Bids Are invited for Operation And Maintenance Of Electro-Mechanical Installations - Complete System - Job Contract For Round The Clock Operation And Maintenance Of Complete Electrical & Mechanical Out Door/Indoor Installations Of 33Kv Substation Com
Tender Overview
Project Description
Bids Are invited for Operation And Maintenance Of Electro-Mechanical Installations - Complete System - Job Contract For Round The Clock Operation And Maintenance Of Complete Electrical & Mechanical Out Door/Indoor Installations Of 33Kv Substation Comprises Switch Yard, Ht & Lt Breakers, Transformers And Associated Switchgears, Dg Sets, Lt & Mv Panels, Pumps Of Colony And Service Block, All City Side Installation Including Old Terminal Building, Offices, Street Lights, Water Pumping System, Internal & External Lighting And Power Supply System, Maintenance Of E&M Installations Of Residential Colony, Cisf Barrack Etc. At S.V. Airport Including Preventive Maintenance, Break Down And Corrective Maintenance With Min. Man Power As Per The Special Conditions Of Contract , Detailed Scope Of Work And Aai Requirement On All Days Including Sundays And Holidays Etc. Complete As Required. , Overhauling Of Complete Water Softening /Treatment Plant Consist Of The Multigrade Sand Filter, Dual Media Filter With Multigrade Quartz Sand And Anthracite (Capacity : 27600 Lph, Filtration : 18-20 Cum/Sqm/Hrs.) And Water Softener Having Media For Softener With Cation Exchange Resin, Brine Tank. (Inlet : Up To 400 Ppm, Outlet : Commercial Zero (<5Ppm)) Capacity : 13200 Lph) And Other Associated Accessories Available As Per Site Requirement.(A) Resin For Softener -1100X2= 2200Ltr.(B) Sand 600X2= 1200Kg.(C) Activated Carbon - 300X2= 600Kg.(D) Rubber Gasket - 2 X 2= 4 Nos.(E) Hardware Nut Bolt Complete Set 1X2=2 No.(F) Salt -200Kg(G) Chlorine-100Ltr. , Servicing Of Following 33 Kv / 0.433 Kv Sf6/Vcbs And Ht Panel Through Oem/Its Authorized Dealer By Cleaning, Checking, Tightening, Adjusting, Replacing Defective Components, Aligning ,Lubrication, Greasing And Complete Health Check Of Control Wiring Of Ht Panel Etc Complete As Required Without Spare Parts. , 1St Year , 2Nd Year , Servicing Of 630 Amps-2500 Amps Mv Air Circuit Breaker Through Oem/Its Authorized Dealer By Cleaning, Checking, Tightening, Adjusting, Replacing Defective Components, Aligning ,Lubrication, Greasing And Complete Health Check Of Control Wiring Of Lt Panel Etc Complete As Required Without Spare Parts Including Over Load, Earth Fault, Short Circuit & Megger Testing Through Secondary Injection Kit Etc Complete As Required. , 1St Year , 2Nd Year , Testing, Calibration And Recommissioning Of Following Existing Protective Relays Fitted In The 33 Kv Cubicle Panels By Using Secondary And Primary Injection Kit Including Submission Of Test Report Etc., As Required. , 1St Year , 2Nd Year , Testing, Calibration And Recommissioning Of Following Existing Protective Relays Fitted In The 415 V Cubicle Panels By Using Secondary And Primary Injection Kit Including Submission Of Test Report Etc., As Required. 1St Year , Testing, Calibration And Recommissioning Of Following Existing Protective Relays Fitted In The 415 V Cubicle Panels By Using Secondary And Primary Injection Kit Including Submission Of Test Report Etc., As Required. 2Nd Year , Inspection, Testing, Adjusting, Preventive Maintenance Of 33/0.433 Kv, 1600 Kva Voltamp Make Oil Cooled Transformer To Assess The Overall Healthiness Of The Transformer I/C Overhauling Of Oltc, Checking, Adjusting Of Rtcc And Submission Of Reports Etc. Complete As Required. Dehydration/Filtration Of Transformer Oil To Attain Acceptable Di-Electric Strength By Hot Streamline Process For The Oil Cooled Transformers, Voltage Regulators/Stabilizers Including Transportation Of Equipment, Trial Of Tap Changer Electrical And Mechanical Operation, Refilling Of Transformer Oil, Oltc To Converter Level Submission Of Test Reports Etc. As Required. (Tentative Qty. Of Each Transformer 1955 Ltrs.) As Required. Supply & Top Up Of Transformer Oil For Transformer, Voltage Regulator/Oltc/Stabilizers As Required. , Supply Of New Transformer Oil For Transformer, Oltc As Required Having Relevant Is Standard. , Supply & Replacement Of Silica Gel Breather For Voltamp Make 33/0.433Kv, 1600 Kva Transformers. ( Each Tr 1.5Kg) , Supply Of Following Spares For The Oltcs Of 33/0.433 Kv, 1600 Kva Transformers, As Per Requirement. A) Supply Of Fixed Contact -10.00B) Supply Of Main Moving Contacts-3.00C) Supply Of Top/Bottom Cover Gasket-3.00D) Supply Of Transition Resistance-3.00E) Supply Of Silica Gel Breather-3.00F) Supply Of Gasket Sheet(6 Mm Thickness, 915Mm Length)-3.00G) Supply Of Oil Seal For Mechanism Centre Shaft-3.00 , Servicing & Health Checking Of Programmable Logic Controllers Of Make Allen Bradley, Of Dg Amf/Synchronized Panel Distridution Panel, Mv Panel For Its Electrical Operation, And Submission Of Test Report Etc.As Per Site Requirment. , Servicing & Health Checking Of Programmable Logic Controllers Of Make Schneider Electric Model No.Tm200c40t, Dg Set Lt Panel Electrical Operation, Submission Of Test Report Etc.As Per Site Requirment.
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender