Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #58348578

Tender For Special Repair To Building No Et 23 At Hattigor Under Ge Rangia

Issued by Statutory Bodies & Commissions/Committees · Baksa, Assam
Tender Value
38.84 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
5 days left
EMD
77700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baksa → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Building No Et 23 At Hattigor Under Ge Rangia

BOQ

Name of Work:- SPECIAL REPAIR TO BUILDING NO ET 23 AT HATTIGOR UNDER GE RANGIA
Sl. No. Item Description
1Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings incl ridge, etc., complete all as specified and directed.
2Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed.
3Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
4Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., complete all as specified and as directed.
5Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified and as directed.
6Dismantling unframed timber scantlings 40 Sq cm and over in section and in any position complete all as specified and as directed.
7Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sq. Cm in section complete all as specified and as directed.
8Taking down chowkat or frame with shutter exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutter from the frame), complete all as specified and as directed.
9Taking down chowkat or frame with shutter not exceeding 1.5 Sqm (without taking off shutter from the frame), complete all as specified and as directed.
10Dismantling wrought iron steel work or any other description not otherwise provided for, complete all as specified and as directed.
11Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and as directed.
12Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed.
13M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
14M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
15M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
16M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation complete all as per specified and as directed by Engineer-in-charge.
17M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as per specified and as directed.
18M&L 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring, complete all as specified and as directed.
19M&L PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 40mm thick as in floor finished fair and even for laying of leveled bed complete all as specified and as directed.
20M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
21M & L for Double Charged Vitrified Ceramic polished tiles of dark shade 600x600 mm in size, 8-10 mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6. completed all as specified and as directed.
22M & L for Double Charged Vitrified Ceramic polished tiles of dark shade 600x600 mm in size, 8-10 mm thick, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick screed bed or bedding layers in CM 1:4. completed all as specified and as directed.
23Supply and fixing of Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat of size 125 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A-category with property of being termite/borer proof, water/moisture proof and fire retardant. Note: For WPC solid door frames, minus 5mm tolerance in Dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
24Supply & Fixing Factory made single extruded WPC (Wood Polymer Composite) Solid Plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (suspension grade), Calcium Carbonate and natural fibers (Wood Powder / Rice husk / Wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (face) & 900 N (Edge) minimum Compressive strength of 50 N/sqmm modulus of elasticity 850N/Sqmm and resistance to spread of flame of class A category with property of being termite / borer proof, water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) Stainless Steel 150mm long Tower Bolt conforming to IS 15833-2009 with and including S&F of 02 Nos. (per Leaf) Stainless Steel 150mm long handle conforming to IS 208-2020 and 300mm Stainless Steel sliding door bolt 12mm dia with and including a minimum of 6 carriage bolts and nuts four on bolt plate and two on staple plate and fixed conforming to IS 15834-2008 including taking down of existing shutter complete all specified and directed by Engineer-in-charge.
25Supply & Fixing Factory Made 30mm thick Solid Plain WPC (Wood polymer Composite) Wiremesh Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 (Suspension grade), calcium Carbonate and natural fibers (Wood Powders/ rice husk/ wheat husk) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded (Inner) with having minimum density not less than 650 kg/cum, having good screw holding capacity (Screw Withdrawal strength of 2000 N (Face) & 1100 N (Edge), Minimum Compressive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/Borer Free. Water/Moisture Proof and Fire Retardant. For fixing Mosquito mesh and XTN aluminium mesh together on panel area of door except stiles and rails to be paneled with and including mesh with self-tapping round headed screws at required distance, screws and edges covered with feathered edge beading all-around of mesh and fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws with and including 03 Nos Door Stainless steel butt hinges 100mm long with Stainless steel screws for each, 02 Nos stainless steel barrel tower bolts of extrude section, 150mm long (ISI marked) conforming to IS 15833-2009, 2 Nos stainless steel handles, 125 mm long, (ISI marked) conforming to IS 208-2020, 01 No. of helical door spring of 300 mm length including taking down of existing shutter complete all as specified and as directed by Engineer-in-charge. Note: 1. Material test certificate of all the items and authentication should be compulsory provided by the manufacturing company. 2. The rate of 03 Nos door Stainless steel butt hinges of 100mm long with Stainless steel screws for each, 02 Nos stainless steel barrel tower bolts of extrude section, 150mm long (ISI marked), 2 Nos stainless steel handles, 125 mm long, (ISI marked), 01 no. of helical door spring of 300 mm length is inclusive in this item and nothing shall be paid extra on this item. 3. The rate of taking down of existing shutter complete all specified and directed by Engineer-in-charge is included in this item and nothing shall be paid extra on this account. 4. The rate of Mosquito mesh and XTN aluminium mesh is included in this item and nothing shall be paid extra on this account.
26S&F aluminium colour powder coated (shade or tint as directed by GE) window frame of three track using Jindal or equivalent section No 20832 fixed with thrust bolt in walls by drilling and sliding shutter of section No 20844 (40x18x1.29mm) or equivalent section for glass including 3-4mm thick tinted/reflective glass fixed with rubber beading and bushes complete in two track and 0.36 mm dia and 1.40mm aperture stainless steel wire mesh with screw and aluminium beading incl aluminium grill consists of 5mm thick 50mm spacing complete all as specified and as directed.
27S&F Aluminium Colour Powder coated (Shade or tint as directed by GE) ventilator frame three track using Jindal or equivalent and sliding shutter of section with thrust bolt in walls by drilling and sliding shutter of section (40x18x1.29 mm) or equivalent section for glass include 4.0 mm thick tinted/reflective glass fixed with rubber beading and bushes complete in two track and 0.36 mm dia and 1.40 mm aperture stainless steel wire mesh with screw and aluminium beading incl aluminium grill consists of 5 mm thick 50 mm spacing complete, all as specified and as directed.
28M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 including water proofing compound as specified by manufacturer (using 12.5 mm graded stone aggregate) complete all as specified and as directed.
29S&F of GI powder coated snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 22x35x0.60mm with suspended hangers of 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with and including fixing/ laying/ inserting of pre-painted gypsum boards (595x595 mm) to Aluminium frame work with screws, complete all as specified and as directed by Engineer-in-charge.
30M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) finishing the surface fair and even without using extra cement to complete all as specified and as directed.
31M&L, 10 mm thick rendering in CM 1:6 on other than fair faces of brick work or concrete block surfaces finished fair and even without using extra cement complete all as specified and as directed.
32M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat alkali resistant priming paint applied over 1.5 mm thick wall care putty finished even and smooth on wall complete all as specified and directed.
33M&L for preparing new plastered surfaces and applying two coats of cement base paint over 1.50 mm thick wall care putty over a coat of chalk whiting on surfaces of walls complete all as specified and as directed.
34M&L for Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of black japan paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
35S&F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge.
36S&F Mild steel work in hand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work conforming to Fe 410 - O or Fe 310 - O complete all as specified and as directed.
37S & F Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and as directed.
38S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
39S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
40M&L for Reinforced Cement Concrete (Nominal Mix) 1:2:4, type B-1 (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
41M&L for Reinforced Cement Concrete (Nominal Mix) 1:2:4, type B-1 (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
42M&L for Reinforced Cement Concrete (Nominal Mix) 1:2:4, type B-1 (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
43M&L for Reinforced Cement Concrete (Nominal Mix) 1:2:4, type B-1 (20mm graded stone aggregate) in Chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
44M&L for Reinforced Cement Concrete (Nominal Mix) 1:2:4, (20mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
45Use and waste formwork to sides and soffits of concrete foundations, plinth beams and similar work for finished flat surfaces complete all as specified and as directed.
46Use and waste of form work to sides of pillars, posts, struts, piers, and stanchions for rough finished surfaces of concrete complete all as specified and directed.
47Use and waste of form work to sides and soffits of roof beams, lintels etc rough finished surfaces complete all as specified and directed.
48Use and waste formwork to chajjas and similar items including edges as in fair finished flat surfaces of concrete complete all as specified and as directed.
49Use and waste of formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
50M&L mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
51M&L mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified and as directed.
52Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/loose soil complete all as specified and as directed.
53M&L for Removing excavated material not exc. 250 m but n exc 500m depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
54Taking down carefully aluminium/copper point (light fan socket or power call bell point) complete including fittings and fixtures such as switches, Sockets, light fittings, ceiling rose, pendant, lamp holders, shades etc. Regulator and separating serviceable fittings for reuse in the same work site and making good disturbed surfaces of walls, floors, ceiling etc complete all as specified and as directed by Engineer-in-Charge.
55Taking down carefully unserviceable main switches and DBs including wooden boards and removing from site including making good disturbed surfaces of walls all complete all as specified and as directed.
56Taking down and refixing old ceiling fans and to be kept safely in store and refixing the same after complete cleaning to the existing location along with suitable fan hook/ring rod and testing complete all as specified and as directed.
57M&L for point wiring with 1.5 sq mm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and including PVC concealed (wall only) conduit and conduit accessories like bends, elbow, crosses, etc. with PVC round box and PVC terminal boxes with 300mm chain laminated cover for mounting like: switches, sockets, fan regulator, etc. incl. 1.5 sq mm size PVC insulated multistranded FRLSH copper conductor cables as earth continuity conductor and connected to earth dolly for one light/fan/switch/ fan point controlled by one 1-way switch bell push, complete all as per specified and as directed.
58All as per Item No. 57 herein-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed.
59All as per Item No. 57 herein-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed.
60All as per Item No. 57 herein-above, but for One 3/5 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed.
61S&F of Switch piano, flush type single pole. One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed.
62S&F of Socket outlet 3/5 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed.
63S&F of Switch socket combination 2 in 1, 3/5 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed.
64S&F of Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed.
65S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd., 220-240V AC, complete all as specified and as directed.
66S&F of ceiling rose surface backelite type ceiling terminal, PVC insulated body with connector box complete all as specified and as directed.
67S&F lamp holder modular, PVC/Polycarbonate type complete all as specified and as directed.
68S&F of surface and wall mounted LED tube light fitting 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed.
69S&F in-repair of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 33/34 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
70S&F 10 watt capacity, B-22 base LED bulb/lamp, complete all as specified and as directed by Engineer-in-Charge.
71S&F of Sheet Metal Enclosure MCB DB SPN, 12 way 415 volt, with 200 amps rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
72S&F of Sheet Metal Enclosure MCB DB SPN, 8 way 415 volt, with 200 amps rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
73S&Fof MCB Single Pole & Neutral (SPN), 'C' Curve, 32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
74S&F of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
75S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building street light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements, including taking down old unserviceable light fitting, complete all as specified and as directed by Engineer-in-charge.
76S&F of exhaust fan, metal body, heavy duty, AC single Phase, 230V, 50 Hz, RPM 900, Copper winding of size 300mm sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
77M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLSH cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non- metallic conduit with complete all as specified and as directed.
78Remaining excavated materials (Soils) not exc. 50.00 M and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete.
79M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation or Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
80Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
81Supply & laying in-replacement of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 16 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
82S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
83M&L for earth complete with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of nuts & washers of galvanized iron or steel; proceeded by GI pipe 15 mm bore (light grade) and watering chamber and coping shall be in PCC 1:3:6 type C-1 using 20 mm graded stone gags, 50 mm thick cover or RCC 1:2:4 type B1 using 20 mm graded stone gag, reinforced with 8 mm dia MS bar @ 200 mm c/c both way and concrete work and surplus soil complete all as shown in electrical plate no 3 of SSR Part 1, 1991 with earth lead connected to earthing test point (up to main switches, DBs) including taking down old unused cable, complete all as specified and as directed. NOTE: (i) item includes the cost of 7.5 mtr GI earth wire for protection for GI earth wire. (ii) Item rates includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58348578
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38.84 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Building No Et 23 At Hattigor Under Ge Rangia
Basic Detail
Tender No 8094/RNG/E8
Bidding Type Tender
Location
City Baksa
State Assam
Key Dates
Publish Date 03 Nov 2026
Submission Date 24 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 38.84 Lakhs
Tender Fee 500
EMD 77700
Exemption Available
Document List
8094TENDERDOCUMENT.pdf
BOQ_894022.xls
e7e09fcf-05be-4c7e-b312-16ca5a2761ee.html
Schedule_of_Credit-94.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
pdf

8094TENDERDOCUMENT.pdf

xls

BOQ_894022.xls

html

e7e09fcf-05be-4c7e-b312-16ca5a2761ee.html

pdf

Schedule_of_Credit-94.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender