Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #58361860

Tender For special Repair To Drain At Restricted And Unrestricted Area Of Cod Under Ge (East) Jabalpur

Issued by Statutory Bodies & Commissions/Committees · Jabalpur, Madhya Pradesh
Tender Value
28.98 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
4 days left
EMD
57970
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Drain At Restricted And Unrestricted Area Of Cod Under Ge (East) Jabalpur

BOQ

Name of Work:- SPL REPAIR TO DRAIN AT RESTRICTED AND UNRESTRICTED AREA OF COD UNDER GE (EAST) JABALPUR
Sl. No. Item Description
1UNRESTRICTED AREA
2Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed.
3Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
4Demolition of Cement concrete (Unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
5Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr depth for foudations etc or for column footings, manholes etc not exceeding 10 Sqm on plan and not exc 1.5 mtr in depth and getting out in soft / loose soil etc complete all as specified and as directed
6Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in soils complete all as specified and as directed.
7Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level n. exc. 1.5 m above starting point as in soils complete all as specified and as directed.
8Material and Labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, mass concrete etc complete all as specified and as directed.
9M&L for Reinforced cement concrete M-25 (design mix) grade using 20 mm graded stone aggregate as in foundations, including rafts, footings foundation beams, plinthbeams ,bases for columns etc basement slabs and mass concrete complete all as specified and as directed.
10M&L for Reinforced cement concrete M-25 (design mix) grade using 20 mm graded stone aggregate as in Walls, retaining walls, basement walls, blast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses and mass concrete complete all as specified and directed.
11Use and waste of formwork to side of concrete foundation, footings bases of columns, sides and soffits of plinth beams for rough finished flat surfaces complete all as specified and as directed.
12Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batterfor rough finished flat surfaces complete all as specified and as directed.
13Material and Labour for TMT bars 10mm dia and over dia cut to length, bent to shape required, including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 9mm dia or securing with clips complete all as specified and as directed.
14Removing building materials etc. (other than soil) to a distance of 100m, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed.
15Supplying and fixing of PVC (SWR) single socketed 110 mm bore of pipes as in weep holes of compound wall complete all as specified and as directed
16M&L for precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for cover slabs of manholes, cover slab set in CM 1:4 side portion only with plain surfaces including necessary form work (reinforcement to be measured and paid separately) complete all as specified and as directed by Engr-in-Charge
17M & L for broken stone/broken or boulders of Loose filling with aggregates of gauge 80 to 150 mm as in side of drain complete all as specified and as directed
18M&L for Hardcore of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and as directed
19M&L for Moorum/red bajri filling, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering as required complete all as specified and directed.Note:consolidated thickness shall be measured.
20M&L for brick work with Burnt brick built in cement mortar (1:4), curved on plan exceeding 6m mean radius complete all as specified and directed.
21M&L for PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in coping complete all as specified and directed.
22M&L for 10 mm thick cement plaster in CM 1:4 on walls of brick surface or concrete including finished surfaces shall be even and smooth without using extra cement complete all as specified and directed..
23M&L for 15 mm thick cement plaster in CM 1:4 on walls brick surface or concrete including finished surfaces shall be even and smooth without using extra cement complete all as specified.
24Dismantling of reinforced concrete drain pipes of 450 mm dia , jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed.
25M&L for concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement concrete 1:3:6 type C-2 around 450mm dia complete all as specified and directed.
26M&L for 450mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed.
27Dismantling of reinforced concrete drain pipes of 300 mm dia, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed.
28M&L for concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement concrete 1:3:6 type C-2 around 300mm dia complete all as specified and directed.
29M&L for 300mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
30M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.50m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates etc and the like including weathering slightly rounded/ chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
31RESTRICTED AREA
32Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed.
33Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
34Demolition of Cement concrete (Unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
35Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr depth for foudations etc or for column footings, manholes etc not exceeding 10 Sqm on plan and not exc 1.5 mtr in depth and getting out in soft / loose soil etc complete all as specified and as directed
36Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in soils complete all as specified and as directed.
37Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level n. exc. 1.5 m above starting point as in soils complete all as specified and as directed.
38Material and Labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, mass concrete etc complete all as specified and as directed.
39M&L for Reinforced cement concrete M-25 (design mix) grade using 20 mm graded stone aggregate as in foundations, including rafts, footings foundation beams, plinthbeams ,bases for columns etc basement slabs and mass concrete complete all as specified and as directed.
40M&L for Reinforced cement concrete M-25 (design mix) grade using 20 mm graded stone aggregate as in Walls, retaining walls, basement walls, blast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses and mass concrete complete all as specified and directed.
41Use and waste of formwork to side of concrete foundation, footings bases of columns, sides and soffits of plinth beams for rough finished flat surfaces complete all as specified and as directed.
42Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batterfor rough finished flat surfaces complete all as specified and as directed.
43Material and Labour for TMT bars 10mm dia and over dia cut to length, bent to shape required, including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 9mm dia or securing with clips complete all as specified and as directed.
44Removing building materials etc. (other than soil) to a distance of 100m, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed.
45Supplying and fixing of PVC (SWR) single socketed 110 mm bore of pipes as in weep holes of compound wall complete all as specified and as directed
46M&L for precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for cover slabs of manholes, cover slab set in CM 1:4 side portion only with plain surfaces including necessary form work (reinforcement to be measured and paid separately) complete all as specified and as directed by Engr-in-Charge
47M & L for broken stone/broken or boulders of Loose filling with aggregates of gauge 80 to 150 mm as in side of drain complete all as specified and as directed
48M&L for Hardcore of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and as directed
49M&L for Moorum/red bajri filling, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering as required complete all as specified and directed.Note:consolidated thickness shall be measured.
50M&L for brick work with Burnt brick built in cement mortar (1:4), curved on plan exceeding 6m mean radius complete all as specified and directed.
51M&L for PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in coping complete all as specified and directed.
52M&L for 10 mm thick cement plaster in CM 1:4 on walls of brick surface or concrete including finished surfaces shall be even and smooth without using extra cement complete all as specified and directed..
53M&L for 15 mm thick cement plaster in CM 1:4 on walls brick surface or concrete including finished surfaces shall be even and smooth without using extra cement complete all as specified.
54Dismantling of reinforced concrete drain pipes of 450 mm dia , jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed.
55M&L for concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement concrete 1:3:6 type C-2 around 450mm dia complete all as specified and directed.
56M&L for 450mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed.
57Dismantling of reinforced concrete drain pipes of 300 mm dia, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed.
58M&L for concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement concrete 1:3:6 type C-2 around 300mm dia complete all as specified and directed.
59M&L for 300mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
60M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.50m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates etc and the like including weathering slightly rounded/ chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
61Schedule of credit amount of Rs 56,537.50 to be deducted during AOC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58361860
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 28.98 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Drain At Restricted And Unrestricted Area Of Cod Under Ge (East) Jabalpur
Basic Detail
Tender No 8936/E8
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 04 Nov 2026
Submission Date 25 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 28.98 Lakhs
Tender Fee 500
EMD 57970
Exemption Available
Document List
BOQ_893996.xls
e884bd10-6efd-4c0e-aba7-2e3ebbb627f1.html
TENDER936.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_893996.xls

html

e884bd10-6efd-4c0e-aba7-2e3ebbb627f1.html

pdf

TENDER936.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender