Tender For Construction Of Reading Hall In Pioneer Street At Ward No.10
Tender Value
8 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
2 days left
EMD
8000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanniyakumari → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Reading Hall In Pioneer Street At Ward No.10
BOQ
| Sl. No. | Item Description |
| 1 | Construction of Reading hall |
| 2 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls .Dismantling RCC by manual / by using deploying machineries |
| 3 | Earth work excavation and depositing on bank with initial lead of 10metres and lift of 2metres in all kinds of soil except mediumrock, dense medium rock and hard rock requiring blasting including refilling the sides of foundation with excavated earth in layers of 15cm thick, watering and consolidation and depositing the surplus earth with in the compound in places as shown by the departmental officers with initial lead and lift. cleaning,levelling the site etc,. complete complying with standard specifications.(TNBP No.20B) |
| 4 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means |
| 5 | Refilling the foundation with excavated soil (other than sand )in layers of not more than 15cm thick,watering,well ramming,consolidating,complying with standard specification and as directed |
| 6 | Providing steel centering for sides and soffits including supports and strutting upto 1:10/1:20 up to 3.29m height for plain surfaces such as RCC slabs, rectangular beams, Tee beams, bed blocks, Culvert body walls, deck slabs, retaining walls, staircase, Landing slab, landing beams, canopy etc., with all cross bracings using mild steel sheets of size 90mm x60mmx10gauge stiffened into welded mild steel angles of size 25mmx6mm for boarding laid over silver oak (Country wood) joists of size 10cmx 6.5cm spaced at 90cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at 15cm c/c including cost of nails, ropes, all labour charges and incidental charges etc. complete complying with standard specification.(TNBP Spl. No.154 A) |
| 7 | (b)Steel centering for lintel |
| 8 | (c)Steel centering for column |
| 9 | (d)Steel centering for Roof beam/slab |
| 10 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 11 | b)Super Structure in ground floor |
| 12 | Supplying, fabrication and placing in position of steel reinforcement using mild steel (or) ribbed tar steel rods, for all RCC works as per the design given by the departmental officers including cost of steel and binding wire and all labour charges for cutting, bending rods, tieing into grills, placing in position etc., complete as directed by the departmental officers.( TNBP No: 15886) |
| 13 | Brickwork in cement mortar 1:5 (one cement and five sand) using country bricks of size 83/4\\"x41/4\\"x23/4\\" including curing, cost and conveyance of all materials to site and all labour charges etc. complete as per standard specificationsa)Foundation & Basement |
| 14 | (b)Super Structure in ground floor |
| 15 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 16 | Supply and installation of two-track sliding uPVC windows shall utilize uPVC profile sections with an outer wall thickness of .30mm (±0.2mm), featuringan outer frame of 60mm x 52mm, a shutter of 66mm x 42mm x 50mm, an interlock of 45mm x 36mm, and a glazing bead of 24.5mm x 16mm. All frame, sash, and mullion profiles shall be reinforced, where required, with a 1mm thick GI steel section, and windows are to be equipped with security devices such as touch locks or crescent locks, nylon rollers, and an aluminium track, all compliant with relevant specifications and departmental directives. Glazing shall consist of 5mm thick Plain or Pinhead glass, secured by TPE (Grey) weather-sealed gaskets, while all corners and mullion joints of the frame and sash shall be mitred cut and fusion welded without mechanical joints, with all welded joints neatly rimmed to a grooved nib finish, ensuring sharpedge-free products. The complete window units shall be fixed into pre-finished openings by drilling and fastening through the outer frame with highquality fasteners, and silicon sealant shall be applied to fill the gap between the wall and window frame for a leak-proof installation and complete finish etc., Complete and as directed by the department officers. |
| 17 | Supplying and fixing Medium Density Fibre board (SBG I) of exterior grade of following type with thickness conforming to IS 12406 / 2003 with necessary adhesive and C.P. screws, including fixing of aldrops, tower bolts, hinges and lock strike plates, putty, fevical, varnish for T.W. lipping with thinner colouring agent etc.,The rate includes cost of materials and cost for furniture fittings such as 3 nos SS 304 Grade Parliament inges of required Size (125mm x 150mm), 1 no Alu. aldrop 250 x 16mm, 2no Alu. tower bolt of 300x12mm and 1 no Alu. tower bolt of 200x12mm, 2 Nos Alu. Handles, 1 no door stopper with rubber bush incase of Single leaf door, cost of labour charges for fixing in position etc., complete. All Aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1968 for anodic film thickness of not less than 15 microns, The rate is inclusive cost of fevical and fixing charges, transportation, loading, unloading and all other incidential charges, handling charges etc., complete complying with standard specification and as directed by the departmental officers -Single leaf. |
| 18 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 19 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 20 | Plastering with Cement Mortar 1:4 (One cement and Five Plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmenta |
| 21 | Paving the floor with Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 22 | Finishing the top of roof with one course of machine pressed tiles of following size ofapproved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 23 | Paving the floor with fine polished cuddapah stone slab of following thickness over cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer and pointing the joints to full depth of slabs with same mortar mixed with black oxide and the top surface rendered smooth, curing, etc.,complete complying with standard speicification and as directed by the departmental officers. (The cuddapah stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) - Cuddapah Slab (25mm Thick) |
| 24 | Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m |
| 25 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors |
| 26 | Supplying and fixing 110mm Dia PVC Pipe |
| 27 | Supplying and fixing 110mm ø PVC Elbow |
| 28 | Supplying and fixing 110mm ø PVC Tee |
| 29 | 40mm PVC pipe |
| 30 | 15mm PVC pipe |
| 31 | 40mm PVC Coupling |
| 32 | 40mm PVC Elbow |
| 33 | 15mm PVC Elbow |
| 34 | 15mm PVC TEE |
| 35 | 40mm PVC TEE |
| 36 | 40 x 15mm PVC Elbow |
| 37 | 15mm PVC Tap |
| 38 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good for PVC Open light point / Fan point (For Electronic regulator) etc, complete as per standard specifications. SD 22 |
| 39 | Wirinng with 2x1.5sq.mm (22/0.3) PVC insulated SC. unsheathed Cu.Conductor of 1100V garade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150x100x113mm TW switch box for 5A 3 pin non inter locking wall socket with 5A Flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC Plug point. (SD36) |
| 40 | 16A MCB |
| 41 | 40A isolator |
| 42 | Supply and 2 run of 6 sqmm wire for service connection including cost and conveyance of all materials and labour charges to site etc. complete (P.115.12.0) SD. 58 |
| 43 | Supplying And Fixing LED Tube light |
| 44 | Bulk head Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender