drawing through pipes wherever necessary .(cost index(e) : 1.3132 included in Rate) |
| 23 | Mounting one 1 x 500 mm2 outdoor / indoor cable termination of structures very carefully without causing any damage to the drilling holes wherever necessary as directed by the departmental officers(cost index(e) : 1.3132 included in Rate) |
| 24 | Glanding LT / DC cable of various sizes after removing insulation, armour etc. and making necessary holes on gland plates numbering cable etc. complete including supply of gland numbering plate etc.(cost index(e) : 1.3132 included in Rate) |
| 25 | Levelling, Cutting and fixing in position departmentally supplied MS Chequered plate 6 mm, 10 mm or 12mm thick in suitable length and width including providing lifting legs and suitable holes for lifting including grinding sides and corners etc. complete.(cost index(e) : 1.3132 included in Rate) |
| 26 | Laying of departmentally supplied GI strip/Copper strip of suitable size including cleaning and neatly bending of strips ,cutting, removing of metal/earth in the yard and burying earth strip to the required depth re-doing the yard metalling as per the direction of the departmental officers.(cost index(e) : 1.3132 included in Rate) |
| 27 | Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip & other end of the strip with yard structure at 2 points 50mm apart each welding points having 50mm length and 6mm thick on both sides & end of the strip including the charges for connecting the strip with structure using bolted joints as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.(cost index(e) : 1.3132 included in Rate) |
| 28 | Drilling holes in yard structure(cost index(e) : 1.3132 included in Rate) |
| 29 | Cutting of steel angle in yard structure erection(cost index(e) : 1.3132 included in Rate) |
| 30 | Uncoiling 4/2 core 2.5sqmm control cable (armored or unarmored) from cable drums and cutting to required length and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessary and cable marker at both ends of cable as per direction of departmental staff at site.(cost index(e) : 1.3132 included in Rate) |
| 31 | Uncoiling 5/4/3/2 core 4sqmm control cable(armoured or unarmoured) from cable drums and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessary and cable marker at both ends of cable as per direction of departmental staff at site.(cost index(e) : 1.3132 included in Rate) |
| 32 | Uncoiling 12/7/6 core 2.5 sq mm control cable (armoured and unarmoured) from cable drums and cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefully including for providing loops wherever necessary and cable marker, at both ends of cable as per direction of departmental staff at site.(cost index(e) : 1.3132 included in Rate) |
| 33 | Termination of cables in panel by using cable glands of fixing the cable rigidly by any means as per direction of departmental staff at site charges include for providing necessary suitable hole in the gland plate etc. 4/2 core 2.5 sq mm cable/4/2 core 4 sq mm cable (using gland of size 16-22mm)(cost index(e) : 1.3132 included in Rate) |
| 34 | Dismantling the cables from panels by dismantling of cable glands fixing the cable rigidly for the Termination of cables in panel as per direction of departmental staff at site 4/2 core 2.5 sq mm cable/4/2 core 4 sq mm cable (using gland of size 16-22mm) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender