Tender For Cleaning & Up-Keeping Of Chm Hospital, Chm Colony Including repair maintenace Of Water Supply And Providing Assistance For Different Works Required Day To Day Of Chm Under Hasdeo Area. (For One Year)Nit No.: Gm/Hsd/C/E-Tender/26-27/26 Dtd:
Tender Overview
Project Description
Tender for Cleaning & Up-Keeping Of Chm Hospital, Chm Colony Including repair maintenace Of Water Supply And Providing Assistance For Different Works Required Day To Day Of Chm Under Hasdeo Area. (For One Year)Nit No.: Gm/Hsd/C/E-Tender/26-27/26 Dtd: 03.11.2026Tender Id No.: 2026_Secl_367704_1
BOQ
| Sl. No. | Item Description |
| 1 | Providing and deployment of 01 (One) No. Semi-Skilled Manpower (with computer operation assistance) and 01 (One) No. Unskilled Manpower at the Civil Office, CHM for carrying out day-to-day office and field support activities, including data entry, document preparation, record maintenance, photocopying, movement of files, housekeeping, material handling, and other allied duties as directed by the Engineer-in-Charge. |
| 2 | Providing contractual assistance for comprehensive cleaning, sweeping, washing and mopping of the entire Central Hospital Building and its premises, including all rooms, wards, corridors, O.T., kitchen, canteen, chambers, offices, toilets, bathrooms, internal/external roads, pathways, drains, inspection chambers, septic tanks, sewer lines, etc., in three shifts per day, complete as directed by Engineer-in-Charge. Total 28 Nos. of Unskilled manpower per day |
| 3 | Supply of Chemicals : Natural floor cleaner of approved brand. |
| 4 | Supply of Chemicals : Toilet Cleaning of approved brand. |
| 5 | Supply of Chemicals : Nepthalene ball of approved brand. |
| 6 | Supply of Chemicals : Glass cleaner of approved brand. |
| 7 | Supply of Chemicals : Room/Air freshner of approved brand. |
| 8 | Cleaning and overhauling of septic tank for 10 to 20 users, including removal of sludge, stacking/disposal at a suitable place, removal and refixing of the existing slab, complete in all respects as directed by the Engineer-in-Charge. |
| 9 | Cleaning of choked inspection chambers, S.W. pipes, W.C. pans, etc., including removal and refixing of existing slabs, complete in all respects as directed by the Engineer-in-Charge. |
| 10 | Cleaning of main drain of size 230 mm and above, including removal of sludge and stacking/disposal at a suitable place, removal and refixing of slabs, complete in all respects as directed by the Engineer-in-Charge. |
| 11 | Cleaning of small drains of size below 230 mm, including removal of sludge and stacking/disposal at a suitable place, removal and refixing of slabs, complete in all respects as directed by the Engineer-in-Charge. |
| 12 | Cleaning of road berms including the space upto boundary of the quarters, front and back side including disposal of garbage as directed by the Engineer-in-Charge. |
| 13 | Providing contractual assistance for spraying of Anti-Malaria Liquid (KO-3) in the front and rear portions of residentialbuildings and Non-Residential Buildings (NRBs), including transportation of spraying machines, handling and mixing of chemicals, operation of equipment, and execution of all allied activities as directed by the Engineer-in-Charge, complete in all respects. |
| 14 | Providing and deployment of contractual manpower for operation and maintenance of Pyau during the summer season, including distribution of drinking water, cleaning and upkeep of the Pyau premises, handling of water storage arrangements, and other allied duties as directed by the Engineer-in-Charge, complete in all respects. |
| 15 | Removal/uprooting of unwanted vegetation/plants from the surface of building & disposal of same 50 mtr. lead. Including finishing surface, making good condition as per Instruction of Engineer In-Charge. |
| 16 | Cleaning of overhead water tanks (Sintex/RCC) including draining of water, removal of mud/sludge, scraping and cleaning of walls and floor, application of lime and bleaching powder on cleaned surfaces, complete with all labour, materials, tools and safety measures as per the instructions of the Engineer-in-Charge.. |
| 17 | Cleaning of sedimentation/storage tank, including washing/cleaning of the floor, removal of mud, dirt, water and sludge, draining out of accumulated water/mud/sludge, and scraping/clearing of the surface, excluding whitewashing, complete as directed by the Engineer-in-Charge (CHM Colony Tank). |
| 18 | Providing and deployment of contractual manpower for repairing damaged doors and windows of employees' quarters at CHM, and Non-Residential Buildings, including all necessary carpentry works, as per the instructions of the Engineer-in-Charge. (Total 01 Nos. Unskilled Manpower and 01 Nos. Semi-skilled Manpower per day) |
| 19 | Providing and deployment of contractual manpower for Valveman duties for running the drinking water supply system, including valve opening, valve closing, and other allied works, complete as per the instructions of the Engineer-in-Charge at CHM and MRS Township. (Total 03 Nos. Unskilled Manpower per day) |
| 20 | Supply of Ghadi Powder of approved brand as per Instruction of Engineer In-Charge. |
| 21 | Supply of Lifeboy Soap as per Instruction of Engineer In-Charge. |
| 22 | Supply of Soda as per Instruction of Engineer In-Charge. |
| 23 | Supply of Floor Wiper as per Instruction of Engineer In-Charge. |
| 24 | Supply of Seek, Coconut Jhadu as per Instruction of Engineer In-Charge. |
| 25 | Brick work with F.P.S. (non modular) clay fly ash bricks class designation 7.5 in foundation and plinth in : Cement Mortar 1:6 (1 cement : 6 coarse sand) |
| 26 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 27 | 12 mm cement plaster finished with a floating coat of neat cement: 1:4 (1 cement : 4 fine sand) |
| 28 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars |
| 30 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 31 | White washing with lime to give an even shade :Old work (one or more coats) |
| 32 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 33 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 34 | Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 35 | Providing and deployment of contractual manpower for welding and repair of damaged old pipelines, hinges, door frames, and other miscellaneous fabrication works at various locations under CHM, including necessary tools and plants, welding electrodes, hinges, and other incidental materials required for the work, complete as per the instructions of the Engineer-in-Charge. (Engaging 01 No. Unskilled Manpower and 01 No. Semi-skilled Welder per day.) |
| 36 | Providing and deployment of contractual manpower for carrying out day-to-day plumbing maintenance works, including attending complaints related to water supply lines, leakage repair, replacement of damaged taps, valves, pipe fittings, sanitary fixtures, and other miscellaneous plumbing works at CHM Colony, complete with necessary tools and plants and as per the instructions of the Engineer-in-Charge. (Engaging 01 No. Unskilled Manpower and 01 No. Semi-skilled Plumber per day.) |
| 37 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15 mm dia nominal bore |
| 38 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore |
| 39 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore |
| 40 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore |
| 41 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore |
| 42 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 100 mm dia nominal bore |
| 43 | Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms |
| 44 | Providing and fixing PTMT stop cock of approved quality and colour. 15 mm nominal bore, 86 mm long, weighing not less than 88 gms |
| 45 | Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 107 mm long, weighing not less than 110 gms |
| 46 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 47 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm |
| 48 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White |
| 49 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 80 mm diameter |
| 50 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 100 mm diameter Class I |
| 51 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore |
| 52 | Providing and fixing bolts including nuts and washers complete. |
| 53 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 54 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore |
| 55 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 15 mm nominal bore |
| 56 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20 mm nominal bore |
| 57 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25 mm nominal bore |
| 58 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 59 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 60 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 15 mm nominal outer dia Pipes |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 20 mm nominal outer dia Pipes |
| 63 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 25 mm nominal outer dia Pipes |
| 64 | Supply of floor cleaning machines, comprising Wet & Dry Vacuum Cleaner (WD-255), High Pressure Cold Water Cleaner (N-250), and Scrubber cum Drier Machine (GA-450, complete with all standard accessories required for proper operation, as per the directions of Engineer-Incharge. |
| 65 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender