Tender For Tender For Restoration Of Ht And Lt Line Due To Heavy Rain & Thunderstorm During June-July-August 2026 At Various Locations Under Esd Kudail Under Ed Hpsebl Baijnath.
Tender Value
2.07 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
0 days left
EMD
2075
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kangra → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Tender For Restoration Of Ht And Lt Line Due To Heavy Rain & Thunderstorm During June-July-August 2026 At Various Locations Under Esd Kudail Under Ed Hpsebl Baijnath.
BOQ
| Sl. No. | Item Description |
| 1 | Restoration of HT line of 11KV Chobin Feeder near Khumb Factory on Dt. 23.08.2026 |
| 2 | Prov. S/T Pole 09 Mtr. Long. |
| 3 | Prov. RCC Muff with concrete filling (2000 mm). |
| 4 | Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) * (3 Nos. conductors) * (2 Nos. sides). |
| 5 | 11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure. |
| 6 | Prov. HT Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure). |
| 7 | Prov. Egg Insulator |
| 8 | Prov. M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]. |
| 9 | Prov. G.I. Wire 8 SWG |
| 10 | Cross Arm: [Channel Iron (100x50x5 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure |
| 11 | Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures |
| 12 | Erection Charges for Steel Tubular poles. |
| 13 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 14 | Re-Sagging Charges single continuous GI wire. |
| 15 | Erection of HT Stay sets. |
| 16 | GST on Erection |
| 17 | Restoration of HT line at Marh on Dt. 19.08.2026 |
| 18 | Prov. S/T Pole 09 Mtr. Long. |
| 19 | Prov. RCC Muff with concrete filling (2000 mm). |
| 20 | 11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure. |
| 21 | Prov. HT Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure). |
| 22 | ACSR/AAAC 7/3.15 mm |
| 23 | Prov. Egg Insulator |
| 24 | Prov. M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]. |
| 25 | MS Channel Iron 100x50x5 Length in mtrs 1500 |
| 26 | MS Angle Iron : 50X50x6, Length:(1800 mm x 2 No. ) |
| 27 | Prov. Full clamp |
| 28 | Prov. Stay Wire 7/3.15 mm |
| 29 | Erection Charges for Steel Tubular poles. |
| 30 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 31 | Erection Charges for sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 32 | Erection of HT Stay sets. |
| 33 | Re-Sagging Charges single continuous GI wire. |
| 34 | Fixing of Jumper |
| 35 | GST on Erection & Transportation |
| 36 | Restoration of LT line at Ghar Bahi and Chobu on dated 19.08.2026 |
| 37 | Prov. LT Stay Set. |
| 38 | Prov. Stay Wire 7/3.15 mm |
| 39 | Erection Charges for LT Stay Set |
| 40 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 41 | Re-Sagging Charges single continuous GI wire. |
| 42 | Fixing of Jumper |
| 43 | GST on Erection & Transportation |
| 44 | Restoration of LT line at Marh on dated 19.08.2026 |
| 45 | Prov. LT Stay Set. |
| 46 | Prov. Stay Wire 7/3.15 mm |
| 47 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 48 | Re-Sagging Charges single continuous GI wire. |
| 49 | Erection Charges for LT Stay Set |
| 50 | Erection charges for fixing of Jumpers. |
| 51 | GST on Erection & Transportation |
| 52 | Restoration LT line at Nohra in E-Section Kunsal on dated 25.07.2026 |
| 53 | Prov. AAAC 7/3.15 mm |
| 54 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 55 | Re-Sagging Charges single continuous GI wire. |
| 56 | Erection charges for fixing of Jumpers. |
| 57 | GST on Erection & Transportation |
| 58 | Restoration of LT line at Mandhol on dated 06.07.2026 |
| 59 | Prov. LT Stay Set. |
| 60 | Prov. Schackle Insulator |
| 61 | Prov. D-Iron |
| 62 | Prov. Stay Wire 7/3.15 mm |
| 63 | Re-Erection Charges for ST Pole |
| 64 | Erection Charges for LT Stay Set |
| 65 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 66 | Re-Sagging Charges single continuous GI wire. |
| 67 | Fixing of Jumper |
| 68 | GST on Erection & Transportation |
| 69 | Restoration of HT line at Kudail (Siyana-Simbal Spur) on dated 06.07.2026 |
| 70 | 11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure. |
| 71 | Prov. HT Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure). |
| 72 | Prov. M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]. |
| 73 | Prov. Full clamp |
| 74 | Prov. Stay Wire 7/3.15 mm |
| 75 | Re-Erection Charges for Pole |
| 76 | Erection Charges for HT Stay Set |
| 77 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 78 | Fixing of Jumper |
| 79 | GST on Erection & Transportation |
| 80 | Restoration of HT line at Girtholi (Bandian) on Dt. 30.07.2026 |
| 81 | Prov. S/T Pole 09 Mtr. Long. |
| 82 | Prov. RCC Muff with concrete filling (2000 mm). |
| 83 | Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) * (3 Nos. conductors) * (2 Nos. sides). |
| 84 | 11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure. |
| 85 | Prov. HT Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure). |
| 86 | Prov. Egg Insulator |
| 87 | Prov. M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]. |
| 88 | Prov. Stay Wire 7/3.15 mm |
| 89 | Prov. Full clamp |
| 90 | Prov. Half clamp |
| 91 | Cross Arm: [Channel Iron (100x50x5 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure |
| 92 | Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures |
| 93 | Erection Charges for Steel Tubular poles. |
| 94 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 95 | Re-Sagging Charges single continuous GI wire. |
| 96 | Erection of HT Stay sets. |
| 97 | GST on Erection |
| 98 | Restoration of HT line at Langu (Haar Sakri) on Dt. 04.06.2026 |
| 99 | Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) * (3 Nos. conductors) * (2 Nos. sides). |
| 100 | 11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure. |
| 101 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 102 | Re-Sagging Charges single continuous GI wire. |
| 103 | Fixing of Jumper |
| 104 | GST on Erection & Transportation |
| 105 | Restoration of LT line at Krishna Nagar on dated 04.06.2026 |
| 106 | Prov. S/T Pole 09 Mtr. Long. |
| 107 | Prov. RCC Muff with concrete filling (2000 mm). |
| 108 | Prov. LT Stay Set. |
| 109 | Prov. Shackle Insulator |
| 110 | Prov. D-Iron |
| 111 | Prov. Stay Wire 7/3.15 mm |
| 112 | Prov. AAAC 7/3.15 mm |
| 113 | Erection Charges for Steel Tubular poles. |
| 114 | Erection Charges for LT Stay Set |
| 115 | Erection Charges for Re sagging, stringing & binding with insulator of conductor 7/3.15mm |
| 116 | Re-Sagging Charges single continuous GI wire. |
| 117 | Fixing of Jumper |
| 118 | GST on Erection & Transportation Quantities are mentioned above are tentative and Actual Quantity shall be worked out after Check Survey to be carried out by the successful Tender and detailed Engineering and finalization of Tower location Chart.Payment shall be made as per Approved Bill of Material/Actual Quantities measured at site. Other Material like pole, conductor, stay set, shackle, D-iron, stay wire, half clamp, full clamp, pin insulator, GI , will be provided by HPSEBL Divisioanl store Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender