Tender For Replacement / Repair / Maintenance Of Sign Boards, Display Boards, Street Light, Schematic Diagrams And Misc Work Of Various Pump House In The Area Of Age (U) Water Supply No. 1 Under Ge (U) Water Supply Delhi Cantt -10
Tender Overview
Project Description
Tender for Replacement / Repair / Maintenance Of Sign Boards, Display Boards, Street Light, Schematic Diagrams And Misc Work Of Various Pump House In The Area Of Age (U) Water Supply No. 1 Under Ge (U) Water Supply Delhi Cantt -10
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 metre depth and getting out in any type of soil for taking out/laying of pipe complete all as specified and as directed |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 3 | Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed. |
| 4 | Material and labour for fabrication, welding and fixing of MS works of any sizes of angles irons/flat iron/MS sheet works for valve pit cover, ladder, Sump Manhole Cover, Grills and stair steps etc including painting two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 5 | Supply and Fixing in replacement of CI Foot valve of following size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes all as specified and directed by Engineer-in-Charge. Note :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items. |
| 6 | 80 MM bore |
| 7 | 100 MM bore |
| 8 | 150 MM bore |
| 9 | S&F in replacement, butterfly valve with all necessary fittings including taking down old unservicable butterfly valve of following sizes all as specified and directed by Engr-in- Charge. |
| 10 | 80 MM bore |
| 11 | 100 MM bore |
| 12 | 150 MM bore |
| 13 | Supply and installation of flanged ends Water Meter of following sizes ISI marked woltman type, Class 'B' and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, complete all as specified and directed. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 14 | 80 MM bore |
| 15 | 100 MM bore |
| 16 | 150 MM bore |
| 17 | 200 MM bore |
| 18 | Material and labour including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS:14846 flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified . |
| 19 | 80 MM bore |
| 20 | 100 MM bore |
| 21 | 150 MM bore |
| 22 | 200 MM bore |
| 23 | Supplying , laying , jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal / Vertical / inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following size including taking out the old unserviceable pipes. (Note:- MS Flanges incl fabrication work will be measured and paid separately.) |
| 24 | 80 MM bore |
| 25 | 100 MM bore |
| 26 | 150 MM bore |
| 27 | 200 MM bore |
| 28 | Supply and fixing in replacement of MS flange 80 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasket joint of size 100mm size. |
| 29 | Supply and fixing in replacement of MS flange 100 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasket joint of size 100mm size. |
| 30 | Supply and fixing in replacement of MS flange 150 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasket joint of size 150mm size. |
| 31 | Supply and fixing in replacement of MS flange 200 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasket joint of size 200mm size. |
| 32 | Supply and fixing in replacement of MS flange 250 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasket joint of size 200mm size. |
| 33 | M&L Boring holes under road pavement by bocky manually in any type of soil upto 250 mm bore complete all as specified and directed by Engr-in-Charge. (Note:-Location & depth of trenchless boring is as directed by EIC. |
| 34 | Taking up CI/GI/Nidhi/DI/MS Pipes including all fitting of the following sizes as specified and directed by Engineer-in-Charge :- |
| 35 | 100 MM bore |
| 36 | 150 MM bore |
| 37 | 200 MM bore |
| 38 | Supply, laying jointing, testing DI pipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work & rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes including taking down of existing CI/DI pipe complete all as specified and directed by Engineer-in-Charge. (Note : (i) Excavation & earth work shall be measured & paid separetely under respective items of BOQ.(ii) Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.(iii) DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV's, MTC & e-way bill will produced by contractor during payment of 1s RAR as material laying at site.(iv) Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.(v) Layout plan for laying of DI pipe shall be given by EIC in writing. |
| 39 | 100 mm bore |
| 40 | 150 mm bore |
| 41 | 200 MM bore |
| 42 | Material and labour for Cast iron bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (both all sockets or socket and spigot or flanged) collars, cast Iron connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore. |
| 43 | Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 150 mm dia bore. |
| 44 | Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of following size/bore :- |
| 45 | 100 MM bore |
| 46 | 150 MM bore |
| 47 | 200 MM bore |
| 48 | Taking up old GI steel tubing with connection including fittings all as specified and as directed by Engineer-in-Charge of the follwing sizes :- |
| 49 | 25 MM bore |
| 50 | 40 MM bore |
| 51 | 50 MM bore |
| 52 | Supply & Laying of GI pipe mediun grade ISI mark including all fittings in old/new positions in trenches/wall/floor complet and making good the distributed surfaces as per existing as directed of following sizes. Excavation and earth work will be measured and paid separately. |
| 53 | 25 MM bore |
| 54 | 40 MM bore |
| 55 | 50 MM bore |
| 56 | S&F in replacement of GI Pipe Medium grade ISI mark 80 mm dia along with all fittings laid in trenches/floor all as per exisiting and specified by Engr-in-Charge. |
| 57 | M&L for sign board made out of 2mm thick in Radium Paint sheet steel of size 1200mm x 900mm x 100mm thick painted both side with over a coat of red oxide primer and writing the details as provided by the Office of AGE (U) Water Supply No.1\\" with white paint over approved painted back ground and embedded in PCC 1:3:6 type C2 of 30cmx30cm x 30 cm at 2 mtr height above ground level complete with stainless steel pipe of 40 mm including taking down old unserviceable sign board complete all as specified and directed by Engr-in-charge. |
| 58 | M&L of ditribution diagram of pipeline network including showing of all Pumps, Headers, Valves and pipeline of different sizes etc comprising of printing of complete distribution diagram on Vinyl sheet, weather proof and pasting the same on bakelite sheet min 3 mm thick as per existing site fixed on MS frame cover with Al sheet proper color legends same at the pump house wall and including all fixing material required in replacement and taking down old unserviceable sign board complete all as specified and directed by Engr-in-charge. Note:- MS Frame shall be deemed included in quoted unit rate.. |
| 59 | M & L in replacement of Providing and filling post/frame work of stainless steel, grade 304 pipes including braces of stainless steel, plates, angle, flats, tubular sections etc including cutting, hoisting fixing with argon welding, bright finish, buffing polishing etc complete with necessary holes, nuts, bolts, caps and anchor plates of stainless steel as per design provided by Engineer-in-Charge |
| 60 | Manufacturing, supplying and installation in replacement of full cube poly carbonate micro prismatic type retro reflective boards conforming to XI of ASTM, made of 4mm thick substrate of aluminum composite panel having 0.50mm thick skin of aluminum both side. The front side is to covered with full cube poly carbonate prismatic reflecting sheeting conforming to proposed type XI of ASTM with coloured scheme, including subject matter, message (bi-lingual), symbol and borders etc as per IRC 67-2001. The aluminum composite panel shall be suitably fixed on top, bottom and sides of stainless steel frame work as per directions of Engineer-in Charge. Retro reflective tape shall be of brand : 3M, Avery Denni & including taking down old unserviceable board complete all as specified and directed by Engr-in-charge.Note:- Design/pattern shall be approved by Engr-in-charge. |
| 61 | M&L of Display board for machinery items like Pumpset capacity equipment details including showing of sump capacity and motor ratings etc as per Engr-in-Charge comprising of printing of complete on Vinyl sheet, weather proof and pasting the same on bakelite sheet min 4 mm thick and its rounded by Al streep and provide hook to hang on wall by Stainless steel screw as per existing site including all fixing material required in replacement and including taking down old unserviceable board complete all as specified and directed. |
| 62 | M&L Machine pressed precast concrete interlocking paverblocks any shape and size confirming to IS 15658-2006 of 25 mm thick, M-35 Grade with grey cement and pigments, over 25 mm thick sand cushioning complete all as specified and as directed. Note : Sand Cushioning shall be measured and paid under respective item. |
| 63 | M&L for spread fine river sand in trenches complete all as specified and as directed. |
| 64 | M & L for surface dressing of site not exceeding 45 cm deep by mechnical means (JCB/Hydra) removal of excavated soil,raw material from site to a distance not exceeding 200 meter away and depositing where directed at a level not exceeding 0.5 meter above the starting point,pruning as direted by Engr-in-charge. |
| 65 | Material and labour for PCC 1:4:8 Type D2 using 40 mm graded aggregate as in foundations, filling and mass concrete. |
| 66 | M&L for preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with two coats of Aluminium paint upto 6 meter long and exposed surface of Pole, Yellow and Black paint in strips of alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole numbers with paint complete all as specified and directed. |
| 67 | M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 25×4mm as earthing lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. |
| 68 | Supplying and laying XLPE insulated, armoured heavu duty electric cable with aluminium conductor 1100 Volts grade cross sectional area 25 Sqmm 3.5 Core laid in trenches/floor/wall incl taking out old unserviceable cable and connection to panel for incoming and outgoing using suitable aluminium lugs complete all as specified. |
| 69 | Supplying and laying XLPE insulated, armoured heavu duty electric cable with aluminium conductor 1100 Volts grade cross sectional area 35 Sqmm 3.5 Core laid in trenches/floor/wall incl taking out old unserviceable cable and connection to panel for incoming and outgoing using suitable aluminium lugs complete all as specified. |
| 70 | Supply , installation, commissioniong and testing of soft starter suitable for motor capacity 50 HP 3 phase 415 Volts 50 Hz with Compact design, with built-in bypass contactor, Essential motor protection, Selectable soft starting profiles, Flexible communication options, Excess start time settling including taking down old starter and related accessories complete all as specified and directed. |
| 71 | Supply & Fixing in replacement for fixing of FASD Starter ML series Suitable for Upto 50 HP Motor existing location complete all as specified and as directed at site by the Engineer-in-Charge. |
| 72 | Supply & Fixing in replacement for fixing MCCB's following sizes in existing location complete all as specified and as directed at site by the Engineer-in-Charge. |
| 73 | MCCB 32 Amps 3 Pole 16 KA |
| 74 | MCCB 63 Amps 3 Pole 16 KA |
| 75 | MCCB 100 Amps 3 Pole 16 KA |
| 76 | M&L for painting fo LT panel of sqmtr not less than 20 sqmtr by spraying two coats of enamel based weather proof paint of ivory/Red over a coat of red oxide primer after cleaning of rusty panel surface of both inside/outside by emery paper and necessary preparation of old steel surface complete all as specified and as directed. |
| 77 | M&L for painting fo LT panel of sqmtr not less than 10 sqmtr by spraying two coats of enamel based weather proof paint of ivory/Red over a coat of red oxide primer after cleaning of rusty panel surface of both inside/outside by emery paper and necessary preparation of old steel surface complete all as specified and as directed. |
| 78 | M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris all as directed by the Engineer-in-Charge. |
| 79 | Supply and laying of DWC HDPE pipe, ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket,bend,couplers etc confirming to IS 14930, part-II complete with fitting cutting,jointing etc of size 50 mm outer dia complete all as specified and directed by Engr-in-Charge. |
| 80 | M&L for providing and fixing earth continuity strip/main earthing lead with 25x3mm galvanised iron(GI) strip, fixed on wall, batten, recess, chase, buried in ground, drawn in conduit/pipe or fixed to poles as required for loop earthing complete as per specifications. |
| 81 | M&L for providing and fixing earth continuity conductor/main earthing lead with 4mm dia galvanised iron(GI) wire, fixed on wall, batten, recess, chase, buried in ground, drawn in conduit/pipe or fixed to poles as required for loop earthing complete as per specifications. |
| 82 | Supply & fixing , install testing and commissioning of LT panel ,outdoor type cubical shape,three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 2.00 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs ,spreader terminals etc .(a) Cu bus bar with PVC sleeve suitable for 400 amps for phase & 200 Amp for neutral - 01Set.(b) Voltmeter,digital type 0- 500 volt,with selector switch - 01 set make: DIP/AE/IMP/NSD(c) Ammeter Digital type 0-100Amps, with selector switch and CT' - 04 set make: DIP/AE/IMP/NSD(d) Phase indicating lamps LED type ( red , yellow, blue) 01 set and ON/OFF Indicator -04 sets(e) Incoming MCCB 400 Amp 4 pole 36 KA - 01 No (f) outgoing MCCB 160 Amp 3 pole 36 KA -04 Nos (h) FASD Starter ML-3 without MS sheet enclosure -04 Nos (k) Outgoing MCB SPN 20 Amp , 230 Volts 10 KA -01 Nos (l) Outgoing MCB SPN 10 Amps, 230 Volts 10 KA- 01 Nos |
| 83 | Supply, installing, testing and commissioning factory made and tested (prototype having been CPRI type test certified), LT feeder pillar box (KIOSK), Indoor type and double door with buckled type bush hinges platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bars 600 Amps rating installed on procelain insulators. The panel shall be dust and vermin proof with suitable IP protection and made of 2.0 mm CRCA MS sheet for outer sheet, 5mm thick bottom sheet & 1.2mm thick for inner sheet for individual compartment of MCCB's, bus bar, apron etc. Back side compartment with enclosure duly for space out going cables with extended bus bar/strips for out going MCCB's etc and 40 x 40 x 6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front openign type with aprons for cable entry with double door shutter and locking arrangement with 2 keys, intenal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 Sqmm. (a) Incoming MCCB 400 Amp 3 pole 35 KA with adjustable thermal and fixed magnetic release -01 No(b) Outgoing MCCB 250 Amp 4-Pole 35 kA with adjustable thermal and fixed magnetic release - 01 No(c) Outgoing MCCB 160 Amp 4-Pole 35 kA with adjustable thermal and fixed magnetic release - 02 No(d) Outgoing MCCB 125 Amp 3-Pole 18 kA with adjustable thermal and fixed magnetic release - 02 No(e) Voltmeter,digital type 0- 500 volt,with selector switch - 01 set (f) Ammeter Digital type 0-100Amps, with selector switch and CT -1 Set (g) Phase indicating lamps LED type ( RYB) 01 Set |
| 84 | Demolition of brickwork or stone/Boulder masonry built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles etc complete all as specified and as directed. |
| 85 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6M mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 86 | M&L for brick work in CM 1:4 using bricks obtained from dismantling item No 39 here-in-before Complete all as specified and as directed. |
| 87 | Disconnecting the electric connection of monoblock pump of capacity up to 10 HP and removing the same from foundationfor repair after opening /cutting the rusted nuts, bolts etc and dismantling complete pump and repairing the same with replacing the following unserviceable spare parts i.e CI Impeller, GM shaft sleeve, Mechanical seal, water seal, water liquid reflector, MS stud with nut, gasket packing including grinding work of lathe machine and re-assembling the same including the transporting the pump from side to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and directed. |
| 88 | Disconnecting electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of any capacity and makes from base plate of pump set after opening the nuts, bolts etc / Dismantling the induction/Submersible motor and seperate the stator and rotor and removing the Unserviceable DE & NDE sede bearing, burnt winding wire from stator and rewinding the same as per existing supper enamelled copper wire gauge F class insulation used including varnishing and heating for drying of winding, transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and directed . |
| 89 | Supply and Fixing in replacement of Ball Bearing suitable for monoblock motor up to 10 HP or as per existing site. |
| 90 | Supply and fixing in replacement 45 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including making connections with GI pipe 0.6mtr angle braket fixing on wall and connectng to ceiling rose with apropriate wire complete all as specified and directed. |
| 91 | M&L for 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement plaster 1:4 all as specified and direceted. |
| 92 | An amount of Rs 1,85,957.50 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender