Tender For Construction Of 100 Seated Gents Hostel For Kats Ayurvedic College And Hospital Ankushpur , Berhampur As Per Letter No. 5930 Dtd. 04.08.2023 Of Directorate Of Ayush, Odisha Buildings.
Tender Overview
Project Description
Tender for Construction Of 100 Seated Gents Hostel For Kats Ayurvedic College And Hospital Ankushpur , Berhampur As Per Letter No. 5930 Dtd. 04.08.2023 Of Directorate Of Ayush, Odisha Buildings.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Nov-2026 | Change of Date | Date | 24-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation in all kinds of soil within 50 m linital lead and 1.50m initial lift including rough dressing breaking clods to maxikum 5cm to 7cm and laying in layers not exceeding 0.3M depth and as per OPWD Specification and direction of the Engineer-In-Charge. |
| 2 | Filling in foundation and plinth with excavated earth including watering and ramming as per OPWD Specification and direction of the Engineer-In-Charge. |
| 3 | Filling in foundation and plinth with sand including watering and ramming with cost, conveyance, royalty, taxes of all materials with all labour, T&P etc., complete as per the OPWD Specification and direction of the Engineer-in-charge. |
| 4 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the OPWD Specification and direction of the Engineer-in-charge. |
| 5 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 %) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge.. But excluding cost and conveyance of HYSD bar and binding wires and labour charges for straightening, cutting, bending etc. of HYSD Bar tying the grills and placing in proper position. - Column Base |
| 6 | Plinth Beam |
| 7 | Column S/s and Roof Beam - Ground Floor |
| 8 | First Floor |
| 9 | Second Floor |
| 10 | Lintel - Ground Floor |
| 11 | First Floor |
| 12 | Chajja - Ground Floor |
| 13 | First Floor |
| 14 | Second Floor |
| 15 | Roof Slab - Ground Floor |
| 16 | First Floor |
| 17 | Second Floor |
| 18 | Stair Case - Ground Floor |
| 19 | First Floor |
| 20 | Shelves - Ground Floor |
| 21 | First Floor |
| 22 | Supplying cutting, bending, binding & straightening coiled or bent up HYSD Bar of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of HYSD Bar and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for HYSD Bar only) etc. complete as per OPWD specification & direction of Engineer-in-charge.. Ground Floor |
| 23 | First Floor |
| 24 | Second Floor |
| 25 | Fly Ash Brick masonry in C.M. (1:6) using of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Foundation & Plinth |
| 26 | Super Structure - Ground Floor |
| 27 | First Floor |
| 28 | Second Floor |
| 29 | Fly Ash Brick masonry in C.M. (1:4) Superstructure using of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - First Floor |
| 30 | Second Floor |
| 31 | Providing 12 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 32 | First floor |
| 33 | Second Floor |
| 34 | Providing 16 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 35 | First floor |
| 36 | Second Floor |
| 37 | Supplying, fitting and fixing of M.S. grills, grill gates, M.S. gates, garage door, Steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar of 10mm as per approved drawing and design with cost of all labour, materials & T&P, sundries etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. |
| 38 | Synthetic Enamel painting two coats over a coat of primer to Iron work including cost of all materials and labour with T&P etc complete in all respect as per OPWD specification & direction of Engineer-in-charge- Ground Floor |
| 39 | First Floor |
| 40 | Second Floor |
| 41 | Supplying, fitting, fixing of polished Vitrified floor tiles in Floor of premium grade having thickness (8mm to 10 mm) confirming to IS 15622:2006 (Group-B la) of 600mmx600mm plain (ivory) laid on 20mm thick bed of cement mortar (1:4) and filling jointed with white cement of approved quality including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specicication & the direction of the Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) Make:Somany/ Jhonson/ Kajaria) - Ground Floor |
| 42 | First floor |
| 43 | Second Floor |
| 44 | Supplying, fitting, fixing of Industrial Vitrified floor tiles in Floor of premium grade having thickness 8mm to 10 mm confirming to IS 4457 of 300mmx300mm laid on 20mm thick bed of cement mortar (1:4) and filling jointed with white cement of approved quality including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification & direction of the Engineer-in-charge (Note- Sample of tiles shall be approved before procurement and use.)- Ground Floor |
| 45 | First Floor |
| 46 | Second Floor |
| 47 | Supplying, fitting, fixing of polished Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 15622:2006 (Group-B la) of 600mmx600mm plain (ivory) in Dados on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of tiles including cost, conveyance of all materials, cost of all labour, T&P etc. complete as OPWD specificaion per the direction of the Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) Make:Somany/ Jhonson/ Kajaria)Ground Floor |
| 48 | First floor |
| 49 | Second Floor |
| 50 | Supplying, fitting, fixing of dressed seasoned sal wood work framed and fixed wrought and put up) in trusses, purlines,frames of doors, windows, ventilabours and beams etc.with cost, conveyance, taxes, royalties of all materials & labour with T&P etc. complete in all respect-All Floor |
| 51 | Supplying,fitting and fixing of Stainless Steel of 304 grade in Hand Railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90 mtr. C/C and sainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification,buffing, polishing etc. with cost,conveyance,taxes of all materials,Labour,T&P etc. required for the complete in all respect as per OPWD specification & direction of Engineer-in-charge. - all Floor |
| 52 | Supply and fitting, fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality compete with frame, shutters and all fitting and fixtures,cost,conveyance,taxes of all materials,Labour,T&P etc. complete as per OPWD specification & direction of Engineer-in-charge.All floor |
| 53 | Finishing to exterior wall surface with 2 (two) coats of weather coat over coat of primer of approved shade and approved make to give an even shade including cost of all material of all materials and labour with T&P etc. completeas per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 54 | First floor |
| 55 | Second Floor |
| 56 | Distempering 2 coats over a coat of priming to wall surface including cost of all material and labour with T&P etc. complete as per OPWD specification & direction of Engineer-in-charge - Ground Floor |
| 57 | First Floor |
| 58 | Second Floor |
| 59 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures , labour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge.(MAYUR/CENTURY/DUROPLY) |
| 60 | 20mm thick grading plaster in cm (1:4) finished smooth to roof top including cost, conveyance, taxes, royalties, labour with T&P etc. complete in all respect as per the direction of Engineer-in-Charge Ground Floor |
| 61 | First Floor |
| 62 | Second Floor |
| 63 | Supplying,fitting, and fixing of P.V.C. Rain water pipe 110mm dia cost all labour, materials and T&P etc., completein all respect as per the direction of Engineer-in-Charge |
| 64 | Cement concrete of proportion (1:2:4) in F&F using 12mm size CBHG chips of approved quality including cost, conveyance, taxes & royalty of all materials and labour with T&P etc. complete in all respect. Ground Floor |
| 65 | EI works : Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire Polycab/Finolex/L&T/Anchor/Havells/V-Guard) Group-A -L.P- 100 F.P- 48 C.B.P- |
| 66 | Group-B L.P- 82 F.P- 32 C.B.P- |
| 67 | Group-C L.P- 66 F.P- 20 C.B.P- |
| 68 | Supply and fixing of 6Amp socket with 6Amp switch on existing board (Modular type ) |
| 69 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6Amp socket and 6Amp Modular switches (2x5A/15 S-S)connection (make-Havells/ Anchor/ Legrand /Roma/panasonic) |
| 70 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Polycab/Finolex/L&T/Anchor/Havells/V-Guard/) 2 X 1.5sq.mm +1 X 1.5sqmm |
| 71 | 2 X 2.5sq.mm +1 X 1.5sqmm |
| 72 | 2 X 4sq.mm +1 X 1.5sqmm. |
| 73 | 2 X 6sq.mm +1 X 2.5sqmm. |
| 74 | 4X 10sq.mm + 2 X 4sqmm. |
| 75 | Supply and drawing of following size PVC insulated single core multistrand copper conductor in existing surface/recessed/ steel /pvc conduit as required. 2 X 1.5sqmm |
| 76 | Supply and fixing of copper plate earthing( 600 X 600 X 3.15mm )with running copper flat 25 X 5mm from copper plate to funnel of 40mm dia G.I pipe including all accessories |
| 77 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required. |
| 78 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required |
| 79 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-Hager/Havells/Legrand/Anchor/schnider 12way, Double door |
| 80 | 16way Double door |
| 81 | Supply and fixing of 5Amp to 32A rating 240V \\"B\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required. (make-Hager/Havells/Legrand/Anchor/schnider single poles MCB LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Single pole (SP) |
| 82 | Single pole and Neutral (SP&N) |
| 83 | S/F of 32Amp DP MCB make-Hager/Havells/Legrand/Anchor/schnider |
| 84 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years. |
| 85 | 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 86 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 8 way TPN Distribution Boards For PDB/LDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40A FP RCCB (10KA),30mA Outgoings-32A SP MCB 10KA-24Nos.(Make-Havells/ Hager/ Schneider/Legrand/L&T) |
| 87 | Supply and fixing of 9Watt LED lamp , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Philips/ Havells/ AnchorBajaj) |
| 88 | Supply and fixing of 10 Watt LED BH Fitting ( Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 89 | Supply and fixing of 10 watt Mirrior light with all connections. , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k(Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 90 | S/F of 20W 4' LED fitting Surface LED Light fitting , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton |
| 91 | S/F of 18Watt White Circular/Square Surface LED fitting , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 92 | S/F of 90W LED street light fitting including all accessories , Lumens Efficacy minimum rating should meet :105 lumen per watt 6500k (Make-Havels/Panasonic/ Philips/Bajaj/Crompton) |
| 93 | S/F of G.I. Street light Bracket with M.S. Clamp |
| 94 | S/F of 1200mm Brush Less Direct Current BLDC Ceiling fan with Low wattage consumption fan , Heavy Duty,durable, copper winding,Aluminium blade(ISI mark)Crompton Grave/Khaitan/Havells/Orient/Polycab/V-Guard |
| 95 | Exhaust fan 300mm |
| 96 | Exhaust fan 450mm |
| 97 | Supply of PVC/XLPE Aluminium armored cables ISI marked.(Make- GLOSTER/Havells/Anchor. 95sqmm 3 1/2 core |
| 98 | Cable laying on wall surface with steel shaddle 25sqmm to 120sqmm |
| 99 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. 3.5C x 95 sq.mm |
| 100 | LT Indoor Panel S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 5 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD shall be installed in the incomer. Separate Aluminium Earth bus bar should be installed.01 number of 200 Amps 4P MCCB 16KA ( Make-LEGRAND/ Siemens/ Schneider).Busbar- 04 numbers of 200Amps 50kA Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 63A 4P MCCB 04 NOS FOR POWER BDB,40 Amp. 4P MCB 10 KA ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) onload type Changeover-01 number of 200 Amps 4P ( Make-LEGRAND/ Siemens/ Schneider) Out going- (ii) 05 nos 40A 4P MCB FOR LIGHT BDB ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) Instrument- (i) 3 numbers phase indicating lamp with 2A SP MCB,C,10KA.(ii) 01 set of MFM with RS-485 & CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) providing with Floor Rubber mat 3'X2'X6 mm |
| 101 | S/F of Metal Clad Industrial Type Plug, Socket, Interlocked Switch Socket Unit & Distribution Board. Industrial Socket with 20Amp SP MCB for AC point. make- Havells/ polycab/legrand/schneide |
| 102 | GPH works : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge (Supreme/Ashirvad/Oriplast) 20mm dia C-PVC Pipes In ground floor |
| 103 | 25mm dia C-PVC Pipes |
| 104 | In First Floor 20mm dia C-PVC Pipes |
| 105 | 25mm dia C-PVC Pipes |
| 106 | In Second Floor - 20mm dia C-PVC Pipes |
| 107 | 25mm dia C-PVC Pipes |
| 108 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.(Supreme/Ashirvad/Oriplast) In Ground floor32mm dia PVC ASTM-D(Sch-80) Pipes |
| 109 | In first floor 32mm dia PVC ASTM-D(Sch-80) Pipes In first floor |
| 110 | In second floor 40mm dia PVC ASTM-D(Such-80) Pipes in Gf |
| 111 | Third floor 50mm dia PVC ASTM-D(Sch-80) Pipes in Gf |
| 112 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall In Ground floor |
| 113 | 250mm thick wall In First floor |
| 114 | 250mm thick wall In Second floor |
| 115 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In Ground floor |
| 116 | In First floor |
| 117 | In second floor |
| 118 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. (Jaquar/Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany/Prayag/ equivalent make)15mm dia CP two way bib cock |
| 119 | 15 mm dia CP L.B. Bib cock |
| 120 | 15mm dia CP angle stop cock |
| 121 | 20mm dia CP Con. stop cock |
| 122 | 15mm dia CP flange |
| 123 | 15mm Cp extention piece |
| 124 | 32mm dia C-PVC ball valve.(Ashrivad make) |
| 125 | 40mm dia C-PVC ball valve.(Ashrivad make) |
| 126 | 50mm dia C-PVC ball valve.(Ashrivad make) |
| 127 | 125mmdia C.P.grating |
| 128 | 15mm dia CP revolving shower with arm ( Plaza make ) |
| 129 | 15mm dia C.P hand shower |
| 130 | 25mmx600mm long CP towel rail |
| 131 | CP soap holder |
| 132 | 15 mm dia CP Pillar Cock (Plaza/Amber/Aquatic Make) |
| 133 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge.10 litres capacity pvc low level cistern (Slimline-white) |
| 134 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 3.18m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.2000litre capacity water storage tanks including staging (3rd Floor) |
| 135 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge.110mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 136 | 110mm U-PVC door Tee |
| 137 | 110mm U-PVC Y Tee |
| 138 | 110mm U-PVC door bend |
| 139 | 110mm U-PVC plain bend |
| 140 | 110mm dia U-PVC off set |
| 141 | 110mm dia U-PVC 'P' trap |
| 142 | 110mm dia U-PVC cowl |
| 143 | 110mm dia U-PVC clamp |
| 144 | 110mm dia U-PVC pass over single socket |
| 145 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI/PVC SWR pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge.250mm to 375mm thick wall |
| 146 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.E.W.C. with S trap plain with seat cover(Parryware/Hind ware/Cera/Kerovit/Somany) |
| 147 | Supplying all materials, labour, T&P and fixing bowl pattern urinal of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.Half stall urinal (Jaquar)URS-WHT-13261 |
| 148 | 15mm CP spreader |
| 149 | 32mm CP doom waste |
| 150 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps(Plaza make) capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge.550x400mm Wash hand basin with Porcelain pedestal |
| 151 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeBig Size Mirror |
| 152 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 153 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 154 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In Ground floor |
| 155 | In first floor |
| 156 | IN second floor |
| 157 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.Same as Floor tile area In 1st Floor: |
| 158 | IN second floor |
| 159 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.12mm thick CP (1:4) on bw- In gf |
| 160 | 12mm thick CP (1:4) on bw- In first floor |
| 161 | 12mm thick CP (1:4) on bw- In Second floor |
| 162 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc. complete as per direction of the Engineer in charge. (Ceramic floor tiles of premium grade Kajaria / Somany make of size 30cm x 30cm to be pre-approved by the Engineer in charge) |
| 163 | In First floor |
| 164 | In 2nd Floor |
| 165 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles etc.complete as per direction of the Engineer in charge. (Ceramic wall tiles of premium grade Kajaria / Somany make size 45 x 30 special plain / printed series to be pre-approved by the Engineer in charge)In ground floor (inside/outside) |
| 166 | In First floor |
| 167 | In 2nd Floor |
| 168 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 169 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 170 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00 mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 171 | Providing and fixing of Partly fixed,partly top hung and partly louvered windows of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick D quality,galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Section for internal top and bottom frames in the louvered areas should be 18 x 40 mm.Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturers supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating.The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete. |
| 172 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Inside size 760mmx760mmx460mm |
| 173 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Inside size 910mmx910mmx910mm |
| 174 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Brick masonry soakway pit 1.20m dia x 2.00m deep |
| 175 | Brick masonry soakway pit 1.80m diax2.60m deep |
| 176 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia u-pvc pipe alround concrete |
| 177 | 160mm dia u-pvc pipe alround concrete |
| 178 | Construction of 100 users RCC septic tank- (I/S size-5.70mx2.10mx2.40m)-30cm wide wallEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 179 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 180 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 181 | Supplying all materials, labour, T&P and providing dewatering water from pit using 5 HP disel pump set etc.all complete as per specification and direction of the Engineer in charge |
| 182 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 183 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 184 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to 4.30m height |
| 185 | R.C.C beams, columns, girder and bressmer etc--In G.F |
| 186 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 187 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 188 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn foundation and plinth |
| 189 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 190 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn Ground floor |
| 191 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 192 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 193 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.Making MS step iron in 20mm diameter MS steel bars |
| 194 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee |
| 195 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 196 | Sinking of 200mm x 150mm size Tube well through D.T.H or Combination drilling rigs in hard rock areas with GI/PVC casing pipes(2Nos)Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of 200 mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/PVC casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tube well).Labour for drilling of 200 mm dia bore 00 mtr to 125 mtrs |
| 197 | 150mm dia |
| 198 | Lowering the following size G.I/ PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and supplying and fixing all jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above.Labour for lowering of 200mm dia casing pipe in bore 00 mtr to 45 mtrs |
| 199 | Cost of 200 mm dia casing Pipe |
| 200 | Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge. |
| 201 | Supplying all materials, labour, tools and plant and withdrawing casing pipes from the unsuccessful bore and depositing in the departmental store in good condition. |
| 202 | Supplying all materials and labour, tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied by the Department) |
| 203 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submerisble electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge1.50H.P single phase submersible pump set (KP4-03215 pumpset CP)Kirloskar/Crompton/CRRI make |
| 204 | DOL Control panel |
| 205 | 32mm dia steel short piece |
| 206 | Well cap |
| 207 | 50mm size CI bracket |
| 208 | 2.50 sqmm flat cable |
| 209 | Steel rope with cover |
| 210 | 20mm dia rigid UPVC pipes |
| 211 | Labour charges for lowering including transportation |
| 212 | 32mm dia HDPE pipe |
| 213 | Supplying all materials, labour, T&P and providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge. |
| 214 | Supplying all materials, labour, T & P and constructing Bore well protection chamber of the inside size 650x650x1000 hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g. chips, 12mm thick cement plaster (1:4) inside and outside, RCC cover slab in (1:1.5:3) using 12 mm size h.g. chips, earthwork in excavation in all kind of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction pof the engineer in charge. |
| 215 | 30000 Ltrs.Under ground sump. Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 216 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 217 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site. |
| 218 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per direction of the Engineer in charge. |
| 219 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 220 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.RCC floor, roof slab, chajja upto in ground floor |
| 221 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.In ground floor |
| 222 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 223 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:3) including watering,curring and conveyance of all materials to site. |
| 224 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender