Drinking Water Supply and Sanitation Local Bodies Closing in 2 days TDR #58362332

Tender For Improvement Works To The Urban Public Health Centre Building At Vadavalli (Vnr Nagar) In Ward No.36, West Zone Roc No.340/2025/Md2

Issued by Local Bodies · Coimbatore, Tamil Nadu
Tender Value
49.90 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
2 days left
EMD
49900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Improvement Works To The Urban Public Health Centre Building At Vadavalli (Vnr Nagar) In Ward No.36, West Zone Roc No.340/2025/Md2

BOQ

Name of Work:- Improvement works to the Urban Public Health Centre building at Vadavalli (VNR Nagar) in Ward no.36, West Zone ROC No.340/2025/MD2
Sl. No. Item Description
1Providing cast in situ cement concrete 1:1 1/2 :3 (one cement, one and half M.Sand and three coarse aggregate) using 20mm size HBBG metal for 23 cm dia pile including cost of materials labour, hire charges for machinery for earthwork for forming 23cm dia borehole to the required depth before concreting excluding cost of steel reinforcement
2Earth work excavation in all kinds of soil including sand, silt, wet sand under water, black cotton, stiff black cotton, clay, hard stiff clay, hard red earth, murram, stoney earth, gravel and shales etc. excepting all kinds of rock and boulders exceeding 0.014 cum. in volume including rough dressing and dumping the excavated materials away from work site manually within 50m initial lead and 2m initial lift as per the direction of Engineer-in-charge
3Plain Cement concrete 1:4:8 (one cement, four sand and eight aggregate) using 40mm hard blue granite metal by volume for levelling course in foundation trenches manholes inspection chambers etc., including charges for scaffolding , shoring , strutting, bailing out water if necessary ramming , consolidating cuing etc., cost and conveyance of all materials complete in all respects complying with relevant standard specifications at all leads &lifts inside the building
4Random rubble masonry in cement mortar 1:5 mix with blue granite rough stones for foundation and basement
5Supplying and erecting CENTERING AND SHUTTERING with necessary supports for plane surfaces such as RCC SLABS, LINTEL SUNSHADES, etc., with all cross bracings using mild steel sheets etc., complete
6Supplying and erecting SHUTTTERING including necessary supports for plane surfaces such as RCC COLUMN etc., using Mild steel sheets of Suitable size and BG 10 stiffened with Welded mild Steel etc.,
7Supplying, fabricating and placing in position TMT/CTD rods for all RCC works including cost of steel and binding wire also in all floors complete complying with standard specification.
8REINFORCED CEMENT CONCRETE 1:1 1/2 :3 (One cement, one and Half sand and three aggregate) using 20mm gauge hard broken granite stone jelly for FOUNDATION and BASEMENT including laying Consolidating finishing curing etc., Complete Complying with Standard Specification
9Brick work in cement mortor 1:5 mix (one cement,five sand) using II class table moulded bricks to a size of 9\\"x4 3/8\\"x2 3/4\\" including cost and conveyance of all materials and labour charges for mixing the mortor, constructing, curing to required period and wherever the masonry projection is necessary for elevation shall be done with out extra cost etc complete as per std spn.
10Plastering with cement mortor 1:5 mix (1 part cement and 5 part sand) using 12mm thick
11Supplying and Fixing in position of STEEL DOOR & WINDOW using 20mm square rods at 15cm C/C and two baulstrades in one stepm centrally located and top welded to 25x 5mm flats fixing in the MS Pipe handrill and bottom fixed in step concrete firmly MS Flats of size 50mm x 6mm to be provided at the center of the balustrades connecting all the square rods to the entrote length of the balustrades including one coat of primer etc., Complete
12Daddoing the walls with first quality approved colour glazed tiles with printed design of 30x30x6mm laid in cement mortar 1:2 mix to 10mm thick and painting with white cement using 0.40kg/1m2 including finishing the jointing and painting flush with tiles surface etc., complete
13Flooring finishing with first quality design vitrified glazed tiles of all colours of size 600cm X 600cm X 6mm laid in cement mortar 1:3 mix to 20mm thick and painting with white cement using 0.30 kg/1m2 including finishing the jointing and painting flush with tiles surface etc., complete
14Flooring with Ceramic tiles in CM 1:3 Mix 20mm thk. of approved brand and colour including pointing with coloured cement etc complete
15Supply and laying of step tiles approved brand and colour in cm 1:20 mm thick including pointing with coloured cement etc complete
16Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. The window should be got approved from the Executive Engineer before use on work
17Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
18Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Door of casement type from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. The window should be got approved from the Executive Engineer before use on work
19Supply and Filling of well gravel layer by layer including watering consoldating etc complete
20Supply and laying of Chips including cost of materials and labour charges for laying etc complete
21Supply and erection of 1.20m dia with 50mm wall thickness and 30cm height RCC rings including cost of rings , loading , unloading and labour charges for erection of rings etc complete
22Supply and fixing of RCC precast slab for 1.20m dia including cost of slab , loading , unloading and labour charges for fixing in position and pointing with cm 1:3 mix etc complete
23Supplying and laying TAMIN paver block providing and laying of 80 mm thick high strength tybe conforming IS 15658 - 2006 of TAMIN paver block in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub pase, stone dust cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers sweeping transporting loading unloading of laying paver block as per standard specification
24Supply and Fixing of European make colour water closet of standard size and approved brand including labour charges for fixing in position etc complete
25Supply and Fixing of colour wash basin of standard size and approved brand including labour charges for fixing in position etc complete
26Supply and fixing of PVC doors with frame and locking arrangements etc complete
27Painting with plastic emulsion paint two coats along with base coat of approved quality (ISI Standard) paint as per the standard specification. (The paint to be used should be got approved by the Executive engineer before use on work)
28PAINTING new IRON WORKS for doors, windows and Ventilators, Iron bars Weld mesh, wire mesh, screen, steel bars, flats and other similar works etc., with TWO COATS of approved first quality of synthetic enamel paint over a base coat of red oxide primer in all floors. The rate is inclusive of cost of all materials and labour, brushes and scaffolding charges etc., complete complying with standard specification. The paint to be used should be got approved by the Executive engineer before use on work.
29Supply and run off 2x1.5 sq.mm (22/0.3) PVC insulated SC unsheathed CU conductor of 1100V grade in rigid PVC pipe concealed in wall and ceilling with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable colour
30Supply and run off 2x4 sq.mm (56/0.3) PVC insulated SC unsheathed CU conductor of 1100V grade in rigid PVC pipe concealed in wall and ceilling with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable colour
31Wiring with 2x15 Sq.mm (22/0.3) PVC Insulated SC unsheathed CU conductor of 1100V grade in Suitable PVC rigid pipe concealed in wall and ceilling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A.F.T switch with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable colour PVC concealed light or fan point.
32Supply and Fixing of 4' 20W LED tube light fitting of approved brand including labour charges for fixing in wall and ceiling with necessaey accessories like clips,screw etc complete
33Supply and fixing of 1200mm (48\\") AC ceilling fan complete with energy saving fan of 28 watts, regulator with 0.3 meter down rod on the existing clamp of approved brand and quality etc., complete
34Wiring with 2x15 Sq.mm (22/0.3) PVC Insulated SC unsheathed CU conductor of 1100V grade in Suitable PVC rigid pipe concealed in wall and ceilling with PVC accessories in flush with wall with 150mm x100mmx113mm TW switch box with 3mm thick hylum sheet cover for 5A.3PIn non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable colour for concealed PVC plug point.
35Wiring with 2x4 Sq.mm (56/0.3) PVC Insulated SC unsheathed CU conductor of 1100V grade in Suitable PVC rigid pipe concealed in wall and ceilling with PVC accessories in flush with wall with 150mm x100mmx113mm TW switch box with 3mm thick hylum sheet cover for 15A.3PIn non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of concealed portion with suitable colour for concealed PVC Power plug point. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58362332
AUTHORITY Local Bodies
TENDER VALUE 49.90 Lakhs
LAST DATE 19-11-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Improvement Works To The Urban Public Health Centre Building At Vadavalli (Vnr Nagar) In Ward No.36, West Zone Roc No.340/2025/Md2
Basic Detail
Tender No E84/2026-Two cover
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 03 Nov 2026
Submission Date 19 Nov 2026
Open Date 20 Nov 2026
Finance
Tender Value 49.90 Lakhs
Tender Fee Ref. Documents
EMD 49900
Exemption Not Available
Document List
701c64fd-96ac-43c0-9b66-bbe0bc779284.html
BOQ_866348.xls
BUILDING.pdf
ITB.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

701c64fd-96ac-43c0-9b66-bbe0bc779284.html

xls

BOQ_866348.xls

pdf

BUILDING.pdf

pdf

ITB.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender