Tender For Repair/Maint Of Electrically Operated Lift/Elevator At Northern And Southern Part Of Garrison Under Ge (Utilities) Udhampur
Tender Value
99.93 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
28 days left
EMD
1.74 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Electrically Operated Lift/Elevator At Northern And Southern Part Of Garrison Under Ge (Utilities) Udhampur
BOQ
| Sl. No. | Item Description |
| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR/MAINT OF ELECTRICALLY OPERATED LIFT/ELEVATOR AT NORTHERN AND SOUTHERN PART OF GARRISON UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)-80/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Repair / maintenance of lifts including carrying out daily checking Periodical servicing by rep of OEM or Equivalent of the lift at Naubat Ram Vihar (0 8 Passenger & 13 Passenger- 38 Nos, G+6) to maintain in are liable, safe and efficient manner using latest techniques & experts by carrying out planned maintenance in a systematic and controlled manner by regularly examining, testing, lubricating and adjusting of all the items of lifts inculding repair/replacement of all defective parts i.e all type of mechanical and electrical items ,check that lift stop in downward direction properly with 25% overload with operation of the \\"emergency stop\\" when lift is moving at full speed, check and lubricate by grease cup or top up oil on sleeve type bearing on: Motorshaft,deflector sheave shaft,governor pulley. Check and lubricate sleeve of governor tensioning pull at the pit.Controller:- Clean contacts and shields with carbon tetra-cholride. Move relay armature by hand for free movement and see that contacts are aligned. Replace carbon contacts if wornout, Check fuses of controller and mains, Brake oil in dashpots. Check flexible leads to relay. Check and adjust carbon brushes spring pressure commutator reseat brushed. Greasing the bearing AC motors:- Lubricate bearing. Clean ventilation passenger car. Inspect for tray noises. Lubricate bearing and top up oil in gear box. |
| 3 | Repair / maintenance of lifts including carrying out daily checking Periodical servicing by rep of OEM or Equivalent of the lift at Albert Ekka Enclave (08 Passenger & 13 Passenger- 36 Nos, G+6) to maintain in are liable, safe and efficient manner using latest techniques & experts by carrying out planned maintenance in a systematic and controlled manner by regularly examining, testing, lubricating and adjusting of all the items of lifts inculding repair/replacement of all defective parts i.e all type of mechanical and electrical items ,check that lift stop in downward direction properly with 25% overload with operation of the \\"emergency stop\\" when lift is moving at full speed, check and lubricate by grease cup or top up oil on sleeve type bearing on: Motorshaft,deflector sheave shaft,governor pulley. Check and lubricate sleeve of governor tensioning pull at the pit.Controller:- Clean contacts and shields with carbon tetra-cholride. Move relay armature by hand for free movement and see that contacts are aligned. Replace carbon contacts if wornout, Check fuses of controller and mains, Brake oil in dashpots. Check flexible leads to relay. Check and adjust carbon brushes spring pressure commutator reseat brushed. Greasing the bearing AC motors:- Lubricate bearing. Clean ventilation passenger car. Inspect for tray noises. Lubricate bearing and top up oil in gear box. |
| 4 | Repair / maintenance of lifts including carrying out daily checking Periodical servicing by rep of OEM or Equivalent of the lift at Sansar Chand Vihar (08 Passenger & 13 Passenger- 20 Nos, G+6) to maintain in are liable, safe and efficient manner using latest techniques & experts by carrying out planned maintenance in a systematic and controlled manner by regularly examining, testing, lubricating and adjusting of all the items of lifts inculding repair/replacement of all defective parts i.e all type of mechanical and electrical items ,check that lift stop in downward direction properly with 25% overload with operation of the \\"emergency stop\\" when lift is moving at full speed, check and lubricate by grease cup or top up oil on sleeve type bearing on: Motorshaft,deflector sheave shaft,governor pulley. Check and lubricate sleeve of governor tensioning pull at the pit.Controller:- Clean contacts and shields with carbon tetra-cholride. Move relay armature by hand for free movement and see that contacts are aligned. Replace carbon contacts if wornout, Check fuses of controller and mains, Brake oil in dashpots. Check flexible leads to relay. Check and adjust carbon brushes spring pressure commutator reseat brushed. Greasing the bearing AC motors:- Lubricate bearing. Clean ventilation passenger car. Inspect for tray noises. Lubricate bearing and top up oil in gear box. |
| 5 | Repair / maintenance of lifts including carrying out daily checking Periodical servicing by rep of OEM or Equivalent of the lift at Anant Ram Vihar (08 Passenger & 13 Passenger- 14 Nos, G+6) to maintain in are liable, safe and efficient manner using latest techniques & experts by carrying out planned maintenance in a systematic and controlled manner by regularly examining, testing, lubricating and adjusting of all the items of lifts inculding repair/replacement of all defective parts i.e all type of mechanical and electrical items ,check that lift stop in downward direction properly with 25% overload with operation of the \\"emergency stop\\" when lift is moving at full speed, check and lubricate by grease cup or top up oil on sleeve type bearing on: Motorshaft,deflector sheave shaft,governor pulley. Check and lubricate sleeve of governor tensioning pull at the pit.Controller:- Clean contacts and shields with carbon tetra-cholride. Move relay armature by hand for free movement and see that contacts are aligned. Replace carbon contacts if wornout, Check fuses of controller and mains, Brake oil in dashpots. Check flexible leads to relay. Check and adjust carbon brushes spring pressure commutator reseat brushed. Greasing the bearing AC motors:- Lubricate bearing. Clean ventilation passenger car. Inspect for tray noises. Lubricate bearing and top up oil in gear box. |
| 6 | Repair / maintenance of lifts including carrying out daily checking Periodical servicing by rep of OEM or Equivalent of the lift at Tushar Vihar & Old Medical Complex (08 Passenger & 13 Passenger-04 Nos, G+6) to maintain in are liable, safe and efficient manner using latest techniques & experts by carrying out planned maintenance in a systematic and controlled manner by regularly examining, testing, lubricating and adjusting of all the items of lifts inculding repair/replacement of all defective parts i.e all type of mechanical and electrical items ,check that lift stop in downward direction properly with 25% overload with operation of the \\"emergency stop\\" when lift is moving at full speed, check and lubricate by grease cup or top up oil on sleeve type bearing on: Motorshaft,deflector sheave shaft,governor pulley. Check and lubricate sleeve of governor tensioning pull at the pit.Controller:- Clean contacts and shields with carbon tetra-cholride. Move relay armature by hand for free movement and see that contacts are aligned. Replace carbon contacts if wornout, Check fuses of controller and mains, Brake oil in dashpots. Check flexible leads to relay. Check and adjust carbon brushes spring pressure commutator reseat brushed. Greasing the bearing AC motors:- Lubricate bearing. Clean ventilation passenger car. Inspect for tray noises. Lubricate bearing and top up oil in gear box. |
| 7 | Repair / maintenance of lifts including carrying out daily checking Periodical servicing by rep of OEM or Equivalent of the lift at Ashok Vihar(13 Passenger- 01 Nos, G+6) to maintain in are liable, safe and efficient manner using latest techniques & experts by carrying out planned maintenance in a systematic and controlled manner by regularly examining, testing, lubricating and adjusting of all the items of lifts inculding repair/replacement of all defective parts i.e all type of mechanical and electrical items ,check that lift stop in downward direction properly with 25% overload with operation of the \\"emergency stop\\" when lift is moving at full speed, check and lubricate by grease cup or top up oil on sleeve type bearing on: Motorshaft,deflector sheave shaft,governor pulley. Check and lubricate sleeve of governor tensioning pull at the pit.Controller:- Clean contacts and shields with carbon tetra-cholride. Move relay armature by hand for free movement and see that contacts are aligned. Replace carbon contacts if wornout, Check fuses of controller and mains, Brake oil in dashpots. Check flexible leads to relay. Check and adjust carbon brushes spring pressure commutator reseat brushed. Greasing the bearing AC motors:- Lubricate bearing. Clean ventilation passenger car. Inspect for tray noises. Lubricate bearing and top up oil in gear box. |
| 8 | Repair / maintenance of lifts including carrying out daily check and Periodical servicing by rep of OEM or Equivalent of the lift (G+1) at NewCommand Hospital Northern Command (08 Passenger- 01Nos) to maintain in a reliable, safe and efficient manner usinglatest techniques & experts by carrying out plannedmaintenance in a systematic and controlled manner byregularly examing, testing, lubricating and adjusting of all theitems of lifts with inculding repair/ replacement of all defectiveparts i.e all type of mechanical and electrical items ,check thatlift stop in downward direction properly with 25% overload withoperation of the \\"emergency \\" stop when lift is moving at fullspeed, check and lubricate by grease cup or top up oil onsleeve type bearing on: Motor shaft,deflector sheaveshaft,governor pulley. Check and lubricate sleeve of governortensioning pull at the pit. Controller:- Clean contacts andshields with carbon tears cholride. Move relay armature byhand for free movement and see that contacts are aligned.Replace carbon contacts if worn out, Check fuses of controllerand mains, Brake oil in dash pots. Check flexible leads to relay.Check and adjust carbon brushes spring pressure commutatorreseat brushed. Greasing bearing. AC motors:- Lubricatebearing. Clean ventilation passenger. Inspect for tray noises.Lubricate bearing and top up oil in gear box. |
| 9 | Description all as per Srl item No 7 here in before but for (G+5) at New Command Hospital Northern Command, 02 Nos, JCO/OR Accn 02 Nos, Single Offrs Accn (08 Passenger- 04 Nos) |
| 10 | Description all as per Srl item No 7 here in before but for (B+G+5) with machine room at New Command Hospital Northern Command, (08 Passenger- 02 Nos) |
| 11 | Description all as per Srl item No 7 here in before but for (G+4) with Machine Room at New Command Hospital Northern Command - 02 (20 Passenger- 02 Nos) |
| 12 | Description all as per Srl item No 7 here in before but for (G+2) at New Command Hospital Northern Command - 02 (26 Passenger- 02 Nos) |
| 13 | Description all as per Srl item No 7 here in before but for (G+2) with M/c Room at New Command Hospital Northern Command - 02 (26 Passenger- 01 Nos) |
| 14 | Description all as per Srl item No 7 here in before but for (B+G+5) with M/c Room at New Command Hospital Northern Command - 04 (26 Passenger- 06 Nos) |
| 15 | Note :-(i) The Contractor need to deploy lift engineers of OEM or equivalent round the clock to ensure continous operation of lifts.(ii) The MOU of all lifts from Sr No. 1 to 13 shall be submitted in all respect along with connected documents reflecting the conditions mentioned in the description within 30 days of work order issued by GE. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 28 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 30 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender