Tender For Proposed Construction Of Hostel Buildings For Girls Studying In The Government Residential Schools In The State Belonging To Scheduled Castes And Neo-Buddhists, Under Social Justice And Special Assistance Department, Government Of Maharash
Tender Overview
Project Description
Tender for Proposed Construction Of Hostel Buildings For Girls Studying In The Government Residential Schools In The State Belonging To Scheduled Castes And Neo-Buddhists, Under Social Justice And Special Assistance Department, Government Of Maharashtra (Including Electrical Work) At Pali Raigad And Rajgurunagar Pune Districts.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Providing and fixing board displaying information, such as \\"Name of work, Tender cost,Name of Contractor, Work completion and liability period etc\\", having rectangular shape of 1.80m x 1.20m size made up of 4 mm aluminum composite pannel sheet with 0.5 mmskin thickness on either side bonded with white retro reflective sheeting of Class C (TypeXI Micro prismatic grade sheeting) having pressure sensitive adhesive. Retro reflective sheeting with specified background, border and back side reto reflective symbols, letters,numerals, arrow as per IRC: 67-2012 Table No 8.3, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly paintedincluding Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long paintedwith alternate black and white bands of 25 cm width including all fixtures etc.and fixingthe boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation,refilling, transportation, and labour etc complete. Class _C_ (Type XI Micro prismaticgrade sheeting)) shall have 10 years written warranty from the manufacturer including theDigitally Printed areas with approved printing technology with sheeting manufacturerapproved inks and laminated with UV overlay film and this warranty certificate in originalshould be submitted to the Engineer in charge by the contractor/supplier. |
| 3 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means [Bd.A.1 Page No. 259]Excavtion In soil (Lift upto 1.5 m) |
| 4 | Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Lift from 1.5 m to 3.0 m.) By Mechanical MeansExcavtion In soil (Lift from 1.5 m to 3.0 m) |
| 5 | Excavtion In soil (Lift from 3.0 m to 4.5 m) |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. for 50 Km Lead. |
| 7 | Providing preconstructional antitermite treatment as per S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyri fos per square meter surface area covering 10 years guarantee on bond paper. Spec. As directed by Engineer in charge. |
| 8 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. As directed by Engineer in charge. |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Bd.E.4 Page Number 289 and B- 7, Page Number38)GROUND FLOOR |
| 10 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.GROUND FLOOR |
| 11 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 13 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 14 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) [Bd.J.2 Page No. 355] |
| 15 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)First Floor |
| 16 | SECOND floor |
| 17 | TERRACE floor |
| 18 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) [Bd.J.2 Page No. 355] |
| 19 | Providing and fixing in position HCRM/CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pilecaps, footings, foundations, slabs, beams, columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins,arches etc. as per detailed designs,drawings and schedules including cutting, bending, hooking the bars,binding with wires or tack welding and supporting as required complete.GR FLOOR |
| 20 | First floor |
| 21 | second floor |
| 22 | Terrace Floor |
| 23 | ABOVE Terrace Floor |
| 24 | Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Upto 1st Floor |
| 25 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap /granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, stripfoundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns asper detailed designs and drawing or as directed including Steel centering formwork,cover blocks laying/pumping, compaction finishing the formed surfaces with cementmortar 1:3 of sufficient minimum thickness to give a smooth and even surface orroughening if special finish is to be provided and curing etc. complete. (Excludingreinforcement and structural steel). with fully automatic micro processor based PLCwith SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 26 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap /granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing oras directed including steel centering, formwork,cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness togive a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). withfully automatic micro processor based PLC with SCADA enabled reversible Drum Typemixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade)GR FLOOR |
| 27 | First floor |
| 28 | Sec Floor |
| 29 | Terrace Floor |
| 30 | ABOVE Terrace Floor |
| 31 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap /granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs anddrawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compactionand roughening the surface if special finish is to beprovided and curing etc. complete. (Excluding reinforcement and structural steel).withfully automatic micro processor based PLC with SCADA enabled reversible Drum Typemixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade)GR FLOOR |
| 32 | First floor |
| 33 | Sec Floor |
| 34 | Terrace Floor |
| 35 | Above Terrace Floor |
| 36 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designsand drawings including steel centering, formwork, cover blocks, laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimumthickness to give a smooth and even surface or roughening if special finish is tobe provided and curing etc. complete,(Excluding reinforcement and structuralsteel).with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fineaggregate (Crushed sand VSI Grade)GR FLOOR |
| 37 | First floor |
| 38 | Sec Floor |
| 39 | Terrace Floor |
| 40 | ABOVE Terrace Floor |
| 41 | Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including precast concrete cover blocks of same or Higher Grade. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) [Bd. F. 13 Page No. 305 /I.S. 456 (2000)]GR FLOOR |
| 42 | First floor |
| 43 | SECOND Floor |
| 44 | TERRACE Floor |
| 45 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / granite/gneiss / quartzite metal for R.C.C. fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ground floor |
| 46 | First floor |
| 47 | Terrace Floor |
| 48 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)GR FLOORTerrace Floor and compound wall |
| 49 | First floor |
| 50 | SECOND Floor |
| 51 | TERRACE Floor |
| 52 | Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete |
| 53 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. [Bd.A.11 Page No. 263] |
| 54 | Providing and fixing double scaffolding system (cuplocktype) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site,mad with 40mm dia M.S.tube,placed 1.5 metre centre to centre,horizontal&vertical tube sjoint with cup& lock system with M.S.Tubes,M.S.tube challis,M.S.clamps and staircase system in the scaffolding for working platform etc.and maintaining it in a serviceable condition for execution of work of cleaning and/or pointing and/ or applying chemical and removing it thereafter.The scaffolding system shall be stiffened with bracings, runners,connecting with the building etc,wherever required,if feasible,for inspection of work at required locations with essential safety features for the work men etc.,complete as per directions and approval of Engineer-in-charge.Note:-(1)The elevational area of the scaffolding shall be measured for payment purpose.(2)The payment will be made once only for execution of all items for such works.Gr Floor |
| 55 | First Floor |
| 56 | Second Floor |
| 57 | Terrace Floor |
| 58 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Gr Floor |
| 59 | First Floor |
| 60 | Second Floor |
| 61 | Terrace Floor |
| 62 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Gr Floor |
| 63 | First Floor |
| 64 | Second Floor |
| 65 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. As directed by Engineer in ChargeGr Floor |
| 66 | First Floor |
| 67 | Second Floor |
| 68 | Terrace Floor |
| 69 | Providing internal / external 12 mm thick Ready Mix plaster confirming to IS:4031 (Part-4) 1988 and IS383 -1970 in a single coat using Cement mortar of proportion 1:4 containing special type of polymer additives about 0.4%, to all type of surfaces in all positions including scaffolding and curing complete. As directed by Engineer InchargeGr Floor |
| 70 | First Floor |
| 71 | Second Floor |
| 72 | Terrace Floor |
| 73 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Gr Floor |
| 74 | First Floor |
| 75 | Second Floor |
| 76 | Terrace Floor |
| 77 | Providing and applying Texture plaster with finishing with texture material ofapproved make in 3 to 4 millimeter thickness on previously plastered surface, includingPlaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or asrequired, in all position including preparing the surface, scaffolding etc. completeGr Floor. |
| 78 | First Floor |
| 79 | Second Floor |
| 80 | Terrace Floor |
| 81 | Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.Gr Floor |
| 82 | First Floor |
| 83 | Second Floor |
| 84 | Terrace Floor |
| 85 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Gr Floor |
| 86 | First Floor |
| 87 | Second Floor |
| 88 | Terrace Floor |
| 89 | Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. (Bd.O.8/Page Number406)SSR 22-23 / Item No. 35.15/ Pg 224 |
| 90 | First Floor |
| 91 | Second Floor |
| 92 | Terrace Floor |
| 93 | Providing and fixing false ceiling with eco-friendly light-weight calcium silicatetiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mmhaving 15mm thick densified micro look edge and 100% humidity resistanceincombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC0.50 placed in true horizontal level suspended grid of size 600x600mm made fromhot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbedwhite with 6mm reveal profile (white/black), wherein, main T runner of size42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the firstcrossed T in each panel to form grid of 1200mmx600mm resting on periphery wallProfile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceilingfor services like diffusers grills including cutting, making opening for light fittings,fixtures, , smoke detectors etc., wherever required. Main T runners suspended fromceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to theceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rodswith powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mmspaced @1200, center-to- center along main T all complete at all heights as per thespecifications, drawings and as perGROUND FLOOR |
| 94 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vIrgin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. As directed by Engineer in chargeGr floor |
| 95 | First Floor |
| 96 | Second Floor |
| 97 | Providing and applying two coats of protective membrane over the cured concrete surface like R.C.C. footings, columns, plinth beams etc. which will be submerged under soil so as to protect the same. Apply two pack coal tar epoxy system of Sunepoxy Coaltar of approved make & approved by Engineer in charge, having solid content ranges from 80-100%, Tack free time 4-6 hrs. Recoat after 16-24 hrs. Mix Part A and Part B of Sunepoxy Coaltar of approved make & approved by Engineer in charge in 1:1 ratio with slow speed stirrer and apply the same on a clean R.C.C. surface by brush. Allow to set for 8-10 hours and apply the second coat. The rate to include for application at all levels to various RCC elements to the satisfaction of the EIC etc. complete.GROUND FLOOR |
| 98 | Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)Gr Floor |
| 99 | First Floor |
| 100 | Second Floor |
| 101 | Providing and laying waterproofing treatment of 112 mm average thickness consisting of 12 mm thick layer in cement mortar 1 : 4 with water proofing compound at the rate of 1 kg per bag of cement as base, constructing and laying brick bat coba in cement mortar 1:5 with waterproofing compound at the rate of 1 kg per bag of cement and having average thickness of 80 mm and finishing with 2 mm thick cement plaster layer in cement mortar 1:4, aterproofing compound at the rate of 1 kg per bag of cement bag, laying in required position flooring of broken China mosaic (broken pieces of China chips) of approved colour and pattern including neat cement float, giving proper slopes, compaction, curing, finishing preparing bell mouth etc. including all lead , lifts and laid to proper slope to drain off water entirely including watta, Bell head or Champhered portion at the junction of parapet and work upto a height of 300 mm or as directed and covering the whole treatmnet with yten years guarantee, on requisite stamp paper etc. complete (Spec : As directed by Engineer in charge)Terrace Water Proofing Terrace Floor |
| 102 | Providing and applying a base coat comprising of 1 KilogramPolydee-MC and 1Kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2A :1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.Gr Floor |
| 103 | Terrace Floor |
| 104 | Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer.GROUND FLOOR |
| 105 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.GROUND FLOOR |
| 106 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS.15622-2006 ( group Bla) of approved make, shade and pattern for flooring in requiredposition laid on a bed of 1:4 cement mortar including neat cement float, fillingjoints, curing and clearing etc. complete.Gr Floor |
| 107 | First Floor |
| 108 | Second Floor |
| 109 | Terrace Floor |
| 110 | Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. [Bd.M.12 Page No. 385]Gr Floor |
| 111 | First Floor |
| 112 | Second Floor |
| 113 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephoneblack / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treadsand risers of steps and staircases of approved colour and shade with full moulding andthree grooved line for the treads on bed of 1:4 Cement mortar including float fillingjoints with neat cement slurry curing polishing and cleaning etc. complete.Gr Floor |
| 114 | First Floor |
| 115 | Second Floor |
| 116 | Terrace Floor |
| 117 | Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab ofapproved quality including giving required size and shape etc. Fixing in cement mortar1:3 curing and cement etc. complete. b) Both side polishGROUND FLOOR |
| 118 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. completeGr Floor |
| 119 | First Floor |
| 120 | Second Floor |
| 121 | Terrace Floor |
| 122 | Providing and laying telephone black / Amba White / Cadbury brown / Rubyred / Ocean Brown granite stone of 18 to 20 mm thick for door frame / dado / window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges where ever necessary, curing, etc. complete. As directed by Engineer-In- ChargeGr Floor |
| 123 | First Floor |
| 124 | Second Floor |
| 125 | Terrace Floor |
| 126 | Providing and fixing machine cut and mirror polished approved coloured ITALIAN MARBLE CLADDING with inlays of approved size,20mm +2mm thk. Of approved quality for required patternon a bed of 1:4 CM 25mm average thickness including neat cement float,filling joints with neat coloured pigment, curing, polishing and cleaning etc.complete. (Basic rate of Italian marble Rs.4000/-per Sq.M) of Beige Botticino, Crema Marfil, Grey Fiasco, Spanish Grey, Light Emperador, Armani GreyGROUND FLOOR |
| 127 | Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m )Gr Floor |
| 128 | First Floor |
| 129 | Second Floor |
| 130 | Fire Door 55 mm 2HR FRL (120/120) 3 Criteria-INTEGRITY/ INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2.Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology (\\"Non Combustible by Nature\\").a) Door Frame: Supplying & Fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete.SSR 22-23 / Item No. 51.169 / Pg 399Gr Floor |
| 131 | First Floor |
| 132 | Second Floor |
| 133 | Terrace Floor |
| 134 | b)Shutter : Supplying & Fixing of 55mm thick asbestos free criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 Kilogram/cum) frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128 Kilogram/cum), vermaculite mix faced with 3mm Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping.Gr Floor |
| 135 | First Floor |
| 136 | Second Floor |
| 137 | Terrace Floor |
| 138 | c) Vision Panel:2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints.Gr Floor |
| 139 | First Floor |
| 140 | Second Floor |
| 141 | Terrace Floor |
| 142 | Panic Bar: (For 2 Hr fire Rated single Panic bar)Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style ,made of heavy duty cast iron/ steel body & latches with SS ,BHMA certified & conforming to ANSI A 156.3 for grade-1 ( 3 hours fire rated ) and suitable for surface mounting to wooden/hollow metal/ Al framed door,with maximum operating force 8Kilogram for unlocking easily & outwardly during emergency,complete in all respect as per direction & satisfaction of Engineer-in charge including all taxes & incidental charges. (Note: To be installed at \\"FIRE EXIT\\"only under location specific instruction of Eingineer-in -Charge.)Gr Floor |
| 143 | First Floor |
| 144 | Second Floor |
| 145 | Terrace Floor |
| 146 | Door Closure: (For 2 Hr fire Rated EN-3 Door Closure)Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors of different size (e.g size -EN-3 for leaf width upto 900mm) CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.) fitted and fixed Complete as per direction & satisfaction of Engineer -in Charge including all taxes & incidental charges.Gr Floor |
| 147 | First Floor |
| 148 | Second Floor |
| 149 | Terrace Floor |
| 150 | 12\\"SS Handle: (For 2 Hr fire Rated 12\\"SS Handle)Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.)as per direction of Eingineer -in Charge fitted and fixed complete including all taxes & incidental charges.Gr Floor |
| 151 | First Floor |
| 152 | Second Floor |
| 153 | Terrace Floor |
| 154 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutterGr Floor |
| 155 | First Floor |
| 156 | Second Floor |
| 157 | Terrace Floor |
| 158 | Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). |
| 159 | Terrace |
| 160 | Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS14856 (2000) (Reaffirmed 2006) without ventilator including chromium platedfixtures and fastening with chromium plated handles on both sides, etccompleteGr Floor |
| 161 | First Floor |
| 162 | Second Floor |
| 163 | Providing and fixing in position powder coated aluminium louvered windows / ventilatorof various sizes with powder coating as per detailed drawing and specificationsincluding aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheetglass louvers, of approved quality etc. complete.SSR 22-23 / Item No.39.68 / Pg 259Gr Floor |
| 164 | First Floor |
| 165 | Second Floor |
| 166 | Providing and fixing steel frame of angle 40 x 40 x 5 mm size for windows with 16 mm dia. mild steel bars horizontally at 10 cm c/c for ventilator portion and 15 cm c/c for remaining portion with M.S. flat of size 40 x 6 mm vertical at center including iron hold fast boxes for fixing 40 x 6 mm vertical at center including iron hold fast boxes for fixing shutters including welding finishing painting etc. complete.Gr Floor |
| 167 | First Floor |
| 168 | Second Floor |
| 169 | Terrace Floor |
| 170 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.GR ( 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47mm) |
| 171 | 1st Floor ( 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47mm) |
| 172 | 2nd Floor ( 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47mm) |
| 173 | Terrace ( 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47mm) |
| 174 | Providing & fixing S.S. pipe hand rail along the wall in staircase orramps or passages consisting of 50 mm dia. 18 gauge 304 grade stainless steel pipe. Supported with 25 mm 18 gauge S.S. pipe(304grade) brackets & 5mm thick tapered edge coller base plate fixedto wall with SS screws at approx. 600 mm center to center fixedhorizontally or in inclined position at required height including grindingthe welded joints, buffing,protecting the railing members by means of wrappers during construction etc. complete as per detailed drawing as directed by the Engineer in charge.Gr Floor |
| 175 | First Floor |
| 176 | Second Floor |
| 177 | Terrace Floor |
| 178 | Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete |
| 179 | First Floor |
| 180 | Second Floor |
| 181 | Terrace Floor |
| 182 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Gr Floor |
| 183 | First Floor |
| 184 | Second Floor |
| 185 | Terrace Floor |
| 186 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.Gr Floor |
| 187 | First Floor |
| 188 | Second Floor |
| 189 | Terrace Floor |
| 190 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat, scaffolding if necessary , and watering the surface for two days etc complete.Gr Floor |
| 191 | First Floor |
| 192 | Second Floor |
| 193 | Terrace Floor |
| 194 | Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system, As directed by Engineer-in-charge Gr Floor |
| 195 | First Floor |
| 196 | Second Floor |
| 197 | Terrace Floor |
| 198 | Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends,tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete.Including removing existing pipe line if necessaryFor Municipality Inlet connectionTerrace Floor |
| 199 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.For Shaft Water supplyGr Floor |
| 200 | First Floor |
| 201 | Second Floor |
| 202 | Terrace Floor |
| 203 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.For Shaft Water supplyGr Floor |
| 204 | First Floor |
| 205 | Second Floor |
| 206 | Terrace Floor |
| 207 | Providing and fixing 8 cm rigid PVC Nahani trap including PVC grating ,bend, connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)For ToiletsGr Floor |
| 208 | First Floor |
| 209 | Second Floor |
| 210 | Providing & Fixing 100mm diameter Nahani trap Jali in steel finish with necessary fixing required to make the item well functional.For Terrace,Toilet and BalconyGr Floor |
| 211 | First Floor |
| 212 | Second Floor |
| 213 | CP AND SANITARY WORKSProviding and fixing European type white glazed earthen ware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the out side face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps, 20 mm dia. UPVC over flow pipe, mosquito proof couplings G.I. chain and pulley, with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete. (prior approval of sample and brand by Ex. Engineer is necessary before use)Gr Floor |
| 214 | First Floor |
| 215 | Second Floor |
| 216 | Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall.Gr Floor |
| 217 | First Floor |
| 218 | Second Floor |
| 219 | Providing and fixing C.P. BIB cock with wall flange of approved make includingnecessary sockets/ union nut etc. complete as directed by Engineer in charge.Gr Floor |
| 220 | First Floor |
| 221 | Second Floor |
| 222 | Providing and fixing C.P. pillar cock long neck with aerator of approed makeincluding necessary sockets/union nut etc. complete.For Basin Gr Floor |
| 223 | First Floor |
| 224 | Second Floor |
| 225 | Providing and fixing toilet paper holder : C.P.Toilet paper holder jaquar make continentalFor ToiletsGr Floor |
| 226 | First Floor |
| 227 | Second Floor |
| 228 | C.P.soap dish (polyurethane) jaquar make continental (Cat. No.AQN 7733 )For Bath areaGr Floor |
| 229 | First Floor |
| 230 | Second Floor |
| 231 | Providing and fixing C.P.Two way BIB cock of approved make continentalincluding necessary sockets/union nut etc. completeGr Floor |
| 232 | First Floor |
| 233 | Second Floor |
| 234 | Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super jetspray with flange 2 in 1 faucet 1.50 metre long including all accessories etc completee For Internal ToiletsGr Floor |
| 235 | First Floor |
| 236 | Second Floor |
| 237 | Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.Gr Floor |
| 238 | First Floor |
| 239 | Second Floor |
| 240 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. completeGr Floor |
| 241 | First Floor |
| 242 | Second Floor |
| 243 | Terrace Floor |
| 244 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Gr Floor |
| 245 | First Floor |
| 246 | Second Floor |
| 247 | Terrace Floor |
| 248 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Gr Floor |
| 249 | First Floor |
| 250 | Second Floor |
| 251 | Terrace Floor |
| 252 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap |
| 253 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete. |
| 254 | RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge |
| 255 | Providing and fixing H.D.P container one piece moulded water tank made out of lowdensity polythyler and built corrugation including of delivery up to destinationhoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacityabove 1000 to 20,000 litresTerrace Floor |
| 256 | Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.Terrace Floor |
| 257 | Providing and fixing 40mm diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making lockingarrangements and lock. [Withoutchamber]. |
| 258 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flatstringers and steps of 18 mm dia. mild steel bar for water tank including fixing itin (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting theladder complete. (AntiCorossive Paint) |
| 259 | Providing and constructing granite kitchen platform with fixing of stainless steel sink600 mm x 450 mm size as per detailed drawing including vertical both side polishedkadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick andpolished granite 16 to 20 mm top with side strips of granite at front and both sides ofplatform raised with two vertical granite supports 15 cm height and top granite of75 x 40 cm including cutting, opening for sink of required size in kadappah as well asgranite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) |
| 260 | Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wallbracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware orequivalent make including all necessary pipes,fittings etc.complete as directed byEngineer In Charge.( Make shall conform to manufacturer's Green product and shall gotapproved from the Engineer In Charge.) Gr Floor |
| 261 | First Floor |
| 262 | Second Floor |
| 263 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum includingdressing section to the required grade, camber and side slopes and conveying theexcavated materials with all lifts upto a lead of 50m. and spreading for embankment orstacking as directed |
| 264 | Providing earth work in embankment with approved materials obtained fromdepartmental land upto lead of 50m. including all lifts, laying in layers of 20centimetre . to 30 centimetre . thickness breaking clods, dressing to therequired lines, curves, grades & section, watering and compaction withvibratory roller to achieve not less than 97 % of standard proctor density etc.complete ( Material obtained from departmental Land) (All Floors) |
| 265 | Excavation for catch / side water gutter in all sorts of soils to the specified sectionincluding stacking the excavated stuff in a regular bund and disposing of unsuitable orexcess stuff as directed all sorts of soils |
| 266 | Construction of granular sub-base by providing close graded Material, mixing in amechanical mix plant at OMC, carriage of mixed Material to work site, spreading inuniform layers with motor grader/ Paver on prepared surface and compacting withvibratory roller to achieve the desired density, complete as per clause 401 -- Plant MixMethod and Grading - I Material |
| 267 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-incharge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 268 | Providing and laying in-situ M35 Grade unreinforced plain cement concrete pavementwith max 20% fly Ash ( Fly-ash upto 20% by weight of Cement) over a prepared sub basewith 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washedcrushed sand) conforming to IS 383, using fine and coarse aggregates combined gradationas per Table 600-3 of MORTH Specification 2013, mixed in a Tilting type ConcreteMixer as per approved mix design, admixtures, spreading, laying compacting and finishedin a continuous operation without paver machine, finishing to lines and grades as directedby Engineer-in-charge and curing by curing compound /by providing cement vata incement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period byany other method approved by Engineer-in-charge. |
| 269 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. |
| 270 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. |
| 271 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc |
| 272 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. |
| 273 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete |
| 274 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. |
| 275 | Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level. |
| 276 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge |
| 277 | Gravel packing in tubewell construction in accordance with IS:4097, including providing gravel: fine/ medium/ coarse, in required grading & sizes as per the actual requirement, all complete as per direction of Engineer in charge. |
| 278 | FurnitureSingle Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminateGr Floor |
| 279 | First Floor |
| 280 | Sec Floor |
| 281 | Providing and supplying canter table of required size with top madeof 8mm thick clear toughened glass with bevelled edgefrom bottomedge of the glass border and vertical edgewithpolish etc. complete. Understructure made of25mm thick Marine ply (IS 710 : 2010) with all exposed edgefinishedwith 2mm thick machine pressed PVC edge banding in matchingcolour. (Rehau Make/or Equivalent) for better impact resistance.Nylon button stopper to hold glass top inposition, Nylon bushers etc.complete. |
| 282 | Providing and supplying center pivot, revolving, High back chair Depth45cm, width-50cm, height- 121cm to 131cm & seat height 45cm to55cm. (+/- 2cm) with five legged metal /moulded nylon base with pushback arrangement. Chairs shall have highdensity moulded, 360revolving on suitable base, gas lift , heavy duty twin wheel castors to take min 80 kg/castor withtwo - pneumatic height adjustment one piece moulded typepolypropylene armrest etc. complete. The chair shall be provided with approved tapestry upto Rs 300/m with necessary beading wherever required. All metal work shall beEpoxy Polyster Powder Coated and asdirected by Architect in charge. |
| 283 | Providing and supplying Modular CUPBOARD made up of required size. Top made of 25mm Marine ply (IS 710 : 2010), having post formed decorative laminate of 0.8mm on top and FIRE RETARDENT laminate on all sides / surfaces etc.complete. Sides, Sides in 25mm thk Marine ply (IS 710 : 2010). Adjustable shelf made in 25mm thk Marine ply (IS 710 : 2010) placed on standard shelf pins etc. complete. Storage Back made of 9mm thick Marine ply (IS 710 : 2010)etc. Sides, Shutters, Bottom, adjustable shelf, finished 2mm thick machine pressed PVC Edge banding of required size etc. Hardware set to include 110 degree opening self- closing box hinges, Counter Sunk screw, S.S.Brush Finished, Handles L’ Clips Selves support etc. complete. Multipurpose lock, Levelling Bolt with inserts etc. complete. Aluminium furniture feet – Round tube, diameter 40 mm with 100 mm height with suitable finish to match handles’' Shape SS Brush finished handles as indicated in the drawing, suitable locking provision etc. complete. |
| 284 | Providing & fixing premium quality Roller blinds with prestressSolar protection fabric of high tenacity Polyester Yarn with PVCcoating and fungi static treatment and should block the light flux& offer elimination of glare and sunlight /radiance etc.complete. Fabric shall have visible light & solar properties &Greengard (gold) Indoor Air quality& children & school certified.Fabric composition - 39% Polyester / 61% PVC with alumium backing. Weight - 290 g/sq.m (+/- 5%) Thickness - 0.32 mm (+/- 5%) Fabric openness factor - 3% Tensile strength (warp / weft) - 160/170 daN/5cm Tearing Strength (warp/weft) - 11/13 daN Backing - Aluminium backing. Fungi static treatment - Degree 0 Excellent (EN ISO 846-A) Fire retardancy: B-s2,d0/EN 13501-1, class A/ASTM E8 |
| 285 | Providing and fixing SS (IS 6911:1992) grade of steel 304 Dinning chirsfor dining Hall and dining Room area as per the drawing or approvedsize and shape including all lead lift shiftingto work location etc.complete. |
| 286 | Providing and Fixing Dining table of Overall S.S (IS 6911:1992),grade of steel 304, Thickness of the table is 40 mmStructure top to be Of s.s 18 SWG 304,Grit. Under Structure to be Vertical poles of 50 mm Dia (16 gauge 304 grade) and top and Bottomsupporting frame Structure to be 50 x 50 mm Square tube etc. complete. Glide shall be of Plastic fixed at the under structure to prevent the damage of table top during stacking. Legs shall be of SS and 38 mm dia (16 gauge 304 grades). pipe legs are fixed with under structure and table top etc. complete. |
| 287 | Wardrobe with Mirror @ 900LX 600DX 1965H Providing and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required.Gr Floor |
| 288 | First |
| 289 | Providing and Fixing stainless steel kitchen trolley of overall 26 \\" height and 22\\" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 \\" x 20 \\" x 22 \\" on both sides of trolley of 12 \\" or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)Gr Floor |
| 290 | Providing and supplying visitor chair having size Depth- 62cm,width-55cm, height-80cm & seat height 45 cm. (+/- 2cm ), having seat & back, shall be made up of 1.2 cm hot pressed plywood, approved tapestry upto Rs.300/m and mould polyurethane foam with P.V.C. lipping all around etc. complete. The chair shall be provided with two one piece armrest made of polypropylene. The chair shall besupported by cantilever type powder coated tubular frame dia 2.54cm x 14B G M.S.E.R.W. tube. All aluminium steel component shall have Epoxy Polyster Powder Coated. The chair shall be Ergonimc Dry film thickness shall be more than 45 Micron. And as directed by Architect in charge. The over all appearance of the product shall be as per photograph. All metal work shall be Epoxy Polyster Powder Coatedand as directed by Architect in charge. |
| 291 | Providing & Fixing in position, Acoustical Panelling made from Fabric wrappedCompressed polyester fibre nonwoven 9 mm panels on, 50 x 50 mm sal-wood frame of600 x 600 c to c having wooden supports from wall of required length, in front of 1000gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete |
| 292 | ELECTRICAL WORKS |
| 293 | Supply,installation, testing & commissioning etc. of DG set panel Construction- Floor mounted cubicle type panel, Fabricated from 14/16G CRCA ,IP52 sheet steel totally compartmentalized, treted for rust proofing. with separate busbarcamber & cable chambers Front/ back access for switchgears, connectors etc. Suitable for 430 V, 3 phase / 4 Wire System , 50 Hz supply, ALL LT PANELS ARE TYPE TESTED - IP-52 RATING Breakers shall be compitable to monitored through' IBMS] The Energy multifunction meter with RS 485/RS232 port shall be provided as per SLD PANEL BUILDER Control Unit/ Incomer- 1 No. - 250A MCCB, 25kA, FP /MP with O/C,S/C,E/F,U/V, E/L and Shunt coils etc. LED Based Phase indicating lamps, control MCBs , CTs, etc Set - ON/OFF/ TRIP lamps with control MCBs Set - ON/OFF/ TRIP lamps with control MCBs, (BMS COMPATIBLE METER ) Potential Bus/Busbar 1 set - 630A TPN+E Tinned Aluminium busbar,Insulated with heat shrinkable sleeves Feeder section/Outgoing : HOSTEL LIGHT POWER PANEL -1 No. -- 250A TPN MCCB 16kA, TPN /TM with O/C,S/C,E/F, FAS PA PANEL -1 No. -- 63A TPN MCCB 16kA, TPN / TM with O/C,S/C,E/F SPARE -63A TPN MCCB 16KA TPN / MP with O/C,S/C,E/F As directed by Engineer in charge, |
| 294 | Supply,installation, testing & commissioning etc. of LT panel HOSTEL LIGHT/POWER PANEL Construction- Floor mounted cubicle type panel, Fabricated from 14/16G CRCA ,IP52 sheet steel totally compartmentalized, treted for rust proofing. with separate busbarcamber & cable chambers Front/ back access for switchgears, connectors etc. Suitable for 430 V, 3 phase / 4 Wire System , 50 Hz supply, Control Unit/ Incomer- 1 No. - 250.A MCCB, 25kA, FP /MP with O/C,S/C,E/F,U/V, E/L and Shunt coils etc. LED Based Phase indicating lamps, control MCBs , CTs, etc Set - ON/OFF/ TRIP lamps with control MCBs Set - ON/OFF/ TRIP lamps with control MCBs, (BMS COMPATIBLE METER) Potential Bus/Busbar 1 set - 630A TPN+E Tinned Aluminium busbar,Insulated with heat shrinkable sleeves Feeder section/Outgoing : Feeder section/Outgoing : 1 No. -- 125A TPN MCCB 10kA, 5 Nos. -- 80A TPN MCB 10kA, 2 Nos. -- 63A TPN MCB 10kA, 4 Nos. -- 40A TPN MCB 10kA, 2 Nos. -- 32A TPN MCB 10kA, 1 No. -- 25A TPN MCB 10kA, As directed by Engineer in charge |
| 295 | Supply,installation,testing & commissioning of APFCR PANEL (100KVAR) Construction- Floor mounted cubicle type panel, IP 52 Enclosure Fabricated from 14/16G CRCA sheet steel totally compartmentalized, treted for rust proofing with separate busbarcamber & cable chambers, Front/back access for switchgears, connectors etc.Suitable for 430 V, 3 phase / 4 Wire System , 50 Hz supply Main Control Unit/ Incomer Suitable rating ACB EDO/ MCCB, TM/MP, FP/TPN O/C,S/C,E/F,U/V and shunt coils as required Breakers shall be compitable to monitored through' IBMS], LED Based Phase indicating lamps, control RCBOs , CTs, etc Set - ON/OFF/ TRIP lamps with control RCBOs Potential Free Contacts for Remote Monitoring The Energy multifunction meter with RS 485/RS232 port shall be provided as per SLD,Main Control Unit/ Incomer 1No. - 160A MCCB EDO,50 kA,FP/MP O/C,S/C,E/F,U/V and LED Based Phase indicating lamps, control RCBOs , CTs, etc Set - ON/OFF/ TRIP lamps with control RCBOs Set - Mannual Operation Selector switch Potential Free Contacts for Remote Monitoring. Potential Bus/Busbar 1 set - 315 A TPN +E 91E Aluminium busbar Insulated with heat shrinkable sleeves, FEEDER OUTGOING - All feeder of 36KA, 1 NOs. 100A, 1 NO. 63 A Contactor ,with thyrister/thermister controls. with ON/OFF lamp & Start/Stop Push Button 1NOs. 50 KVAR, 2 NOs. 25 KVAR Capacitor panel to be provided With 7% detuned capaciters APP/MPP CAPACITOR heavy duty,with thyrister/thermister controls. [All the outgoing feeders shall have 'ON' /'OFF'/'TRIP' ,indication/Lamps. I/C's shall be mechanically & Electrically interlocked All the Lamps shall be of LED Type Only . As directed by Engineer in charge. |
| 296 | Supply,installation, testing & commissioning etc. of LT PLUMBING PANEL Construction- Floor mounted cubicle type panel, Fabricated from 14/16G CRCA ,IP52 sheet steel totally compartmentalized, treted for rust proofing. with separate busbarcamber & cable chambers Front/ back access for switchgears, connectors etc. Suitable for 430 V, 3 phase / 4 Wire System , 50 Hz supply, \\"Automatic Fire suppression gas flooding system complete with Perfluoro Ketone (FK-5-1-12)/ HFC 227ea, DLP Assembly with automatic valve, push in connector for tube, Perfluoro Ketone (FK-5-1-12)/ HFC 227ea, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.Perfluoro Ketone (FK-5-1-12)/ HFC 227ea gas of suitable capacity , Heat detection tube as required and A/V alarm with all necessary installation to complete the system as per specifications. Or as directed etc.\\" Control Unit/ Incomer- 1 No. - 125A MCCB,16kA, TPN /MP with O/C,S/C,E/F,U/V, E/L and Shunt coils etc. LED Based Phase indicating lamps, control MCBs , CTs, etc Set - ON/OFF/ TRIP lamps with control MCBs Set - ON/OFF/ TRIP lamps with control MCBs, Potential Bus/Busbar 1 set - 500A TPN+E Tinned Aluminium busbar,Insulated with heat shrinkable sleeves Feeder section/Outgoing : DOMESTIC PUMP CONTROL PANEL-1-1 No. -- 63A TPN MCB 10kA, FLUSHING PUMP CONTROL PANEL-1-1 No. -- 125A TPN MCB 10kA, GROUND FLOOR PDB-1-1 No. -- 400A TPN MCB 10kA, RWH-1-1 No. -- 16A TPN MCB 40kA, SUMP PUMP IN PUMP ROOM-1-1 No. -- 25A TPN MCB 10kA, 4 No. -- 63A TPN MCB 10kA, SPARE As directed by Engineer in charge, |
| 297 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no (4 WAY TPN DB) Make - SCHNEIDER / LEGRAND/ SIEMENS / L&T / HAVELLS |
| 298 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. (8 WAY TPN DB) |
| 299 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. (12 WAY TPN DB) |
| 300 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thicknesssuitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erectedon angle iron/GI frame. |
| 301 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. (8 WAY SPN DB) |
| 302 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. |
| 303 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. |
| 304 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no |
| 305 | Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no As directed by Engineer in charge. |
| 306 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. |
| 307 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. |
| 308 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 309 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 310 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. CB-LT/AL |
| 311 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 312 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 313 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 314 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 315 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 316 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 317 | Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling complete as per specification No:WG-PW/CW |
| 318 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit |
| 319 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 320 | Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 321 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 322 | Supplying and erecting modular type switch one way 16 / 20 A, duly erected on provided plate and box with wiring connections complete with neon indicator. |
| 323 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 324 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 325 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete |
| 326 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 327 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 328 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 329 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 330 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.As directed by Engineer in charge. |
| 331 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 332 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.As directed by Engineer in charge. |
| 333 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMSPVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modulartype switch, earthing and required accessories as per specification No: WGPW/CW |
| 334 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMSPVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modulartype switch, earthing and required accessories as per specification No: WGPW/CW |
| 335 | Point wiring for independent plug, concealed type in min 20 mm FRLSgrade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copperwires, modular type switch, earthing and required accessories as perspecification No WG-PW/SW |
| 336 | Wiring for plug on board with Switch socket surface/concealed type, copperwiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 337 | Supplying and erecting anodized aluminium mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 338 | Supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, T8 LED tube light and Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire. |
| 339 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 340 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 341 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W,CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, includingdriver complete with 3 Years warranty as per specification No FG-ODF/FLS2 |
| 342 | Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 343 | Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB |
| 344 | Supplying & erecting integral post top lantern fixtures (mushroom type)suitable for LED lamp upto 12 W consisting of clear acrylic top cover, castaluminium pole cap complete with accessories on provided pole /bracket as perspecification no. FG-ODF/PTL |
| 345 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200mm complete erected in position as per specification no. FG-FN/CF |
| 346 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 347 | Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC |
| 348 | Supplying, erecting, testing and commissioning rust free microphone table stand of chrome plating/powder coating or S.S. material, up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete. |
| 349 | Supplying and erecting midget type 3.0 litres instant type water heater ofrustproof & shockproof ABS plastic body, high grade SS inner tank & 3kWheating element with corrosion & hard water protection, with minimum 3safety protections (i.e. thermostat & thermal cut-out, function valve)complete with 6.5 bar pressure withstanding capacity 230/250V, 50Hz, A.C.supply with inlet and outlet, with 3 core PVC flexible copper wire leads dulytested and marking sr. no. and date of erection complete. |
| 350 | Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories.As directed by Engineer in charge. |
| 351 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100mm height comprising all required standard accessories |
| 352 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100mm height comprising all required standard accessories. |
| 353 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100mm height comprising all required standard accessories. |
| 354 | Providing & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 400 mmwidth & 20 mm height complete with necessary hardware. |
| 355 | Providing & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mmwidth & 20 mm height complete with necessary hardware. |
| 356 | Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 357 | Supplying and fixing cat-6 LSZH cable suitable for LAN /WAN as per specification complete. |
| 358 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. |
| 359 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification |
| 360 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 361 | Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 362 | Supplying, installing, testing & commissioning IP telephone instrument as per specification complete. |
| 363 | Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6x 16 extension complete.. |
| 364 | Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. |
| 365 | Supplying, installing, testing & commissioning IP EPABX for 10 extensions complete. |
| 366 | Supplying & installing expansion cabinet for extension of digital hybrid EPABX to expand system by 32 ports with programming and configuration of extensions and direct lines with required accessories complete. |
| 367 | Supplying, erecting & commissioning 50 pairs FR junction box with moulded plastic enclosure as per specification no. MAKE :- |
| 368 | Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. |
| 369 | Supplying and fixing cat-6 LSZH cable suitable for LAN /WAN as per specification complete. |
| 370 | Supplying and installing cat-6 cable suitable for networking as per specification no. |
| 371 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP |
| 372 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall ainted with bituminous paint with joints required. As per specification no EA-EP. |
| 373 | Supplying, installing, testing & commissioning of 64/80 Ch Network Video Recorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 Megapixel Resolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided, Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920 × 1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, support multi brand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specificationss no. CCTV-NVR |
| 374 | Supply and installation of 8TB surveillance storage Hard Disk Drive-24r/ Surveillance HDO capacity -8 TB interface- SATA lll 6 Gb/s Max sustained Transfer Rate OD- 210 MB/s cache-256 MB Tamish Resistant load /unloadcycles- 300 000 power on Hours/ year 8760 mean Tim Between failures (MTBF) - 1 million hours operatingTemperature- Ambient: 4'l F/5 C(min) Drive case : '158 F/70C (max) Non operating Temperature Ambient : 40 F/{0C (min). Make - Seagate - require 170 TB capacity for 90 days as per DIT norms |
| 375 | Supply, Installing, Testing & Commissioning of professional Monitor LED TV of 43 inches or higher size having following minimum specifications Display Size 108 cm (43 inch) Screen Type LED HD Technology & Resolution: Ultra HD (4K), 3840 x 2160 HDMI#3 nos , USB#2nos, Built In Wi-Fi Video Features: Brightness:280 nits Contrast Ratio: 5000:1 (Static),Picture in Picture (PIP) View Angle#178 Degree Aspect Ratio#16:09 Refresh Rate#60 Hz Audio Features: Number of Speakers#2nos, Output RMS#30 W Smart Tv Features Ram 2 GB, Storage Memory:8 GB Supported App - Netflix,Youtube, Disney+Hotstar,Prime Video Operating System: Android Bluetooth, Built In Wi-Fi smart wireless remote with 2nos AAA batteries operating Voltage range 110v to 220V AC 50Hz supply Power Consumption: 75 W, 0.5 W (Standby) Warranty Summary : 1 Year Warranty, 2 Years for Panel |
| 376 | Supplying & erecting of High definition 2 Megapixel IP IR Bullet Camera with following features :Image Sensor : minimum 1/2.8\\" Progressive Scan CMOS, Video Resolution : minimum 1920 x 1080Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 30m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 30m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security- User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no.CCTV-CCTV. |
| 377 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 378 | Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 379 | Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC |
| 380 | Supplying, installing and testing UTP connector (RJ-45) as per specification No.WG-NAS/UTPC. |
| 381 | Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. |
| 382 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 383 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 384 | Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK |
| 385 | Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of Min 0.5 hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification |
| 386 | Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete |
| 387 | Supplying, erecting, testing and commissioning self contained water cooler230/250V 50Hz nominal cooling capacity of 150 litres per hour and storagecapacity 150 litres with partially stainless steel body as per specification no. APWCR/WC |
| 388 | Supplying and erecting ultra violet storage type water purifier (RO+UV+UF)with softener for safe drinking water consisting of UV germicidal tube of 8Wcapacity choke made of copper wire and two indicator lamps with output ofpurified water minimum 0.33 litre/min with activated carbon filter and softeneroperating on 230V, single phase A.C. supply with UV fail & filter changeindication system .(for TDS more than 200) |
| 389 | Lightning Conductor and Accessories\\"Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standardlength with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.\\" |
| 390 | Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 391 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP |
| 392 | Making M- 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole). |
| 393 | Supplying & erecting Dewatering Monoblock pump set 415V, 3 phase,50C/s, A.C. supply of 3.73KW/ 5 H.P of 9 to 18 m head with 1125 to 500LPM discharge, 15.5mm Solid Handling Capacity, non-clogging minimised abrasive wear, large impeller clearance & maintenance free pump set with waterproof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation, specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP |
| 394 | Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 290 LPM discharge at 112 to 12 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP |
| 395 | Supplying & erecting three phase, 415V, street light control panel up to themax load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, controlwiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. ( Landscape, Facade & street lighting) |
| 396 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 397 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 11.3 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 150 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG |
| 398 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 62.5 kVA up to 82.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 399 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (2Run) |
| 400 | Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG). Standard DG size is (L6000mm x W2000mm x H2250mm), so considered foundation require as 400 mm extra from all side which comes L - 6.400 mtr, W - 2.4 mtr and depth - 1 mtr.=(7.4 + 7.4) x (3.4 + 3.4) x 1 mtr = 100.64cumtr. |
| 401 | Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete = 5.6*2.6*0.33 |
| 402 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 403 | Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete. |
| 404 | Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi and Hindi erected at position for HV/EHV installation. |
| 405 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
| 406 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all mate |
| 407 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. Cu |
| 408 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS :15683-2006 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete. |
| 409 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.As directed by Engineer in charge |
| 410 | Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) (All above contents shall be of standard makes) As directed by Engineer in charge |
| 411 | Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.. As directed by Engineer in charge |
| 412 | Supplying, installing, testing and commissioning of 10 kWp ON-GRID Solar PVSystem / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 30Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) withinterconnecting wires / cables up to solar ON GRID inverter, proper base plate,canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, signboard, two distinct earthing, lightning arrester, liaisoning charges, remotemonitoring system with maintaining card/chip for 5 years including net chargesfor RMS System, complete up to net meter installation and export to the grid with5 year ON-SITE warranty and fully comprehensive maintenance contract asper Specification no. ESD-RT-ONG |
| 413 | Supply & installation of suitable Multi stage Submersible Water Pump of approved make having proporationate discharge of borewell yield. |
| 414 | Supply & installation of wall type weather proof make autocontrol panel comprising of Voltmeter, Ammeter, SPP, powder coated 16 guage suitable rating DOL Starter, complete. |
| 415 | Supply & installation of 12 mm dia, 3 mtr. long G.I. connectingrods with threated coupling at one end & check nut at other end |
| 416 | Supply & fixing 32 mm dia.'C' class ISI mark G.I. pipe as delivery pipe for submersible pump set along with necessary fittings & other allied materials Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender