Defence Statutory Bodies & Commissions/Committees Closing in 35 days TDR #58353905

Tender For Providing Of Otm Accn For Inf Bn (Ph-I) At Carnatic Lines At Mil Stn Damana Under Ge Jammu

Issued by Statutory Bodies & Commissions/Committees · jammu, Jammu and Kashmir
Tender Value
40.35 Crore
Estimated cost
Bid Submission
09 Dec 2026
35 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of Otm Accn For Inf Bn (Ph-I) At Carnatic Lines At Mil Stn Damana Under Ge Jammu

BOQ

Name of Work:- PROVN OF OTM ACCN FOR INF BN (PH-I) AT CARNATIC LINES AT MIL STN DAMANA UNDER GE JAMMU
Sl. No. Item Description
1Lumpsum price worked out by the contractor for Buildings Works as listed in Schedule 'A' Part-I.
2Lumpsum price worked out by the contractor for Earthwork, Site clearance & development as listed in Schedule 'A' Part-II.
3Lumpsum price worked out by the contractor for Road, Path, and culverts works as listed in Schedule 'A' Part-III.
4Lumpsum price worked out by the contractor for Internal water supply works as listed in Schedule 'A' Part-IV.
5Lumpsum price worked out by the contractor for Internal Electrification works as listed in Schedule 'A' Part-V (Sec-I).
6Lumpsum price worked out by the contractor for Sewage Disposal works as listed in Schedule 'A' Part-VI.
7Lumpsum price worked out by the contractor for Area Drainage works as listed in Schedule 'A' Part-VII.
8Lumpsum price worked out by the contractor for External Electric Supply works as listed in Schedule 'A' Part-VIII (Sec-I).
9Lumpsum price worked out by the contractor for External Water Supply works as listed in Schedule 'A' Part-IX (Sec-I).
10Lumpsum price worked out by the contractor for Hot Water Supply works as listed in Schedule 'A' Part-X.
11Lumpsum price worked out by the contractor for Demolition/ Dismantling works as listed in Schedule 'A' Part-XI.
12INTERNAL ELECTRIFICATION WORKS (Sch 'A' Part-V, Sec-II)Supply and fixing of DBOXx MCB Protected Socket With sheet steel Enclosure single pole 25 Amp with 3 pin plug top for AC connection from Socket point to stabilizer complete all as specified and as directed.
13Supply and fixing for LED lamp 10 watt B-22 holder base with polycarbonate body and aluminium heat sink warm white complete all as specified and as directed.
14S & F High performance IP66 LED Streetlight 25 watt, housing made of die-cast aluminium, with street optic lens,with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5sqmm from ceiling rose, to 25 W LED light etc. and including 32mm bore GI light grade protecion pipe upto 1.0m length with suitable fixing accessories on walls, complete all as specified and as directed complete all as specified and as directed.
15EXTERNAL WATER SUPPLY WORKS (Sch 'A' Part-IX, Sec-II)Supplying laying and testing ductile iron pipe 150mm bore spigot RM class K-9 as per IS-8329 with inside cement lined complete with push on rubber joints, all as specified and directed.
16Supplying laying and testing ductile iron pipe 100mm bore spigot RM class K-7 as per IS-8329 with inside cement lined complete with push on rubber joints all as specified and directed.
17Supply and fixing DI specials for spigot & socketed/flanged DI upto pipe size 150mm dia, such as bends (any type, radious and angle) Tapers any type (straight bends, increasing, decreasing or double socket etc) tee, pieces, single branches \\"Y\\" junction, double branches cross(all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
18Material and labour for construction of one brick thich (23 cm) Each masonary valve pit built in cement mortar 1:4 of size 900m x 900m x900mm (internal dimension), over 15cm thick PCC 1:3:6 type C-2 sub base extended alround 15cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:4 internally and flush pointing to brick wall surfaces externally as work proceeds complete with MS sheet cover 10 SWG with handle, angle iron frame 40mm x 40mm x 6mm (grouting with anchor fasteners length not less than 15cm-04 Nos) locking arrangement and painting complete all as specified and directed by Engr-in-Charge. (Rate quoted by the tenderer shall deemed to be included the cost of excavation and earth work).
19All as per Srl item No 18 above but size 600 x 600 x 600 complete all as specified and directed by Engr-in-Charge.
20Supply and fix cast iron air valves with two air outlets 150 mm dia Each bore and fixing up in cast iron water supply mains complete all as specified and directed by Engr-in-Charge.
21Supply and fix Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well (Casing pipe size 200/250 mm) supply and Install complete 16 WHP(35 HP) complete all as specified and directed.
22Supply and fixing of submersible cable 16 Sqmm 3 core flat copper conductor heavy duty 1100 volts grade confirming to ISI all as specified and directed by Engr-in-Charge.
23Supply and fixing in repair of fully automatic star delta starter 3 Each phase, 415 volt, 50 Hz, suitable for submersible pumping set heavy duty with overload relay range suitable for 35 HP complete with provn of power contactor volt/Amp meter, push ON/OFF switch, selector switch, indicator etc.
24EXTERNAL ELECTRIC SUPPLY WORKS (Sch 'A' Part-VIII, Sec-II)Supply, Installation and Commissioning of Outdoor Type Compact Sub - Station (CSS) having 1 way 11kV, 630 Amp SF6 RMU, 630 KVA Copper Wound Oil Cooled Off- Circuit Transformer, LT Panel including necessary PCC works for foundation of SF6 RMU, Transformer complete all as per Manufacturer recommendations : HT Section-1 NosRMU-NON-Extensible 1 way, 11kV, CV, 1 SF6 circuit breaker along with connected accessories etc.) Type: - Free Standing, Metal Clad, SF6 insulated Ringmaster with 1 no. 630A fixed manual SF6 circuit consisting of the following:a. Self Powered Relay, Type IDMTb. Ring Switches and T OFF SF6 circuit breaker with Integrated Earthing Switches Live Cable Indicator for Ring Switchesd. Padlocking facilitye. Shunt trip coil rating-230V ACf. Current Transformer-Cast resin Ratio: 100/1A, Core1:Cl.0.5, 15VA, Core2: Cl.5P10, 15VAg. Protection - Numerical 20C + 1EF Relayh. Micro Processed based Non-Directional IDMT Relayi. Indication Lamps - VCB off/on / auto trip/ Trip circuit healthy/spring charge indicationj. Metering - Digital Ammeter\\"
25Transformer Section - 1 SetTransformer Outdoor-630 kVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down \\"BIS Marked & BEE Star Labelled\\" Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box Transformer as per IS-1180(Part-1)2014 EEL-3 with amendment no.- 4 Losses @50% Load-1637WLosses @100% Load - 4438W\\"LT Section-1setLT Panel comprising of LV SideIncomer- 01 No. 1000A 4P 50KA 415V Air Circuit breaker Manual Fixed based with O/L, S/C & E/F protection.- RYB Indication-1000A/SA LTCT Cl:1.0- Ammeter-Voltmeter\\"Outgoing -01 no. 400A 4P 36 KA 415V MCCB with Thermal based release with O/L & S/C protection.-01 no. 320A 4P 25 KA 415V MCCB with Thermal based release with O/L & S/C protection.-01 no. 63A 4P 25 KA 415V MCCB with Thermal based release with O/L & S/C protection.- 01 no. 63A 10 KA 415V MCB TPN
26Enclosure - 1setSpace Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB's for AC / DC Control CRCA Sheet enclosure (2.0 mm) suitable for Outdoor Installation with MS base channel. Provision for receiving Incoming & Outgoer cables through bottorn entry excluding termination kit & glands.Inter Connection - 1setMain Bus Bar/ Inter Connection - From RMU to transformer - Aluminum CableMain Bus Bar - From Transformer to LT Panel - Aluminum BusbarEarth Bus Bar - G.I StripNeutral Earth - G.I StripPaint shade: Siemens Grey (RAL 7032)
27Supply and Fixing of Automatic power factor control panel with MD- XL capacitor and MCCB Adjustable Thermal and Adjustable magnetic 630Amps, 4Pole, 50 KA-1No as incomer auto/ manual operation suitable for 3 phase 440 V 50 HZ 300 KVAR capacity in (4 x12.5 KVAR) (2 x 25 KVAR) (4 x 50 KVAR) steps with suitable contactors, microprocessor based 6 stage APFC relay with display of multi parameters, auto/ manual mode, with back up HRCS fuse on each capacitor banks, ammeter, voltmeter, selector switch, CT's, thermostat control axial fan ,duly internal wired suitable aluminimum bus bar 3 phase 4 wire, panel shall be indoor type made out of CRCA sheet 2mm thick duly powder coated complete testing and commissioning all as specified and directed by Engr-in-charge.
28S&F Street light bracket made out of GI tubing suitable for 35/45/60 watt LED light light grade upto 1.2 mtr length, bend to shape suitable for security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and as directed.
29PVC Junction Box of size 155 x 210 x 92 mm with locking arrangement suitable for 04 Nos cable connectors, complete with suitable size of cable glands & MS clamps nuts, bolts & washers etc complete all as specified and directed.
30Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of size 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
31S & F LT feeder pillar panel suitable size out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and rear openable double door system and cable alloy ,make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following (Near Adm Block, LTP 1)(a) Aluminum bus bar 315 Amps 4 pole - 01 set(b) MCCB 4 pole 250 Amps 35KA adjustable type -01 No (incommer)(c) MCCB 4 Pole 100 Amps 25 KA adjustable type- 03 Nos(d) Digital volt meter 0-500 V with selector switch - 01 No(e) Digital Ammeter 0-400Amps with selector switch - 01 No(f) Set of 3 phase RYB indicator - 01 Set(g)Digital Timer Switch 230VAC, 50Hz rating of 16A,switching interval of 1 minute, IP 20
32All as per item No 29 with the following:- (G+3 LTP 6,7,8,9, LIFT LTP 3)(a) Aluminum bus bar 160 Amps 4 pole - 01 set(b) MCCB 4 pole 100 Amps 25KA adjustable type - 01 No (incommer)(c) MCCB 4 Pole 63 Amps 16 KA adjustable type-02 No(d) Digital volt meter 0-500 V with selector switch - 01 No(e) Digital Ammeter 0-100Amps with selector switch - 01 No.(f) Set of 3 phase RYB indicator - 01 Set
33All as per item No 29 with the following:- (OTM, LTP 4 & LTP 5) (a) Aluminum bus bar 630 Amps 4 pole - 01 set(b) MCCB 4 pole 400 Amps 36KA adjustable type 01 No (incommer)(c) MCCB 4 Pole 100 Amps 25 KA adjustable type-05 No (Spare)(d) Digital volt meter 0-500 V with selector switch - 01 No(e) Digital Ammeter 0-100Amps with selector switch - 01 No(f) Set of 3 phase RYB indicator - 01 Set(g)Digital Timer Switch 230VAC, 50Hz rating of 16A,switching interval of 1 minute, IP 20
34All as per item No 29 with the following:- (Offrs Mess, LTP 2)(a) Aluminum bus bar 200 Amps 4 pole - 01 set(b) MCCB 4 pole 160 Amps 25KA adjustable type - 01 No (incommer) (c) MCCB 4 Pole 100 Amps 25 KA adjustable type-01 Nos(d) MCCB 4 Pole 63 Amps 25 KA adjustable type-02 Nos(e) Digital volt meter 0-500 V with selector switch - 01 No (f) Digital Ammeter 0-100Amps with selector switch - 01 No (g) Set of 3 phase RYB indicator - 01 Set(h)Digital Timer Switch 230VAC, 50Hz rating of 16A,switching interval of 1 minute, IP 20
35Supply and installation of silent Diesel Engine driven generating set capacity 15 KVA 415 volts, 3 phase 4 wire, Silent CPCB IV+, engine as per IS: 10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, AMF, control panel having meter, in built fuel tank, silencer and battery & Battery Charger with Electronic governor and sound proof canopy and foundation etc. including PCC plinth (size 2.5 x 1.5 x 0.6 Mtr) with brick work for DG set foundation the following parts as scope of supply: 1) 4 stroke, turbo charged aspirated engine operating at 1500 RPM rated for Prime duty comprising of Engine mounted radiator.ang2) Flywheel. 3) 12 V Electrical starting system, Starting battery, 12V-1No.4) Air filter Lube oil filter.5) First Fill of Consumables, e.g. Lube Oil, Coolant, etc.6) Base frame for mounting engine and Alternator AVM Pads.7) Alternator-Brushless, self-excited, 4P, 1500 rpm, 50Hz in IP-23 enclosure generating 415Volt at 0.8p. f (lag).8) The alternator shall conform to IS: 4722/IEC34. 1and is suitable for tropical conditions.
369) Silencer. 10) Engine control panel (On/Off start, Coolant /Water temperature Display, lube oilpressure Display, Ammeter display, Hour meter etc.). 11) 3P MCCB for power outlet. 12) Genset Enclosures are modular type built with provision for easy assembling and dismantling.13) The structure is fabricated using CRCA (cold rolled cold-annealed sheets FR PU Acoustic foam confirming UL94-1998HF-1 of suitable thickness & Density is used for acoustic purpose to reduce the sound level down to permissible limits (75 dBA at 1 mtr distance from enclosure surface) as per norms. The doors are fitted with high quality EPDM gaskets to avoid leakage of sound. The door handles are lockable type. The enclosure is Surface treated and painted/ powder coated for the longer life and to make it weather proof suitable for outdoor operation
37Supply and installation of Electrical Chimney, Auto clean ceiling mounted chimney capacity 1300 cum/Hr complete all as specified and directed.
38Supply and installation of Electrical heavy duty food warmer 10 pot SS body, 3 KW for cook houses complete all as specified and directed.
39CONDUIT FOR TV/ TELEPHONE/ INTERCOM/ LANSupply and fixing rigid non-metallic PVC conduits exclusive of boxes (junction/ terminals) but inclusive of all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of external dia size as under.
4032mm complete all as specified and directed.
4125mm complete all as specified and directed.
4220mm complete all as specified and directed.
43Supply and fixing junction boxes (1-4 way) PVC type
4432mm complete all as specified and directed.
4525mm complete all as specified and directed.
4620mm complete all as specified and directed.
47Supply and fixing socket outlet for LAN modular type 1 module alongwith gangbox and face plate ISI marked with valid CML No. complete all as specified and directed.
48Supply and fixing socket outlet for Tele modular type 1 module alongwith gangbox and face plate ISI marked with valid CML No. complete all as specified and directed.
49Supply and fixing socket outlet for TV modular type 1 module ISI marked with valid CML No. completes all as specified and directed.
50LIFTSupply and fix lift electrically operated microprocessor cotrolled complete with power driven automatic stainless steel (SS) sliding doors and having SS car enclosure, sulable to carry 8 passengers (544 Kg) at a speed of 1.0 m/sec to serve upto 4 floors (Four storeys, G+3) having following Specification- 1.PRODUCT: GeN2-Nova_MRL-1MPS2.DETAILS: GeN2-Nova_MRL-1MPS3.CAPACITY (kgs): 544 Kg, 8 persons.4.SPEED (mps) : 1 mps5.RISE (m): 12 m6.STOPS: 4 Stops With (all opening on the same side)7.CONTROLLER TYPE: ACD5-MRL8.DRIVE: VF Regenerative (Closed Loop)9.POWER SUPPLY: 400/415 Volts (3 Phase AC)10.OPERATION: Full collective operation11.CAR GROUP: One car (simplex)12.MACHINE: PM Gearless (Located in shaft on top of guide rails) 13.TRACTION MEDIA: Flat Coated Steel Belt14.CAR FINISH: Rear Mid Panel = Stainless Steel #4(Hairline).Rear Corner Panels = Stainless Steel #4(Hairline).Side Mid Panels = Stainless Steel #4(Hairline).Side Corner Panels = Stainless Steel #4(Hairline).Front Panels = Stainless Steel #4(Hairline)
5115 FALSE CEILING TYPE: CD-6116.FLASE CEILING FINISH: Stainless Steel #4(Hairline) 17.VENTILLATION: Cross flow fan18 HAND RAILS: Stainless Steel Mirror Finish Handrails on rear car panels 19 FLOORING: Vinyl Tiles20 CAR DOOR FINISH: Stainless Steel #4(Hairline)21.LANDING DOORS FINISH:Stainless Steel #4(Hairline)22 FIRE RATED DOORS: Fire rating-60mins23 PIT DEPTH: 135024.OVERHEAD 420025.HOISTWAY DIMENSIONS(WxD-mm):1850 mm W x 2450 mm D26.CAR DIMENSIONS (WXDx H-mm):1100 mm W x 2000 mm D x 2200 mm D27.CAR & HOISTWAY DOOR28.TYPE:Centre Opening doors29.DOOR OPENING (W X H -mm):800 mm W x 2000 mm H30 DOOR OPERATOR: DC Door Operator31.COP: COP for stops <= 12 (950mm) in Stainless Steel #4(Hairline)
5232 CAR POSITION33 INDICATOR: Monochrome LCD-Blue Background & White fontDot matrix (LED) Scrolling Display34.HALL FIXTURES: 02000Pan Type Fixture,35.HALL FIXTURE FACE PLATE Stainless Steel #4(Hairline)36 HALL BUTTONARRANGEMENT: LCD Monochrome type37.STANDARD FEATURES: Anti-nuisance Car Call Protection38.Overload Device Nudging39.Emergency Car Light Unit40.Infrared Curtain Door Protection41.Door Time Protection42.Emergency Alarm Button43.Extra Door Time of Lobby & Parking44.Door Open/Close Button45.Manual Rescue OperationBelt Inspection Drive46 Auto Fan Cut Off47.OPTIONS INCLUDED: Car Chime, Emergency Firemen's Service, Automatic Rescue operation, Voice Synthesizer, Intercom,Audible Car Call Button.
53Material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick burried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B- 1 using 8mm tor steel bars @10èm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed.
54STPDesign, Supply, installation, testing and commissioning of STP of capacity 130 KLD based on any suitable technology/method as per Geographical location, temperature differential and rainfall complete with Mechanical, Electrical with tertiary treatment facilities to achieve designed Parameters of Sewage which should be maintained and provide treated sewage Parameters as per the CPCB-2026 Standards and as mentioned below :- i) pH Value should be between 6.5-8.3ii) Chemical Oxygen Demand (COD) < 50 mg/Ltriii) Biological Oxygen demand (BOD) <10 mg/Ltriv) Total Suspended Solids (TSS) < 10 mg/Ltr v) Total Nitrogen 10 mg/Ltr vi) Total Phosphorus 1 mg/Lvii) Fecal Coliform - Nilvii) Odour - No foul odourix) Ammoniacal Nitrogen (-N): <= 5 mg/L Please Enable Macros to View BoQ information
55STPDesign, Supply, installation, testing and commissioning of STP of capacity 130 KLD based on any suitable technology/method as per Geographical location, temperature differential and rainfall complete with Mechanical, Electrical with tertiary treatment facilities to achieve designed Parameters of Sewage which should be maintained and provide treated sewage Parameters as per the CPCB-2026 Standards and as mentioned below :- i) pH Value should be between 6.5-8.3ii) Chemical Oxygen Demand (COD) < 50 mg/Ltriii) Biological Oxygen demand (BOD) <10 mg/Ltriv) Total Suspended Solids (TSS) < 10 mg/Ltr v) Total Nitrogen 10 mg/Ltr vi) Total Phosphorus 1 mg/Lvii) Fecal Coliform - Nilvii) Odour - No foul odourix) Ammoniacal Nitrogen (-N): <= 5 mg/L Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58353905
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.35 Crore
LAST DATE 09-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Otm Accn For Inf Bn (Ph-I) At Carnatic Lines At Mil Stn Damana Under Ge Jammu
Basic Detail
Tender No CA NO CEPZ-11/2026-27
Bidding Type Tender
Location
City jammu
State Jammu and Kashmir
Key Dates
Publish Date 03 Nov 2026
Submission Date 09 Dec 2026
Open Date 16 Dec 2026
Finance
Tender Value 40.35 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
binder1.pdf
binder10.pdf
binder11.pdf
binder12.pdf
binder13.pdf
binder14.pdf
binder15.pdf
binder2.pdf
binder3.pdf
binder4.pdf
binder5.pdf
binder6.pdf
binder7.pdf
binder8.pdf
binder9.pdf
BOQ_894095.xls
Tender1.pdf
Tendernotice_1.pdf
be6d6b8a-37c3-4c29-8419-39afd59eb884.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 35 days
Dec 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 42 days

Tender Documents

Download All (ZIP) ↓
pdf

binder1.pdf

pdf

binder10.pdf

pdf

binder11.pdf

pdf

binder12.pdf

pdf

binder13.pdf

pdf

binder14.pdf

pdf

binder15.pdf

pdf

binder2.pdf

pdf

binder3.pdf

pdf

binder4.pdf

pdf

binder5.pdf

pdf

binder6.pdf

pdf

binder7.pdf

pdf

binder8.pdf

pdf

binder9.pdf

xls

BOQ_894095.xls

pdf

Tender1.pdf

pdf

Tendernotice_1.pdf

html

be6d6b8a-37c3-4c29-8419-39afd59eb884.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender