Tender For Maintenance Of Street Lighting On Various Roads In Various Sectors At U.T Chandigarh (Replacement Of Existing Cable Damaged By Road Department And Other Allied Accessories On Nadda Road At U.T Chandigarh).
Tender Value
5.20 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
2 days left
EMD
10500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance Of Street Lighting On Various Roads In Various Sectors At U.T Chandigarh (Replacement Of Existing Cable Damaged By Road Department And Other Allied Accessories On Nadda Road At U.T Chandigarh).
BOQ
| Sl. No. | Item Description |
| 1 | 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 4 | Group C |
| 5 | 1.55 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 6 | Group C |
| 7 | DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | 3 x 1.5 sq. mm |
| 9 | 3 x 2.5 sq. mm |
| 10 | 3 x 4 sq. mm |
| 11 | 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | 25 mm |
| 13 | DSR 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 14 | 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 15 | 5/6 A switch |
| 16 | 3 pin 5/6 A socket outlet |
| 17 | 15/16 A switch |
| 18 | 6 pin 15/16 A socket outlet |
| 19 | Bell push |
| 20 | 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 21 | 3 Module (100mmX75mm) |
| 22 | 4 Module (125mmX75mm) |
| 23 | 6 Module (200mmX75mm) |
| 24 | 8 Module (125mmX125mm) |
| 25 | 12 Module (200mmX150mm) |
| 26 | DSR No. 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 27 | DSR No. 1.38Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 28 | 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 29 | 125 A, 16 KA,TPMCCB |
| 30 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 31 | Single pole |
| 32 | DSR Item No. 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 33 | DSR 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 34 | DSR 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 35 | DSR item No. 2.14: Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 36 | 40 Amp. |
| 37 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. |
| 38 | Size 12 inches (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make ( EXHD300-6-1)/ Bajaj make (Supreme Plus)/ Orient make (Industrial Heavy Duty)/ Usha Make (Turbo HDEF) make only. |
| 39 | Size 15 inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make ( EXHD380-6-1)/ Bajaj make (Supreme Plus)/ Orient make (Industrial Heavy Duty)/ Usha Make (Turbo HDEF) make only. |
| 40 | Size 18 inches (450mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make ( EXHD450-6-1)/ Bajaj make (Supreme Plus)/ Orient make (Industrial Heavy Duty)/ Usha Make (Turbo HDEF) make only. |
| 41 | DSR 9.2 Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 42 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 43 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 44 | S/E of 1’x4’ LED fitting surface type with integral/ non integral driver to be installed on the existing surface. The fitting should be Philips/ Wipro/ Bajaj/ Havells/ Surya/ Jaquar/ Trilux/ LT/ Crompton/ Panasonic make only. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point. The fittings should be installed at site with suitable arrangement required to complete the job. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer-in-Charge of work. The LED fittings should be as per following design criteria AS PER COMPLETE ITEM NO.19 OF DNIT. |
| 45 | Supply & erection of Cabin Fan 16” sweep oscillating type complete with blades & regulator. The fan should have 2 Nos. of pull cord switches, one for oscillation and one for speed regulation. The fan should be of Havells/ Usha/ Orient/ Bajaj/ Crompton make only. The cost includes the connection with adjacent light points and installed on wall with suitable size rag bolts, nuts and other material required to complete the job to the entire satisfaction of Engineer-in-Charge. |
| 46 | Supply and Erection of B.L Holder (ISI marked) of make Anchor Penta/ Havells (Reo)/ Goldmedal/ Lauritz Knudsen only on the existing junction box/ wooden block including making the connection etc as required. The job includes the all labour and petty material charges required to complete the job to the entire satisfaction of E.I.C. of work. |
| 47 | Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. |
| 48 | 8.2 LED Down lighter (SMD Type) (System lumen efficacy ≥120 <135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standardand trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim. |
| 49 | 22 WATT |
| 50 | DSR 8.7 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 51 | 36 watts |
| 52 | S/E of RCCB enclosure for 240 V M.S enclosure. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. |
| 53 | Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 125 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 100/125 amps TPN MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required. Make Lauritz Knudsen/ Schinder/ ABB/ Legrand/Hagar. The MCB TPN BDB & MCCBS both should be same make |
| 54 | 8 way |
| 55 | Fabrication supply and erection of cable end box U shape of size approx 2 feet height x 1 feet deep x 1.5 feet wide made out of 16 Gauge M.S sheet duly powder coated paint after applying the coat of primer of spiral quality. The M.s box sheet should be bend 2 inch approx both side for fixing on wall with the help of fastener. The job also includes the cost of erection all labour and petty material required to complete the job to the entire satisfaction of the SDE-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender