Tender For Addition/Alteration To Bldg No P-15 At Af Stn Darbhanga Under Ge Af Bihta.
Tender Value
43.53 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
19 days left
EMD
87060
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darbhanga → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition/Alteration To Bldg No P-15 At Af Stn Darbhanga Under Ge Af Bihta.
BOQ
| Sl. No. | Item Description |
| 1 | B/R WORKS |
| 2 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified. |
| 4 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. |
| 5 | Cement concrete, type B-0 (1:2:4), using 12.5 mm graded stone aggregates as in lintels up to 1.5 metre clear span, bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified. |
| 6 | Reinforced cement concrete, type B-1,(1:2:4), (nominal mix) using 20 mm graded stone aggregates as as in beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified |
| 7 | Brick work using using bricks as specified in PS-II clause 5.1 straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified. |
| 8 | Brick work in half brick thick wall using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified. |
| 9 | Cutting holes into or through RCC/brick walls built in cement mortar exceeding half brick thick but not exc one brick thick for inserting angle/tee/pipe/ hold fast or similar purposes etc. and making good in cement mortar 1:3 or cement concrete 1:2:4, Type B-1 as required complete all as specified. |
| 10 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window /Ceosetory windows & other Frames/Chowkhat of size 45x70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gm) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/Cu.m, screw withdrawl strength of 2200N Face & 1100 N (Edge), minimum compressive strength of 58 N/ Sq.mm, modules of elasticity 900 N/Sq.mm and resistance to spread of flame of Class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete.NOTE- WPC solid door/window frames, minus5mm tolerance in dimension i.e depth and width of profile shall be acceptable, Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 11 | Factory made, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, 30 mm thick, ISI marked, complete all as specified. |
| 12 | Factory made solid PVC moulded door shutter, 28-30 mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2 mm thick prelam PVC sheet on back face, all as per specification complete all as specified. |
| 13 | Aluminium anodised barrel tower bolt of extruded section 150mm long, ISI marked, complete all as specified. |
| 14 | Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250 mm long, complete all as specified. |
| 15 | Stainless steel 100mm long butt hinges with stainless steel screws, ISI marked complete all as specified. |
| 16 | Extruded aluminium anodised handles fabricated type with plate 150 mm long, ISI marked complete all as specified. |
| 17 | Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, complete. |
| 18 | Aluminium (Die cast) door closer hydraulically regulated designation No. 3 aluminium body universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg, ISI marked, complete all as specified. |
| 19 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 20 | Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified. |
| 21 | Framed mild steel work such as grills, chowkhats for fixing of door, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, complete all as specified. |
| 22 | Collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified. |
| 23 | Powder coated aluminium frame for doors, windows, ventilators, fixed glazing with one or more rebates including joining cleat for fixing, fixed to opening with suitable size steel screws and rawl plugs etc. complete all as specifiedNote :Powder coated aluminum sections minimum thickness of powder coating shall be 50 micron. |
| 24 | Powder coated aluminium door shutters, anodised alumnium glazing snap beading , rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges.(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.(d) aluminium section not less than 2 mm. |
| 25 | Powder coated aluminium window and ventilator shutters side hung type without sash bar, anodised alumnium glazing snap beading rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye.(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron. d) aluminium section not less than 2 mm. |
| 26 | Water Proofing Treatment to RCC roofs comprising of : - |
| 27 | Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified. |
| 28 | Rendering 15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fair in cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ. |
| 29 | APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified. |
| 30 | Roof cool tile of size 300 x 300mm thick 8-9 mm thick to reduce room temperature slip resistance white in colour having properties like water absortion max 3.3 % breaking strength 1000N moisture expansion max 3 % scratch hardness 4 min thermal stock resistance 10 cycles min impact resistance 0.55, and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified. |
| 31 | Making benching with PCC (1:2:4) type B-0 (using water proofing compound) along side walls adjoining to roofs, in CONCAVE SHAPE, complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ. |
| 32 | NOTE : For Guarantee of Water Proofing Treatment refer PS clause 11.5. |
| 33 | Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete, all as specified. |
| 34 | Anodised aluminum snap grid frame work with 20x25mm 'T' and 20x20mm 'L' section with grid size of 605x605mm including with necessary 3.15mm GI wire as in suspended complete all as specified. |
| 35 | Seamless calcium silicate ceiling made out of 12 mm thick1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish, complete all as specified.NOTE: Frame work & hangers for ceiling shall be measured and paid separately) |
| 36 | 100 mm thick, cement concrete type B-2, 1:2:4 using 40 mm graded stone aggregate, finished even & rough, as in floors/path , complete all as specified. |
| 37 | Glazed ceramic coloured tiles 7-8 mm thick, area of each tile exc. 0.13 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified |
| 38 | Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:6), complete all as specified. |
| 39 | Coloured vitrified dark shade tiles 9-10mm thick (square/ rectangular) area of each tile n. exc. 0.36 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified. |
| 40 | Factory made PCC colured chequered tiles, ISI (IS:13801) marked, 22-25 mm thick, of size 250 mm x 250 mm, in floors, over & including 15 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry complete, all as specified. |
| 41 | 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete. |
| 42 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth on walls in cement mortar (1:4), complete all as specified. |
| 43 | Supply only intgral water proofing compound, ISI marked, complete all as specified. |
| 44 | Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, average 2mm thick & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemper over and including a coat of acrylic emulsion primer. |
| 45 | Prepration of new plasterd wall surfaces of any description & applying Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer complete all specified |
| 46 | Three coats of white washing on new plastered ceiling surfaces, including preparation of surfaces, complete all as specified. |
| 47 | Removing old lime wash (if any) hacking for key, raking out joint of old brick work or stone work built in cement mortar, not previously plastered and scrubbing down with water etc to receive plaster complete all specified |
| 48 | Sheet glass 4 mm thick ordinary quality and glazing with neoprene packing in squares n. exc. 0.5sqm in each pane complete all as specified. |
| 49 | Sheet glass 4.4 mm thick ordinary quality and glazing with with neoprene packing in squares exc. 0.5sqm in each pane complete all as specified. |
| 50 | Two coats of synthetic enamel paint over & including a coat of pink primer over wood and wood based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified. |
| 51 | Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified. |
| 52 | Steel tubes 20 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as specified. |
| 53 | Unplasticised PVC pipes 15mm bore of pressure rating 0 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified. |
| 54 | 500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, IN-REPAIRS, complete all as specified including the following acessories: -(i) PTMT ball valves, high pressure, with epoxy coated aluminium rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, IN REPAIRS, complete all as specified.(iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, IN REPAIRS, complete all as specified.(iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP, IN REPAIRS, complete all as specified. |
| 55 | Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 20mm bore pipe,IN REPLACEMENT, complete. |
| 56 | Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPLACEMENT, complete. |
| 57 | Pillar tap, cast copper alloy chromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPLACEMENT, complete. MAKE: Prayag Cat No. 6502 or equivalent make mentioned in Appendix 'B' |
| 58 | Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, with & including stainless steel body Jet spray (L-bend) with 1.50 metre long braded tube tube, soft close ISI marked PVC seat & cover, , complete all as specified. |
| 59 | Vitreous China half stall type (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plug with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe including waste coupling suitable for urinals min weight 32mm-45gms including botlle trap of PTMT having minimum water seal of 25mm min weight 32mm-260 gms IN REPLACEMENT, complete. |
| 60 | Vitreous China wash basin, white, oval type, size 550 x 400 mm, ISI marked, including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, IN REPAIRS, complete all as specified. |
| 61 | PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, IN REPLACEMENT, complete. |
| 62 | Looking mirror 600 x 450 mm, selected quality glass 5.5 mm thick, mounted on PVC ply not less than 6 mm thick, and provision of PVC frame alround fixed with chromium plated brass screws and rawl plugs,IN REPLACEMENT complete all as specified. |
| 63 | Health faucet with 1 metre SS tube & hook, IN REPLACEMENT, complete. MAKE: Jaquar Cat No. ALD- or equivalent make mentioned in Appendix 'B' |
| 64 | Stainless steel soap dish, fixed to wall with SS screws and PVC rawl plugs, IN REPAIR, complete. |
| 65 | PVC connections 15 mm size of length 600 mm with PTMT nuts, IN REPLACEMENT complete all as specified |
| 66 | Waste fittings brass chromium plated cupling and for 32mm dia glazed ware sink, basin, urinal etc with PVC pipe long screwed shanks and fly nuts flazed ends bedded in red lead cement and other end, IN REPLACEMENT, complete all as specified |
| 67 | uPVC pipes, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors / fixed to wall as SWR pipes, IN REPLACEMENT, complete all as specified of size: - |
| 68 | 75 mm external dia pipe |
| 69 | 110 mm external dia pipe |
| 70 | uPVC/PVC bend any radius, complete all as specified. suitable for uPVC soil waste discharge pipes, of size: |
| 71 | 75 mm external dia pipe |
| 72 | 110 mm external dia pipe |
| 73 | uPVC/PVC single T, equal or unequal, suitable for uPVC soil waste discharge pipes 75 mm external dia, IN REPAIR, complete all as specified. |
| 74 | uPVC/PVC single T, equal or unequal, suitable for uPVC soil waste discharge pipes 110 mm external dia, IN REPAIR, complete all as specified. |
| 75 | 75mm dia uPVC / PVC floor trap with grating including jointing with solvent and embedding in cement concrete type B-1 (1:2:4) complete all as specified. |
| 76 | E/M WORKS |
| 77 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI sunken boxes made out of 1.2mm thick MS sheet, 60mm deep concealed in wall modular metal flush box & including modular cover plate with frame having necessary cutting for fixing switches/ sockets comprising the following: - |
| 78 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 79 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified. |
| 80 | One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable &1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 81 | One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 82 | One socket outlet three pin, 6/16 Amp, independent, with 4 Sq. mm (nominal area) cable & 4 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 83 | NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4). |
| 84 | Switch modular type single pole one way, 6 Amp, 1 module complete all as specified. |
| 85 | Switch modular type single pole one way, 16 Amp, 1 module complete all as specified. |
| 86 | Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, 2 Module complete all as specified. |
| 87 | Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, 2 Module complete all as specified. |
| 88 | Fan regulator modular type (electronic) suitable for 48”/56” sweep fan, step type, two module, complete all as specified. |
| 89 | Modular type RJ 45 with two module with shutter complete all as specified. |
| 90 | Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified. |
| 91 | Lamp (angle) holder, PVC/ polycorbonate type with back plate suitable for batten fittings complete, all as specified. |
| 92 | Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, with and including rigid non metallic PVC medium duty concealed conduit not less than 25mm dia complete all as specified for the following: - NOTES: (i) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as \\"1 RUNNING METRE\\" |
| 93 | 2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable |
| 94 | 2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable |
| 95 | 2 runs of 10 Sq. mm main cable + 1 run of 10 Sq. mm earth cable |
| 96 | Rigid non metallic, PVC conduit,40 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified. |
| 97 | Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection with magnetic locking system, including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing surface , IN REPLACEMENT, complete all as specified comprising the following: |
| 98 | SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type. |
| 99 | SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type. |
| 100 | SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type. |
| 101 | TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type |
| 102 | TPN, 8 way with 200 Amp rated bus bar, 415 V, double door type |
| 103 | MCCB 125 Amp, 36 kA. 415 volts AC supply, 50 Hz, 4 pole with over load and short circuit protection, adjustable thermal & adjustable magnetic release type, complete all as specified |
| 104 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified. |
| 105 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp complete all as specified. |
| 106 | MCB suitable for 415 volt AC supply, TP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 25-63 Amp complete all as specified. |
| 107 | MCB suitable for 415 volt AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40-100 Amp complete all as specified. |
| 108 | Metal clad box suitable for 230 volt 50 Hz for AC connection three pin and socket with MCB SP 20/32 Amps including taking down existing clad box complete all as specified. |
| 109 | LED bulb 9 / 10watt B-22 Cap, highly efficient complete all as directed. |
| 110 | Surface mounted Environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 20 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt, IN REPLACEMENT, completeMAKE: Havells Cat No. LHEXBLP7PN1W018 or equivalent in makes mentioned in Appendix 'B' |
| 111 | Surface mounted environment friendly LED 10 W batten with polycarbonate housing & integrated electronic driver with THD<10% , lumen output should not be less than 90 lumens per watt, IN REPLACEMENT, completeMAKE: Havells Cat No. LHEXACP7INW010 or equivalent in makes mentioned in Appendix |
| 112 | LED 36 watt recessed 600mmx600mm luminaire Warm White which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid Ceiling including LED driver and connection with 3 core copper wire incl all accessories, IN REPLACEMENT complete all as specified |
| 113 | LED street light fittings 35 watt, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, IN REPLACEMENT, complete all as specified |
| 114 | Security light bracket made of 40 mm bore GI light grade pipe 1.5 metre long bend to shape including necessary welding to pole(s) or fixed with suitable size of flat iron clamps, nuts, bolts and washers etc. IN REPLACEMENT, wit & including two coats of synthetic enamel paint over a coat of primer complete all as specified |
| 115 | Exhaust fan steel body of size 300mm sweep with louvers, 900 RPM 230 volts single phase AC supply complete with bolt, nuts and washer and including PVC insulated and overall sheathed flexible 3 core 0.5 Sq.mm copper conductor cable from ceiling rose to exhaust fan for giving connection complete all as specified. |
| 116 | Exhaust fan steel body of size 450mm sweep with louvers, 900 RPM 230 volts single phase AC supply complete with bolt, nuts and washer and including PVC insulated and overall sheathed flexible 3 core 0.5 Sq.mm copper conductor cable from ceiling rose to exhaust fan for giving connection complete all as specified. |
| 117 | GI earthing wire of size 4mm including fixing in wall with proper nuts, bolts, washer etc complete all as specified. |
| 118 | Dismantling of complete defective ceiling fan of 1200 mm sweep (i.e.,) down rod with its Canopies, Shackle, Blade, Condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding, ball bearing, gun metal bush etc. complete to carry out the following repairs :-(a) Removing of burnt out fan winding and rewinding of starter winding with suitable size of Copper enamelled wire, ( weight of copper coil shall be same as per dismantled Fan) varnishing heating and testing as per manufactures designed & specifications and as directed by Eng-in-Charge. (b) Re-assembling complete ceiling fan by fixing only serviceable of old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushed, blades, ball bearing, twin twisted copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling, painting, cleaning outer body & surfaces etc complete all as specified and directed. Please Enable Macros to View BoQ information |
| 119 | Dismantling of complete defective ceiling fan of 1200 mm sweep (i.e.,) down rod with its Canopies, Shackle, Blade, Condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding, ball bearing, gun metal bush etc. complete to carry out the following repairs :-(a) Removing of burnt out fan winding and rewinding of starter winding with suitable size of Copper enamelled wire, ( weight of copper coil shall be same as per dismantled Fan) varnishing heating and testing as per manufactures designed & specifications and as directed by Eng-in-Charge. (b) Re-assembling complete ceiling fan by fixing only serviceable of old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushed, blades, ball bearing, twin twisted copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling, painting, cleaning outer body & surfaces etc complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender