Tender For General-Pookaitha Kadavu-Investigation For Construction Of Side Protection And Pavilion On Right Bank Of Kanheeramukku River At Kadavanad Pookaithakkadavu In Ponnani Municipality, Malappuram District.-Investigation Work
Tender Overview
Project Description
Tender for General-Pookaitha Kadavu-Investigation For Construction Of Side Protection And Pavilion On Right Bank Of Kanheeramukku River At Kadavanad Pookaithakkadavu In Ponnani Municipality, Malappuram District.-Investigation Work
BOQ
| Sl. No. | Item Description |
| 1 | Investigation work |
| 2 | 56.1.a:Mobilization including transportation of all necessary plant and equipment's and materials of boring, field testing and sampling and demobilization after completing the work - For machine boring |
| 3 | 56.9.1:Erecting platform over 2 nos of 2nd Class Boat using Mango wood planks of not less than 30 mm thick, Mango wood joists of 100 mm x 70 mm at 60 cm intervals including labour and hire of all materials and dismantling the platform after completion of work etc complete. excluding hire of boats (A Platform of minimum size 6.00 m x 5.00 m will be required) |
| 4 | 56.10:Hire charges for providing 2 nos of 2nd Class boat with boatman for erecting the platform over which the boring plant is to be erected, and 1 no of 2nd Class boat with 1 boatman for conveying the departmental staff and labour engaged from the banks to platform and back etc. |
| 5 | 56.2.a:Setting up boring at each bore hole locations including carrying all necessary plant, equipment and materials of boring and field tests and collection of samples at each bore hole location - For machine boring. |
| 6 | 56.3.a.2:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata upto 10m including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For under water. |
| 7 | 56.3.b.2:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata next 10m and upto a depth of 20m including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For under water. |
| 8 | 56.3.c.2:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata next 10m and upto a depth of 30m including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For under water. |
| 9 | 56.3.d.2:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata above 30m depth including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For under water. |
| 10 | 56.4:Boring through all type of hard rock or similar refusal strata of N value greater than 50 using diamond core drilling bit for in land under water and banks of river. |
| 11 | 56.8:Recovering disturbed samples and preserving the same in air tight sample containers including waxing labelling packing storing including cost of containers as per IS Code. |
| 12 | 56.11.a:Compilation of all field data with recommendation for a suitable foundation after conducting necessary lab test (report in triplicate) - Machine boring for 5 bore holes. |
| 13 | OD16007/2026-2027:Preparation of Detailed Project Report of the Pavlion and side protection works containing alignment plan, key plan, contour plan ,index map, longitudinal and cross sections of road and River cross sections, hydraulic and velocity calculations including structural design from accredited agency including neat filing and supplying five set DPR etc. as per the directions of the departmental officers. |
| 14 | surveying |
| 15 | 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 16 | 60.11.2:Taking FLY LEVELS- from the nearest GTS BM and closing on the starting BM including conveyance of instruments etc along road or in heavily built up area or in roads with heavy traffic or in thick jungle ( out turn 4000 m / day ) |
| 17 | OD14777/2026-2027:Conducting topographic survey in banks of river for taking cross sections at suitableintervals and preparing contour maps showing 2 m interval contours using TotalStation or such approved methods showing all topographic features like culverts andcrossings, survey stones and other permanent objects and the preparation andsubmission of maps at suitable scale (plan, cross sections, longitudinal sections etc),indicating the contour lines 2m interval in digitized forms including supplying 5numbers of soft copies CD/DVD, 5 numbers of hard copies of print outs etc completeas per the direction of departmental officers at site (outturn 3 hect/day) |
| 18 | OD14782/2026-2027:Conducting topographic survey in river for taking cross sections at suitable intervalsand preparing contour maps showing 2 m interval contours using Total Station or suchapproved methods showing all topographic features like culverts and crossings, surveystones and other permanent objects and the preparation and submission of maps atsuitable scale (plan, cross sections, longitudinal sections etc), indicating the contourlines 2m interval in digitized forms including supplying 5 numbers of soft copiesCD/DVD, 5 numbers of hard copies of print outs etc complete as per the direction ofdepartmental officers at site (outturn 6 hect/day) |
| 19 | 60.11.1:FIXING TBM- Supplying and fixing TBM with RCC 1:1.5:3 pillar block having a size of 30*30*75 cm, steel reinforcement for RCC work, painting top and sides of pillar with synthetic enamel paint, lettering in the pillar block with 8cm high \\"TBM\\" on one face and the reduced level on the outer face, etc complete, fixed in CC1:3:6 using 40 mm metal 55*55*60 cm etc complete and centering and shuttering including strutting , propping and removal of form work for pillar and foundation. |
| 20 | OD15045/2026-2027:Supplying and fixing boundary stone with RCC 1:1.5:3 pillar block having a size of30*30*75 cm, steel reinforcement for RCC work, etc complete, fixed in CC1:3:6 using40 mm metal 55*55*60 m etc complete and centering and shuttering includingstrutting , propping and removal of form work for pillar and foundation. |
| 21 | OD16422/2026-2027:Engaging chainmen to assist surveyors for surveying departmental land including all charges complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender