Tender For Special Repair To Otm Bldg No P-338 (Living Accn) Of 18 Cav
Tender Value
24.22 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
1 days left
EMD
48500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmedabad → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Otm Bldg No P-338 (Living Accn) Of 18 Cav
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (ARMY) AHMEDABAD NAME OF WORK : SPECIAL REPAIR TO OTM BLDG NO P-338 (LIVING ACCN) OF 18 CAV CONTRACT AGREEMENT: GE (A)/ABD/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. |
| 3 | Demolition of cement concrete of any description and in any position not otherwise as dircetd and as specified. |
| 4 | Demolition of Reinforced Cement concrete of any description and in any position not otherwise specifically provided all as directed. |
| 5 | M&L for 25 mm thick PCC type B-0 (1:2:4) using 12.5 mm aggreage as in floor finished even and rough to received top layer or tiling complete all as specified. |
| 6 | M & L for non skid ceramic (colored), 7 to 8 mm thick as in floor area of each tile exceeding 0.6 Sqm but n exceeding 0 .11 Sqm , set and jointed in neat cement slurry and pointed in white or colored cement to match incl and over screed bed or beeding layers of mortar 15mm thick in CM 1:4 in floors, complete all as specified and directed. complete all as specified and directed. |
| 7 | M&L for Glazed ceramic tiles coloured (300x450mm) x 7mm thick, in wall/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick backing coat of tiles in CM (1:3) complete all as specified |
| 8 | M&L for Vitrified Ceramic tiles light shade 10 mm, (square or rectangular) area of each tile n. exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed CM 1:4 complete all as specified and directed. |
| 9 | All as per item No 7 above but on vertical surfaces incl 10mm thick backing coat of tiles in CM (1:3) complete all as specified |
| 10 | M&L machine cut Kota stone slab 20-25 mm thick as in flooring or trades of step incl half round moulding over and including screed bed 20 mm thick in CM (1:3) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified. |
| 11 | M&L Udaipur Green marble 18-20 mm thick laid and jointed with grey cement slurry over and including 20 mm thick CM 1:3 screed bed complete all as specified and directed.(Note: All exposed side of stone slab to be rounding) |
| 12 | Removing of existing unserviceable water proofing treatment with PCC padding, taking down cement plaster etc of any description and cleaning of top surfaces of cement concrete flushing out junction of parapet walls and washing down with water complete all as specified and directed. |
| 13 | M&L for water proofing treatment to non assessible RCC roofs by providing 10mm thick screed in CM 1:3 mixed with water proofing compound @3% by weight of cement & applying one coat of bitumenous primer @ 0.30 kg/sqm & laying APP based polymeric modifed membrane with polyster non woven reinforced of weight not less than 3kg/Sqm of 3 mm thick with polythene finished sealing with side overlaps of 75mm & 100 mm laps at the ends of membrane by torch application method & applying two coats of aluminium paint 0.2 litre /sqm as per the makes approved by the Engr-in-Charge. Note: WPC shall be measured and paid sepratly |
| 14 | Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed |
| 15 | Dismantling water tanks and removing to store exceeding 500 ltrs and n exc 1000 ltrs complete all as specified and directed. |
| 16 | S & F 1000 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed |
| 17 | M&L for PCC (1:3:6) Type C-2 with using 40mm graded stone aggregates as in platform for PVC tank all complete as specified and as directed. |
| 18 | S&F 20 mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut. |
| 19 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc 10 cm girth complete all as specified and directed |
| 20 | Taking up or down GI tubing 15mm bore pipe and connection including cleaning for refixing or removal from site as directed |
| 21 | S&F 15mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed. |
| 22 | Taking up or down GI tubing 20mm bore pipe and connection including cleaning for refixing or removal from site as directed |
| 23 | S&F 20mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed. |
| 24 | Taking down cement plaster on wall of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 25 | M&L for rendering on fair faces of brick work 15 mm thick in CM 1:4 mixed finishing the surface fair and even without using extra cement complete all as specified and as directed. |
| 26 | S&F Butt hinges, Medium weight, cold rolled mild steel, and fixed 100mm size complete all as specified and directed. |
| 27 | M&L for PCC 1:2:4 type B0 using 12.50mm graded stone aggregate in roof etc. as levelling coarse etc.complete all as specified and directed. |
| 28 | M&L 15mm thick rendering in cement mortar 1:6 on other than fair face of brick work or concrete surface complete all as specified and directed. |
| 29 | M&L newly plastered or un plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying one coat cement based wall putty to wall surface complete all as specified and directed. |
| 30 | Complete removal of existing treatment of old plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying one coat cement based wall putty to wall surface complete all as specified and directed. |
| 31 | M&L for rendering 5mm thick plastering in CM (1:3) on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement complete all as specified and directed. |
| 32 | M&L preparing newly plastered or unplastered surface of ceiling and applying three coats of white washing complete all as specified and directed. |
| 33 | M&L complete removal of existing treatment of ceiling and applying three coats of white washing complete all as specified and directed. |
| 34 | Demolition of brick work built in cement mortar of any description complete all as specified and directed. |
| 35 | M&L brickwork with sub class B bricks straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6 by using old size bricks complete all as specified and directed. |
| 36 | M&L guniting for shortcrete 1 :2 (CM) mixed with epoxy resin and hardner (manufactured by FOSROC/MC BAUCHEMIC /CICO/PIDILITE)@ 2% by weight of cement in equal proportion using short crete pumps and allied equipment,in thickness 30 mm all as per manufactureres instruction.(Upto 5 mtr height) including necessary chiping/taking down loose concrete along with application of rust remover for old rusted bars and rebar if required followed by application of anti corrosive paint over old /rebar as per manufacturers instruction complete all as specified and directed directed. |
| 37 | S& F mild steel welded fabric of weight exe 2.5 Kg but n.exc. 4 Kg/ Sqm, fixed to steel members with spikes complete all as specified. |
| 38 | S&F in repairs vitreous china wash basin, white, flat back, size 550x400m excluding taps, waste , chain & plug & porcelain stopper including brackets incl cutting for pinning in ends of bracketes or erecting stand and fixing and supply and waste pipe complete all as specified and directed |
| 39 | Supply of 600mm x 450 mm bevelled edge mirror of selected quality, mounted on 6 mm thick AC plain building board or commercial plywood and fixed to wall on wooden plugs with chromium plated brass screws and cup washers all complete as specified and as directed. |
| 40 | S&F in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length complete all as specified and directed. |
| 41 | S&F in repair vitreous china wash down water closet pan (pedestral pattern), white including connection trap and to flushing pipe, anti-syphnoge pipe etc complete including complete all as specified and directed. |
| 42 | S&F in repair vitreous china squatting pan Orissa pattern size 580x440mm white with integral foot rest complete incl provision of lime concrete bedding. |
| 43 | S&F in repair 15 mm bore angle cock with flage complete all as specified and direcrted |
| 44 | S&F in repair CP towel rail 600 mm D type complete all as specified and directed. |
| 45 | S & F in repairs chromium plated soap dish complete all as specified |
| 46 | S&F in repair health faucet(ABS Body) mild steel chromuim plated suitable fo 15 mm dia pipie with 1.25 m long flexible tube and ABS wall hook incl making connections and fixed in position complete all as specified and directed. |
| 47 | S&F in repairs Bib taps (long body )fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule all complete as specified and as dierected. |
| 48 | S & F in repair 15mm bore PVC Connection with PTMT nut of length 450 mm complete all as specified and directed |
| 49 | S&F pillar taps, cast copper alloy with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore. |
| 50 | S&F in repair brass CP shower rose 125 mm size with or without swivel joint and fixing to steel pipe complete all as specified and directed. |
| 51 | S&F in repairs stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type) for 15mm bore pipe, screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed. . |
| 52 | S & F in repair Grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40gms) complete all as specified and directed. |
| 53 | Supply of sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 54 | Dismaintling of 75mm to 100mm bore cast iron pipe /PVC jointed in cement mortar and taking out of trenches or any description and any position as required complete all as specified and directed. |
| 55 | S&F 100mm bore cast iron soil , waste and vent pipe, sand cast, in any length , with or without ears , with cement joints in cement sand mortar 1:1 with spun yarn fixed to wall complete all as specified and directed. |
| 56 | S & F cast iron soil, waste and vent pipe, sand cast 75mm bore in any length, with or without ears, with cement joints in CM 1:1 with spun yarn fixed to over septic tank or soakage well complete all as specified and directed |
| 57 | S&F of 100 mm bore cast iron bend/TEE (any Radius) diminishing pieces or tapers (Large bore measured) complete all as specifed and directed. |
| 58 | S&F of 100 mm bore cast iron branch pipe , single (equal or unequal), ordinary or inverted (Spigot or Socket type ) or with parallel branches complete all as specified and directed. |
| 59 | S&F of 75 mm bore cast iron bend (any Radius) diminishing pieces or tapers (Large bore measured) complete all as specifed and directed. |
| 60 | S&F of 75 mm bore cast iron cast iron cowls complete all as specifed and directed. |
| 61 | Taking down chowkat with shutter exc 1.5 sqm and n. exc. 4.00sqm each and removing from site. |
| 62 | Taking down chowkat with shutter n. exc. 1.5sqm each (without taking off shutter from the Frame). |
| 63 | S&F mild steel angle iron work as in doors frames, door gate chajja hollow square sections conforming to 410W(Gde E-250) quality-B including fixing of holdfast and hinges complete all as specified |
| 64 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE and having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified specified |
| 65 | S&F factory made 30 mm flush shutter, solid coare construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified and directed. |
| 66 | S&F factory made 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash members, any numbers and mited beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20(a) supplied and fitted to chowkats |
| 67 | S & F stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and directed |
| 68 | S&F 200 mm long Aluminium anodised barrel tower bolts complete all as specified and directed. |
| 69 | S&F 150 mm size aluminium anodised door handles complete all as specified and directed. |
| 70 | M&L for sliding door bolt of 300mm long plate Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 71 | S&F 300 mm ordinary mild steel rat tail rod pattern spring incl roller and roller plate complete all as specified and directed |
| 72 | M&L for preparation of new wooden surface of any description n. exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer. |
| 73 | S&F Factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. |
| 74 | S&F Solid PVC door frame of size 50x47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplied and fixed in repair in opening as per specification and drawing complete as directed. |
| 75 | S&F stainless steel butt hinges medium weight 100 mm long complete all as specified and directed |
| 76 | S&F 125 mm long Aluminium anodised barrel tower bolts complete all as specified and directed. |
| 77 | S & F powder coated anodised Aluminium alloy sections sliding windows with frames Series-B (18 mm) and , 3 track sliding shutters duly fitted with neoprene beading, glazing clips, two shutters tinted glass panes 4.80 mm nominal thickness one shutter with stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed.Note :Rates include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle with or without opeing for AC. |
| 78 | S & F powder coated anodised Aluminium aloy sections windows with frames Series-B (18 mm), side Hung shutters duly fitted with neoprene beading, glazing clips, shutters with tinted glass panes 4.80 mm nominal thickness and having shutter with stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed. |
| 79 | S&F aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified. |
| 80 | S & F of mild steel work such as window guard bars and similar work conforming to Fe – 290 Grade – E 165 complete all as specified and directed. |
| 81 | S&F in repair stainless steel 25 mm dia drapery rod fancy type fixed to wall with bracket & knobs complete. |
| 82 | M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 83 | M&L 75mm thick PCC (1:3:6) type C2 as in plinth protection/footpath using 40mm graded stone aggregate finishing cement concrete surface even & smooth without using extra cement including impression and glass strip or bitumen filling in two panel etc complete all as specified and as directed. |
| 84 | M&L for pre Polished Chequered cement concrete tiles 30cm x 30cm x25mm thick on horizontal surfaces,set, jointed and pointed in neat cement slurry in floors incl 15mm thick screed bed CM 1:6 all as Specified. |
| 85 | S&F 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed |
| 86 | S&F of 75 mm bore cast iron branch pipe , single (equal or unequal), ordinary or inverted (Spigot or Socket type ) or with parallel branches complete alla specied and directed. |
| 87 | S & F Cast iron floor trap, 100 mm outer dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 88 | S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 89 | S &F 110 mm PVC (SWR) bends any radius complete all as specified and directed. |
| 90 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 91 | Complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 92 | Taking down copper/aluminium point wiring ( light, socket or power) complete,incl fixtures and fittings like switches, ceiling rose, pendant, regulator, sockets, light fitting ( Mirror light,Bulk head,LED Panel 2''x2'',security light,wall fitting,down light, Flood light,post top lantern) etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. |
| 93 | M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for the following points:-One light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 94 | M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for the following points:-One 6A socket point controlled by one switch on independent board |
| 95 | M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for the following points:-One 6A socket point controlled by one switch on same board |
| 96 | All as per item No. 94.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 97 | Taking down carefully aluminum or copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete. |
| 98 | M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length) |
| 99 | M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length) |
| 100 | Notes for item No. 91.00 to 98-00: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion. |
| 101 | Supply and fix in replacement of Modular switch 1 way 6A, 1 module 240V, 50Hz complete all as approved. |
| 102 | Supply and fix in replacement of Modular switch 1 way 16A, 1 module 240V, 50Hz complete all as approved. |
| 103 | Supply and fix in replacement of Modular Socket, 6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specifed and directed. |
| 104 | Supply and fix in replacement of Modular Socket 6A/16A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed. |
| 105 | Supply and fix in replacement of ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed. |
| 106 | Supply and fix in replacement of modular fan regulator step type 240V, 50Hz, compatible for BLDC fan complete all as specified and directed. |
| 107 | Supply and fix in replacement of old unserviceable LED tube light fitting Integral slim LED batten 20 watts with polycarbonate housing and diffuser internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified. |
| 108 | Supply and fix in replacement of old unserviceable LED mirror light light fitting Integral slim LED batten Integral 9 / 10 watts of 2 feet long internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 109 | Taking down existing old ceiling / exhaust fan of any size carefully, sealing cable end, dismantling blades and removing fan and blades and deposited to AGE E/M store yard complete all as specified and directed |
| 110 | S&F in replacement of old ceiling fans complete with blades, down rods, and accessories, 230V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 111 | Supply and fixing of Exhaust Fan AC single phase 230Volt of size 300 mm sweep, 900 RPM turbo force energy efficient exhaust fan for kitchen (Metallic body finish) including making circular hole in wall of suitable size and grouting fastener with nut & washer-04 nos for installation of exhaust fan including providing the electrical connection with PVC insulated and PVC sheathed copper flexible cable of size 1.0 sqmm 3 core up to the ceiling rose complete all as specified and as directed. |
| 112 | Supply & fix Wall fans 400mm sweep with plastic fiber body, and web mesh guard, 230V AC, single phase, oscillating type complete and fixing the fan to wall including making electrical connection with ceiling rose including taking down existing unserviceable wall fan of any description complete all as specified and directed. |
| 113 | Supply and fix in replacement of LED street/security light fitting 30 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 40mm dia medium grade GI pipe of length 1.00m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified.Make: Havells Cat No: LHETAVU7PA7J030 or equivalent in make of Bajaj/ Wipro/ Philips. |
| 114 | Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface all as specified.Make: Havells Cat No: DHDMCSN0251025 or equivalent in L&T/ Simens/ Legrand. |
| 115 | Supply and fixing in replacement of electric water heater, storage type steel body with glass lined inner tank and heating element up to 3KW capacity 100 litre,BEE 3 star rated complete with all accessories such as safety valve, thermostate, NRV, flexi connection pipes etc including all water connection and fixing on wall with suitable MS tower/anchor bolts,grouted to wall including taking down carefully geyser of any type any capacity from existing accn and depositing to MES store yard complete all as specified and as directed.Make: Jaquar Model: Versa Horizontal Manual Water Heater 100 Ltr(VRM-WHT-HD100)/ AO Smith Model: HSE-HAS/ Havells Model: Monza Ec 5S 100-L or equivalent. |
| 116 | Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately. Make: Legrand Cat No: 507745 or equivalent in Simens/ Havells/ L&T. |
| 117 | Supply and fix MCCB 160A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed. |
| 118 | Supply and fix MCB distribution board, SPN, 8 way, 230 V, 1 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately. |
| 119 | Supply and fix in replacement of MCB 63A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 120 | Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed. |
| 121 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter).The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 4000 kg load bearing capacity (Size:270 x 40 200mm) complete all as specified and directed. |
| 122 | Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 35 sqmm 3.5 core including taking up of old unsv cables of any size and make complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), cable protection HDPE pipe, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'. |
| 123 | Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 95 sqmm 3.5 core including taking up of old unsv cables of any size and make complete all as specified and directed.Note: Earth work ( Excavation, Returning & refilling and removal), cable protection HDPE pipe, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'. |
| 124 | Material and labour for Double wall corrugated HDPE pipe PN10, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed. |
| 125 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed. |
| 126 | Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 127 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 128 | M&L for feeder pillar bus bar panel outdoor type, double door, both side openable, locking arrangement(kiosk type), powder coated, 3.00mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of 400 Amp duly colour coded mounted on porcelain insulator, including MCCB 250 Amps, 4 pole, 35/36 kA,= 01 No, LED indicators (RYB), 08 Nos of holes in bottom for inlet and outlet cable with suitable size of cable gland and provn of angle iron stand of size 50 mm X 50 mm X 6 mm, 1.05 metre high (450mm below ground level and 600mm above ground) along with necessary cement concrete for grouting of panel stand and connecting the panel with earthing complete all as specified and directed.Note : (a) Feeder pillar box shall be got fabricated from CPRI approved and shall be from approved list of manufaturer only (b) Electric connection between MCCB and Busbar shall be with aluminium strip links duly colour coded and making 08 Nos of holes in bus bar for connecetion of XLPE cable using lugs of proper size.(c) MCCB shall be of Make-Havells/Legrand/ABB/C&S/L&T |
| 129 | Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed. |
| 130 | M&L for drilling/boring and tapping on existing CI/GI pipe pipe 40mm to 100mm dia size for branch connections of 15mm to 25mm dia by fixing of MS clamp of size 50x40mm cut to length and bent to shape, drilled and welded with GI socket of suitable size including rubber packing, nut, bolt and washer etc. and testing complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender