Drinking Water Supply and Sanitation Government Departments Closing in 5 days TDR #58352529

Tender For Annual Rate Contract For Construction Of Various Type And Size Reservoir & Pump House Under Dn. Sojat City. (Rates Are Based On Phed Revised Bsr 2023)

Issued by Government Departments · Pali, Rajasthan
Tender Value
70 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
5 days left
EMD
1.40 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pali → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Rate Contract For Construction Of Various Type And Size Reservoir & Pump House Under Dn. Sojat City. (Rates Are Based On Phed Revised Bsr 2023)

BOQ

Name of Work:- Annual Rate Contract for Construction of various type and size Reservoir & Pump House under Dn. Sojat City. (Rates are based on PHED Revised BSR 2023)
Sl. No. Item Description
1(3.2) Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e) Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.
2j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.(3.2.1) Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 18 M (3.2.1.1) 100 KL capacity
3(3.2.1.2) 150 KL capacity
4(3.2.1.3) 200 KL capacity
5(3.2.1.4) 250 KL capacity
6(3.2.4) Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M (3.2.4.1) 100 KL Capacity
7(3.2.4.2) 150 KL capacity
8(3.2.4.3) 200 KL capacity
9(3.2.4.4) 250 KL capacity
10(3.2.7) Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-II & STAGING 18 M (3.2.7.1) 100 KL Capacity
11(3.2.7.2) 150 KL capacity
12(3.2.7.3) 200 KL capacity
13(3.2.7.4) 250 KL capacity
14(3.2.10) Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 20 M (3.2.10.1) 100 KL Capacity
15(3.2.10.2) 150 KL Capacity
16(3.2.10.3) 200 KL Capacity
17(3.2.10.4) 250 KL Capacity
18(3.2.13) Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 20 M (3.2.13.1) 100 KL Capacity
19(3.2.13.2) 150 KL Capacity
20(3.2.13.3) 200 KL Capacity
21(3.2.13.4) 250 KL Capacity
22(3.2.16) Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-II & STAGING 20 M (3.2.16.1) 100 KL Capacity
23(3.2.16.2) 150 KL Capacity
24(3.2.16.3) 200 KL Capacity
25(3.2.16.4) 250 KL Capacity
26(3.2.19) Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 22 M (3.2.19.1) 100 KL Capacity
27(3.2.19.2) 150 KL Capacity
28(3.2.19.3) 200 KL Capacity
29(3.2.19.4) 250 KL Capacity
30(3.2.22) Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 22 M (3.2.22.1) 100 KL Capacity
31(3.2.22.2) 150 KL Capacity
32(3.2.22.3) 200 KL Capacity
33(3.2.22.4) 250 KL Capacity
34(3.2.25) Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-II & STAGING 22 M (3.2.25.1) 100 KL Capacity
35(3.2.25.2) 150 KL Capacity
36(3.2.25.3) 200 KL Capacity
37(3.2.25.4) 250 KL Capacity
38(3.3) Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
39h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.(3.3.1) Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4(3.3.1.1) 50 KL capacity
40(3.3.1.2) 75 KL capacity
41(3.3.1.3) 100 KL capacity
42(3.3.1.4) 150 KL capacity
43(3.3.1.5) 200 KL capacity
44(3.3.1.6) 250 KL capacity
45(3.3.1.7) 300 KL capacity
46(3.3.2) Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4(3.3.2.1) 50 KL Capacity
47(3.3.2.2) 75 KL capacity
48(3.3.2.3) 100 KL capacity
49(3.3.2.4) 150 KL capacity
50(3.3.2.5) 200 KL capacity
51(3.3.2.6) 250 KL capacity
52(3.3.2.7) 300 KL capacity
53(3.4) Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. .b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.
54k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.(3.4.1) Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE2,3 & 4(3.4.1.1) 400 KL Capacity
55(3.4.2) Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE2,3 & 4(3.4.2.1) 400 KL Capacity
56(3.4.3) Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.(3.4.3.1) 500 KL Capacity
57(3.4.4) Rates for RCC Partially Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC ZONE-2 & 3.(3.4.4.1) 500 KL Capacity
58(3.4.7) Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.(3.4.7.1) 500 KL Capacity
59(3.4.8) Rates for RCC Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC ZONE- 2 & 3(3.4.8.1) 500 KL Capacity
60(3.5) Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work.c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir.
61m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.(3.5.1) Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm(3.5.1.1) 50 KL Capacity
62(3.5.1.2) 100 KL capacity
63(3.5.1.3) 150 KL capacity
64(3.5.1.4) 200 KL capacity
65(3.5.1.5) 250 KL capacity
66(3.5.1.6) 300 KL capacity
67(3.5.1.7) 400 KL capacity
68(3.5.1.8) 500 KL capacity
69(3.6) Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. (3.6.1) 50 mm
70(3.6.2) 65 mm
71(3.6.3) 80 mm
72(3.6.4) 100 mm
73(3.7) Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. (3.7.1) 100 mm
74(3.7.2) 150 mm
75(3.7.3) 200 mm
76(3.7.4) 250 mm
77(3.7.5) 300 mm
78(3.7.6) 350 mm
79(3.7.7) 400 mm
80(3.7.8) 450 mm
81(3.7.9) 500 mm
82(3.7.10) 600 mm
83(3.7.11) 700 mm
84(8.1) Construction of Pump house of brick/ stone masonry of required size suitable for installation of maximum 4 no. Monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.Rate is exclusive of GST.
85(8.2) Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonry in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonry and cement mortar plaster 20 mm thick on brick masonry in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done.Rate is exclusive of GST.
86(8.3) Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints.Rate is exclusive of GST. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58352529
AUTHORITY Government Departments
TENDER VALUE 70 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Annual Rate Contract For Construction Of Various Type And Size Reservoir & Pump House Under Dn. Sojat City. (Rates Are Based On Phed Revised Bsr 2023)
Basic Detail
Tender No NIT No. 93/2026-27
Bidding Type Tender
Location
City Pali
State Rajasthan
Key Dates
Publish Date 03 Nov 2026
Submission Date 17 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value 70 Lakhs
Tender Fee 5000
EMD 1.40 Lakhs
Exemption Available
Document List
5573b9bb-9bbf-431d-ac08-7ebaac2d06e1.html
BOQ_1073471.xls
TD-93.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

5573b9bb-9bbf-431d-ac08-7ebaac2d06e1.html

xls

BOQ_1073471.xls

pdf

TD-93.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender