Tender For Provn For Hard Standing For Car Parking In Front Of Single Officers Accn (Soa) And Tf-3 Alongwith Allied Work At Drdo Township, Phase-I, Cv Raman Nagar, Bangalore
Tender Value
35 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
15 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn For Hard Standing For Car Parking In Front Of Single Officers Accn (Soa) And Tf-3 Alongwith Allied Work At Drdo Township, Phase-I, Cv Raman Nagar, Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE OF WORKS |
| 2 | Demolishing of cement concrete, Nominal concrete or leaner mix (i/c equivalent design mix) manually or by mechanical means including disposal of material outside of MoD Land as per direction of Engineer - in - charge. |
| 3 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of material outside of MoD Land, for all kind of soil as directed by Engineer-in- Charge |
| 4 | Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material outside of MoD land, for which payment shall be made separately all as per direction of Engineer-in-Charge. |
| 5 | Supplying and laying for 100mm thick broken boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 6 | Providing and laying in position cement concrete 1:3:6 (1 Cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) ) excluding the cost of centering and shuttering - for all work upto plinth level. |
| 7 | Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks, 60mm thick of M-35 grade, in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand ( to be measured and paid seperately), compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, with paver blocks of approved colour, design & pattern complete all as per direction of Engineer-in-Charge. |
| 8 | M&L for Sand filling under floors or in foundations including watering and consolidation |
| 9 | M&L for precast RCC (1:2:4) type B1 using 20 mm graded stone aggregate as in manhole covers, cover slab and set in CM 1:4 including necessary form work complete (note : steel for reinforcement will be measured and paid separately) |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level, Thermo-Mechanically Treated bars of grade Fe-500D or more complete all as specified |
| 11 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete, placed in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer- in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 12 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to outside MoD land for all lifts, complete as per directions of Engineer-in-charge. |
| 13 | Providing and laying Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including floating coat finishing complete. |
| 14 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 15 | Demolishing brickwork in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material removing debris outside MD land as per direction of Engineer-in-charge. |
| 16 | Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approved manufacturer in superstructure above plinth level up to floor V level in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 17 | Providing and laying in position cement concrete 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) excluding the cost of centering and shuttering - All work up to plinth level all as specified and as directed |
| 18 | M & L for 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand) complete alll as specified and as directed. |
| 19 | Dismantling steel work manually or by mechanical means in built up sections without dismembering and stacking within 50 Metres lead as per direction of Engineer-in-charge.NOTE:- The quantity of steel retrieved from dismantling shall be deposited to the MES storeyard under AGE B/R-II complete as directed. |
| 20 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 21 | Providing and fixing G.I. chain link fabric fencing made of G.I. wire of dia. 4 mm, required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge |
| 22 | Fixing in only chain link fencing of any size including line wires, any mesh size and type to any type of standards, rails, straining bolts etc. including provision of binding wire. |
| 23 | Providing and laying Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including floating coat finishing complete. |
| 24 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50M and for all lift. |
| 25 | Removing excavated material outside MoD land all as directed |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work steel surfaces in suitable shade with ordinary paint of approved brand and manufacture |
| 27 | Supply ,fixing and erection of steel tubular swaged pole 9 metre long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified, type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm height upto 1.5 mtr above ground level all as required at site or directed by Engr-in-charge. |
| 28 | Material and Labour for PCC 1:3:6 type C1 using 20mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and as directed. |
| 29 | Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified. |
| 30 | Supply and fix of light grade Galvanised mild steel pipe 40mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction . (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ) |
| 31 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 mtr in depth for foundation in hard/dense soil and getting out for erection of street light pole all as directed. |
| 32 | Returning filling including spreading, levelling , watering and well ramming in layers n.exc 25cm in soil as directed . |
| 33 | Removing of excavated soil to a distance not exc 50 m & depositing where as directed at a level n.exc 1.5m above starting point all as specified and as directed. |
| 34 | M & L for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6 mm thick buried in ground vertically to a depth not less than 2.25 metre below normal ground level, normal with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate connected to a galvanised earth lead wire 4mm dia bymeans of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to earth test point all as specified or indicated including testing on completion with and including 15 mm bore light grade GI protection pipe 7.5 meters long for earth including PCC 1:2:4 pit with pre cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrange,ent with funnel wire, common salt and charcoal filling, necessary excavation and earth work in any type of soil complete all as specified. |
| 35 | Supply and fix LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with complete all as specified and directed |
| 36 | Supply of LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumnium conductor of size 10 Sqmm 4 core .(Cable for connection of LT panel) |
| 37 | Laying only PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade up to 35 Sqmm size direct in ground including excavation, 63 mm dia (OD-63mm & D-51mm nominal) size DWC HDPE pipe including refilling and removal of extra soil shall be inclusive of rate quoted by the contractor, all as specified and directed. |
| 38 | Supply , Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 65 fabricated by CPRI validated certified approved panel manufacturere's in and including suitable terminal TPN 10 KA SMC Connector, MCB C Type SP 6 Amps , canopy on top in a slanting manner, weather proof, hinged doors, side locking system with hinges and also panel locks on top and bottom of door in and including fixing of MS flat on rear side of the box for fixing on Steel Pole using MS clamps of suitable size not less than 25 x 5 mm nut bolts washers etc all as per site requirement including cable reconnections with new lugs and glands as required at site complete all as directed by Engineer-in-charge. |
| 39 | Material and labour for wiring from junction box to security light with 2.5 sqmm 3 core PVC insulated cable copper conductor multi standed FRLS drawn through in and including new PVC non mettallic rigid conduit of 25mm concealed /surface type including all accessories complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender