Power Government Departments Closing in 28 days TDR #58363530

Tender For Tender**: Construction Of 220 Kv Gis Substation Majra & Associated 220 Kv Line And Residential Colony

Issued by Government Departments · Dehradun, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Dec 2026
28 days left
EMD
1.99 Crore
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Tender**: Construction Of 220 Kv Gis Substation Majra & Associated 220 Kv Line And Residential Colony

BOQ

Name of Work:- Tender**: Construction of 220 kV GIS Substation Majra & associated 220 kV line and residential colony
Sl. No. Item Description
1Please Enable Macros to View BoQ information Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 220 kV GIS Substation Majra & associated 220 kV line and residential colony” Contract No: PTCUL/E-Tender/C&P-II/SS-21/2026-27
2 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NOTE:- The bidder has to fill the rates/details in green cells only NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SI. No. Description of Material Item Code / Make Qty. Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P (without GST) Unit Freight Packing Forwarding Unloading & Stacking Insurance for transit cum 30 days storage RS P (Without GST) VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
3Price Schedule-A (Supply ) for ( 220/132kV GIS Substation Mazra, Dehradun )
4Transformer
5160 MVA, 220/132/11 kV, Three phase Transformer including first filling of oil, alongwith Fibre Optic Temperature Measurement System and all related equipments.
6Online DGA Multigas type for above Transformer
7Nitrogen Injection Fire Prevention & Extingusihing System
8Oil Storage Tank
9Oil sampling Bottle
10Station Transformer
11630KVA, 33/0.433KV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil)
12245kV GIS Equipments
13245kV, SF6 gas insulated Transformer Bay Module each comprising of SF6 gas insulated Circuit Breaker, Current Transformer, two bus-bar disconnectors one with grounding switch and one without grounding switch, one disconnector with safety grounding switch, high speed fault acting earth switch, SF6 gas monitoring system for complete bay, LCC, three 1-phase SF6 ducts and SF6/Air Interface to connect to 220/132/11kV, 160MVA Transformer and accessories with GIS etc. for complete transformer bay module.
14245KV, SF6 gas insulated Feeder Bay Module each comprising of SF6 gas insulated circuit breaker, current transformer, two bus-bar disconnectors one with grounding switch and one without grounding switch, line disconnector with safety grounding switch, high speed fault acting earth switch, SF6 gas monitoring system for complete bay, LCC, SF6/Cable Termination, Indoor Terminations kit/ bushing suitable for 1200sq. mm XLPE cable and accessories with GIS etc. for complete feeder bay module.
15245KV, SF6 gas insulated, metal enclosed Bus Bars each enclosed in bus enclosures running along the length of the switchgear to interconnect each of circuit breaker bay module. Each bus-bar set shall be complete with voltage transformer complete with safety grounding switch.
16245KV, SF6 gas insulated Bus Coupler Bay Module comprising of SF6 gas insulated circuit breaker, current transformer, two disconnectors with safety grounding switches, SF6 gas monitoring system for complete bay, LCC etc.
17245kV AIS Equipments
18245 kV CVT
19Junction box for above 245kV CVT
20216 kV Lightning Arrester with counter
21245 kV BPI
22Miscellaneous Materials (Insulators Strings / Disc Insulators, Hardwares, Conductor, Bus-Bar materials, Cable Trays, Bay MB, Clamps, Connector including equipments connectors and all accessories etc.) for 220kV Side.
23145kV Equipment
24145kV SF6 Circuit breakers (3 Ph.)
25145kV 800/400/1 (5 Core) Current Transformer (1 Ph.) with Junction Box
26145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box
27145kV (3 Ph.) Isolators
281250A, Tandem Isolator
291250A, Isolator without E/S
30120kV Surge Arrestors
31145kV Bus Post Insulators
32Miscellaneous Materials (Insulators Strings / Disc Insulators, Hardwares, Conductor, Bus-Bar materials, Cable Trays, Bay MB, Clamps, Connector including equipments connectors and all accessories etc.) for 132kV Side.
3336KV AIS Equipments
3433kV BPI
3533kV LA outdoor type
36Miscellaneous Materials (Hardwares, Poles, Cable Trays, Conductor, Clamps, Connector including equipments connectors and all accessories etc.) for station Transformers
3733kV Insolator/ Air Break Switch for Station Transformer
38Complete Substation Automation System including hardware and software for the substation & remote control stations alongwith all necessary associated equipments as per Technical Specifications and Detailed Engineering.
39Bay Control Units (to be installed in Control Panel)
40220kV System
41132kV System
42Online Monitoring, Data Acquisitionand ABT Analysis System
43ABT meters 0.2S Cl with TCP/IP, Optical Communication Port (to be installed in Control Panel)
44Industrial Grade Network Switch -8 Port, unmanaged
45UPS 2 KVA online with 30 Min back up on 100% load
46DCU & Accessories
47Workstation : Application & Database server
48Database - Microsoft SQL Server Edition (Latest)
49MS office - Standard edition
50MacAfee Virus Scan Enterprise Desktop Edition - 3 year
51Local Energy Monitoring Software - Professional edition
52Lan cable ( average one roll per S/S 300 Meters)
53PVC conduit Pipe - 3/4\\"
54Enclosure for Lan Switch
554G/5G Data enable SIM
56220 KV Control and Relay panel
57Circuit Breaker Control Panel
58With Auto Reclose
59With out Auto Reclose
60Line Protection Panel (Main 1+Main 2)
61Bus Bar Protection Panel (Bay Segregated decentralised architecture)
62220kV bus bar protection panel for Main-1 and Main-2 bus
63Transformer Protection Panel (HV side)
64PLCC for 220KV Line feeder
65Line Traps
662000A, 0.5 mH, 40 kA
67Coupling device ( Phase to Phase )
68HF Cable
69Carrier Equipment
70Speech + Protection 1 & 2
71Speech + Data
72Protection Coupler
73Time synchronisation equipment /GPS Clock (to be installed in SAS Panel)
74132 kV Control and Relay panel
75Circuit Breaker Control Panel
76With out Auto Reclose
77Transformer protection panel
78For 220/132kV ( LV side)
79Testing & Maintenance Equipment
80Insulation Tester Meter 15kV Multirange (Motorized)
81Thermo Vision Camera
82Automatic Capacitor and Tan Delta measuring kit
83Digital Multi Meter
84Leakage Tester (Tong type)
85Selective Level Meter
86Signal Generator
87Micro-ohm meter
88Gapless zinc oxide LA tester
89Oil BDV Kit 0-100 KV
90Gas Evacuating and refilling Plant for 220kV GIS
91Gas Leakge Monitor
92Circuit Breaker Analyser
93Portable Partial discharge monitoring system
94Dew Point Meter
95Battery Earth Fault Locator
96Primary Injection Set 2000 Amp
97Relay Test Kit
98Gas Mask
99D-Spanner set, Ring-Spanner set & Torque Wrench set. Each set shall be a complete set including all standard sizes.
100Insulating Gloves & Helmets
101Hydraulic Ladder Battery Operated (Rechargable) upto 300kgs capacity & 10 Mtrs height
102Spliced ladders 5mtr. & 10mtr.
103Spliced ladders 20mtr.
104Polyamide or Braided white nylon ropes 12mm, 14mm & 20mm of each type
105Rubber mat in Control room, Battery Room & LT Panel Room etc. as per Site requirements
106Shock treatment chart & artificial respiratory system
107First-aid box complete with first filling of required medicines, instruments and tools
108Danger / Man on line / Break-Down boards of appropriate size
109Rain coat, Gum boot and Safety Harness Belt with adequate straps
110Air-conditioner and Ventillation system
111Split AC (Capacity-2T)
112Ventillation system for 220kV GIS Hall
113Miscellaneous items
114Air Curtain for Control Room Building
115Interactive Screen for Control Room Building conference room
116Bay Marshling Kiosk (BMK)
117LT Switchboard
118415V Main Switchboard
119415V ACDB
120220V DCDB
12150V DCDB
122Batteries
123220V, 500AH
12448V, 300AH
125Battery charger system
126220V, 100Amps Float Cum Boost Charger
12748V, 60Amps Float Cum Boost Charger
128250kVA, 440V DG set alongwith AMF Control panel
129Fire Prevention & Extinguishing System
130Fire Alarm System for 220 kV GIS Hall & Control Room Building
131CO2 Type Fire Extinguisher 9 kgs
132CO2 Type Fire Extinguisher 4.5 kgs
133Mechanical Foam Type Fire Extinguisher 9 Ltrs
134Bucket Stand (including 6 Buckets with sand fill) and Sand filled Drum (half size)
135Illumination sytem
136LED Lights for Control Room / Store Room / Offices Illumination with complete fittings
137LED Lights for Switchyard Lighting with complete fittings, Junction Box & mounting accessories
138Solar Light System for Street Light (LED Type Lights) with Pole and other mounting accessories
139LED Lights for 220kV GIS, High Bay type with complete fittings
1401.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc.
141Power cables Aluminium (XLPE)
1423.5cx300 Sq.mm
143Power cable Aluminium (PVC)
1443.5cx70Sq.mm
1453.5cx35Sq.mm
1464cx16 Sq.mm
1474cx6 Sq.mm
148Control cable Copper (PVC)
1492Cx2.5Sq.mm
1504Cx2.5Sq.mm
1516Cx2.5Sq.mm
15210Cx2.5Sq.mm
153220kV Power Cable and accessories
154220kV XLPE Copper Power Cable of size 1 X 1200 sq.mm.
155220kV Outdoor Termination kit for above 1 X 1200 sq.mm cable (3 Nos.)
15633 kV Power Cable and accessories
15733kV XLPE Copper Power Cable for Auxiliary Transformer of size 1 X 185 sq.mm.
15833kV Outdoor Termination kit for above 1 X 185 sq.mm cable (3 Nos.)
159Grounding/Earthing system
16040mm MS rod for earthmat
16140mm MS 03 metre Electrodes
16240mm 03 meter deep driven pipe electrode (treated pit)
163GS Flats 75 x 12mm size
164GS Flats 50 x 6mm size
165Steel structure
166Lattice structure (Main Structures, Auxiliary Equipments Structures & Lightning Mast Structure)
167Pipe structure (Auxiliary Equipments Structure)
168EOT Crane
169EOT Crane for 220KV GIS Room (5 Ton)
170Moveable ladder of suitable capacity for 220 KV GIS Room
171Mandatory spares as per List indicated in Section \\"Mandatory spares\\" of Technical Specifications for following items
172220/132/11 kV Transformer
173245kV GIS CB
174245kV VT GIS Type (3 Nos)
175245kV CT GIS Type (3 Nos)
176245kV Isolators & ES GIS Type
177216kV Surge Arrestor (3 Nos)
178245kV Outdoor Termination Kit (SF6 to Air Type) (3Nos.)
179132kV CB
180132kV CT (3 Nos)
181132kV CVT (3 Nos)
182132kV Surge Arrestor (3 Nos)
183132kV Isolators & ES
184llumination system
185Optic fibre cable
186Fire fighting
187Battery
188Battery charger
189Relay & Protection panels
190Substation Automation
191LT Switchgear
192Common Spares, maintenance
193DG Set
194245 KV CVT Outdoor Type (3 Nos)
195Price Schedule-A (Supply ) for ( Constrction of LILO of 220 kV Jhajra-Harrawala Line at proposed 220 kV Substation Majra Dehradun with Under ground Cable )
196Design, manufacturing & supply of 220 kV 1200 sq. mm. Single Core XLPE insulated Copper Cable ( 6+1 Spare ).
197Supply of 6.6 KV 300 Sqmm. Sheath bonding Cable
198Supply of Polymer type outdoor termination kit suitable for 220 kV 1200 Sq.mm Copper Cable (for monopole).
199Three Phase earthing link box without SVL.
200Single Phase earthing link box with SVL.
201Single Phase earthing link box without SVL.
202Supply of polymer type Lighting Arrester suitable for 220 KV 1200 Sq.mm. cable with surge counter meter (for monopole)
203Supply of route marker (@ 50 Meter interval
204Supply of HDPE Pipes (250 mm dia)
205Pipe Earthing for termination kit & Lighting Arrester
206Warning tape in buried trench
207Supply of earth continuity Conductor of 1.1 KV 1Cx300 Sq. mm.(for earthing)
208Supply of Ms flat 75x12 mm Earthing material
209Supply of Ms round 40 mm for earthing (having 3 mtr. length)
210Design, Fabrication and supply of Galvanized 220 kV D/C type tested Utility Monopole complete in all respect suitable for termination of cable with Deviation angle (2 deg.-30 deg.).
211Supply of 220 KV C type Galvanized steel lattice tower with Bolts, Nuts, flat washers, pack washers & Stub including. Body Extension (One No. S/C or D/C tower may be used as per site requriment)
212Supply of ACSR Deer Conductor (30/7/4.27 mm size)
213Supply of earth wire (7/3.67 mm size )
214Double tension fitting for ACSR deer Conductor suitable for 2x160 KN Disc Insulator
215Tension fitting for GS Earth wire 7/9 SWG
216Disc Insulator 160 KN
217Accessories for conductor & earth wire
218Vibration damper for Deer Conductor
219Vibration damper for GS earth wire 7/9 SWG
220Mid span compression joint for ACSR Deer Conductor
221Mid span compression joint for GS Earth wire 7/9 SWG
222Repair sleeves for ACSR Deer conductor
223Flexible Coppeer Bond (set of two)
224Supply of Tower Accessories
225Danger Plate
226Number Plate
227Phase Plate (set of three)
228Circuit Plate (set of two)
229Anti climbing device
230Pipe type earthing (set of two nos. for each tower) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 220 kV GIS Substation Majra & associated 220 kV line and residential colony” Contract No: PTCUL/E-Tender/C&P-II/SS-21/2026-27
231 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NOTE:- The bidder has to fill the rates/details in green cells only NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SI.No. Description of Material Item Code / Make Qty. Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P (without GST) Unit Freight Packing Forwarding Unloading & Stacking Insurance for transit cum 30 days storage RS P (Without GST) VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
232Price Schedule-B (Erection) for ( 220/132kV GIS Substation Mazra, Dehradun )
233Transformer
234160 MVA, 220/132/11 kV, Three phase Transformer including first filling of oil, alongwith Fibre Optic Temperature Measurement System and all related equipments.
235Online DGA Multigas type for above Transformer
236Nitrogen Injection Fire Prevention & Extingusihing System
237Oil Storage Tank
238Station Transformer
239630KVA, 33/0.433KV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil)
240245kV GIS Equipments
241245kV, SF6 gas insulated Transformer Bay Module each comprising of SF6 gas insulated Circuit Breaker, Current Transformer, two bus-bar disconnectors one with grounding switch and one without grounding switch, one disconnector with safety grounding switch, high speed fault acting earth switch, SF6 gas monitoring system for complete bay, LCC, three 1-phase SF6 ducts and SF6/Air Interface to connect to 220/132/11kV, 160MVA Transformer and accessories with GIS etc. for complete transformer bay module.
242245KV, SF6 gas insulated Feeder Bay Module each comprising of SF6 gas insulated circuit breaker, current transformer, two bus-bar disconnectors one with grounding switch and one without grounding switch, line disconnector with safety grounding switch, high speed fault acting earth switch, SF6 gas monitoring system for complete bay, LCC, SF6/Cable Termination, Indoor Terminations kit/ bushing suitable for 1200sq. mm XLPE cable and accessories with GIS etc. for complete feeder bay module.
243245KV, SF6 gas insulated, metal enclosed Bus Bars each enclosed in bus enclosures running along the length of the switchgear to interconnect each of circuit breaker bay module. Each bus-bar set shall be complete with voltage transformer complete with safety grounding switch.
244245KV, SF6 gas insulated Bus Coupler Bay Module comprising of SF6 gas insulated circuit breaker, current transformer, two disconnectors with safety grounding switches, SF6 gas monitoring system for complete bay, LCC etc.
245245kV AIS Equipments
246245 kV CVT
247Junction box for above 245kV CVT
248216 kV Lightning Arrester with counter
249245 kV BPI
250Miscellaneous Materials (Insulators Strings / Disc Insulators, Hardwares, Conductor, Bus-Bar materials, Cable Trays, Bay MB, Clamps, Connector including equipments connectors and all accessories etc.) for 220kV Side.
251145kV Equipment
252145kV SF6 Circuit breakers (3 Ph.)
253145kV 800/400/1 (5 Core) Current Transformer (1 Ph.) with Junction Box
254145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box
255145kV (3 Ph.) Isolators
2561250A, Tandem Isolator
2571250A, Isolator without E/S
258120kV Surge Arrestors
259145kV Bus Post Insulators
260Miscellaneous Materials (Insulators Strings / Disc Insulators, Hardwares, Conductor, Bus-Bar materials, Cable Trays, Bay MB, Clamps, Connector including equipments connectors and all accessories etc.) for 132kV Side.
26136KV AIS Equipments
26233kV BPI
26333kV LA outdoor type
264Miscellaneous Materials (Hardwares, Poles, Cable Trays, Conductor, Clamps, Connector including equipments connectors and all accessories etc.) for station Transformers
26533kV Insolator/ Air Break Switch for Station Transformer
266Complete Substation Automation System including hardware and software for the substation & remote control stations alongwith all necessary associated equipments as per Technical Specifications and Detailed Engineering.
267Bay Control Units (to be installed in Control Panel)
268220kV System
269132kV System
270Online Monitoring, Data Acquisitionand ABT Analysis System
271ABT meters 0.2S Cl with TCP/IP, Optical Communication Port (to be installed in Control Panel)
272Industrial Grade Network Switch -8 Port, unmanaged
273UPS 2 KVA online with 30 Min back up on 100% load
274DCU & Accessories
275Workstation : Application & Database server
276Database - Microsoft SQL Server Edition (Latest)
277MS office - Standard edition
278MacAfee Virus Scan Enterprise Desktop Edition - 3 year
279Local Energy Monitoring Software - Professional edition
280Lan cable ( average one roll per S/S 300 Meters)
281PVC conduit Pipe - 3/4\\"
282Enclosure for Lan Switch
2834G/5G Data enable SIM
284Integration of Existing station metering system with centrlized data system including all hardware and software required.
285220 KV Control and Relay panel
286Circuit Breaker Control Panel
287With Auto Reclose
288With out Auto Reclose
289Line Protection Panel (Main 1+Main 2)
290Bus Bar Protection Panel (Bay Segregated decentralised architecture)
291220kV bus bar protection panel for Main-1 and Main-2 bus
292Transformer Protection Panel (HV side)
293PLCC for 220KV Line feeder
294Line Traps
2952000A, 0.5 mH, 40 kA
296Coupling device ( Phase to Phase )
297HF Cable
298Carrier Equipment
299Speech + Protection 1 & 2
300Speech + Data
301Protection Coupler
302Time synchronisation equipment /GPS Clock (to be installed in SAS Panel)
303132 kV Control and Relay panel
304Circuit Breaker Control Panel
305With out Auto Reclose
306Transformer protection panel
307For 220/132kV ( LV side)
308Air-conditioner and Ventillation system
309Split AC (Capacity-2T)
310Ventillation system for 220kV GIS Hall
311Miscellaneous items
312Air Curtain for Control Room Building
313Interactive Screen for Control Room Building conference room
314Bay Marshling Kiosk (BMK)
315LT Switchboard
316415V Main Switchboard
317415V ACDB
318220V DCDB
31950V DCDB
320Batteries
321220V, 500AH
32248V, 300AH
323Battery charger system
324220V, 100Amps Float Cum Boost Charger
32548V, 60Amps Float Cum Boost Charger
326250kVA, 440V DG set alongwith AMF Control panel
327Fire Prevention & Extinguishing System
328Fire Alarm System for 220 kV GIS Hall & Control Room Building
329CO2 Type Fire Extinguisher 9 kgs
330CO2 Type Fire Extinguisher 4.5 kgs
331Mechanical Foam Type Fire Extinguisher 9 Ltrs
332Bucket Stand (including 6 Buckets with sand fill) and Sand filled Drum (half size)
333Illumination sytem
334LED Lights for Control Room / Store Room / Offices Illumination with complete fittings
335LED Lights for Switchyard Lighting with complete fittings, Junction Box & mounting accessories
336Solar Light System for Street Light (LED Type Lights) with Pole and other mounting accessories
337LED Lights for 220kV GIS, High Bay type with complete fittings
3381.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc.
339Power cables Aluminium (XLPE)
3403.5cx300 Sq.mm
341Power cable Aluminium (PVC)
3423.5cx70Sq.mm
3433.5cx35Sq.mm
3444cx16 Sq.mm
3454cx6 Sq.mm
346Control cable Copper (PVC)
3472Cx2.5Sq.mm
3484Cx2.5Sq.mm
3496Cx2.5Sq.mm
35010Cx2.5Sq.mm
351220kV Power Cable and accessories
352220kV XLPE Copper Power Cable of size 1 X 1200 sq.mm.
353220kV Outdoor Termination kit for above 1 X 1200 sq.mm cable (3 Nos.)
35433 kV Power Cable and accessories
35533kV XLPE Copper Power Cable for Auxiliary Transformer of size 1 X 185 sq.mm.
35633kV Outdoor Termination kit for above 1 X 185 sq.mm cable (3 Nos.)
357Grounding/Earthing system
35840mm MS rod for earthmat
35940mm MS 03 metre Electrodes
36040mm 03 meter deep driven pipe electrode (treated pit)
361GS Flats 75 x 12mm size
362GS Flats 50 x 6mm size
363Steel structure
364Lattice structure (Main Structures, Auxiliary Equipments Structures & Lightning Mast Structure)
365Pipe structure (Auxiliary Equipments Structure)
366EOT Crane
367EOT Crane for 220KV GIS Room (5 Ton)
368Operation & Maintenance (O&M) of substation and familiarization of PTCUL staff with the installed system for a period of 06 Months.
369Price Schedule-B (Erection) for ( Constrction of LILO of 220 kV Jhajra-Harrawala Line at proposed 220KV Substation Majra Dehradun with Under ground Cable )
370Detailed Survey, Laying of 220 KV 1200 Sq. mm. cable ( 6+1 spare) including excavation of ground for min. 1.9 meter depth/as per the site requirement for trefoil arrangement and constraints in normal or hard soil Sand/brick installed, roads or any other site condition/underground conditions refiling, raining of earth etc. with suitable size RCC/HDPE pipes as cover on strategic locations for complete machanical protections of the Cable showing all danger sign etc. in the ground and above on the route including structure installation, earthing, bounding shielding size testing and commissioning in all respects.
371Complete Route Survey, Check Survey including trial pits, Profiling, Alignment etc. including prepration of Tower schedule, pegmarking of locations etc.
372Earth work excavation by mechanical means (hydraulic excavator) or manually means
373Laying of 1200 Sq.mm. 220 KV Cable including all the works related to laying of cable like excavation, sand filling, RCC slab, warning tape, backfilling, removing of extra excavated earth etc. complete in all respect including testing & commissioning of cable system.
374Providing and laying of position cement concrete or specified grade including the cost of centering, shuttering, material, forming, concreting, curing of water and cost of CC for 1:3:6 (excluding the cost of Reinforcement of slab).
375Providing and laying of position cement concrete or specified grade including the cost of centering, shuttering, finishing, forming, concreting, curing of water and cost of cement 1:1.5:3 (excluding the cost of Reinforcement of slab).
376Reinforcement for RCC work including cost of all size of bars, straightening, cutting, bending, placing in position and binding all complete upto plinth level cods twisted bars.
377Brick work with commen brunt clay F.P.S. brick of class designation 7.5 in foundation & plinth as per requirement cement mortar 1:4 ( 1 cement : 4 Coarse sand ), work also include plaster of walls of ratio 1:6 & curing of water.
378Installation of polymer type outdoor termination kit suitable for 220 KV 1200 Sq.mm Copper Cable (for monopole) including earthing etc.
379Pipe earthing and connecting with 75x12 mm earth strip
380Installation of Polymer/Porcelain Type Lightening Arrestor, Surge counter.
381Erection of route marker @ 50 Meter interval
382Installation of single phase link boxes
383Installation of three phase link boxes
384Laying of MS Flat 75x12 mm including cutting, bending and all welding work
385Laying of MS round 40 mm including reiser cutting, bending and all welding work
386Dismentaling of existing 220 KV \\"A\\" type tower of Khodri- Jhajhra Line
387Release of existing conductor of 220 KV single circuit Khodri - Jhajhra Line including all associated work for destringing.
388Laying, Stringing Tensioning, clamping, jointing etc. complete with ACSR Deer conductor including hoisting of insulators and fitting of vibration dampers, jumpers at tower etc. for complete route for S/C Deer conductor.
389Release of existing Earth wire of 220 KV single circuit Khodri - Jhajhra Line including all associated work for destringing.
390Laying, Stringing Tensioning, clamping, jointing, jumperting etc. complete with single earth wire 7/9 SWG including fixing of clamps and all accessories.
391Setting of Achor bolt and setting of stub including all foundation work but excluding the cost of concreting and excavation.
392Excavation of foundation pits for Utility Monopoles and Lattice structure tower including all earthwork, backfilling and levelling etc. in
393Concrete for foundation pits for Steel structure tower including all material, shoring, andshuttering forming ( if any ), concreting and curing by water including cost of cement for concrete (cost of supply of MS steel bar is not to be included).
394M 20 (1:1.5:3)
395M 10 (1:3:6)
396M 15 (1:2:4)
397Utility Monopoles erection including all work above ground level excluding hoisting of insulator & fitting of danger, number & phase plate but including punching of bolts and also include erection of power cable on steel pole.
398Super structure erection of 220 KV \\"C\\" type tower, tower part, tower extention (complete) with bolts & nuts and including all work above ground level excluding hoisting of insulators & fitting of danger plate, number plate, phase plate, circuit plate, anti climbing devices and bird guards, but including punching of bolts.
399Grounding work with Pipe type earthing and backfilling excluding cost of earthing material( Set of Two) for lattic structure and monopole.
400Erection of Tower Accessories
401Danger Plate
402Number Plate
403Phase Plate ( set of 3)
404Circuit Plate ( set of 2 )
405Anti climbing device
406MS Steel bars for reinforcements
407Price Schedule-B (Civil Work) for ( Construction of 220/132 KV GIS S/S Majra, Dehradun ) Works on turn key basis
408Civil Works as per Technical specification
409Buildings
410Construction of 220KV GIS Control and Relay room (Plinth area to be measured) Ground Floor ( Minimum Ceiling height-4.50M)
411Construction of 220KV GIS room (Plinth area to be measured) Ground Floor ( Minimum Ceiling height-9.00M)
412Construction of cable vault room for 220 kV GIS Control and Relay room (Plinth area to be measured) (Minimum Ceiling height-2.9 M)
413Construction of Electrical Room, Battery room (Plinth area to be measured) Ground Floor ( Minimum Ceiling height-4.50M) (In Control Room Building)
414Construction of SCADA Room, Conference Room & office (Plinth area to be measured) First Floor ( Minimum Ceiling height-4.50M) (In Control Room Building)
415Construction of E.E. Office (Plinth area to be measured) Second Floor ( Minimum Ceiling height-4.50M) (In Control Room Building)
416Lift power operated centre opening doors and AC variable voltage and variable frequency control for 8 person capacity, 1.5 metre per/second speed and for G+4
417Security guard room ( Minimum Ceiling height-3.00M)
418Construction of foundation of following structures including excavation and back filling of earth, CC/RCC works, reinforcement , supply & Fixing foundation bolts etc. complete.
419220 kV Switch yard
420220 kV CVT foundation
421220 kV LA foundation
422220 kV WT foundation
423Foundations for Bus Duct support structure.
424Foundation for 160 MVA Transformer including construction of common sump well.
425Plinth for 630 KVA Transformer
426Bushing foundations
427Construction of DG set plinth
428132 kV Switch yard
429132 kV Gantry Foundation
430132 kV CT Foundation
431132 kV PT Foundation
432132 kV LA Foundation
433132 kV Isolator Foundation
434132 kV Tandom Isolator Foundation
435132 kV Circuit Braker
43633 kV BPI
437RCC Cable trenches with trench covers (all Sections) including all type of crossing and all metalic work to support cables and trench covers.
438600 mm size trench with minimum depth 600 mm
4391050 mm size trench with minimum depth 1000 mm
440Burried cable Trench for 33 KV XLPE Cable for TransformerLV to 33 KV GIS
441Fire Protection Wall
442Construction of one sump with suitable capacity sludge pump and pumphouse , control panel for drainage of water from cable trenches, also including supply of one spare pump
443Cement concrete roads including all type of crossings.
4445.00 metre wide
4453.75 metre wide
446Secuirty (Chain link) Fencing 3.6 m high alongwith Gate
447Secuirty (Chain link) Fencing 3.6 m high
448Gate (5.0M wide)
449Storm water drainage including culverts/ RCC hume pipe
450AC junction box for Switchyard lighting
451Switch yard turfing and antiweed treatment including levelling and dressing of area.
452Construction of rain water harvesting system with 02 Nos. recharge structures with bore wells etc.
453Construction of 3.0 m high boundary wall having RCC columns at 3.0 m C/C and brick panels upto 2.4 m from FGL and 600 mm concertina wire, as per DSR item no.16.53, fencing above these panels with 2 no. RCC bands at FGL and Top including required foundations including construction of gate including toe wall / Retaining wall
454Development works (B)
455Land development including necessary cutting /filling and construction of all retaining walls for complete switch yard area maintaining required.
456Earth filling in entire substation area including cost of earth. Earth to be obtained from outside the corporation area including its cartage, ramming , watering, dressing in 20 cm thick layer etc. complete.
457Excavation work by mechanical means(Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Ordinary rock (DSR Item No.- 2.9.1)
458Extra for every additional lift of 1.5 m or part thereof in. Ordinary or hard rock (DSR Item No 2.26.2)
459Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (DSR Item No. 4.1.3)
460Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (DSR Item No.- 4.1.8)
461Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). (DSR No. 5.1.2)
462Reinforced cement concrete work in walls ( any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). (DSR Item No. 5.2.2)
463Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (DSR Item No.-5.3)
464Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footing, bases of columns, etc. for mass concrete. (DSR Item No. 5.9.1)
465Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landing, balconies and access platform (DSR Item No. 5.9.3)
466Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts. (DSR Item No. 5.9.6)
467Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls. Under 20 cm wide (DSR Item No. 5.9.16.1)
468Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Cold twisted bars (DSR Item No. 5.22.3)
469Brick work with F.P.S. bricks of class designation 7.5 in foundation and plinth in. Cement mortar 1:6 ( 1 cement : 6 coarse sand ) (DSR Item No- 6.1.2)
470Brick work with F.P.S. bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in. Cement mortar 1:6 ( 1 cement : 6 coarse sand ) DSR Item No.- 6.4.2)
471Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR ITEM No. - 10.25.2)
47212 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand) (DSR Item No.- 13.4.1)
47315 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand) (DSR Item No.- 13.5.1)
474Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete (DSR Item No.- 13.80)
475Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. (DSR Item No. - 13.62.1)
476Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mmwith tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR Item No.- 16.53)
477Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR Item No.- 7.1.1)
478Development of lawn including levelling and dressing, preparation of sand bed with appropriate good earth and manure mixing and planting of the best quality turfing grass
479Providing medium size flower pots including good earth with manure and plants as approved by Engineer-In-Charge
480Plantation of ornamental plants on the ground including making of appropriate size of pits. Filling of good earth including manure
481Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (DSR Item No.- 13.46.1)
482Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 40 mm dia nominal bore (DSR Item No.- 18.12.5)
483Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 50 mm dia nominal bore (DSR Item No.- 18.12.6)
484Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore (DSR Item No.- 18.13.1)
485Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore (DSR Item No.- 18.13.2)
486Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work ) 40 mm nominal bore (DSR Item No.- 18.46.5)
487Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work ) 50 mm nominal bore (DSR Item No.- 18.46.6)
488Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (DSR Item No.- 18.33.1)
489Price Schedule-B (Civil Work) for ( Construction of Residential Colony & Associated Development works at 132 kV S/s Majra, Dehradun)
490Civil Works as per CPWD Technical specification
491Construction of Residential Type - IV& V Stilt portion of Building having RCC framed structure with minimum floor height of 3.6 metre including raft base,fire fighting with wet riser and sprinkler system,automatic fire alarm system with addressable system, internal electric connections & installations , power wiring & plugs installations, electrical & civil external service connections, local body approval charges, flooring, putty, painting & installation of door and window,ACP,outer finishing material & other civil works etc.
492Construction of Residential Type - IV& V Building having RCC framed structure with minimum floor height of 3.0 metre ,fire fighting with wet riser and sprinkler system,automatic fire alarm system with addressable system, internal water supply & sanitary installations, internal electric connections & installations , power wiring & plugs installations, electrical & civil external service connections , local body approval charges, lightening conductors, telephone conduits, flooring, putty, painting & installation of door and window,ACP,outer finishing material & other civil works etc. (First floor to Seventh floor )
493Construction of Residential Type - IV& V Building having RCC framed structure with minimum floor height of 3.0 metre,fire fighting with wet riser and sprinkler system,automatic fire alarm system with addressable system, internal water supply & sanitary installations, internal electric connections & installations , power wiring & plugs installations, electrical & civil external service connections , local body approval charges, lightening conductors, telephone conduits & other civil works etc. (Eight floor to Tenth floor ) including machine room,mumty etc.
494Construction of Residential Type - III & II Stilt portion of Building having RCC framed structure with minimum floor height of 3.6 metre including raft base,fire fighting with wet riser and sprinkler system,automatic fire alarm system with addressable system, internal electric connections & installations , power wiring & plugs installations, electrical & civil external service connections, local body approval charges, flooring, putty, painting & installation of door and window, ACP,outer finishing material & other civil works etc.
495Construction of Residential Type - III & II Building having RCC framed structure with minimum floor height of 3.0 metre,fire fighting with wet riser and sprinkler system,automatic fire alarm system with addressable system, internal water supply & sanitary installations, internal electric connections & installations , power wiring & plugs installations, electrical & civil external service connections , local body approval charges, lightening conductors, telephone conduits, flooring, putty, painting, ACP,outer finishing material & other civil works etc. (First floor to Seventh floor )
496Construction of Residential Type - III & II Building having RCC framed structure with minimum floor height of 3.0 metre,fire fighting with wet riser and sprinkler system,automatic fire alarm system with addressable system,internal water supply & sanitary installations, internal electric connections & installations , power wiring & plugs installations, electrical & civil external service connections , local body approval charges, lightening conductors, telephone conduits flooring, putty, painting, ACP,outer finishing material & other civil works etc. (Eight floor to Tenth floor ) including machine room, mumty etc.
497Construction of Community centre Building having RCC framed structure with minimum floor height of 9.9 metre including raft base,fire fighting with wet riser and sprinkler system,automatic fire alarm system with addressable system, internal water supply & sanitary installations, internal electric connections & installations , power wiring & plugs installations, electrical & civil external service connections , local body approval charges, lightening conductors, telephone conduits flooring, putty, painting & installation of door and window,False ceiling, ACP,outer finishing material & other civil works etc.(ground floor ) (minimum depth of foundation 3.0metre)
498DEVELOPMENT WORKS(B)
499Horticulture Operations including 300 mm earth filling, grassing, tree plantation/shrubs and potted plants
500Boundary wall with 1500 mm high wall and 600 mm high MS grill including 2100 mm high steel gates at every 100 metres. (With brickwork structure and RCC band at ground level and coping)
501External Sewerage
502Cement Concrete Pavement with vacuum dewatered concrete
503Supplying, installation, testing and commissioning of STP/ETP of appropriate technology including civil works (except plant room ),tetiary treatment etc. for the building /campus plant size upto 50KLD
504Passenger Lifts with power operated centre opening doors and AC variable voltage & variable frequency controls passenger lifts speed 1.0 m/sec, 8 Persons, G+9 power operated with glass door & other accessories etc.
505Supplying, installation, testing and commissioning of 33kV/0.433kV or 11 kV/0.433kV substation equipment comprising HT panel, dry type/Oil type transformers, HT cable, bus trunking from transformer to LT panel, LT panels, automatic power factor correction panel, active harmonic filters, TVSS (transient voltage suppression system), SPD (surge protection system), essential panel, earthing, required inter-connections, substation safety equipments including LT cabling form substation to the buildings fed by the substation.
506Supplying, installation, testing and commissioning of DG sets, AMF Panel, bus ducting/cables from DG sets to essential panel, DG set enclosure room sound insulation/ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/ piping, DG set exhaust piping/ exhaust chimney as per CPCB norms, civil works connected with DG sets including foundation as required.
507Extra for synchronizing panels wherever required
508Supplying, installation, testing and commissioning of solar water heating system with heat exchanger type including electrical heater backup, make up water tank but without piping-100 litres capacity
509Supplying, installation, testing and commissioning of IP based CCTV system for building security comprising of PTZ/ fixed camera, cabling, digital recording, HD display system with minimum display of 5\\" x 8\\" per camera and hardware software support-For Indoor Only. (rate apllicable on total plinth area but CCTV coverage shall be limited to 15% of the total plinth area as per requirement)
510Supplying, installation, testing and commissioning of IP based CCTV system for building security comprising of PTZ/ fixed camera, cabling, digital recording, HD display system with minimum display of 5\\" x 8\\" per camera and hardware software support.-For external surveillance (rate apllicable on total plot area minus plinth area at ground floor)
511Supplying, installation, testing and commissioning of basic security system in the residential colony to include control room at the gate and intercom connection to each dwelling unit and IP based CCTV system to be installed at the entry and exit point, parking area, entry point of each dwelling unit and other common areas as required including CCTV control room, required under ground cabling,digital recording system and monitor with minimum display of 5\\" x 8\\" per camera in the control room.-intercom system (rate apllicable on plinth areaexcluding service/common areas).
512Supplying, installation, testing and commissioning of LED street/ compound/ high mast/ pathway/ landscape lighting for the entire campus.
513RCC Watertank (Underground Sump)
5141:4:8 (1 Cement : 4 coarse sand (zone-III) derived from naturalsources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources)
515Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5161:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
517Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
518Shuttering (Lintels, beams, plinth beams, girders, bressumers and cantilevers) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 220 kV GIS Substation Majra & associated 220 kV line and residential colony” Contract No: PTCUL/E-Tender/C&P-II/SS-21/2026-27
519 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) * Tender is of composite nature comprising of supply of goods and supply of services NOTE:- The bidder has to fill the GST AMOUNT on The green cells of AMOUNT COLOUM(4) ONLY. In case any discrepancy is observed in amount carried from BoQ1 & BoQ2 sheet as below, the value given in BoQ1 & BoQ2 sheet shall prevail. NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Particulars Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Pleas Enter ZERO Only AMOUNT VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
520Total Price Schedule-A (Supply) from BoQ1 sheet WITHOUT GST
521Total Price Schedule-B ( Erection, Civil Works and Devlopment Works ) from BoQ2 sheet WITHOUT GST
522Add GST* Amount on (Total of Price Schedule-A + Total of Price Schedule-B above) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only

AI Tender Summary

OUR REF NO 58363530
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 08-12-2026
Authority
Authority Name Power Transmission Corporation Of Uttaranchal Limited
Work Description Tender for Tender**: Construction Of 220 Kv Gis Substation Majra & Associated 220 Kv Line And Residential Colony
Basic Detail
Tender No PTCUL/CandP-II/SS-21/2026-27
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 04 Nov 2026
Submission Date 08 Dec 2026
Open Date 09 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 29500
EMD 1.99 Crore
Exemption Available
Document List
AnnexAofTQR.pdf
AnnexureA.pdf
bdd04f4d-b56d-4f76-924e-68d479d8bf7e.html
BOQ_120194.xls
PQRsheetPartI.xls
TenderDocument.pdf
Tendernotice_1.pdf
TScivilAndLine.rar
TSss1.rar
TSss2.rar
vendorregistrationform.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 28 days
Dec 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
pdf

AnnexAofTQR.pdf

pdf

AnnexureA.pdf

html

bdd04f4d-b56d-4f76-924e-68d479d8bf7e.html

xls

BOQ_120194.xls

xls

PQRsheetPartI.xls

pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

rar

TScivilAndLine.rar

rar

TSss1.rar

rar

TSss2.rar

pdf

vendorregistrationform.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender