Tender for Repairs To False Ceiling, Plaster To Column, Beams, Ceiling, Plumbing, Tiling, Leakage, Seepage & Misc Wk At Dgqa Complex Under Ge (C) Kolkata
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE ( C ) KOLKATA NAME OF WORK: REPAIRS TO FALSE CEILING, PLASTER TO COLUMN, BEAMS, CEILING, PLUMBING, TILING, LEAKAGE, SEEPAGE & MISC WK AT DGQA COMPLEX UNDER GE (C) KOLKATA Contract No: GE (C )/KOL/ OF 2026-27 (8997) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # ItemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Material and labour Chipping of unsound/weak concrete materials of from column/beam with standard power driven percussion type or pneumatic chiesel of standard make including tapering all edges, making square shoulders of cavities etc upto four storey height of building including necessary scaffolding and safety measure complete all as specified and as directed by the Engr-in-Charge. |
| 3 | Material and labour Chipping of unsound/weak concrete materials of from slabs/chajja/ fin fascia with lightly packing with standard power driven percussion type or pneumstic chiesel of standard make materials by air blasting or sand blasting including tapering all edges, making square shoulders of cavities etc upto four storey height of building including necessary scaffolding and safety measure complete all as specified and as directed by the Engr-in-Charge. |
| 4 | Material and labour Removing concrete all around reinforcement including behind of reinforcement bars to give an average clearance of 25mm (but not less than 15mm clear air gap) by manual methods (hammering and using wire brushes, chieselling etc.) and applying alkaline rust removing chemical followed by removing rust including from behind the reinfircement bars by emery paper and cleaning the area throughly by water and alllow it to dry as per manufacturer's instructions to provide totally rust free finished steel surfaces, length of reinforcement bars cleared of concrete shall be measured for payment including upto four storey height of building upto 12mm dia of bars complete all as specified and as directed by the Engr-in-Charge. |
| 5 | Material and labour for applying single coat of epoxy bond adhesive on prepared non metallic surface (existing surface) by using brush as per manufacturers instruction / specification upto any height including necessary scaffolding and safety measures complete all as directed by the Engr-in-Charge. |
| 6 | Material and labour Removing concrete all around 16 mm dia reinforcement including behind of reinforcement bars to give an average clearance of 25mm (but not less than 15mm clear air gap) by manual methods (hammering and using wire brushes, chieselling etc.) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcement bars by emery paper and cleaning the area throughly by water and alllow it to dry as per manufacturer's instructions to provide totally rust free finished steel surfaces, length of reinforcement bars cleared of concrete shall be measured for payment including upto four storey height of building upto 16mm dia of bars complete all as specified and as directed by the Engr-in-Charge. Make:- Fosroc/Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano |
| 7 | Supply and application Epoxy Zinc rich primer on the prepared reinforced surface by brush, the primer shall have a minimum specific gravity 1.75, minimum wet film thickness/coat 100 microns & dry film thickness/coat 40 microns. Minimum adhesive bond strength with steel is 1.5 N/mm2 upto upto four storey height of building complete all as specified and as directed by the Engr-in-Charge. Make : Fosroc/Elantas beck/Kunal conchem/ Sika /Hindcon Chemicals Ltd/ Icannano |
| 8 | M&L Pressure guniting at a pressure not less that 6Kg/Sqcm to surface of column, beam, ceiling, facia and similiar structural members in polymer modified concrete with mix ratio 1:1.5:3 (1 cement : 1.5 Coarse Sand : 3 Stone aggregate of 10mm nominal size) admixed with acrylic latex polymer such as Hind Styrene BR/Nitobond SBR (M/s Hindcon) or equivalent from M/s Pidilite/Forsoc @ 3.00 Kg per Sqm and plasticiser Hind Plast Super/Conplast SP 337 (M/s Hindcon) or equivalent from M/s Pidilite/Forsoc @ 100Gms per Sqm for an average thickness of 50mm (the concrete to be applied when the bonding coat is still green) including material and labour, scaffolding and formwork etc. as per manufacturer's specification complete all as per direction of Engineer-in-Charge. |
| 9 | Supply and Application Free flow non-shrink cementitious micro concrete of grade M50 to the affected beam, column etc above 25 mm and upto 60mm thickness (average) where major spalling has taken place even the core of concrete affected. The Micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, Minimum tensile strength 5 N/mm2 @ 28 days, minimum Flexural strength 5 N/mm2@ 28 days tested as per BS 4551-80, Expansion characteristics Unrestrained expansion as per ASTM C827-1987 1 to 4%. upto only height of building complete all as specified and as directed by the Engr-in-Charge.Make:- Fosroc/Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano |
| 10 | Supply and Application Two component structural grade polymer modified reinstatement mortar where local spalling has taken place or shuttering is not possible. The Mortar can be applied from a minimum of 5mm to 12.5mm thickness in smaller vertical pockets and upto 100 mm thickness in horizontal applications. The Mortar should have a minimum compressive strength 12 N/mm² in 1 day and 45N/mm² in 28 days. Minimum Flexural strength should be 8 N/mm² in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementitous systems to be mixed with cement slurry before the application of microconcrete to be used @ 6 lit/bag of cement. The bonding agent should have minimum compressive strength 24 N/mm² Minimum Tensile strength 3.5 N/mm², Minimum Flexural Strength 6.5 N/mm² complete all as specified and as directed by the Engr-in-Charge upto any height of building including necessary scaffolding and safety measure.Make : Fosroc/Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano |
| 11 | Material and labour applying Concure LP 90 or equivalent over concrete and cement plaster as curing compund as per manufactures instructions including necessary scaffolding and safety measures complete all as specified and as directed by the Engr-in-Charge. Make : Fosroc/Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano |
| 12 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. (upto 04 Storey high of building) |
| 13 | Use and waste of Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, upto 04 storey high of building) complete all as specified and as directed. |
| 14 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.(upto 04 Storey high of building) |
| 15 | S&F TMT bars 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. (upto 04 Storey high of building) |
| 16 | M&L Reinforced Cement Concrete type B1(1:2:4), using 20 mm graded crushed stone aggregate, as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like similar works complete all as specified and directed.(upto 04 Storey high of building) |
| 17 | M&L Reinforced Cement Concrete type B1(1:2:4) using 20 mm graded crushed stone aggregate as in Chajja complete all as specified and directed.(upto 04 Storey high of building) |
| 18 | S&F 5mm thick PVC sheet fillet of width 35mm for paneling inclusive of fixing on to wall to make PVC frame as per specified complete all as specified and directed |
| 19 | M&L Solid PVC Wall Lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing including taking down the old and complete all as specified and directed |
| 20 | Dismantling of Wall and Ceiling Board (Fibre, Pulp, Insulation etc.) or Insulation Board/Slab /Blankets, any thickness including Cover Fillets, complete all as specified and as directed. |
| 21 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre With Reinforced Gypsum) Semi perforated 12mm thick micro tegular semi false ceiling tiles of size 595 x 595 mm of approved texture, content less than 2% humidity resistance edged GRG thick square edged of 99% NRC 0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles 4 76 (part 4) - 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross T of size 15 x 32 mm of length of 1200mm and secondary intermediate T-Cross of size 15 x 32 mm of length 600mm to form grid module of size 600 x600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners,6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85 x 25 x 2 mm. Galvanised iron perimeter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 tiles fully mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 22 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including nainital or similar roof coverings/sunshade, complete all as specified and as directed |
| 23 | S&F Pre-painted colour galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall /sunshade etc, fixed with self tapping screws complete all as specified and as directed. |
| 24 | S&F Except Sheeting Pre-painted colour galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall /sunshade etc, fixed with self tapping screws complete all as specified and as directed. |
| 25 | S&F Pre-painted colour galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall /sunshade etc, fixed with self tapping screws complete including dismantling old unserviceable roof sheet all as specified and as directed. |
| 26 | Stripping of old tarfelt including layer of plaster or morter of any type treatement carefully from roof surfaces (without damage of roof) and roughening of surface of old concrete roofing by picking sweeping cleaning and washing down with water to remove dust as directed. |
| 27 | M&L 20mm thick screed bed or bedding layer in CM 1:4 surface finished even and smooth without using extra cement for padding complete all as specified and directed |
| 28 | M&L for applying tack coat industrial bitumen 85/25 at the rate of 1.2Kg/sqm including cleaning of surface and laying of APP based polymeric membrance minimum weighing not less than 3Kg/sqm and minimum 3mm thick reinforced with polysiter non wove fabric (wt not less than 150gms/sqm) laid on priming surfaces by forced application and apply one coat of aluminium paint complete all as specified and directed |
| 29 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in mortar complete all as specified and directed. |
| 30 | M&L 18-20mm thick Granite of any type work (table rubbed and polished) in steps, jambs, pillar, window cills, cooking plateform and like in CM (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shades of granite incl 15mm thick cement plaster in CM 1:4 incl necessary edge moulding/champering complete all as directed by Engr-in-Charge |
| 31 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) removing serviceble tiles to store and rubbish off the premises complete all as specified and as directed. |
| 32 | M&L Coloured /digital vitrified ceramic floor tiles dark shed 10 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n. exc. 0.36 sqm (600mm x 600mm x 10mm) as in floor etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor make incl 15 mm thick screed bed or bedding of layers in CM 1:6 complete all as specified and as directed. |
| 33 | M&L Vitrified ceramic tiles , double / ultra charged, 9-10 mm thick (square / rectangular) polished, area of each tiles exc 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed . |
| 34 | M&L glazed ceramic coloured tiles 450x300x7-8mm in vertical surfaces set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed |
| 35 | M&L joint free non skid ceramic coloured tiles 7-8mm thick (square/rectangular) area of each tile not exceeding 0.11 Sqm in floor set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 36 | M&L joint free non skid ceramic coloured tiles 7-8mm thick (square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 37 | M&L for Chequered cement concrete tiles of size 300mm x 300mm x25mm thick, with grey cement and no pigment, jointed in neat cemnt slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 including taking down unserviceable tiles complete all as specified and directed. |
| 38 | Supply and Fix non skid external paver Tiles of size 300mm x300mmx 10mm thick, suitable for hi-turf external tiles, anti skid, scratch resistance and neutral to UV rays and acid/ alkali resistance as in floor over and including 15mm thick cement sand screed bed 15mm thick 1:4 complete all as specified and as directed. |
| 39 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. |
| 40 | M&L Brick work using pulverized fly ash bricks designation 75 (kgf/cm2) straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed. |
| 41 | M&L half brick thick brick work using pulverized fly ash bricks designation 75 (kgf/cm2) straigth or curved on plan to any radius built in CM (1:4) complete all as specified and directed |
| 42 | ditto - all as above items No 39 here-in-before but except bricks |
| 43 | Taking down cement plaster of any description on brick work or stone msonary wall including racking out joints hacking for key scrubbing down with water etc. complete all as specified and directed |
| 44 | M&L rendering 15mm thick in CM (1:6) on other than fair faces of brick work or concrete surfaces even & smooth without using extra cement complete all as specified and directed |
| 45 | M&L rendering 5mm thick in CM (1:3) as in ceiling/chajja surfaces even & smooth without using extra cement complete all as specified and directed |
| 46 | M&L 20 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete external surfaces in two layers (each 10mm thick) finished even and smooth without using extra cement and using water proofing compound on top layer @2% by weight of cement or as per manufactures instruction on external wall surface upto height of 4th storied bldg complete all as specified and directed.Note : WPC shall be measured and paid seperately |
| 47 | Supply only liquid water proofing compound (ISI marked) complete all as specified and directed.Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA/Icannano |
| 48 | M&L prearation of new plastered surface of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resisatance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90litre/10sqm over new surface complete all as specified and directed |
| 49 | M&L for preparing newly plastered surfaces of wall and priming plastered and other surfaces with alkali resistant priming paint on plastered surface and applying two coats of oil bound distemper over a coat of 1 mm thick wall care puty all as specified and directed |
| 50 | M&L for preparation of new plastered surface of ceiling and applying two coats of oil bound distemper over one coat of primer Chalk whiting, on plastered surface complete all as specified and directed |
| 51 | M&L prepartion of existing old ceiling surfaces and applying one coat of oil bound distemper (any colour/tint) on ceiling surface complete all as directed and specified |
| 52 | M&L for complete removal of existing treatment of old surfaces and applying two coats of oil bound distemper (any colour/tint) over a coat of primer (Asian Paint / Berger Paints) including a coat (approx 1.5mm thick) of white cement based putty complete all as directed and specified. |
| 53 | M&L Preparing of existing old surfaces and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed. |
| 54 | Dismantling of MS work of any description and any position all as directed. |
| 55 | M & L Mild steel Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 56 | M&L Mild Steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe 410 Gde-E-250 quality-A complete all as specified and directed. |
| 57 | M&L Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel plaint over a coat of red oxide all as specified and directed by Engineer-in-Charge. |
| 58 | Demolition of plain cement concrete (Un-reinforced) of any description and in any position not otherwise specifically provided for upto 4 storey bldg height all as specified and directed. |
| 59 | M&L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 60 | M&L 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection laid in panels, finish the top surfaces even and smooth without using extra cement complete all as specified and directed |
| 61 | M&L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) as in surface channel and drain all as specified and directed. |
| 62 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 63 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm as in Soft/Loose Soil, complete all as specified and as directed. |
| 64 | Removing excavated material ( soils of any type) n exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 65 | M&L concrete bed (1:3:6) type C-2 (Using 40mm graded crushed stone aggregate) to 150mm dia drain pipes including packing under, and haunching against the sides of pipe after they are laid and tested complete all as specified and directed |
| 66 | S&F Salt-Glazed Stoneware Drain Pipes of Internal dia 150mm Grade ‘A’, laid in concrete bed at trenches, jointed in Cement Mortar 1:1 and tested, complete all as specified and as directed. |
| 67 | M&L Cleaning of existing 100mm dia / 150mm dia sewage line upto 1.50m depth from ground level using jute or PVC nylon rope with knot at one end and other end free passed through the line or by rodding & removing all liquid / semi liquid / solid sludge etc including dewatering, desilting and well flushing the line with water and testing on completion complete as directed by the Engineer-in-Charge.Note:-(i) Once cleaned the sewage lines, the Contractor shall maintain the lines functional upto the date of Completion at his own cost.(ii) Any damged done by the Contractor during cleaning shall be make good by the Contractor at his own cost upto the satisfaction of Engineer-in-Charge. |
| 68 | Cleaning of existing 200mm dia sewage line upto 1.50m depth from ground level using jute or PVC nylon rope with knot at one end and other end free passed through the line or by rodding & removing all liquid / semi liquid / solid sludge etc including dewatering, desilting and well flushing the line with water and testing on completion complete as directed by the Engineer-in-Charge.Note:-(i) Once cleaned the sewage lines, the Contractor shall maintain the lines functional upto the date of Completion at his own cost.(ii) Any damged done by the Contractor during cleaning shall be make good by the Contractor at his own cost upto the satisfaction of Engineer-in-Charge. |
| 69 | Lifting of cover and desilting of blocked manhole, of any size and depth by mechanised suction machine and removal of sludges in water sealed container to a distance outside residential area and washing with adequate quantity of water and refixing the cover in the same location and cutting of bushes all around the manholes up to 1.0 m radius including burring the sludge in a pit spreading bleaching powder with sufficient quantity surrounding it and sealing the pit with fine sand and spreading bleeching powder surrounding the pit etc complete all as specified and as directed by Engr-in-Charge.Note:-(i) Cost of earth work in excavation required for digging the borrow pit and burring the the waste materials / sludge in the borrow pit and sealing the pit with fine sand & spreading bleaching powder shall deemed to be included in the rate quoted.(ii) Any damged done by the Contractor during cleaning shall be make good by the Contractor at his own cost upto the satisfaction of Enginner-in-Charge. |
| 70 | S&F 450mm dia 50mm thick RCPC (Reinforced Cement Polymer Concrete) Man hole cover slab of 3MT capacity fixed in proper position as in repair complete all as specified and as directed. |
| 71 | S&F 750x450mm and thick RCPC (Reinforced Cement Polymer Concrete) Drain cover slab of 3MT capacity fixed in proper position as in repair complete all as specified and as directed. |
| 72 | M&L Uprooting of tree from walls of bldgs up to extended root and spraying of acid of required quantity complete from any location of Bldg up to 4 storied and making good disturbed surfaces with cement mortar (1:4) or cement concrete type C1(1:3:6) using 20mm graded aggregate including necessary scafolding complete for tree of girth up to 5cm to10 cm complete all as specified and as directed. |
| 73 | Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches of 100 mm internal dia complete all as specified and as direceted. |
| 74 | S&F for 110mm bore UPVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed.(upto 4 storey high of each building) |
| 75 | S&F for 110mm bore UPVC (SWR) pipe bend single socketed complete in all as specified and directed.(upto 4 storey high of each building) |
| 76 | S&F PVC (SWR) Junction 110mm bore (dia), Single (Single T) equal or unequal and Jointing with Solvent Cement, complete all as specified and as directed. |
| 77 | M&L Cleaning of all debris / vegitation over roof surfaces of accessible or unaccessible roof portion upto any height and the mouth of rain water pipe and around the tanks area and removal of materials outside the MOD land including necessary scaffolding and safety measures complete all as directed by Engineer-in-Charge. |
| 78 | S&F in repair vitreous china EWC cascade type white including cistern, seat cover, inlet accessories complete all as specified and as directed by Engr-in-Charge.Make - Parryware, Cat Part No -C844A Qube or technocommerically equivalent in model from make approved |
| 79 | Disconnecting existing tanks of capacity exc 250 & not exc 2000 liters setting aside (or lowering, hoisting if required) for repairs & scrubbing cleaning, thoroughly removing all scale and dirt, mud sediments, silts etc from the internal surfaces of PVC/RCC water storage tanks (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required and removing vegetation/ Algae around the over head tank after opening tank cover, inlet, outlet etc and reconnecting with GI/CPVC tubing and re-fixing in position , refixing the cover after cleaning all and specified and directed.Note: While cleaning Any CI/GI/PVC pipes and fittings, Float valve damaged during work shall be replaced by new one to insure leakage / seepage free joint without any extra cost to the department and Unit rate quoted by tenderer shall includ for use of all scaffolding, protective measures etc up to four storeys height of bldgs. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender