Tender For Repair And Maintenance Of Split/ Window Acs, Water Coolers Refrigeration Deep Freezer Units At Core Area, Otm Accn At Site A1 & Site A2 Of Naval Base Karwar.
Tender Value
47.70 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
2 days left
EMD
95400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Split/ Window Acs, Water Coolers Refrigeration Deep Freezer Units At Core Area, Otm Accn At Site A1 & Site A2 Of Naval Base Karwar.
BOQ
| Sl. No. | Item Description |
| 1 | Comprehensive maintenance and servicing of split-type air conditioner / window-type air conditioner / deep freezer / floor-mounted unit of any capacity, including both outdoor and indoor units of any make, including cleaning the dust from the body with a blower, cleaning of condenser and cooling coil, checking all connections, including functioning of metal-clad socket/DP switch, functioning of relay, capacitors, overload protector, thermostat, fan motor, fan motor blade/blower drum, main control board PCB, electronic control box, etc., oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woollen felt and refixing, ensuring airtightness, complete; repair and replacement of worn-out/unserviceable spares, including taking down and refixing, transportation to and from the workshop, if required, and refixing in its original place after fully servicing, including testing, cleaning of the area made dirty during cleaning, and commissioning, all as specified and directed by Engineer-in-Charge. Note:(i) Spare parts replaced shall be measured and paid for separately under the relevant item of this BOQ.(ii) Supply and charging of nitrogen/refrigerant gas shall be measured and paid for separately under the relevant item of this BOQ. |
| 2 | M&L for rectification of defects and making functional deep freezer, split-type/floor-mounted AC, water cooler and refrigerator of any capacity and existing make, including rectification of minor defects such as tripping of MCBs, wherever necessary, rectifying loose electrical connections, making fresh connections in the electrical panel/connector, etc., making functional defective drain pipe blockage/leakage, etc., checking the functionality of the compressor of any capacity, etc., complete, all as specified and directed. |
| 3 | Supply only thermostat switch suitable for air conditioner operating on single-phase 230 V supply, all as specified and directed. |
| 4 | Supply only drier filter for water cooler all as specified and directed. |
| 5 | Supply only magnetic contactor for the outdoor unit of split-type air conditioner, as per the existing type, complete, all as specified and directed. |
| 6 | Supply only capillary tubes for air conditioners of 1.5-ton/2-ton capacity and water coolers of 40 to 150 litres capacity. |
| 7 | Supply only remote control unit for split-type AC of 1.5-ton/2.0-ton capacity, including frequency arrangement of the new remote with the existing system, all as specified and directed by Engineer-in-Charge. |
| 8 | Supply only capillary tubes for refrigerators and deep freezers up to 400 litres capacity. |
| 9 | S&F push taps, self-closing, of 15 mm size, made of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler complete in repair all as specified and directed. |
| 10 | S&F copper condenser coil of size 20 × 30 inches, single-row, suitable for 1.5 TR outdoor unit of split AC complete in repairs all as specified and directed. |
| 11 | S&F copper condenser coil of size 22 × 32 inches, single-row, suitable for 1.5/2.0 TR outdoor unit of split AC complete in repairs all as specified and directed. |
| 12 | Supply only refrigerant gas R-22, R-134a, R-32 and R-410A, in the required quantity, for charging the refrigeration circuit of AC of 1.5/2.0-ton capacity, complete, all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for detecting gas leakage with the help of nitrogen gas, rectifying defects, including repair to condenser coil/evaporator coil by means of welding, soldering, etc., vacuumising and charging/topping up with fresh Freon gas/R-22, and commissioning and testing for 1.5-ton/2.0-ton split-type/window-type AC, all as specified and directed by Engineer-in-Charge. |
| 14 | Repair, replacement, supply, installation, testing and commissioning of a new hermetically sealed compressor for Split-type AC of 1.5 TR capacity, duly charged with fresh Freon gas/R-134a, complete, all as specified and directed by Engineer-in-Charge, including taking down the old unserviceable compressor. |
| 15 | Repair, replacement, supply, installation, testing and commissioning of a new hermetically sealed compressor for Split-type AC of 2.0 TR capacity, duly charged with fresh Freon gas/R-134a, complete, all as specified and directed by Engineer-in-Charge, including taking down the old unserviceable compressor. |
| 16 | Repair, replacement, supply, installation, testing and commissioning of a new hermetically sealed compressor for Water cooler of 40 to 80 litres capacity, duly charged with fresh Freon gas/R-134a, complete, all as specified and directed by Engineer-in-Charge, including taking down the old unserviceable compressor. |
| 17 | Repair, replacement, supply, installation, testing and commissioning of a new hermetically sealed compressor for Water cooler of 120 to 150 litres capacity, duly charged with fresh Freon gas/R-134a, complete, all as specified and directed by Engineer-in-Charge, including taking down the old unserviceable compressor. |
| 18 | Supply, fix, test and commission PCB set for inverter split AC of 1.5 TR capacity, compatible with the existing split AC, complete in repair, all as specified and directed. |
| 19 | S&F indoor unit of inverter-type split AC of 1.5 TR capacity, with multidirectional airflow, four-way swing, copper-coil heat exchanger, auto-restart, temperature-sensing and safety-protection sensors, single-phase 230 V/50 Hz, 5-star rating, complete in repairs, all as specified by Engineer-in-Charge. |
| 20 | S&F outdoor unit of inverter-type split AC of 1.5-ton capacity, with nominal inverter compressor incorporating variable-speed technology, eco-friendly refrigerant, copper condenser coil with suitable anti-corrosion coating, high-efficiency air-cooled condenser, outdoor fan motor, compressor protection against overload, overcurrent, high/low pressure and temperature, and minimum 5-star latest applicable BEE rating, complete in repairs, all as specified by Engineer-in-Charge. |
| 21 | S&F fan motor, single-phase 240 V, metallic body, for outdoor unit of split AC suitable for 1.5/2-ton capacity, matching the existing RPM and setting, complete in repairs all as specified and directed. |
| 22 | S&F fan motor, single-phase 240 V, metallic body, for indoor unit of split AC suitable for 1.5/2-ton capacity, matching the existing RPM and setting, complete in repairs all as specified and directed. |
| 23 | S&F fan blade assembly with aluminium frame for the outdoor unit of split AC of any capacity and existing make, complete in repairs all as specified and directed. |
| 24 | S&F PVC air filter for split-type AC of 1.5/2-ton capacity, complete in repairs all as specified and directed. |
| 25 | S&F pendant control assembly with cord and PC circuit, suitable for existing split-type AC of 1.5-ton capacity, complete in repairs, all as specified and directed. |
| 26 | S&F LMS and overload relay assembly for 1.5/2-ton compressor of split-type AC, complete in repairs, all as specified and directed. |
| 27 | S&F copper tube of 5/8-inch size for indoor unit of split AC, including brazing, complete in repairs, all as specified and directed. |
| 28 | S&F copper tube of 3/8-inch size for indoor unit of split AC, including brazing, complete in repairs, all as specified and directed. |
| 29 | S&F copper tube of 1/4-inch size for indoor unit of split AC, including brazing, complete in repairs, all as specified and directed. |
| 30 | S&F 15 A, 240 V, heavy-duty plug top, complete in repairs all as specified and directed. |
| 31 | S&F copper tube insulation with Heatlon or Superlon insulation material, complete in repairs, all as specified and directed. |
| 32 | S&F single-pole and neutral enclosure with a two-pin-and-earth plug and socket, complete with one 20 A, single-pole MCB, 240 V, complete in repairs all as specified and directed. |
| 33 | S&F capacitor of 1.5 to 6 MFD, 230 V, single-phase, complete in repairs, all as specified and directed. |
| 34 | S&F capacitor of 36–45 MFD, 230 V, single-phase, complete in repairs, all as specified and directed. |
| 35 | S&F auto-swing motor suitable for the indoor unit, as per the existing 240 V AC single-phase system, complete in repairs, all as specified and directed. |
| 36 | S&F single-phase contactor, model 3 TH 30, 22 E, suitable for the outdoor unit of 2 × 1.5-ton capacity of existing make, complete in repairs all as specified and directed. |
| 37 | M&L for shifting split AC of 1.5 TR and 2.0 TR capacity, including all accessories, and installation at a new location, including fixing arrangements for indoor/outdoor units along with mounting brackets/frame, cutting holes in the wall and making good the disturbed surfaces to match the existing wall finish, etc., complete, all as shown and directed by Engineer-in-Charge. Note: Additional copper tubing and gas charging, as required to make the existing AC serviceable at the new location, shall be measured and paid for separately. All other items shall be deemed to be included in the unit rate quoted. |
| 38 | S&F/lay 20 mm bore PVC pipe along walls for draining condensate water from split AC, including cutting of floors/openings in walls for laying the pipe and making good the same after fixing/laying the pipe, complete in repairs, all as specified and directed. |
| 39 | S&F voltage stabiliser for automatic operation, single-phase, naturally air-cooled, indoor type, designed for input voltage variation between 170 V and 250 V, with output voltage stabilised at 230 V with an accuracy of ±2.50%, and of 4 kVA capacity complete in repairs all as specified and directed. |
| 40 | S&F outdoor stand for mounting the outdoor unit of split AC, complete in repairs, all as specified and directed. |
| 41 | S&F flexible cable, 4-core, copper conductor, 2.5 sq. mm, complete in repairs, all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender