Tender For Repair And Maintenance Of Pumps, Motors, Starters, Control Panels, Relay, Capacitor Banks, Filtration Plants And Misc Items At Bhalra Mil Stn Under Age (I) Bhlara (Nit No. 84 Of 2026-27)
Tender Value
10 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
10 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagrota → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Pumps, Motors, Starters, Control Panels, Relay, Capacitor Banks, Filtration Plants And Misc Items At Bhalra Mil Stn Under Age (I) Bhlara (Nit No. 84 Of 2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for taking out Centrifugal Pump of capacity 40 HP, transportation of same from site to workshop and back, dismantling of cable / pipe connection and reinstallation of pump set after repair on the existing foundation and making electrical connections complete all as specified and directed. Note : All spares parts required will be measured and paid for separately |
| 2 | Supply only MS tyre coupling suitable size 40 HP Centrifugal pump set including making necessary machining work like, boring, key way and key etc., work required at site in the delivery pipe lines |
| 3 | Supply only suitable Ball Bearing Make : SKF |
| 4 | Supply only CI Bearing Housing |
| 5 | Supply only Water Seal 50mm x 68mm x 10mm |
| 6 | Supply only Packing Sheet |
| 7 | Supply only 'O' Ring Set |
| 8 | Supply only Pump Shaft SS AISI-410 |
| 9 | Supply only SS Nut Bolt & Washer of 10mm dia |
| 10 | Supply only Grease |
| 11 | Supply only Graphite Gland Dori |
| 12 | Material and labour for taking out Motor Set of capacity 40 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections complete all as specified and directed. Note : All spares parts required shall be measured and paid for separately |
| 13 | Material and labour for rewinding of damaged / burnt motor of capacity 40 HP any type by using enamelled copper wire of superior quality of existing grade and same Nos. of turns including varnishing ‘F’ class insulation and drying in heat chamber / Oven including all other material / fittings and testing on completion, complete all as specified and directed. |
| 14 | Ball Bearing for 40 HP capacity motor front side |
| 15 | Ball Bearing for 40 HP capacity motor back side |
| 16 | Mechanical Seal for 40 HP capacity motor |
| 17 | Rubber washer Kit for 40 HP capacity motor |
| 18 | Bush cover for 40 HP capacity motor |
| 19 | Packing sheet for 40 HP capacity motor |
| 20 | Circlips Clamp for 40 HP capacity motor |
| 21 | Material and labour for taking out Monoblock pump-Motor Set of capacity 10 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections complete all as specified and directed. Note : All spares parts required shall be measured and paid for separately |
| 22 | Ball Bearing for 10 HP capacity motor front side |
| 23 | Ball Bearing for 10 HP capacity motor back side |
| 24 | Mechanical Seal for 10 HP capacity motor |
| 25 | Rubber washer for 10 HP capacity motor |
| 26 | Bush cover for 10 HP capacity motor |
| 27 | Packing sheet for 10 HP capacity motor |
| 28 | Circlips Clamp for 10 HP capacity motor |
| 29 | PVC Motor cooling Fan of suitable size |
| 30 | Gun Metal impeller of suitable size |
| 31 | Material and Labour for disconnecting of 20/15 HP Submersible Pump Set motor kit from inside the Water Supply Sump from the delivery pipe for repair / rewinding, lifting, transportation to approved workshop for repair / rewinding with super enamalled copper winding wire of suitable size, insulation material i.e PVC copper cable lead, glass fibre sleeves, cotton tape, insulation paper, varnish and bearing grease etc., & reassembling of motor after rewinding and fixing the same at its original position with and including necessary nuts, bolts, washers etc., required at site of work, complete all as specified & directed. |
| 32 | Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 10 Sqmm 3 Core, complete all as specified and directed.Make : Havells / Finolex / Polycab / Plaza / Asian |
| 33 | Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 25 Sqmm 3 Core, complete all as specified and directed.Make : Havells / Finolex / Polycab / Plaza / Asian |
| 34 | S&F in Repair/replacement of Star Delta Starter fully automatic , Three Phase, 440 volts suitable for 40 HP motor having accessories such as contactor, relay,having overcurrent protection,single phase preventer,phase sequence controller complete including taking down old unserviceable Star Delta Starter all as specified and directed. Make : L&T,Legrand / Siemens / Havells / BCH. |
| 35 | S&F in replacement of fully automatic starter panel suitable for upto 20/15 HP capacity submerible pump,having overcurrent,single phase preventer,phase sequence controller complete including taking down old unserviceable Starter all as specified and as directed.Make : L&T / Havells / Legrand / ABB/Havells/BCH |
| 36 | S& F in repair thermal overload relay for starter panel having adjustable setting as under complete all as specified & directed |
| 37 | (a) 20 to 40 amp |
| 38 | (b) 45 to 75 Amp |
| 39 | S& F in repair 3 pole contactor 415 V for starter panel of following capacity as per sample |
| 40 | (a) 40 amp |
| 41 | (b) 70 amp |
| 42 | Cast Iron Butterfly Valve flanged type 100 mm bore with drilled flanged end heavy duty all as per IS : 4038 complete all as specified and as directed. |
| 43 | Cast Iron Butterfly Valve flanged type 80 mm bore with drilled flanged end heavy duty all as per IS : 4038 complete all as specified and as directed. |
| 44 | Supply and fixing in replacement air release valve of 50mm dia with double chamber of bore confirming to IS 14845 including taking out unserviceable air release valve complete all as specified and directed by Engineer-in-Charge of the following sizes:- Make : Advance / Bir / Leader / Sant/RAMCO |
| 45 | S&F MCCB, 4 pole 415V, adjustable type, 400 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) including taking down old unserviceable MCCB complete all as specified and as directed. |
| 46 | S&F MCCB 3 pole 415V, adjustable type, 100 Amps, breaking capacity 16 KA, FP, 415V (adjustable thermal and magnetic release) including taking down old unserviceable MCCB complete all as specified and as directed. |
| 47 | S&F in reapir ON LOAD Change Over Switch 415 volt in sheet metal enclosure Four Pole of capacity 200 Amps complete all as specified and directed |
| 48 | S&F in reapir ON LOAD Change Over Switch 415 volt in sheet metal enclosure Four Pole of capacity 400 Amps complete all as specified and directed |
| 49 | Testing of drinking water analysis report of physico-chemical and micro biological analyzing with following parameters :- (i) Temperature (ii) Ph value (iii) Taste (iv) Turbidity (v) Odour (vi)Total hardness CACO3 (vii) Colour (viii) Zinc (ix) Lead (x)Cyanide (xi) Chloride (xii) Fluoride (xiii)Ammonia (xiv) Nitrate (xv) TDS (xvi)Phenolic compound (xvii) Residue free chlorine Note :- (i) The sample will be obtained him self/rep of contractor in presence of JE E/M or Engr-in-charge from site (ii) The test report will be obtained from a authorized as per IS-10500-2012 |
| 50 | Supply only rubber flange gasket of thickness not less than 5 mm of following sizes |
| 51 | (a) 400 mm bore pipe |
| 52 | (b) 200 mm bore pipe |
| 53 | (c)150 mm bore pipe |
| 54 | (d) 100 mm bore pipe |
| 55 | (e) 80 mm bore pipe |
| 56 | Supply only PVC insulated wire/lead of copper of length 300 mm thimbled on both sides with copper thimble complete of following sizes |
| 57 | (a) 35 sqmm |
| 58 | (b) 25 sqmm |
| 59 | (c)16 sqmm |
| 60 | (d)10 sqmm |
| 61 | (e) 6 sqmm |
| 62 | S&F in repair/replacement ammeter digital type with display in existing LT panel for monitoring of Ampere 0- 500 Amp |
| 63 | S& F in repair/replacement voltmeter digital type display in existing LT panel for monitoring of voltage 0-500 volt |
| 64 | S & F PVC sintex tank in repair for chlorine dozing system as per existing model of size approx 250 ltrs |
| 65 | Supply installation & testing in repair bleaching dozer motor including replacement of nozzle,solenoid valve pipe for connection etc and amking it fully functional to thesatisfaction of Engr-in-Chg complete. |
| 66 | M&L testing & Commissioning of LT panel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 3.15 mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of following parts.(i) Incomer MCCB (a) MCCB 200 Amps FP 36 KA - (adjustable thermal and magnetic release) - 01 No |
| 67 | (ii) Outgoing MCCB (b) MCCB 100 Amps FP 36 KA - (adjustable thermal and magnetic release) - 02 No (c) MCCB 63Amps FP 36 KA - (adjustable thermal and magnetic release) - 02 No (e) MCCB 40 Amps FP 16 KA - (adjustable thermal and magnetic release) - 01 No (f) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 400 Amps all as required (g) Indication lamps for R, Y, B - 1 Nos (h) Digital voltmeter 0-500 volts with selector switch - 01 Set(j) Digital ammeter with CT's of suitable ratio & selector switch 0-440 A cap- 01 Set (k) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(l) Front operated on load change over switch 200 amps.-01 No (m) Lock pedestal - 01 No Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear/ Power Control Make of MCCB/Change Over : L&T / Legrand / Schneider / Havells/C & SMake of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender