Tender For Construction Of New Poultry Rearing Space At Zakura Srinagar.(Adv. Cost Rs. 136.39 Lacs) (Incl Cost Of Material+Gst)
Tender Value
1.36 Crore
Estimated cost
Bid Submission
13 Nov 2026
9 days left
EMD
2.72 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of New Poultry Rearing Space At Zakura Srinagar.(Adv. Cost Rs. 136.39 Lacs) (Incl Cost Of Material+Gst)
BOQ
| Sl. No. | Item Description |
| 1 | Main Building |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared |
| 3 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. (50% in sides of foundation) |
| 5 | Supplying and filling in plinth with fine sand under floors including watering, raming consolidation and dressing complete |
| 6 | Providing supplying and stacking of soling including laying ramming complete as per engineer incharge |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 mix |
| 8 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate |
| 9 | providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 |
| 10 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level (1:1.5:3) |
| 11 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1.5:3 Columns |
| 12 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1.5:3 Beams |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc |
| 14 | Retaining walls, return walls, walls (any thickness) |
| 15 | Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Columns, piers, abutments, pillars, posts and struts |
| 17 | Suspended floors, roofs, landings, balconies and access platforms |
| 18 | Edges of slab and breaks in floors and walls |
| 19 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in super structure Upto Floor V Level (1:6mix) |
| 20 | 12mm Cement plaster of mix: 1:4 mix |
| 21 | 15mm Cement plaster on the rough side of single or half brick wall ofmix:1:4 |
| 22 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and hades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (600x600) |
| 23 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 24 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:Two or more coats applied @ 1.25 liter/10sqm over and including one coat of pecial primer applied @ 0.75liter /10sqm |
| 25 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) (Excel) |
| 26 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 27 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly einforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and ecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 28 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly forced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). |
| 29 | Providing and fixing with High rib coloured profile sheet roofing including vertical/curved surface including polymer coated J. or L hooks,fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters including Ridges, hips and valleys 0.5 mm thick |
| 30 | Providing and fixing Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 31 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 5.22C.1Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 32 | Sanitary and Plumbing |
| 33 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. PN-16 pipe, 25mm OD(SDR-7.4) |
| 34 | PN-16 pipe, 32mm OD(SDR-7.4) |
| 35 | PN-16 pipe, 20mm OD(SDR-7.4) |
| 36 | Providing and fixing PPR Unions PPR Union 20mm |
| 37 | PPR Union 25mm |
| 38 | Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete 15 mm nominal bore |
| 39 | 20 mm nominal bore |
| 40 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank incl carriage |
| 41 | Providing and fixing 15mm nominal bore CP brass wall mixer/basin mixer of approved brand and manufacture including all fittings and fixtures, complete job Jaguar or eqvilant |
| 42 | Providing and fixing 15mm nominal bore CP brass angle valve for basin mixer and gyser points of approved make conforming to IS 8931 |
| 43 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 44 | Providing and Fixing of PVC soil/waste/ventellating pipes with fittings like P-bend,D-bend,P or S-trap,F-Trap, collar, junction Door /Tee, Reducer, stays /clamps,vent cowel etc (B-Type) of approved brand and manufacture (Prince/ Supreme or Equivalent brand) incld all carriages 100mm nominal size dia |
| 45 | 75mm nominal size dia |
| 46 | 150 mm nominal size dia |
| 47 | Providing and fixing of 1.5 hp unidirectional flow motor of kirloskar or equivalent make and as per relvan IS specifications including all fittings viz; inlet & outlet connections & electric fittings complete as directed by Engineer incharge |
| 48 | Construction brick massionary manhole with 7.5 class designation bricks in cement mortar 1:4 (1 cement; 4 fine sand ) CI cover with frame , foundation concrete 1:3:6 (1cement : 3 fine sand :6 graded stone aggregrate 20 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished smooth with a floating coat of neat cement on walls and bed concrete etc complete as per standard design: as per the directions of site engineer incld all cost and carriage Inside dimensions 600x600 x750 mm deep |
| 49 | Providing and fixing G.I. inlet connection for flush pipe connecting withW.C. pan. |
| 50 | Providing and fixing of floor trap 100mm dia with grating |
| 51 | Providing and fixing of PV Collor 100mm dia |
| 52 | Providing and fixing of 100mm dia door T |
| 53 | Supply and fixing the following sizes of RIGID PVC conduits 1.8 mm thick (ISI Marked) complete with accessories such as bends, junction boxes, pull boxes etc., in recess or on surface including cutting chases in the walls/floors and making good the same complete as required.32 mm dia RIGID PVC conduits |
| 54 | 25 mm dia RIGID PVC conduits |
| 55 | 20 mm dia PVC flexible conduit |
| 56 | 25 mm dia PVC flexible conduit |
| 57 | 32 mm dia PVC flexible conduit |
| 58 | Carriage of material from various sources to site of work Sand & Agg Lead Upto 15KM |
| 59 | Carriage of material from various sources to site of work Bricks Lead upto 40Km |
| 60 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 61 | Providing and laying gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in Charge 18 mm thick |
| 62 | Providing edge moulding to 18mm/16mm thick Granite stone counters, Vanities etc including machine polishing to edge to give even high gloss finish etc complete as per design approved by engineer incharge (granite work) |
| 63 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately Chaar Gul including polishing etc complete (french sprit) |
| 64 | Providing and fixing frame work for khatamband 12mm thick ply board including cutting, placing, fixing etc complete job |
| 65 | P/F of 12mm thick T&G planks made of Imported wood (New zealand pine or equivalent) for roof soffits & Ceiling on wood work in false ceiling, partitions sawn and putup in position I/C of budloo wood ( Joists) vertical horizontal as desire at site 2\\"x 2\\". Including cost of necessary adhesive & cost of nails etc. with necessary cornice of required size complete. Incl cost of nails/screws all complete as approved by Engineer-in-charge (Including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 66 | Melamine polishing on wood work (one or more coats) |
| 67 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 68 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer, |
| 69 | Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture |
| 70 | Spckage Pit |
| 71 | Earth work in bulk excavation by mechanical means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil : |
| 72 | Dry random rubble masonry with hard stone in foundation and plinth: With bond stone |
| 73 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 74 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 5.22C.1Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 75 | Centering and shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platforms. |
| 76 | Carriage of Material Avg Lead 15Kms Sand and Aggregate |
| 77 | Carriage of Material Avg Lead 15Kms Stones |
| 78 | Litter Pit |
| 79 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 80 | Supplying and Laying of Nallah Dry Stone Soling hand packed tightly including ramming, watering and filling of interstices including all carriage complete. |
| 81 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 82 | Brick work with common burnt clay Modular bricks of class designation 7.5. in superstructure upto floor V in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 83 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 84 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 85 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\"rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. as per requirement of structural design including carriage of material involved. |
| 86 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 coarse sand) |
| 87 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 88 | Supplying and fixing C.I. cover without frame for manholes: 455x610mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. |
| 89 | Carriage of Stone Agg/ Sand lead 15M |
| 90 | Bricks Lead 40Km |
| 91 | Electric |
| 92 | Wiring for Light point/Exhaust/Bell/Fan Point point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab Green/Finolex/Salzer/Havells lifeguard Make) in surface/recessed Conduits laid in slabs(Including Cost of Conduit) with 01 No.of 6 Amp Modular Switch, Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/ Siemens/ABB Make & shall be approved before execution of work. |
| 93 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Anti-Bacterial Series of Legrand /L&T/ Siemens/ ABB Make & shall be approved before execution of work. |
| 94 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make & shall be approved before execution of work. |
| 95 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab Green/Finolex/Salzer/Havells lifeguard Make) Including termination and p/f of Copper thimbles of required size and number on input and out side rolled with colour coded type and p/f of ferriols on i/p and o/p side |
| 96 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make & shall be approved before execution of work. |
| 97 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in existing surface/Recessed Conduit (Polycab Green/Finolex/Salzer/Havells lifeguard Make) Including termination and p/f of Copper thimbles of required size and number on input and out side rolled with colour coded type and p/f of ferriols on i/p and o/p side |
| 98 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make & shall be approved before execution of work. |
| 99 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in existing surface/Recessed medium class PVC conduit (Polycab Green/Finolex/Salzer/Havells lifeguard Make) & shall be approved before execution of work. Including termination and p/f of Copper thimbles of required size and number on input and out side rolled with colour coded type and p/f of ferriols on i/p and o/p side 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 100 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards. |
| 101 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 102 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Legrand/L&T/Siemens/ABB Make |
| 103 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider/BCH Make) |
| 104 | Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider/BCH Make) 25-32Amp. |
| 105 | 40Amp. |
| 106 | 63Amp. |
| 107 | Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc. |
| 108 | Supplying and Fixing of MCB 8-Way (4+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make) |
| 109 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job. |
| 110 | Supply ,Laying of following PVC Conduits with allied accessories ,including cutting of walls /floors with hydraulic cutters and refacing to original position by way of p/l of cement concrete /POP and painting wherever required and as per instructions of EIC (BCH/Polycab/Finolex/Astral Make. 25 mm dia |
| 111 | 32 mm dia |
| 112 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required, ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make 5/6 A switch |
| 113 | 15/16 A switch |
| 114 | 3 pin 5/6 A socket outlet |
| 115 | 6 pin 15/16 A socket outlet |
| 116 | Supply and fixing of 18 Watt LED Powder coated die cast/Extruded aluminum Body including trim with Aluminum Reflector(System lumen efficacy ≥ 120 lm/Watt ) Recess/surface mounted (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. Luminaire shall be designed to emit initial system lumen output of greater than 2150 lumens .The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing /body should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason. Approved Make: Philips /Wipro /Regent /Endo /Surya/Halonix Make. |
| 117 | Supplying, installation, Testing & Commissioning of 100 Watt (System lumen efficacy ≥120 lm/Watt) Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 lm/Wattoutput . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason.Approved Make: Philips /Wipro /Regent /Endo /Surya/Halonix Make. |
| 118 | Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Halonix/Havells/Orient Make.(5-Star) |
| 119 | Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient/Halonix Make. |
| 120 | Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified. |
| 121 | Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683) suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires. |
| 122 | Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes. |
| 123 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required of Legrand/Panasonic/Anchor/Schneider/Equivalent Make |
| 124 | \\"Design, Fabrication, Assembly, Installation, Testing and Commissioning of Front Operated Cubicle type compartmentalized as per form 3B free standing, dust and vermin proof (IP 42ingress protection) LT panel suitable for use of 415 volts, 3 Phase 4 wire 50Hz suitable for a fault level of 55kA at 415 volts, fabricated from 2 mm thick Powder coated paint finish of approved shade CRCA MS sheet with hinged, gasketted9 metal based neoprene) and lockable doors having structural reinforcement with suitable angle/ channel/T / Flat section incl gland plates as required and lifting hooks with sleeved TPN AL Bus bars and Copper strip of required size with 2 no earthing terminals complete with interconnections as required for MCB's and control wiring. Each incoming / outgoing breakers shall have thermal magnetic release. :1.Incomer:-(a) 160 Amp TPN MCCB breaking capacity 36 kA with thermal release and adjustable settings with extended terminals of L&T/ABB/Seime /Legrend Make = 01 No. (b) 01 Set of R,Y,B Phase indicating lamps.(c) 01 No MFM with 630/5CT coils.(d) 200 Amp TPN Aluminum Bus Bar set with colour coding each sleeves 2. Generator Incomer:63 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 200 Amp Bus bar Al Strips(3+1) = 1 Set, Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set3. By Pass Switch: 63 Amp FP ByPass Switch of Legrand/Siemens/ABB//LK make = 1 No.,Outgoing :-(a) 32 Amp D.P MCB (1OKA) of L&T/ABB/Seimens /Legrend Make = 03 No. (b) 40 Amp D.P MCB (1OKA) of L&T/ABB/Seimens /Legrend Make = 03 No. (c) 63 Amp D.P MCB (1OKA) of L&T/ABB/Seimens/Legrend Make = 03 No. Panel shall have provision for entry of cables from the bottom as required.The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 125 | Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make. |
| 126 | Supply/Laying/Testing and Commissioning of 3.5- Core 95 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount/KEI Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation where required and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping.(Only required quantity shall be executed) |
| 127 | Supplying, Fixing of 16 Amp,3-Pin Top for Inverter I/p & O/p of Havells/Anchor/Wipro/Bajaj/GM Make |
| 128 | Supply/Installation/Testing/Commissioning of 3.5-4.5KVA/48 V Pure Sinewave Solar Inverter With ISOT Technology, Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 04 No. of 200Ah,12V Tubular battery (with 36 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc Luminious/EXIDE/AMRON Make. |
| 129 | Supply/Installation/Testing & Commissioning of 1-phase 10 KVA,50 Hz Oil cooled unbalanced type Voltage Stabilizer SERVO control of Approved brand COPPER wound of AE/Chinar/Cosco Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications :Input voltage(Ph-Ph) ranging from 90 Volts to 240 Volts and a balanced output Voltage of 230 Volts, ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Controller and Spike Protection. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender