Tender For Provision Of Certain Minor Works At 8Fbsu
Tender Value
13.07 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
4 days left
EMD
26015
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
srinagar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provision Of Certain Minor Works At 8Fbsu
BOQ
| Sl. No. | Item Description |
| 1 | B/R PORTION |
| 2 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets on any description, any thickness, including cover fillets, complete all as specified and directed by Engineer-in-Charge. |
| 3 | S&F of Elegant Tile made of perforated cement fibre composite 595x595/295 X1195/595 X1195x5mmcovered with absorptive microfiber coating on the front side and Acoustics fibre on the back side, water resistance, fire resistant absorption coefficient upto0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag and installed on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results, as in false ceiling fixed to metal frame complete all as specified and directed by Engineer-in-Charge. |
| 4 | Taking down chowkhats of frames of any description exc 1.50 Sqm but n.exc 4.00 Sqm with shutters (without taking off shutters from the frames) and making good disturbed portion complete all as specified and directed by Engineer-in-Charge. |
| 5 | S&F for Powder Coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge. Note : Shade of Powder Coating must be decided by Engineer-in-Charge. |
| 6 | S&F for Powder Coated anodised aluminium door shutters (with Sliding Mechanism), aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, with sliding arrangements, and locking mechanism, anodised aluminium snap beading screws etc. complete all as specified and directed by Engineer-in-Charge. Note: Shade of Powder Coating must be decided by Engineer-in-Charge. |
| 7 | S&F for 4.00 to 4.80mm Sheet glass, ordinary quality and glazing with oil putty in square/ rectangle in shape of any size as per site requirement in each pane fixed to aluminium framework by necessary means complete all as specified and directed by Engineer-in- Charge. Note: No extra Cost will be paid to contractor If any design/logo required over glass required after approval of Engineer-in-Charge. |
| 8 | S&F for Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-Charge. |
| 9 | S&F of 2nd class hard wood 30mm to 35mm thick, plain framed, panelled door shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, fitted to chowkats all as specified & directed. |
| 10 | S&F of 2nd class hard wood 30mm thick glazed & skeleton shutters for windows, open rebated & prepared to receive glass/ gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc size of member of shutters as specified in SSR Part-1 Sec 8 Clause 8.24(b) supplied and fitted to chowkats all as specified. |
| 11 | Supply and fixing butt hinges, (ISI Marked), medium weight, cold rolled, mild steel, of size 100mm long complete all as specified & directed by Engineer-in-Charge. |
| 12 | S&F Aluminium anodised, barrel tower bolts of size 150mm extruded section and fixed complete all as specified & directed by Engineer-in-Charge. |
| 13 | Supply and fixing in repair door seal 1.5mm thick strip of mild steel with hard brush fixed in door bottom complete all as specified and directed by Engineer-in-Charge. Note: 1. Sample must be produced prior to incorporate into the works. 2. Width of Door Seal without brush should not be less than 25mm |
| 14 | Supply and fixing floor door stopper of aluminium alloy of overall length of cover plate 140mmm and tongue, anodised, with hard drawn steel spring, fixed on door complete all as specified & directed by Engineer-in-Charge. |
| 15 | Aluminium alloy, anodised, sliding door bolt (ISI Marked) 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Preparation of new wooden surfaces of any description not otherwise described, over 10 cm width or girth and providing two coats of synthetic enamel paint over one coat of pink primer, complete all as specified & directed by Engineer-in-Charge. |
| 17 | Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer-in-Charge. |
| 18 | M&L for preparing of new or previous untreated steel surfaces over 10 cm width or girth and making good including primer and make the surface smooth by rubbing with sand papers etc and applying two coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Demolition cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level). |
| 20 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out, complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L for cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in cement concrete in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L rendering 15mm thick in cement mortar 1:4 on external fair faces of brick walls or on concrete surfaces plastered surfaces finished even and smooth without using extra cement with water proofing compound as per manufacturers instruction, complete all as specified. |
| 24 | M & L for rendering 15mm thick in cement mortar 1:6 on internal fair faces of brick walls or on concrete surfaces, finished even and smooth with using extra cement complete all as specified and as directed. |
| 25 | Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of wall care putty for making surface smooth, preparatory to distempering including preparation of surface complete, all as specified and as directed by Engr-in-Charge. |
| 26 | Preparing new plastered or un-plastered surfaces of walls and applying two coats of Acrylic exterior emulsion paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown) over a coat of acrylic primer, complete all as specified and directed. |
| 27 | Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240. |
| 28 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F for Powder coated Anodised aluminium window and ventilator shutters, Three track sliding window or fixed type as per requirement of site without sash bar, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engineer-in-Charge. |
| 31 | Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed Aluminium (extruded section). |
| 32 | Sheet glass 4.8 mm thick grounded or obscured or frosted and glazing with oil putty or fixed to timber frame in square or any shape exc 0.5 Sqm in each pane. |
| 33 | M&L for 5mm thick ACP (Aluminium Composite Panel): Two thin aluminium skins bonded to a polyethylene or fire-retardant core; highly popular for lightweight, durable, and multicolored door panels fixed with aluminium beading and rubber neoprene packing to aluminium frame, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Mortice lock, vertical type, size 100 mm, Brass 4-Levers, complete all as specified and directed by Engineer-in-Charge |
| 35 | M&L coloured/ printed non skid ceramic tiles 7 to 8 mm thick area of each tiles exc 0.18 sqm but not exc 0.38 Sqm, laid in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement, complete all as specified and directed by Engineer-in-Charge. |
| 36 | All as per item No.35 here-in-above but on vertical surfaces such as skirting including 9 to10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Reinforced cement concrete M-25 (Nominal mix) (using 20mm graded crushed stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed. |
| 38 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 39 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, complete all as specified and directed. |
| 40 | S&F in repair 20-25mm dia Stainless steel curtain rails with fixing brackets, curtain gloves, stops, rollers, funnels etc for fixing to surface of any nature using necessary arrangements, complete all as specified and directed by Engineer-in-Charge. |
| 41 | M&L hardcore using broken stone boulders not exceeding 63mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surfaces, complete all as specified & directed. |
| 42 | M&L 150 mm PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base, complete all as specified and directed. |
| 43 | M&L for rendering 10 mm thick on fair faces of concrete/ brick interior surfaces in cement mortar 1:6 as per manufacturer's instruction, finished fair and even without using extra cement, complete all as specified and directed. |
| 44 | Preparing new plastered or un-plastered surfaces of walls and applying two coats Acrylic exterior emulsion paint in camouflaging (Disruptive) pattern (Green, grey & brown colour) over a coat of acrylic primer, complete all as specified and directed. |
| 45 | Preparation of newly or plastered or un-plastered surfaces of walls and applying two coat of Acrylic washable distemper over a coat of primer after applying 3mm thick wall care putty in two layer on prepared surface, complete all as specified and directed. |
| 46 | Supply and fixing of toughened glass of 12mm as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required (toughened glass as per the design directed by Engineer-in-Charge) of comprising of the including all connecting accessories i.e. joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges etc. complete all as specified. |
| 47 | S&F anodised aluminium door shutters, aluminium section weighing 1.10 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified. |
| 48 | M&L for 12 mm prelaminated particle board both side decorative, fixed with aluminium beading and rubber neoprene packing to aluminium frame. |
| 49 | S&F 125 mm long stainless steel butt hinges medium weight with stainless steel screw complete. |
| 50 | S&F extruded aluminium alloy handles of size 125mm fabricated type anodised complete. |
| 51 | 4.8 mm thick sheet glass, ground or obscured or frosted/ tinted and glazing with oil putty or fixed with bead/glazing pins in squares of exe 0.5 Sqm in each pane, all as specified and directed. |
| 52 | M&L 2nd class soft wood clean sawn timber framed and fixed in frame work for ceiling. |
| 53 | S&F 6mm thick of plywood, grade BWP, type BB fixed with screw to mild steel frame work and No of ply 5 as in ceiling all as specified and directed by Engineer-in-Charge. |
| 54 | Preparation of new wooden surfaces of any description not otherwise described, over 10 cm width or girth and providing a coat of synthetic enamel paint over one coat of pink primer all as specified & directed. |
| 55 | Framed work as in false ceiling, doors or gates of angle or other section with gusset plates, rails, braces, etc. complete drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410 A quality grade, all as specified and directed. |
| 56 | S&F galvanised corrugated mild steel sheeting, with two corrugation side lap fixed with 'L' type or 'J' type or cranked hooked bolts with washers in roof, 0.8mm thick, grade-O quality, with 120 grms/sqm zinc coating and grade 'B' Class 8, complete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F Galvanised plain mild steel sheeting 0.8mm thickness fixed with l or J type or cranked hook bolts with washers, in roofs as in ridge etc, all as specified and directed. |
| 58 | Preparation of new or previously untreated surfaces of Steel surfaces of any description not otherwise described over 10cm width or girth and applying a coat of synthetic enamel paint over a coat of red oxide, complete all as specified |
| 59 | E/M PORTION |
| 60 | Taking down unserviceable copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc. |
| 61 | Taking down unserviceable DB any way and any type including all accessories. |
| 62 | Taking down unserviceable old aluminium service wire of any size any type all as specified and directed. |
| 63 | M&L for Flameproof point wiring with single core PVC insulated unsheathed 1100 Volt grade FRLS-694 cable with stranded copper conductor of size 1.5 Sqmm (Nominal area) drawn through and including stove enamelled steel conduit ISI marked of standard IS 9537, not less than 20mm dia, on surface as required on site and as specified and directed with all connected accessories including one single core multistranded PVC insulated, unsheathed, FRLS type, 1100 volts grade,1.5 Sqmm copper conductor cable as earth continuity cable including pressed steel terminal boxes made out of MS sheet not less than 1.2mm thick duly painted with one coat of red oxide primer with 3mm thick laminated sheet cover for mounting of switches, socket, for One light controlled by one switch, complete all as specified and as directed. |
| 64 | All same as per item No.63 above but for one 3 pin socket outlet, 16 Amp, independent with cable 2.5 Sqmm size with earth wire 2.5 Sqmm. |
| 65 | S&F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed. |
| 66 | S&F Flameproof Weatherproof Tube Light 2 x 20 Watts 4-feet made in die cast Aluminium Alloy LM6, 230 V AC , complete all as specified and directed . |
| 67 | Flameproof Weatherproof Switch Socket 16/20A 2P with 3-Pin Plug top , complete all as specified and directed. |
| 68 | Supply and fixing flat twin aluminium service cable 6 Sqmm 2 core including suitable connector block as required for proper installation and connection , complete all as specified and directed. |
| 69 | S&F in replacement Flameproof & Weatherproof MCB Distribution Board 4 Way made in die cast Aluminium Alloy LM6 consisting of :1 x 16A/25A SPN MCB as incomer2 x 6A/10A SP MCB as outgoingwith complete internal busbar and wiring upto terminals. |
| 70 | Supply and fixing GI pipes 25mm dia light grade with all fittings, laid in trenches/ fixed to walls for cable protection complete all as specified and directed. |
| 71 | M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board/panel/test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified. |
| 72 | M&L for complete point wiring for light/ fan point with 1.5 Sqmm two single core multi stranded copper conductor FRLSH insulated and unsheathed cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLSH insulated drawn in and including concealed PVC rigid conduit/ surface mounted PVC rigid conduit (as per requirement at site), ISI marked after cutting chases in wall, plastering after concealing conduit, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing, complete all as specified and as directed by Engr-in-Charge. |
| 73 | (a) One 3 Pin socket outlet point 5 Amps on the same board with other switches. |
| 74 | All as per item Srl No. 72 above but for multi 3 pin socket outlet 5 amp socket on independent board. |
| 75 | All as per item Srl No. 72 above but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/ 25 mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green color all as directed by Engr-in-Charge. |
| 76 | S&F Modular Socket, 6A-5 Pin combined 2 module, 240 Volts ISI marked, complete all as specified and directed. |
| 77 | S&F Modular switch 1 way 6A,1 module, 240 Volts ISI marked, complete all as specified and directed. |
| 78 | S&F ceiling rose, 2/3 terminal as per site requirement. |
| 79 | S&F Modular switch 1 way 16A, 2 module, 240 Volts ISI marked, complete all as specified and directed. |
| 80 | S&F Modular Socket 6A/16A - 6 pin combined 2 module, 240 Volts ISI marked, complete all as specified and directed. |
| 81 | S&F in LED lights fitting 1x 20W, 220V, AC box type complete with PVC square block-2 Nos including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 82 | M&L for distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door, complete all as directed by Engr-in-Charge.Note:- Distribution board and MCBs should be same make. |
| 83 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete along with suitable bracket and clamps for mounting. |
| 84 | M&L for Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion. |
| 85 | S&F wall mounted electric fan, 400 mm sweep, 230 V, single phase, 50 Hz, heavy duty, oscillating type, with 3-speed regulator, suitable for wall mounting, complete with mounting bracket, guard, blades, capacitor, wiring connections and all accessories, as required and directed. |
| 86 | Supply and fixing SPN 40 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 87 | S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 10-16 Amps, complete with connection testing and commissioning. |
| 88 | Supply, laying for replacement of unserviceable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured cable 16 Sqmm 2 core cable confirming to IS-7098 Part-I (1988). |
| 89 | Excavation in trenches not exceeding 1.5m in width and not exceeding 1.5m in depth and getting out in any type of soil. |
| 90 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm. |
| 91 | Removal of excavated surplus material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed. |
| 92 | Supply, laying and fixing DWC 75x63 mm (OD x ID) pipe for protection cable (orange in colour) complete with fitting and including necessary couplers, cutting, jointing and clamping, complete all as specified and as directed. |
| 93 | Labour for cutting of bituminous/concrete road not less than 30cm depth & width for passing underground cable through road, and making good the disturbed surfaces with PCC/Bitumen Tack coat, to match with the existing surface, complete all as specified and directed. |
| 94 | M&L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 04 Sqmm and drawing through & including Non metallic PVC casing caping on walls/ceiling including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in concealed PVC casing caping including connecting to main board, complete all as specified and directed by Engineer-in-Charge. |
| 95 | S&F MCB Distribution board, Single pole & neutral 240 Volt, 8 way, type With 200 Amps bus bar, complete all as specified and directed. |
| 96 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 97 | (a) SP 5 To 32 AMP |
| 98 | (b) SPN 40 to 63 AMP |
| 99 | Supply and fixing 36 Watts recess /surface mounting LED flat panel 2' X 2' made of extruded aluminium frame with high LEDs & glare free opal diffuser IP20, all as required at site and as specified and directed by Engineer-in-Charge. |
| 100 | Taking down existing TPN/SPN DB and electric Energy meter of any size with due care and refixing with new lock bolt (where required) after cleaning/painting if required including connecting electrically using cables as required at site all as specified and directed by Engineer-in-Charge. |
| 101 | S&F Dehumidifier for coverage area of upto 180 Sqft having draining capacity of 12 litres per day and tank capacity 2.6 litres, power consumption 210 Watt auto resume silent operation programmable timer, complete all as specified and as directed. |
| 102 | Note:- An amount of Rs.3690.00 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender