Tender For Addition/ Alteration And Improvement Including Replacement Of Corroded Water Pipe Line At construction Park Under Ge (U-Ii) Visakhapatnam
Tender Value
44.90 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
2 days left
EMD
89800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition/ Alteration And Improvement Including Replacement Of Corroded Water Pipe Line At construction Park Under Ge (U-Ii) Visakhapatnam
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, laying, jointing, testing and commissioning of 200mm dia, class K-9, Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces, complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Supplying, laying, jointing, testing and commissioning of 150mm dia, class K-9, Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces, complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Material and Labour for DI fittings (Class K-12) suitable for DI spigot and socketed pipe of size from 150 mm to 300 mm bore and any type such as MJ Collar, Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket/flanged etc), Tee pieces (single branch, \\"Y\\" junction, double branch, cross etc), collars, caps and plugs etc, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Taking down old rusted/unservicable GI pipe 80 mm dia including fittings/valves complete all as specified and directed by Engineer-in-Charge. |
| 5 | Taking down old rusted/unservicable GI pipe 50 mm dia including fittings/valves complete all as specified and directed by Engineer-in-Charge. |
| 6 | Taking down old rusted/unservicable GI pipe 25 mm dia including fittings/valves complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and laying/fixing of 3 layer (inner antimicrobial, outer UV stablised) ISI marked, IS 15801, PP-R pipes SDR 7.4 (PN-16) including PP-R plain/brass fittings in trenches/walls/ceiling or laying in floors complete of size outer dia 90 mm complete all as specified and directed by Engr-in-Charge |
| 8 | Supply and laying/fixing of 3 layer (inner antimicrobial, outer UV stablised) ISI marked, IS 15801, PP-R pipes SDR 7.4 (PN-16) including PP-R plain fittings in trenches/walls/ceiling or laying in floors complete of size outer dia 63 mm complete all as specified and directed by Engr-in-Charge |
| 9 | Supply and laying/fixing of 3 layer (inner antimicrobial, outer UV stablised) ISI marked, IS 15801, PP-R pipes SDR 7.4 (PN-16) including PP-R plain/brass fittings in trenches/walls/ceiling or laying in floors complete of size outer dia 32 mm complete all as specified and directed by Engr-in-Charge |
| 10 | Taking down old rusted/unservicable sluice valve of 200 mm dia complete all as specified and directed by Engineer-in-Charge. |
| 11 | Taking down old rusted/unservicable sluice valve of 150 mm dia complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply and fix Cast Iron Rising Spindle Sluice Valve of size 200mm nominal bore, PN 1.6, as per IS : 14846 with flanged ends, hand wheel operated, stainless steel stem including necessary packing material, GI bolts, nuts and washers etc, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply and fix Cast Iron Rising Spindle Sluice Valve of size 150mm nominal bore, PN 1.6, as per IS : 14846 with flanged ends, hand wheel operated, stainless steel stem including necessary packing material, GI bolts, nuts and washers etc, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply and fix PP-R Gate valves (brass insert) suitable for 90 mm PP-R pipe, complete all as specified and directed by Enginee-in-Charge. |
| 15 | Supply and fix PP-R Gate valves (brass insert) suitable for 63 mm PP-R pipe, complete all as specified and directed by Enginee-in-Charge. |
| 16 | Supply and fix PP-R Gate valves (brass insert) suitable for 32 mm PP-R pipe, complete all as specified and directed by Enginee-in-Charge. |
| 17 | Material and labour for cutting of existing bitumen road / foor/CC road / PCC hard standing up to 30 cm depth and 60 cm width for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying/fixing of pipes, complete all as specified and directed. Note:- Excavation beyond 30 cm depth shall be measured and separately . |
| 18 | Material and labour for constructing valve chamber of internal dimensions 900mm x 900 mm x 1200 mm with 100 mm thick PCC (1:4:8 ) type D-2 for foundation, brick walls built in cement mortar (1:4 ), PCC 1:2:4 type B1 for coping , rendering in cement mortar 1:4, 15 mm thick internally and on exposed surfaces externally up to 15 cm above GL. Bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space. The sluice valve and other fittings should be housed in center of the pit, the vertices of the pit should be in right angle and champhered .The top cover of the pit will be made out of 3mm MS sheet with angle iron frame made out of MS angle 50mm x 50 mm x 6 mm with MS hinges two Nos, and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide primer, including demolition and taking out of existing broken valve chamber of any description, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Material and labour for constructing valve chamber of internal dimensions 1000 mm x1000mm x1200mm with 100 mm thick PCC (1:4:8 ) type D-2 for foundation, brick walls built in cement mortar (1:4 ), PCC 1:2:4 type B1 for coping , rendering in cement mortar 1:4, 15 mm thick internally and on exposed surfaces externally up to 15 cm above GL. Bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space. The sluice valve and other fittings should be housed in center of the pit, the vertices of the pit should be in right angle and champhered .The top cover of the pit will be made out of 3mm MS sheet with angle iron frame made out of MS angle 50mm x 50 mm x 6 mm with MS hinges two Nos, and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide primer, including demolition and taking out of existing broken valve chamber of any description, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in any type soil for laying pipes etc, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 23 | SCHEDULE OF CREDITNote :- Amount of Rs. 1,31,025.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender