Tender For Maintenance Work For Increasing The Depth Of Existing Drain And Repair/Restoration Of Affected Plinth Protection At Academic Block A-02, South Campus, Iit Mandi.Note:-1. Quoted Rate Should Be Inclusive Of All Applicable Taxes Including Gst
Tender Overview
Project Description
Tender for Maintenance Work For Increasing The Depth Of Existing Drain And Repair/Restoration Of Affected Plinth Protection At Academic Block A-02, South Campus, Iit Mandi.Note:-1. Quoted Rate Should Be Inclusive Of All Applicable Taxes Including Gst (Nothing Extra Shall Be Payable).2. All Statutory Deduction Will Be Made As Per Prevailing Rates.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil. |
| 2 | Excavating trenches by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :a) All kinds of soili) Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:a) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:a) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for :a) Foundations, footings, bases for columns |
| 6 | Providing and laying in position specified grade of reinforced cemen concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.a) Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 8 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 9 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 10 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.a) 40 mm wide and 4 mm thick |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :a) Two or more coats on new work |
| 12 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 13 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge.a) Nominal concrete 1:3:6 or richer mix (including equivalentdesign mix) |
| 14 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as perstandard design :a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight offrame 15 kg) :i) With common burnt clay F.P.S. (non- modular) bricks of class designation 7.5 |
| 15 | Extra for depth for manholes :a) Size 90x80 cmi) With common burnt clay F.P.S. (non- modular) bricks of class designation 7.5 |
| 16 | Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer-in-charge:a) Rectangular manhole 90x80 cm and 45 cm deep |
| 17 | Extra for depth of manholes dismantled :a) Rectangular manhole 90x80 cm and beyond 45 cm depth |
| 18 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 200 mm diameter as per entire satisfaction and direction of Engineer in Charge. |
| 19 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 200mm bend/Door bend as per entire satisfaction and direction of Engineer in Charge. |
| 20 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length complete. 200 mm as per entire satisfaction and direction of Engineer in Charge. |
| 21 | Supplying and fixing C.I. cover with frame for manholes: 455x610 mm internal dimensions, C.I. cover with frame (light duty):total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) as per entire satisfaction and direction of Engineer in Charge. |
| 22 | Supplying and fixing C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: as per entire satisfaction and direction of Engineer in Charge. |
| 23 | Providing and fixing 110mm dia Unplasticized rigid PVC pipe of required size for weep holes in plum concrete walls including cutting, placing and fixing in required slope all complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender