BOQ
| Sl. No. | Item Description |
| 1 | Taking out the existing CI/DI pipe line of any class, including CI fittings with spigot and socket ends and lead joints of any class/type, for the following sizes, complete as specified and directed. Notes:- (i) While taking out the existing pipe line of any type, adequate arrangements shall be made to ensure that there is no major interruption/breakdown in the water supply.(ii) Existing SCADA-operated valves shall be properly dismantled and re-fixed without any extra cost.(iii) While taking out the existing CI/DI pipe line in the Hills Area, due care shall be exercised to avoid damage to the existing pipe/valve pedestal. Any damage caused during execution shall be made good/repaired by the contractor without any extra cost. |
| 2 | 200 mm bore |
| 3 | 200 mm bore |
| 4 | Supply, laying, connecting on existing RCC/PCC plinth and testing of DI pressure pipes, ISI marked and conforming to IS 8329:2000 (Reaffirmed 2005), Class K-9, of 250 mm bore, with flanged ends on both sides suitable for “Flange Joint”, in standard working lengths, supplied with ISI-marked rubber gaskets for water service. The pipes shall be internally lined with cement mortar and externally coated with metallic zinc with a finishing layer of bituminous paint, without polyethylene sleeve, including “Flange Joint” with ISI-marked EPDM rubber gasket conforming to IS 5382:1985 (Reaffirmed 2003), having dual hardness of Type-2 (Bulb) and Type-5 (Heel), complete as specified and directed. |
| 5 | 200 mm bore |
| 6 | 250 mm bore |
| 7 | Supply, laying, connecting on existing RCC/PCC plinth and testing of DI pressure pipes, ISI marked and conforming to IS 8329:2000 (Reaffirmed 2005), Class K-9, of 250 mm bore, with flanged ends on both sides suitable for “Flange Joint”, in standard working lengths, supplied with ISI-marked rubber gaskets for water service. The pipes shall be internally lined with cement mortar and externally coated with metallic zinc with a finishing layer of bituminous paint, without polyethylene sleeve, including “Flange Joint” with ISI-marked EPDM rubber gasket conforming to IS 5382:1985 (Reaffirmed 2003), having dual hardness of Type-2 (Bulb) and Type-5 (Heel), complete as specified and directed. |
| 8 | Cutting of cast iron pipes in position for insertion of new tees , branches, etc for the following sizes complete all as specified and directed :- |
| 9 | 200 mm bore |
| 10 | 250 mm bore |
| 11 | Supplying, fixing and testing of DI pipe fittings (specials), heavy duty for any type (flanged/socketed) pipes such as bends (any type radius, and angle) tapers (any type), straight bend, increasing, decreasing or double socket etc, Tee pieces, ring branch, 'Y' junction double branch, cross (all socket or socket and spigot) collors, caps and plugs, adopters, mechanical joint, flange tee, etc of any size radius and lenght confirming to IS:9523/2000 specifications with external bitumen coating and internal |
| 12 | M&L for run lead joint for spigot and socketed end CI pipe & fittings complete all as specified incl excavation, returning & refilling and directed by Engr in charge for following :- |
| 13 | 200 mm bore |
| 14 | 250 mm bore |
| 15 | Supply, installation, connecting and testing sluice valve cast iron body class-PN 1.6 with flanged ends drilled suitable for foloowings bore of pipe , ISI marked (IS:14846:2000) having brass spindle with iron wheel at top complete with nuts bolts washers rubber gasket etc complete all as specified and directed. |
| 16 | 200 mm bore |
| 17 | 250 mm bore |
| 18 | Taking out old mechanical Joint and s& F new MJ/DI Adpter of followng size including nut bolt all connecting accessories all specified and directed. |
| 19 | 200 mm bore |
| 20 | 250 mm bore |
| 21 | Supply & Fixing Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast ron Water supply mains of size 200/250 mm dia. complete all as specified and directed. |
| 22 | Supply & Fixing Non Return valve flange end conforming to IS 4038, 200 mm dia, PN - 10 including necessary rubber sheet , nut bolt all connected accessories etc complete all specified and directed. |
| 23 | Material & Labour for construction of brick masonary Valve pit chamber of 1000mm x 1000 mm x 1000 mm size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6 rendering in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mm x 50mm x 6mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed. |
| 24 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundation etc or for manholes, laying of pipe lines,cables,pipes etc in any type of soil and getting out complete all as specified. |
| 25 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundation etc or for manholes, laying of pipe lines,cables,pipes etc in Soft/disintegrated rock and getting out complete all as specified. |
| 26 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundation etc or for manholes, laying of pipe lines,cables,pipes etc in Hard Rock and getting out complete all as specified. |
| 27 | Returning filling in, including spreading, leveling watering & well rammng in layers not exc 25 cm thick complete all as specified and directed. Note:- Returning filling at hard rock locations,Soil to be collected from the removal soil material and filling the hard/dense site locations.Transpotaion and labour expenditure to be incluisive in deemed rate. |
| 28 | Supply, fabrication and fixing MS chennal/pipe fitting/barrel piece /lateral pipe as per site requirement with MS pipe, C class, heavy duty including nut, bolt, washer, clamp, welding etc and fibre board gasket complete and making joint leak proof including dismantling old structure complete all specified and directed. |
| 29 | Material & Labour boring of holes, under road, pavement, hard standing by trencheless method /manual auguring with & including reinforced complete all specified and directed. |
| 30 | Material and labour for cutting the existing pipe line on both sides of the pedestal of size 250 mm, without damaging the pedestal, complete in all respects as specified and directed. |
| 31 | M&L for plain cement concrete (1:2:4.) type B2 for plinth blocks using 40 mm graded coarse aggregate including fair finishing the exposed surfaces even and smooth without using extra cement and necessary form work all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysDec 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender