Tender For Certain Repair/Replacement Of Ht Ug Cable, God, Overhead Conductor Under Ge Gurdaspur
Tender Value
60 Lakhs
Estimated cost
Bid Submission
01 Dec 2026
26 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurdaspur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Certain Repair/Replacement Of Ht Ug Cable, God, Overhead Conductor Under Ge Gurdaspur
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 m wide and n.exc. 1.5 m in depth for poles, stay, cable, pipe etc and getting out complete all as specified and directed. |
| 2 | Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 m wide and depth exceeding 1.5 m and n. exc 3 m for poles, stay, cable, pipe etc and getting out complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil complete all as specified and directed. |
| 4 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above, the starting point complete all as specified and directed. |
| 5 | Supply and laying un-reinforced precast concrete cable cover, class HV, type I, flat, size 300 mm x 180 mm x 40 mm laid flat in trenches over the cable with the length of cable cover perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed. |
| 6 | Material and labour for Sand cushioning trenches using fine sand to underground cable, laid in two layers 8cm before laying the cable & 15cm punned down to 10 cm after laying the cable complete all as specified and directed.Note: Punned down thickness shall be considered for measurement. |
| 7 | Material and labour for in replacement of cable protection GI tubing light grade fixed along the pole/under road/along the wall of size 100mm bore with necessary clamps complete all as specified and directed. |
| 8 | Material and labour in replacement for cable protection GI tubing light grade fixed along the pole/under road/along the wall of size 80mm bore with necessary clamps complete all as specified and directed. |
| 9 | Material and labour for crossarms in replacement , bracing, supports, clamps and brick plates, fabricated from structural steel section including nut and bolts washers including welding, bending , cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of Aluminium paint over a coat of red oxide complete all as specified and directed. |
| 10 | Supply and fixing in replacement of vertical polymer type switch air break gang operated switch triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps and working voltage of 11000 volts grade consisting of 4 insulator per pole with 25 mm dia GI medium grade operating handle and locking arrangements fixed with down rod operating brackets complete all as specified and directed. |
| 11 | Supply and fixing in replacement of vertical polymer type switch air break gang operated switch triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating 400 Amps and working voltage of 11000 volts grade consisting of 4 insulator per pole with 25 mm dia GI medium grade operating handle and locking arrangements fixed with down rod operating brackets complete all as specified and directed. |
| 12 | Supply & laying in replacement of underground XLPE insulated and PVC sheathed Galvanised steel strip (E) armoured (underground) heavy duty electric cable with stranded aluminium conductor 11000 volts (E) grade of cross sectional area 300 Sqmm 3 core conforming to IS-7098 (partII) 1985 with the latest amendment laid in trenches/ducts/through pipes/in floor/road/along the pole etc complete all as specified and directed. |
| 13 | Supply & laying in replacement of underground XLPE insulated and PVC sheathed Galvanised steel strip (E) armoured (underground) heavy duty electric cable with stranded aluminium conductor 11000 volts (E) grade of cross sectional area 185 Sqmm 3 core conforming to IS-7098 (partII) 1985 with the latest amendment laid in trenches/ducts/through pipes/in floor/road/along the pole etc complete all as specified and directed. |
| 14 | Supply & laying in replacement of underground XLPE insulated and PVC sheathed Galvanised steel strip (E) armoured (underground) heavy duty electric cable with stranded aluminium conductor 11000 volts (E) grade of cross sectional area 150 Sqmm 3 core conforming to IS-7098 (partII) 1985 with the latest amendment laid in trenches/ducts/through pipes/in floor/road/along the pole etc complete all as specified and directed. |
| 15 | Supply & laying in replacement of underground XLPE insulated and PVC sheathed Galvanised steel strip (E) armoured (underground) heavy duty electric cable with stranded aluminium conductor 11000 volts (E) grade of cross sectional area 120 Sqmm 3 core conforming to IS-7098 (partII) 1985 with the latest amendment laid in trenches/ducts/through pipes/in floor/road/along the pole etc complete all as specified and directed. |
| 16 | Supply & laying in replacement of underground XLPE insulated and PVC sheathed Galvanised steel strip (E) armoured (underground) heavy duty electric cable with stranded aluminium conductor 11000 volts (E) grade of cross sectional area 95 Sqmm 3 core conforming to IS-7098 (partII) 1985 with the latest amendment laid in trenches/ducts/through pipes/in floor/road/along the pole etc complete all as specified and directed. |
| 17 | Supply and fix in replacement Pin type, porcelain insulator including two Galvanised iron washers and one Galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed. |
| 18 | Supply and fixing in replacement of 25 mm dia GI pipe medium grade including locking arrangement for operating the GOD complete all as specified and directed. |
| 19 | Supply and Fixing in Replacement of Steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) including painting with two coats of aluminium paint over a coat of red oxide primer including 5 Nos alternate bands/ strips of 30cm wide each with two coats of radium spray/synthetic enamel paint (Red and Yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking of pole number with thick synthetic enamel paint (white) including preparation of surface complete all as specified and directed. |
| 20 | Material & labour for stay assembly complete comprising of 7/3.15 Galvanised stranded stay wire of required length, fixed to pole with and including Flat Iron (FI) clamps 50 x 6 mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long, stay bow 400 x14mm, GI steel plate 300x300x6mm, Disc type insulator, porcelain,vitreous 145mm high and 255mm dia ball and socket type, white, brown or green clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate No. 1 of SSR part - I 2009 on Page No 495 complete all as specified and directed. (Note :- Earthwork, PCC work, and Insulator measured and paid separately) |
| 21 | Material and labour for Providing PCC 1:4:8 type D:2 using 40mm graded crushed stone aggregate as in foundation for pole/stay assembly foundation coping of poles etc. complete all as specified and directed. |
| 22 | Material and labour for providing PCC 1:3:6 type C:2 using 40mm graded crushed stone aggregate as in foundation for pole/stay assembly foundation coping of poles etc complete all as specified and directed. |
| 23 | Material and labour for Providing PCC 1:2:4 type B:2 using 40mm graded crushed stone aggregate as in coping of poles incl taking down of old coping of the pole complete all as specified and directed. |
| 24 | Material and labour for preparation of old painted steel and iron surfaces and painting to steel structures installed at 66 KV Sub Station and other substation and applying two coats of aluminium paint on cross arms, bracing, clamps, channels etc complete all as specified and directed. |
| 25 | Supply and fixing in replacement of lightning arrester expulsion type for out door use complete with all fittings, station-class discharge capacity 65 KA suitable for 11000 volts including bracket, clamps, nuts, bolts washers and connection to each wire complete all as specified and directed. |
| 26 | Supply and fixing in replacement ACSR conductor including stretching on OH line including binding on insulators with aluminium binding wire including jumpers and jointing complete all as specified and directed.Note :- (i) Weight of ACSR or all aluminium conductor drawn for OH lines is to be measured by measuring tape horizontal distance between centres of two adjacent poles and computing the weight of conductor of that size and length and 3 % extra added for sag, jointing, jumpers and binding etc complete all as specified and directed.(ii) Weight of conductor shall be calculated from tables given in the relevant I.S. Please Enable Macros to View BoQ information |
| 27 | Supply and fixing in replacement ACSR conductor including stretching on OH line including binding on insulators with aluminium binding wire including jumpers and jointing complete all as specified and directed.Note :- (i) Weight of ACSR or all aluminium conductor drawn for OH lines is to be measured by measuring tape horizontal distance between centres of two adjacent poles and computing the weight of conductor of that size and length and 3 % extra added for sag, jointing, jumpers and binding etc complete all as specified and directed.(ii) Weight of conductor shall be calculated from tables given in the relevant I.S. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysDec 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender