Tender For Periodical Maintenance / Servicing And Replacement Of Accessories Of Chs Plants Incluing Glycol Circulation Pumps, Motors, Plants Valves Alongwith Connected Accessories At Sector C Under Age E/M-I Of Ge 865 Ews
Tender Overview
Project Description
Tender For Periodical Maintenance / Servicing And Replacement Of Accessories Of Chs Plants Incluing Glycol Circulation Pumps, Motors, Plants Valves Alongwith Connected Accessories At Sector C Under Age E/M-I Of Ge 865 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Attending complaints with T&P for preventive maintenance by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required without any damage, heating up the freezed glycol line anywhere about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engineer-in- Charge all as directed (One skilled and one helper to carry out appropriate repair as desired by user at site.Note : Flap motor and display circuit required will be measured under respective item. |
| 2 | Supply only flap motor compitable for FCU of capapcity upto 3000 to 4000 K Cal/Hr |
| 3 | Supply only display circuit compitable for FCU of capapcity upto 3000 to 4000 Lakh K Cal/Hr. |
| 4 | Dismantling of burner assembly of CHS and removing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 6.00 lakh kilo/cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, complete all as specified and/or directed by Engr-in Charge.Note :- New sequence controller, ignition rod, ignition transformer,temp controller, photo cell electrode, burner nozzle, hooter and bridge rectifier shall be measured and paid under respective item. |
| 5 | All as per item No.2 but for 3.00 to 4.00 Lakh Kilo/cal/Hr. |
| 6 | All as per item No.2 but for 0.5-2 Lakh Kilo/cal/Hr. |
| 7 | S&F in replacement of sequence controller as per existing model suitable for burner of capacity 6.0 lakh kilo/hr. |
| 8 | S&F in replacement of sequence controller as per existing model suitable for burner of capacity 3.0 to 4.0 lakh kilo/hr. |
| 9 | S&F in replacement of sequence controller as per existing model suitable for burner of capacity 0.5 to 2.0 lakh kilo/hr. |
| 10 | S&F in replacement of ignition rod as per existing model suitable for burner of capacity 6.00 lakh kilo/Cal/hr. |
| 11 | S&F in replacement of ignition rod as per existing model suitable for burner of capacity 3.0 to 4.0 lakh kilo/Cal/hr. |
| 12 | S&F in replacement of ignition rod as per existing model suitable for burner of capacity 0.5-2 lakh kilo/Cal/hr. |
| 13 | S&F in replacement of ignition Transformer as per existing model electronic type suitable for burner of capacity 6.00 lakh kilo/Cal/hr. |
| 14 | S&F in replacement of ignition Transformer as per existing model electronic type suitable for burner of capacity 3.0 to 4.0 lakh kilo/Cal/hr. |
| 15 | S&F in replacement of ignition Transformer as per existing model electronic type suitable for burner of capacity 0.5-2 lakh kilo/Cal/hr. |
| 16 | S&F in replacement of temp controller digital type DTC 503 with sensor as per existing model suitable for burner of capacity 6.00 lakh kilo/Cal/hr. |
| 17 | S&F in replacement of temp controller digital type DTC 503 with sensor as per existing model suitable for burner of capacity 3.0 to 4.0 lakh kilo/Cal/hr. |
| 18 | S&F in replacement of temp controller digital type DTC 503 with sensor as per existing model suitable for burner of capacity 0.5-2 lakh kilo/Cal/hr. |
| 19 | S&F in replacement of photo cell as per existing model suitable for burner of capacity 6.00 lakh kilo/Cal/hr. |
| 20 | S&F in replacement of photo cell as per existing model suitable for burner of capacity 3.0 to 4.0 lakh kilo/Cal/hr. |
| 21 | S&F in replacement of photo cell as per existing model suitable for burner of capacity 0.5-2 lakh kilo/Cal/hr. |
| 22 | S&F in replacement of burner nozzle as per existing model suitable for burner of capacity 6.00 lakh K/Cal/Hr |
| 23 | S&F in replacement of burner nozzle as per existing model suitable for burner of capacity 3.0 to 4.0 lakh K/Cal/Hr |
| 24 | S&F in replacement of burner nozzle as per existing model suitable for burner of capacity 0.5-2 lakh K/Cal/Hr |
| 25 | S&F in replacement of Electrode as per existing model suitable for burner of capacity 6.00 lakh K/Cal/Hr |
| 26 | S&F in replacement of Electrode as per existing model suitable for burner of capacity 3.0 to 4.0 lakh K/Cal/Hr |
| 27 | S&F in replacement of Electrode as per existing model suitable for burner of capacity 0.5-2 lakh K/Cal/Hr |
| 28 | S&F in replacement of Bridge rectifier as per existing model suitable for burner of capacity 6.00 lakh K/Cal/hr. |
| 29 | S&F in replacement of Bridge rectifier as per existing model suitable for burner of capacity 3.0 to 4.0 lakh K/Cal/hr. |
| 30 | S&F in replacement of Bridge rectifier as per existing model suitable for burner of capacity 0.5-2 lakh K/Cal/hr. |
| 31 | S&F in replacement of Thermostat assembly tail type as per existing model suitable for 0-30 degree centrigrade temprature. |
| 32 | S & F in replacement of hooter round type as per existing model complete all as specified and/or directed by Engineer-in-Charge. |
| 33 | S&F in replacement of pressure gauage 0 to 20 Kg/sqm sq as per existing model, complete all as specified and/or directed by Engineer-in-Charge. |
| 34 | S&F closed cell elastometric insulation 30 to 40 Kg/Cum density, 25 mm thick (nitrile insulation) complete all as specified and/or directed by Engineer-in-Charge. Make- Eurobatex/ Superion/ Aeorflex. |
| 35 | S&F in replacement oil pressure pump 7276-3D67A complete all as specified and/or directed by Engineer-in-Charge. Make- Suntec or equivalent from approved makes. |
| 36 | S&F in replacement of Fuel filter 1/2 ltr,complete all as specified and/or directed by Engineer-in-Charge. Make- Kirloskar/Mico/TVS. |
| 37 | M&L for repair of MS exhaust pipe of dia upto 150mm of CHS plant by welding and painting silver paint over one coat of red oxide complete all as specified and/or directed by Engineer-in-Charge. |
| 38 | S&F in replacement of auto air pressure valve 3/8\\" as per existing, complete all as specified and/or directed by Engineer-in-Charge. |
| 39 | S&F in replacement of High pressure fuel pipe 1.5 mtr length as per existing, complete all as specified and/or directed by Engineer-in-Charge. |
| 40 | Taking down unserviceable burner set of capacity 6.00 Lac K Cal/Hr heating plant and removing all unserviceable parts like diffuser, nozzle, electrodes, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller and supply and fix diffuser, nozzle, electrodes, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller as per existing model re-assembling and testing on completion complete all as specified and directed. |
| 41 | Taking down unserviceable burner set of capacity 0.5-2.0 Lac K Cal/Hr heating plant and removing all unserviceable parts like diffuser, nozzle, electrodes, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller and supply and fix diffuser, nozzle, electrodes, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller as per existing model re-assembling and testing on completion complete all as specified and directed. |
| 42 | Taking down unserviceable burner set of capacity 3.0 to 4.0 Lac K Cal/Hr heating plant and removing all unserviceable parts like diffuser, nozzle, electrodes, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller and supply and fix diffuser, nozzle, electrodes, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, flame detector and controller as per existing model re-assembling and testing on completion complete all as specified and directed. |
| 43 | S&F in replacement of FCU connection of copper pipe 20/16 mm with check nut at both side as per required length/ existing complete all as specified and/or directed by Engineer-in-Charge. |
| 44 | S&F in replacement of FCU connection flexible pipe 20/16 mm as per existing, complete all as specified and/or directed by Engineer-in-Charge. |
| 45 | Material and labour for electronic control wiring of FCU of any size and making the display functional, including dismantling existing u/s wiring completely all as specified and/or directed by Engineer-in-Charge. |
| 46 | S&F in replacement of plug top 15 Amps as per existing, complete all as specified and/or directed by Engineer-in-Charge. |
| 47 | S&F in replacement of needle valve 3/8\\" British Standard Ppipe as per existing, complete all as specified and/or directed by Engineer-in-Charge. |
| 48 | S&F in temp controller regulator type as per existing model complete all as specified and/or directed by Engineer-in-Charge. Make- Subzero or equivalent from approved makes. |
| 49 | S&F in replacement of inlet outlet Ball valve 3/4\\" for FCU as per existing, alongwith MS / GI nipple of size 3/4 inch includig welding work, cutting the existing rusty unserviceable MS/GI nipple complete all as specified and/or directed by Engineer-in-Charge. |
| 50 | S&F Inlet/outlet ball copper valves set of 1/4\\", complete all as specified and/or directed by Engineer-in-Charge. Make- Rapid Cool/Sant or equivalent from approved makes. |
| 51 | S&F Pipe fitting of brass(Nipple outer thread) 1/4\\" size, complete all as specified and/or directed by Engineer-in-Charge. |
| 52 | S & F in replacement of ring clip of flexible PVC pipe of existing size complete all as specified and/or directed by Engineer-in-Charge. |
| 53 | S&F in replacement of Chilled / Hot water wall mounting indoor type Fan Coil unit 6000 Lakh K Cal / Hrs capacity incl 02 Nos of 20 mm Valve with stainer (inlet & outlet ) including heavy duty PVC Pipe for connection complete all as specified and directed by Engr-in -charge.Make Carrier or approved equivalent make. |
| 54 | Supply onlying and replacement of Chilled / Hot water wall mounting indoor type Fan Coil Unit (FCU) 4500 Lakh K Cal / Hrs capacity incl 02 Nos of 20 mm Valve with stainer (inlet & outlet ) including heavy duty PVC Pipe for connection complete all as specified and directed by Engr-in -charge.Make Carrier or approved equivalent make. |
| 55 | Supply onlying and replacement of Chilled / Hot water wall mounting indoor type Fan Coil Unit (FCU) 3000 K Cal / Hrs capacity incl 02 Nos of 20 mm Valve with stainer (inlet & outlet ) including heavy duty PVC Pipe for connection complete all as specified and directednby Engr-in -charge.Make Carrier or approved equivalent make. Please Enable Macros to View BoQ information |
| 56 | Supply onlying and replacement of Chilled / Hot water wall mounting indoor type Fan Coil Unit (FCU) 3000 K Cal / Hrs capacity incl 02 Nos of 20 mm Valve with stainer (inlet & outlet ) including heavy duty PVC Pipe for connection complete all as specified and directednby Engr-in -charge.Make Carrier or approved equivalent make. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender