Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #58361842

Tender For Provn Of 02 X Drainage Link With Civ Drainage (Cook House To Rp Gate Approx 350 Mtrs And Rp Gate To Offr Mess 150 Mtrs At Adhoc Transit Camp Sadilapur, Provn Of Medicine Storage Room And Provn Of Hard Standing Alongwith Connected Pathway A

Issued by Statutory Bodies & Commissions/Committees · Kamrup Metro, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Nov 2026
2 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 02 X Drainage Link With Civ Drainage (Cook House To Rp Gate Approx 350 Mtrs And Rp Gate To Offr Mess 150 Mtrs At Adhoc Transit Camp Sadilapur, Provn Of Medicine Storage Room And Provn Of Hard Standing Alongwith Connected Pathway At 151 Bh Under Ge Guwahati

BOQ

Name of Work:- PROVN OF 02 X DRAINAGE LINK WITH CIV DRAINAGE (COOK HOUSE TO RP GATE APPROX 350 MTRS AND RP GATE TO OFFR MESS 150 MTRS AT ADHOC TRANSIT CAMP SADILAPUR, PROVN OF MEDICINE STORAGE ROOM AND PROVN OF HARD STANDING ALONGWITH CONNECTED PATHWAY AT 151 BH UNDER GE GUWAHATI
Sl. No. Item Description
1B/R PORTION
2Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc not exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
3Returning filling in, including spreading. Levelling, watering and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and as directed.
4Removing excavated material (soil) to a distance not exc. 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
5M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6.00 m mean radius built in CM 1:6 complete as specified and directed.
6M&L for Brickwork with subclass ‘B’ bricks straight or curved on plan to any radius in half brick wall, built in CM 1:4 complete all as specified and as directed.
7M&L for rendering 15mm thick plaster on fair faces of brick or concrete surfaces in CM (1:4) mixed with WPC finished the surface even and smooth without using extra cement complete all as specified and directed. (Note- supply only WPC shall be measured and paid seperately).
8Supply only liquid water proofing compound
9M&L for broken stone or boulders hard core of gauge n.exc. 63 mm, deposited, spread and leveled in layers n.exc 15 cm thick, watered and well rammed to a true surface in plinth protection, hard standing, floor etc complete all as specified and directed.
10M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete after demolition of existing concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
11M&L for plain cement concrete (1:2:4) type B0) (using 12.5 mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
12M&L for providing precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in cover slab set in cement mortar (1:4) complete all as specified and directed.Note: Reinforcement shall be measured and paid seperately under respective item of schedule.
13M&L for TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
14Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed. Note :- Measurment shall be taken only for inner girth.
15M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in sub base of floors and path, finished the surface fair and even complete all as specified and as directed.
16M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed.
17M&L for RCC 1:2:4, type B1 (nominal mix) using 20 mm graded stone aggregate as in foundation rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concrete filling and mass concrete complete all as specified and directed. Note:- Reinfocements will be measured and paid seperately under appropiate item
18M&L for RCC 1:2:,) type B1 (nominal mix) using 20mm graded granite stone aggregate in columns, pillars, piers, posts, struts and the like complete, all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately.
19M&L for RCC 1:2:4, type B1 (nominal mix) using 20mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. Note:- Reinfocements will be measured and paid seperately under appropiate item
20Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, Rough finished surfaces of concrete flat complete all as specified and as directed
21Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished surfaces of concrete square, rectangular or polygonal complete all as specified and as directed.
22Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces of concrete flat complete all as specified and as directed
23M&L for Brickwork with subclass ‘B’ bricks old size, straight or curved on plan not exceeding 6m mean radius, built in CM 1:4 complete all as specified and as directed.
24M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
25M&L for TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia, complete, all as specified and directed.
26M&L for Sand filling under floor n.exe 25cm thick in layers spreading, levelling and well rammed in layer or in foundation including watering and consolidation as required complete all as specified and as directed.
27M&L for rendering 15mm thick plaster in two layers (10mm+5mm) on brick or concrete surfaces in CM (1:4) mixed with WPC on second layer finished the surface even and smooth without using extra cement complete all as specified and directed. (Note- supply only WPC shall be measured and paid seperately).
28M&L for rendering 10mm thick on other than fair surfaces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth w/o using extra cement complete all as specified and as directed.
29M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of 1.5mm thick wall care putty including primer complete all as specified and directed.
30M&L preparation of new surfaces of wall and applying two coats of weather exterior acrylic emulsion paint over a coat of 1.5mm thick wall care putty including priming coat of exterior primer complete all as specified and directed.
31S&F Mild steel framed work such as grills, gratings etc.with ends of bars shouldered and/or riveted,or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and as directed.
32S&F Prepainted galvalume aluminium zink coating GI based corrugated/ semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed.
33S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as iridges, hips, valley cutters, eave board etc fixed with self tapping screws complete all as specified and as directed..
34S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde- E- 250) complete all as specified and directed.
35M&L Rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary or counter sunk) forming holes, with riveted, bolted or welded attachment etc, conforming to Fe-290 Gde E-165 compete as specified and directed
36S&F Mild steel screw bolts (machine made) with hexagonal heads at one end and screws other end to be fitted with washes and one hexagonal nut, exc 5cm and n.exc 10cm long and dia of neck 11 to 15 mm as specified and directed.
37M&L for preparation of new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete as specified and directed.
38Taking down chowkats or frame not exc 1.5 sqm with shutter (with out taking off shutter from frame) all as specified and remooving from site complete all as specified and as directed.
39Taking down chowkats or frame exe 1.5sqm and n.exe 4 sqm with shutter (with out taking off shutter from frame) all as specified and remooving from site complete all as specified and as directed.
40Supply and fixing of 1.25 mm thick pressed steel door frames of size 125 mm x 60 mm with one or more rebated including necessary fixing lugs, hinges, lock strike plate, etc including filling PCC M-15 (1:2:4) in hollow portion etc complete all as specified and as directed.
41S&F 30mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commerical type on both sides complete all as specified and directed.
42S&F 35 mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles, prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 clause 8.24(a) and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.(Note :- S & F Glass/gauge shall be measured and paid for separately)
43S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
44S&F 150 mm long Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed.
45S&F 300 mm aluminium alloy sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy fixed complete all as specified and as directed.
46S&F 100 mm size Butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed.
47S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
48S&F mild steel 300mm, ordinary rat tail rod pattern spring including roller and roller plate complete all as directed.
49M&L for preparing new wooden surfaces of any description, not otherwise describe over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
50M&L for providing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and as the directed.Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paid seperately at supply only rates. (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
51M&L for 4 mm thick frosted sheet glass ordinary quality and glazing with oil putty/wooden beads in squares not exc. 0.5 Sqm in each pane complete all specified and as directed.
52Supply and fixing anodized aluminium snap grid frame work for false ceiling, size of grid 605mm x 605mm complete all as specified & as directed.
53M & L for 4 mm thick, Non asbestos fibre cement building boards fixed in ceiling or laid/ inserted to timber/GI/Aluminium frame work with screws, etc complete as specified and as directed.
54M&L for Virified Ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15 mm thick CM (1:6) complete all as specified and as directed.
55Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loosed soil complete all as specified and as directed.
56M&L for 100 mm thick PCC (1:4:8) type D-2 using 40mm graded aggregate as in sub base finishing the surface smooth and fair complete all as specified and directed
57M&L for PCC M-10 grade (nominal mix) using 40mm graded stone aggregate as in side of path, finish even and smooth without using extra cement complete all as specified and as directed.
58M&L for 55 mm thick PCC type B-1, 1:2:4 (20mm graded aggregate) using 20mm graded aggregate as in flooring in hardstanding complete all as specified and as directed.
59M&L for cement concrete (1:3:6) type C1 using 20mm graded stone aggregate in coping cement complete all as specified and directed.
60M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry with gery cement and pigment including 15mm thick screed bed in cement sand mortar (1:6) complete all as specified and as directed.
61E/M PORTION
62M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper PVC insulated and unsheathed FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit, medium grade minimum 20 mm dia ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof and chiselling on wall complete and making good the disturbed surfaces of wall / ceiling by cement mortar 1:4 including painting to existing surfaces etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick Modular top cover for mounting of modular fittings, switches, sockets outlets, regulators etc and provisioning of 1.5 sqmm PVC insulated unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :-
63(a) One light/ ceiling fan/ exhaust fan point controlled by one, one way switch.
64(b) One 3/5 pin socket outlet, 5/6 Amp point on same board with other switches.
65(c) One 3/5 pin socket outlet, 5/6 Amp on independent board with cable of 1.5 sqmm size & other switches.
66All as per item No. 61.00 above but wiring with 4sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15/16 Amps switch socket combination on independent board.
67M&L for sub main wiring concealed with two run of single core 4 Sqmm (FRLSH) PVC insulated and unsheathed cable with copper conductor (multi stranded) 1100 volts grade, ISI marked drawing in and including PVC rigid non metalic PVC concealed and conduit of adequate size with proper colour coding and making electric connections & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including one run 4 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and as directed. NOTE: (i) Quoted shall deemed to be included for cutting and chasing for conduits and sinking for boxes, making holes in wall/floor for passing through conduit and making good to wall/concrete/floor etc (ii) 2 runs of main wire, 1 run of earth wire, 1 run of PVC Conduit with accessories shall be measured as one length.
68Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
69Supply and fixing LED Tubelight lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Please Enable Macros to View BoQ information
70Supply and fixing LED Tubelight lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58361842
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 24-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 02 X Drainage Link With Civ Drainage (Cook House To Rp Gate Approx 350 Mtrs And Rp Gate To Offr Mess 150 Mtrs At Adhoc Transit Camp Sadilapur, Provn Of Medicine Storage Room And Provn Of Hard Standing Alongwith Connected Pathway At 151 Bh Under Ge Guwahati
Basic Detail
Tender No 8703/E8
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 03 Nov 2026
Submission Date 24 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 56000
Exemption Available
Document List
8703Tender.pdf
bd34a520-ed7c-48a8-aa94-2e2a199aceb3.html
BOQ_894124.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

8703Tender.pdf

html

bd34a520-ed7c-48a8-aa94-2e2a199aceb3.html

xls

BOQ_894124.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender