Coal and Mines Boards / Undertakings / PSU Closing in 6 days TDR #58363118

Tender For Development Work Of Johar Asthan With Paver Block And Reinforced Cement Concrete Roof Shed At Dumaria Rehab Site Under Rajmahal Area.

Issued by Boards / Undertakings / PSU · Godda, Jharkhand
Tender Value
19.89 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
6 days left
EMD
24900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Godda → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Work Of Johar Asthan With Paver Block And Reinforced Cement Concrete Roof Shed At Dumaria Rehab Site Under Rajmahal Area.

BOQ

Name of Work:- Development work of Johar asthan with paver block and RCC roof shed at Dumaria rehab site under Rajmahal Area.
Sl. No. Item Description
1Item Description/ Heading
2Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
3Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
4Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
5Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
6Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
712 mm cement plaster of mix : 1:6 (1cement : 6fine sand)
8Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
9Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
10Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
11Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
123D painting including paints with paninter chareges including GST.
13Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
14Supplying and stacking at site.53 mm to 22.4 mm size stone aggregate
15Supplying and stacking at site.Stone screening 11.2 mm nominal size (Type B)
16Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
17Providing and laying factory made coloured chamfered edge cement concrete paver blocks of required strength, thickness & size/shape, made by table vibratory method using PU mould laid in required colour & pattern over 80 mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand-in footpath, parks, lawns,drive ways or light traffic parking etc complete as per manufacturer's specifications & direction of Engineer-in-Charge. 60mm thick C.C paver block of M-35 grade with approved colour, design & pattern.
18Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
19Supplying fixing concrete/rcc seating arragement.
20Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil.
21Filling in foundation or plinth by silver sand in layers not exceeding 150mm as directed and consolidating the same by through saturation with water, ramming complete including the cost of supply of sand (payment to be made on measurement of finished quantity)
22Single brick flat soling of picked jhama bricks including ramming and dressing bed to in proper level and filling joints with local sand.
23Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
24Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
25Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
26Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
27Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
28Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
29Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
30Centring and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns.
31Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
32Centring and shuttering including strutting, propping etc. and removal of form work for : Columns, Pillars, Piers, Abutments, Posts and Struts
33Centring and shuttering including strutting, propping etc. and removal of form work for : Suspended floors, roofs, landings, balconies and access platform
3412 mm cement plaster of mix : 1:6 (1cement : 6fine sand)
356 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
3612 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand)
37Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
38Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
39Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
40Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
41Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
42Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. : 25 mm nominal outer dia Pipes
43Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms
44Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58363118
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 19.89 Lakhs
LAST DATE 14-11-2026
Authority
Authority Name Eastern Coal Fields Ltd
Work Description Tender for Development Work Of Johar Asthan With Paver Block And Reinforced Cement Concrete Roof Shed At Dumaria Rehab Site Under Rajmahal Area.
Basic Detail
Tender No ECL/RJML/AGM/AE(C)/ e-Ten/26-27/204 Dt-03.11.2026
Bidding Type Tender
Location
City Godda
State Jharkhand
Key Dates
Publish Date 03 Nov 2026
Submission Date 14 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 19.89 Lakhs
Tender Fee Ref. Documents
EMD 24900
Exemption Not Available
Document List
b12edfba-d1e4-4f4b-91e9-ebf329ea373a.html
BOQ_381147.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

b12edfba-d1e4-4f4b-91e9-ebf329ea373a.html

xls

BOQ_381147.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender