Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #58361837

Tender For Provision Of Pipe Line For Interlink Of Nausena Bagh Booster Pump House To Nausena Bagh Dolphin Hill And Old Nausena Bagh Over Head Tank Under Ge (Utility-Ii) Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
44.30 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
5 days left
EMD
88600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Pipe Line For Interlink Of Nausena Bagh Booster Pump House To Nausena Bagh Dolphin Hill And Old Nausena Bagh Over Head Tank Under Ge (Utility-Ii) Visakhapatnam

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Nov-2026 Corrigendum_1 BOQ 24-Nov-2026

BOQ

Name of Work:- PROVISION OF PIPE LINE FOR INTERLINK OF NAUSENA BAGH BOOSTER PUMP HOUSE TO NAUSENA BAGH DOLPHIN HILL AND OLD NAUSENA BAGH OVER HEAD TANK UNDER GE (UTILITY-II) VISAKHAPATNAM
Sl. No. Item Description
1Earthwork excavation in trenches soft/ loose soil not exceeding 1.5 m in width and not exceeding 1.5 m in depth, in all types of soil, for laying pipelines, including dressing of sides, ramming of bottoms, and getting out the excavated material, complete all as specified and directed by the Engineer-in-Charge. Note:- The work shall include necessary shoring, strutting, dewatering if required.
2Returning, filling and compacting excavated earth in trenches, including spreading, leveling, watering, and well ramming in layers not exceeding 25 cm thickness, complete all as specified and directed by the Engineer-in-Charge.
3Removing excavated material to a distance not exceeding 50 m, in soft/ loose soil including loading, unloading, and depositing the same at a location as directed, at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by the Engineer-in-Charge.
4Material and Labour for Plain Cement Concrete (PCC) of mix 1:2:4 (Type B1) using 20 mm nominal size graded crushed stone aggregate, for thrust blocks, anchor blocks, and pipe supports, and other mics work including necessary excavation, centering and shuttering / formwork, mixing, placing in position, compacting by mechanical vibrator, finishing to required line, level and shape, and curing, complete all as specified and directed by the Engineer-in-Charge.
5Cutting of existing 300/250 mm diameter CI/DI/MS pipelines in position for insertion of tees, branches, valves, or other fittings, including necessary precautions to avoid damage to the existing pipeline including making proper cuts, edge preparation, alignment for jointing, and all incidental works required for facilitating insertion of new fittings, complete all as specified and directed by the Engineer-in-Charge.
6Supply, laying, jointing, testing and commissioning of 250 mm diameter, Class K-9 Ductile Iron (DI) pipe conforming to IS: 8329:2000, centrifugally cast (spun) pressure pipe with socket and spigot ends, suitable for push-on joints, including supply and fixing of rubber gaskets/jointing materials. The pipes shall be provided with external zinc coating with a finishing layer of bitumen, and internal cement mortar lining with bituminous seal coat, complete in all respects, including handling, loading, unloading, laying, alignment, jointing, testing, and commissioning, complete all as specified and directed by the Engineer-in-Charge.
7Supply, laying, jointing, testing and commissioning of M.S. ERW pipes conforming to IS: 3589, Grade 330, of 250 mm nominal bore and 6.0 mm wall thickness, including all necessary fittings such as bends, tees, reducers, flanges, etc., as required. The work shall include cutting, edge preparation, welding, jointing, and fixing in position as per site requirements. The pipes shall be painted with one coat of red oxide primer followed by two coats of approved synthetic enamel paint of specified colour. Complete in all respects, including handling, loading, unloading, alignment, jointing, testing, and commissioning, complete all as specified and directed by the Engineer-in-Charge.
8Supply, laying, jointing, testing and commissioning of M.S. ERW pipes conforming to IS: 3589, Grade 330, of 200 mm nominal bore and 6.0 mm wall thickness, including all necessary fittings such as bends, tees, reducers, flanges, etc., as required. The work shall include cutting, edge preparation, welding, jointing, and fixing in position as per site requirements. The pipes shall be painted with one coat of red oxide primer followed by two coats of approved synthetic enamel paint of specified colour. Complete in all respects, including handling, loading, unloading, alignment, jointing, testing, and commissioning, complete all as specified and directed by the Engineer-in-Charge.
9Supply, laying, jointing, testing and commissioning of M.S. ERW pipes conforming to IS: 3589, Grade 330, of 150 mm nominal bore and 6.0 mm wall thickness, including all necessary fittings such as bends, tees, reducers, flanges, etc., as required. The work shall include cutting, edge preparation, welding, jointing, and fixing in position as per site requirements. The pipes shall be painted with one coat of red oxide primer followed by two coats of approved synthetic enamel paint of specified colour. Complete in all respects, including handling, loading, unloading, alignment, jointing, testing, and commissioning, complete all as specified and directed by the Engineer-in-Charge.
10Supply, laying, jointing, testing and commissioning of M.S. ERW pipes conforming to IS: 3589, Grade 330, of 100 mm nominal bore and 6.0 mm wall thickness, including all necessary fittings such as bends, tees, reducers, flanges, etc., as required. The work shall include cutting, edge preparation, welding, jointing, and fixing in position as per site requirements. The pipes shall be painted with one coat of red oxide primer followed by two coats of approved synthetic enamel paint of specified colour. Complete in all respects, including handling, loading, unloading, alignment, jointing, testing, and commissioning, complete all as specified and directed by the Engineer-in-Charge.
11Material and Labour for CI / DI fittings suitable for CI / DI spigot and socketed pipe of size 100mm to 300mm bore and any type such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces (single branch, \\"Y\\" junction, double branch, cross etc), collars, caps and plugs etc, complete all as specified and directed by Engineer-in-Charge.
12Supply and fix CI sluice valves, of size 250 mm dia, PN 1.6, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints nuts, bolts washers and rubber gasket etc, complete all as specified and directed by the Engineer-in-Charge.
13Supply and fix CI sluice valves, of size 200 mm dia, PN 1.6, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints nuts, bolts washers and rubber gasket etc. complete all as specified and directed.
14Supply and fix CI sluice valves, of size 150 mm dia, PN 1.6, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints nuts, bolts washers and rubber gasket etc, complete all as specified and directed by the Engineer-in-Charge.
15Supply and fix in repair CI non return valve of 200mm dia sizes with by pass arrangement and necessary rubber gasket, nuts, bolts, and washers etc, complete all as specified and directed by the Engineer-in-Charge.
16Supply and fix in replacement of CI foot valve ball type of 200 mm dia heavy duty with necessary rubber gasket, bolts, nuts and washers, complete all as specified and directed by the Engineer-in-Charge.
17Supply and lay GI water tubing galvanised medium grade in floors/ on roof /on wall / trenches including all fittings of 25 mm dia, complete all as specified and directed by the Engineer-in-Charge.
18Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe of 25 mm bore including all fittings etc, complete all as specified and directed by the Engineer-in-Charge.
19Supply and fix Pressure gauge 4\\" dial 0-21 kg/cm2 rating with ball valve including making necessary hole in MS pipe and fittings, complete all as specified and directed by the Engineer-in-Charge.
20M&L for construction of valve pit of internal size 1200 cm x 1200 cm x 100 cm with one brick thick brick masonary wall in cement mortar (1:4) PCC foundation 15 cm thick (1:4:8) type D-2 with 15 cm offsets, PCC copping 5 cm thick (1:2:4) type B-1, plastering 15 mm thick in cement mortar (1:4), 40x40x6mm angle iron frame and 3mm thick MS sheet cover with locking arrangement including painting to steel surfaces wtih two coats of synthetic arrangement including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation and earth work, complete all as specified and directed by the Engineer-in-Charge.
21Supply, installation, testing and commissioning of centrifugal type split casing, electrically driven pumping set having discharge capacity of 150 m3/hr against a total head of 50 metres, Bronze impeller, CI casing, stainless steel shaft complete with 50 HP squirrel-cage induction TEFC IE-2 NFLP motor, gland packing type sealing arrangement suitable for 415 volts, 3-phase, 50 Hz AC supply, including coupling, common MS base plate, foundation bolts, nuts and washers, alignment of pump and motor, grouting, vibration control arrangement, making all mechanical and electrical connections, complete with RCC foundation as per OEM recommendation shuttering if required, curing and finishing, complete with trial run, testing to full load conditions, and commissioning to the entire satisfaction, complete all as specified and directed by the Engineer-in-Charge.
22Supply and install in repair including testing and commissioning of LT panel indoor type totally enclosed with front and rear opening hinged doors and raised platform of suitable sizes weather dust vermin proof made out of 2.0 mm thick CRCA sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 250 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accomodate the following items including supply and fix following items :-(a) MCCB 160 Amps 4 pole 35 KA - adjustable type with extended terminal (incoming) -01 Nos(b) MCCB 125 Amps 4 pole 25 KA - adjustable type with extended terminal (incoming) - 02 Nos(c) Star delta fully sutomatic startere 50 HP with in built contactor and relay - 02 Nos(d) MCB TPN 40 Amps 4 pole 16 KA - 2 Nos(e) Multifunctional meter (KWH, Voltage,Ampere and frequency)-03 set(f) RYB indicator lamp-03 set
23Supply, laying in trenches or fixing on wall or passing through pipe or in cable ducts, XLPE insulated PVC screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of 3.5 core 70 sqmm size cable, complete all as specified and directed by the Engineer-in-Charge.
24M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip of size 32 x 6mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc, complete all as specified and directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58361837
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.30 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Pipe Line For Interlink Of Nausena Bagh Booster Pump House To Nausena Bagh Dolphin Hill And Old Nausena Bagh Over Head Tank Under Ge (Utility-Ii) Visakhapatnam
Basic Detail
Tender No 8221(A)
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 09 Nov 2026
Submission Date 24 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 44.30 Lakhs
Tender Fee 500
EMD 88600
Exemption Available
Document List
3d8a2843-e4ca-426c-8d26-534cf71ac671.html
8221_Tender.pdf
BOQ_894046.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

3d8a2843-e4ca-426c-8d26-534cf71ac671.html

pdf

8221_Tender.pdf

xls

BOQ_894046.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender