Tender For Repair / Replacement / Maintenance Of Winter Appliances At Sgnr Mil Stn
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Nov 2026
12 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Replacement / Maintenance Of Winter Appliances At Sgnr Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | M&L for disconnecting of electric connection and dismantling complete solar water heating system of capacity 100/200 /300 ltrs (two/three panel) per day including hot & cold water pipes and hot water tank complete and refixing after repairing the system fixing back in position and testing complete all as specified and directed.Note : Rates quoted by the contractor shall deemed to be included for :-(a) Making good the worn out missing nuts bolts, washers, union sockets, flanges and screws etc.(b) Dismantling the solar panel descaling of hot water pipes by using appropriate chemicals, cleaning and washing all copper tube thoroughly cleaning the complete panel, making the tubes scale free and re-assembling the panel. (c) Cleaning hot and cold water tanks. (d) All other materials shall be measured and paid separately under respective items of BOQ. |
| 2 | S&F in replacement, copper tubes dia 1/2 inch and length 2m with collectors fins for solar energy collector panel complete of same dia and thickness as per existing, brazing by copper alloy brazing rod with the existing inlet/outlet hot/cold water pipes to make the panel water tight complete all as specified and directed. |
| 3 | S&F in repair compressed glass wool 48 mm thick between solar energy collector panel copper tubes frame and aluminum body panel including securing it on panel by means of necessary adhesives complete all as specified and directed. |
| 4 | S&F in replacement solar energy master collector panel of size (1.00m X 2.00m) made of aluminium body with toughened glass compete with copper fins of capacity 100 ltrs (one panel) per day complete all as specified and directed. |
| 5 | S&F in replacement, solar panel toughened glass (1.00m X 2.00m) having thickness 5 mm all as per the existing model of system complete all as specified and directed. |
| 6 | S&F in replacement solar energy collector panel manifold 1.40 mtr long, made of 20 mm dia copper tube having 1 No MS flange 74 mm dia welded at each end duly drilled for nuts & bolts complete all as specified and directed.Note : Rate quoted deemed to be included for welding of solar collector tubes with manifold all as directed by Engineer-in-charge and as recommended by manufacturer. |
| 7 | S&F in repair heavy duty rubber hose pipe with suitable size and thickness as per existing model ,confirming to ISI suitable for solar water heater application as per site requirement complete all as specified and directed. |
| 8 | M&L in repair hot water storage tank of food grade stainless steel 1 mm thick 200 ltr capacity with heat exchange having outer aluminium (aluminium sheet thickness 25 Gauge) cladding with 50 mm thick glass wool including taking down old one and making all electric and water connection including water supply fittings like GI union, socket, Nipples etc complete all as specified and directed. |
| 9 | All as per ser item no. 8 above but for size 300 ltrs tank complete all as specified and directed. |
| 10 | M&L for insulation of hot water pipe with black Cover pipe sleeves made out of polyethylene or neoprene foam to reduce heat losses for 20 mm bore GI pipe complete all as specified and directed by Engineer-in-charge. Note :- Bldg Height Min 15 mtr insulation of pipe to be done on down pipes of said bldgs if required complete all as specified and directed.(Note : GI pipe if replaced shall be measured and paid seperately.) |
| 11 | S&F in repairs copper heating element for solar water heater of wattage 3.0 KW, size (14\\" x 2.5\\")with thermostat pocket,M.S powder coated cap operating on 240 V AC, complete all as specified and directed. |
| 12 | S&F in repairs thermostat for solar water heater of wattage 3.0 KW operating on 240 V AC, complete all as specified and directed. |
| 13 | S & F in repairs 500 Ltrs capacity rotational moulded polythene (three layered) water storage tanks (cylindrical vertical with closed top) ISI marked, hoisted and fixed in position all as specified in SSR part I complete all as specified and directed. |
| 14 | M&L for repair & servicing of 50 Ltr capacity storage type electric water heater of any make/size comprising of the followings :- (a) Inspection, taking down , opening ( dismentaling ) descaling , brushing , cleaning of storage tank internally complete all as specified and directed. Repair to leakage if any shall be measured and paid separately under relevent item of BOQ). (b) Examine water tightness of storage tank after cleaning. (c ) Check out operation of all stop cocks , pressure reducing valves etc. to ensures free movement of the working parts. (d) Replace washers and glands of all taps and ball valves to ensure water tightness. (e) Inspect overflow / vent pipes and remove blockages obstructions if any.(f) Check and correct earth continuty of eletrical items.(g) Check maintain and refit thermostates and test its functioning.(h) Checking and adjustment of pressure reducing valves. (j) Checking of dead weight type high pressure release valve (PRV) by removing dead weight properly cleaning the seat and ensuring that the vent hole is not blocked / chocked.(k) Visual examination of fusible plug to ensure its intactness.(l) Descaling of the immertion type heating element and cleaning with diluted hydrocloric acid or clear pedette solution and testing before refixing (m) Replacement / repair of neon lamp/indicator lamp.(n) Replacement of the rubber /pvc gasket to ensure water tightness. (o) New item when ever required shall be paid under respective item of BOQ item as supply only but fixing of the same is including in the rates of the above item.Note:- All urgent complaints will be rectified within 6 hrs failing which recovery @ Rs. 200/- per complaint will be recovered after 6 hrs. |
| 15 | All as per serial item no 14 above but for water heater of capacity 25 ltrs complete all as specified and directed. |
| 16 | Supply only thermostates (ISI marked) size 11\\" suitable for 25/50 ltrs capacity geyser complete all as specified and directed. |
| 17 | Supply only airex triangle type geyser heating element of 1.5 KW (colour-silver), length 11\\", made of copper of suitable size and shape,including rubber washers (ISI marked) with clamps complete all as specified and directed. |
| 18 | Supply only airex triangle type geyser heating element of 2 KW (colour-silver), length 11\\", made of copper of suitable size and shape,including rubber washers (ISI marked) with clamps complete all as specified and directed. |
| 19 | Supply only apparatus plate for 25/50 ltrs capacity geysers includng rubber gasket/ screw/ nut bolt of required size including making thread if required complete all as specified and directed.Note for Sl Item No. 16 to 19 :- Fixing cost included in Sl Item No. 14 & 15 above. |
| 20 | S&F in repair 15mm dia PVC connection pipes suitable for hot water with brass hexagonal adaptors both side, 60 cm long complete all as specified and directed. |
| 21 | M & L for repair to leakage of copper/stainless steel of water heater by necessary welding/brazing complete all as specified and directed. |
| 22 | M & L for preparation of steel surface and applying one coat of synthetic enamelled paint with spray gun including writing of MES Nos with black paint complete all as directed for 25 Ltrs capacity geyser complete all as specified and directed. |
| 23 | M & L for Cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate for foundations, fillings and mass concrete complete as specified and directed. |
| 24 | M & L for Cross arms, bracings, supports, clamps and back plates fabricated from mild steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat of red oxide, one under coat and one finish coat of synthetic enamel paint complete all as specified and directed. |
| 25 | S & F in repairs 20mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 26 | S & F in repairs 20 mm bore medium grade GI tubes, with all necessary fittings laid on walls & ceiling or laid in floor complete all as specified and directed. |
| 27 | S & F in repairs 15 mm bore medium grade GI tubes, with all necessary fittings laid on wall & ceiling or laid in floor all as specified and directed. |
| 28 | Cutting existing 20 mm/15 mm bore GI tubing for alteration or addition including fitting such as Union/Tee/Nipple/Socket of suitable size complete all as specified and directed. |
| 29 | S & F in repairs 15 mm brass stop valve, cast copper alloy screwed down, fancy type, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or fixed on wall complete all as specified and directed. |
| 30 | S & F in repair sheet metal single pole and neutral enclosure 240 volts with a two pin and earth plug and socket complete with 20 Amp single pole MCB complete all as specified and directed. |
| 31 | Supply and fixing copper conductor of size 4 Sqmm twin core FRLSH type complete all as specified and directed. Please Enable Macros to View BoQ information |
| 32 | Supply and fixing copper conductor of size 4 Sqmm twin core FRLSH type complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender