Heavy Industries and Public Enterprises Government Departments Closing in 15 days TDR #58343769

Bids Are invited for Supply, Installation, Testing Commissioning (Sitc) Of Electrical Panel For Ev Evse Test Setup - 1000A Acb Incomer Lt Panel: Metal-Enclosed Lt Panel Comprising And Outgoing Feeders Consisting Of 4 Nos. 630A 4 Pole Mccbs 1 No. 125A

Issued by Government Departments · Gurgaon, Haryana
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Nov 2026
15 days left
EMD
48000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Supply, Installation, Testing Commissioning (Sitc) Of Electrical Panel For Ev Evse Test Setup - 1000A Acb Incomer Lt Panel: Metal-Enclosed Lt Panel Comprising And Outgoing Feeders Consisting Of 4 Nos. 630A 4 Pole Mccbs 1 No. 125A 4 Pole Mccbs, 2 Nos. 63A 4 Pole Mccbs, 2 Nos. 40A 4 Pole Mcbs, 2 Nos. 32A 4 Pole Mcbs And 2 Nos. 4 Pole Mcbs, Suitable For 415V Ac, 50Hz, 3 Phase, 4 Wire System, Complete With 1250A Electrolytic Aluminium Busbars, 1250/5A Cts, Class 0.5S Multifunction Energy Meter, Under Voltage & Over Voltage Protection Relay, Ryb Phase Indication Lamps, On/Off/Trip Indication Lamps, Control Mcbs, Panel Heater, Panel Exhaust Fan, Panel Light, Frls Control Wiring, Cable Alleys, Removable Top/Bottom Entry With Gland Plates, Earthing Terminals And Ms Panel Base Frame. The 1000A Acb Incomer Shall Be Provided With A Microprocessor-Based Electronic Lsig Trip Unit, Motorized Spring Charging Mechanism, Closing Coil, Shunt Trip Coil, Under-Voltage Release, Auxiliary Contacts, Draw-Out Cradle Assembly And Safety Shutters, Having A Minimum Short-Circuit Breaking Capacity Of 50Ka At 415V Ac, Suitable For Reliable Protection, Isolation And Switching Of Low- Voltage Power Distribution System. The Panel Shall Conform To Is/Iec 61439-1, Is/Iec 61439-2 And Is/Iec 60947-2, Complete In All Respects.[ All Mccb With Spreader Links And Rotary Handle]Lt Enclosure Panel Along With 4 Pole 1000 Ampere Acb, Dust Proof, Vermins Proof, Cubical Design Modular, Floor Mounted Indoor, Plate Provision, 3Phase 4 Wire 415V, 50 Hz. , Aluminium Armoured Cable Xlpe Type Size: 3.5 Corex300 Sqmm. , Heavy Duty Hot Dip Galvanized (Hdg) Perforated Cable Tray Of Size 300 Mm Width × 75 Mm Height With Minimum 2 Mm Thickness, Complete With Matching Gi Cover, Couplers/Jointers, Angle Mounting Supports,Fasteners, And Threaded Gi Stud Rods,As Per Is Standard. , Double Compression Gland Suitable For 3.5Cx300 Sqmm Aluminium Armoured Cable Xlpe Type , Aluminium Lugs Size: 300 Sqmm , Aluminium Lugs Size: 185 Sqmm , Maintenance-Free Gi Chemical Plate Earthing Comprising 600 Mm × 600 Mm × 6 Mm Hot Dip Galvanized Gi Plate Electrode With Approved Conductive Chemical Backfill Compound, Complete With 25 Mm × 6 Mm Hdg Gi Earth Strip, Gi Watering Pipe With Funnel (Where Required), Test Link, Brick Masonry Earth Chamber With Heavy-Duty Ci/Rcc Cover, Excavation, Backfilling, All Accessories And Interconnections, Complete To Achieve Earth Resistance As Per Is 3043:2018 , Gi Earthing Strips Size:25 Mm × 6 Mm Hot Dip Galvanized (Hdg) Gi Earthing Strip Conforming To Is 2062 And Hot-Dip Galvanized As Per Is 4759 , Cable Tie 300 Mm , Pvc Tape Colour( R,Y,B,N & Green) , Supply, Installation, Testing And Commissioning Of 1000A, 4-Pole, Draw-Out Type Acb, 415V Ac, 50Hz, Minimum 50Ka Icu At 415V, With Electronic Lsig Trip Unit, Motorized Spring Charging, Closing Coil, Shunt Trip, Under-Voltage Release, Auxiliary Contacts, Draw-Out Cradle And Safety Shutters, Complete With All Accessories As Per Is/Iec 60947-2.The Scope Shall Include Modification Of Existing Lt Panel, Acb Mounting Arrangement, Busbar Modification/Extension With Suitable Rated Links And Supports, Insulation Barriers, Cts, Multifunction Energy Meter, Indication Lamps, Control Mcbs, Frls Control Wiring, Terminal Blocks, Earthing, Gland Plates, Labels And All Necessary Hardware/Consumables.Complete Work Shall Include Testing And Commissioning, Including Insulation Resistance, Contact Resistance, Primary/Secondary Injection And Functional Testing Of Acb Protection And Accessories. The Modified Lt Panel Assembly Shall Comply With Is/Iec 61439-1 And Is/Iec 61439-2, Complete In All Respects. , Sitc Of 1250A Electrolytic Aluminium Input And Output Busbars For Connection Of The 1000A Acb With The Existing Lt Panel, Complete With Suitable High-Strength Busbar Supports/Insulators, Jointing Hardware, Flexible/Rigid Links, Insulation Sleeves/Barriers And All Necessary Accessories, Including Fabrication, Cutting, Drilling, Bending, Installation, Jointing, Testing And Commissioning, Suitable For The Required Short-Circuit Withstand And Complying With Is/Iec 61439-1 & Is/Iec 61439-2, Complete In All Respects. , Supply, Fabrication, Installation, Testing And Commissioning Of Crca Sheet Steel Enclosure For Extension Of Existing Lt Panel, Cubicle Type, Size 2200(H) × 1100(W) × 1400(D) Mm, Complete With Suitable Ms Angle Base Frame/Stand, Hinged And Lockable Doors, Removable Gland Plates, Cable Alley, Ventilation Provisions, Panel Exhaust Fan With Thermostat And Panel Heater With Thermostat, Earthing Terminals, Internal Supports And Hardware, Suitable For Accommodating 1000A, 4-Pole Acb Incomer. The Scope Shall Also Include Sitc Of 1250A Electrolytic Aluminium Input And Output Busbars, Complete With Suitable Busbar Supports, Insulators, Links, Jointing Hardware, Sleeves/Insulation Barriers And Connections To The Existing Lt Panel Busbars. The Enclosure And Modified Panel Assembly Shall Comply With Is/Iec 61439-1 & Is/Iec 61439-2, And The Acb Shall Comply With Is/Iec 60947-2, Complete In All Respects.

BOQ

Sl. No. Item TitleItem Description
11000A ACB Incomer LT Panel: Metal-enclosed LT Panel comprising and outgoing feeders consisting of 4 Nos. 630A 4 Pole MCCBs 1 No. 125A 4 Pole MCCBs, 2 Nos. 63A 4 Pole MCCBs, 2 Nos. 40A 4 Pole MCBs, 2 Nos. 32A 4 Pole MCBs and 2 Nos. 4 Pole MCBs, suitable for 415V AC, 50Hz, 3 Phase, 4 Wire system, complete with 1250A electrolytic aluminium busbars, 1250/5A CTs, Class 0.5S Multifunction Energy Meter, Under Voltage & Over Voltage Protection Relay, RYB phase indication lamps, ON/OFF/TRIP indication lamps, control MCBs, panel heater, panel exhaust fan, Panel Light, FRLS control wiring, cable alleys, removable Top/Bottom entry with gland plates, earthing terminals and MS panel base frame. The 1000A ACB incomer shall be provided with a microprocessor-based electronic LSIG trip unit, motorized spring charging mechanism, closing coil, shunt trip coil, under-voltage release, auxiliary contacts, draw-out cradle assembly and safety shutters, having a minimum short-circuit breaking capacity of 50kA at 415V AC, suitable for reliable protection, isolation and switching of low- voltage power distribution system. The panel shall conform to IS/IEC 61439-1, IS/IEC 61439-2 and IS/IEC 60947-2, complete in all respects.[ ALL MCCB WITH SPREADER LINKS AND ROTARY HANDLE]LT Enclosure panel along with 4 pole 1000 Ampere ACB, Dust Proof, Vermins Proof, Cubical Design Modular, Floor Mounted Indoor, Plate Provision, 3Phase 4 wire 415V, 50 Hz.1000A ACB Incomer LT Panel: Metal-enclosed LT Panel comprising and outgoing feeders consisting of 4 Nos. 630A 4 Pole MCCBs 1 No. 125A 4 Pole MCCBs, 2 Nos. 63A 4 Pole MCCBs, 2 Nos. 40A 4 Pole MCBs, 2 Nos. 32A 4 Pole MCBs and 2 Nos. 4 Pole MCBs, suitable for 415V AC, 50Hz, 3 Phase, 4 Wire system, complete with 1250A electrolytic aluminium busbars, 1250/5A CTs, Class 0.5S Multifunction Energy Meter, Under Voltage & Over Voltage Protection Relay, RYB phase indication lamps, ON/OFF/TRIP indication lamps, control MCBs, panel heater, panel exhaust fan, Panel Light, FRLS control wiring, cable alleys, removable Top/Bottom entry with gland plates, earthing terminals and MS panel base frame. The 1000A ACB incomer shall be provided with a microprocessor-based electronic LSIG trip unit, motorized spring charging mechanism, closing coil, shunt trip coil, under-voltage release, auxiliary contacts, draw-out cradle assembly and safety shutters, having a minimum short-circuit breaking capacity of 50kA at 415V AC, suitable for reliable protection, isolation and switching of low- voltage power distribution system. The panel shall conform to IS/IEC 61439-1, IS/IEC 61439-2 and IS/IEC 60947-2, complete in all respects.[ ALL MCCB WITH SPREADER LINKS AND ROTARY HANDLE]LT Enclosure panel along with 4 pole 1000 Ampere ACB, Dust Proof, Vermins Proof, Cubical Design Modular, Floor Mounted Indoor, Plate Provision, 3Phase 4 wire 415V, 50 Hz.
2Aluminium Armoured Cable XLPE type Size: 3.5 CoreX300 sqmm.Aluminium Armoured Cable XLPE type Size: 3.5 CoreX300 sqmm.
3Heavy Duty Hot Dip Galvanized (HDG) perforated cable tray of size 300 mm width × 75 mm height with minimum 2 mm thickness, complete with matching GI cover, couplers/jointers, angle mounting supports,fasteners, and threaded GI stud rods,as per IS Standard.Heavy Duty Hot Dip Galvanized (HDG) perforated cable tray of size 300 mm width × 75 mm height with minimum 2 mm thickness, complete with matching GI cover, couplers/jointers, angle mounting supports,fasteners, and threaded GI stud rods,as per IS Standard.
4Double Compression gland suitable for 3.5Cx300 sqmm Aluminium Armoured Cable XLPE typeDouble Compression gland suitable for 3.5Cx300 sqmm Aluminium Armoured Cable XLPE type
5Aluminium Lugs Size: 300 sqmmAluminium Lugs Size: 300 sqmm
6Aluminium Lugs Size: 185 sqmmAluminium Lugs Size: 185 sqmm
7Maintenance-free GI Chemical Plate Earthing comprising 600 mm × 600 mm × 6 mm hot dip galvanized GI plate electrode with approved conductive chemical backfill compound, complete with 25 mm × 6 mm HDG GI earth strip, GI watering pipe with funnel (where required), test link, brick masonry earth chamber with heavy-duty CI/RCC cover, excavation, backfilling, all accessories and interconnections, complete to achieve earth resistance as per IS 3043:2018Maintenance-free GI Chemical Plate Earthing comprising 600 mm × 600 mm × 6 mm hot dip galvanized GI plate electrode with approved conductive chemical backfill compound, complete with 25 mm × 6 mm HDG GI earth strip, GI watering pipe with funnel (where required), test link, brick masonry earth chamber with heavy-duty CI/RCC cover, excavation, backfilling, all accessories and interconnections, complete to achieve earth resistance as per IS 3043:2018
8GI Earthing Strips Size:25 mm × 6 mm Hot Dip Galvanized (HDG) GI Earthing Strip conforming to IS 2062 and hot-dip galvanized as per IS 4759GI Earthing Strips Size:25 mm × 6 mm Hot Dip Galvanized (HDG) GI Earthing Strip conforming to IS 2062 and hot-dip galvanized as per IS 4759
9CABLE TIE 300 MMCABLE TIE 300 MM
10PVC Tape Colour( R,Y,B,N & Green)PVC Tape Colour( R,Y,B,N & Green)
11Supply, installation, testing and commissioning of 1000A, 4-Pole, draw-out type ACB, 415V AC, 50Hz, minimum 50kA Icu at 415V, with electronic LSIG trip unit, motorized spring charging, closing coil, shunt trip, under-voltage release, auxiliary contacts, draw-out cradle and safety shutters, complete with all accessories as per IS/IEC 60947-2.The scope shall include modification of existing LT panel, ACB mounting arrangement, busbar modification/extension with suitable rated links and supports, insulation barriers, CTs, multifunction energy meter, indication lamps, control MCBs, FRLS control wiring, terminal blocks, earthing, gland plates, labels and all necessary hardware/consumables.Complete work shall include testing and commissioning, including insulation resistance, contact resistance, primary/secondary injection and functional testing of ACB protection and accessories. The modified LT panel assembly shall comply with IS/IEC 61439-1 and IS/IEC 61439-2, complete in all respects.Supply, installation, testing and commissioning of 1000A, 4-Pole, draw-out type ACB, 415V AC, 50Hz, minimum 50kA Icu at 415V, with electronic LSIG trip unit, motorized spring charging, closing coil, shunt trip, under-voltage release, auxiliary contacts, draw-out cradle and safety shutters, complete with all accessories as per IS/IEC 60947-2.The scope shall include modification of existing LT panel, ACB mounting arrangement, busbar modification/extension with suitable rated links and supports, insulation barriers, CTs, multifunction energy meter, indication lamps, control MCBs, FRLS control wiring, terminal blocks, earthing, gland plates, labels and all necessary hardware/consumables.Complete work shall include testing and commissioning, including insulation resistance, contact resistance, primary/secondary injection and functional testing of ACB protection and accessories. The modified LT panel assembly shall comply with IS/IEC 61439-1 and IS/IEC 61439-2, complete in all respects.
12SITC of 1250A electrolytic aluminium input and output busbars for connection of the 1000A ACB with the existing LT panel, complete with suitable high-strength busbar supports/insulators, jointing hardware, flexible/rigid links, insulation sleeves/barriers and all necessary accessories, including fabrication, cutting, drilling, bending, installation, jointing, testing and commissioning, suitable for the required short-circuit withstand and complying with IS/IEC 61439-1 & IS/IEC 61439-2, complete in all respects.SITC of 1250A electrolytic aluminium input and output busbars for connection of the 1000A ACB with the existing LT panel, complete with suitable high-strength busbar supports/insulators, jointing hardware, flexible/rigid links, insulation sleeves/barriers and all necessary accessories, including fabrication, cutting, drilling, bending, installation, jointing, testing and commissioning, suitable for the required short-circuit withstand and complying with IS/IEC 61439-1 & IS/IEC 61439-2, complete in all respects.
13Supply, fabrication, installation, testing and commissioning of CRCA sheet steel enclosure for extension of existing LT panel, cubicle type, size 2200(H) × 1100(W) × 1400(D) mm, complete with suitable MS angle base frame/stand, hinged and lockable doors, removable gland plates, cable alley, ventilation provisions, panel exhaust fan with thermostat and panel heater with thermostat, earthing terminals, internal supports and hardware, suitable for accommodating 1000A, 4-Pole ACB incomer. The scope shall also include SITC of 1250A electrolytic aluminium input and output busbars, complete with suitable busbar supports, insulators, links, jointing hardware, sleeves/insulation barriers and connections to the existing LT panel busbars. The enclosure and modified panel assembly shall comply with IS/IEC 61439-1 & IS/IEC 61439-2, and the ACB shall comply with IS/IEC 60947-2, complete in all respects.Supply, fabrication, installation, testing and commissioning of CRCA sheet steel enclosure for extension of existing LT panel, cubicle type, size 2200(H) × 1100(W) × 1400(D) mm, complete with suitable MS angle base frame/stand, hinged and lockable doors, removable gland plates, cable alley, ventilation provisions, panel exhaust fan with thermostat and panel heater with thermostat, earthing terminals, internal supports and hardware, suitable for accommodating 1000A, 4-Pole ACB incomer. The scope shall also include SITC of 1250A electrolytic aluminium input and output busbars, complete with suitable busbar supports, insulators, links, jointing hardware, sleeves/insulation barriers and connections to the existing LT panel busbars. The enclosure and modified panel assembly shall comply with IS/IEC 61439-1 & IS/IEC 61439-2, and the ACB shall comply with IS/IEC 60947-2, complete in all respects.

AI Tender Summary

OUR REF NO 58343769
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 24-11-2026
Authority
Authority Name Department Of Heavy Industry
Work Description Bids Are invited for Supply, Installation, Testing Commissioning (Sitc) Of Electrical Panel For Ev Evse Test Setup - 1000A Acb Incomer Lt Panel: Metal-Enclosed Lt Panel Comprising And Outgoing Feeders Consisting Of 4 Nos. 630A 4 Pole Mccbs 1 No. 125A 4 Pole Mccbs, 2 Nos. 63A 4 Pole Mccbs, 2 Nos. 40A 4 Pole Mcbs, 2 Nos. 32A 4 Pole Mcbs And 2 Nos. 4 Pole Mcbs, Suitable For 415V Ac, 50Hz, 3 Phase, 4 Wire System, Complete With 1250A Electrolytic Aluminium Busbars, 1250/5A Cts, Class 0.5S Multifunction Energy Meter, Under Voltage & Over Voltage Protection Relay, Ryb Phase Indication Lamps, On/Off/Trip Indication Lamps, Control Mcbs, Panel Heater, Panel Exhaust Fan, Panel Light, Frls Control Wiring, Cable Alleys, Removable Top/Bottom Entry With Gland Plates, Earthing Terminals And Ms Panel Base Frame. The 1000A Acb Incomer Shall Be Provided With A Microprocessor-Based Electronic Lsig Trip Unit, Motorized Spring Charging Mechanism, Closing Coil, Shunt Trip Coil, Under-Voltage Release, Auxiliary Contacts, Draw-Out Cradle Assembly And Safety Shutters, Having A Minimum Short-Circuit Breaking Capacity Of 50Ka At 415V Ac, Suitable For Reliable Protection, Isolation And Switching Of Low- Voltage Power Distribution System. The Panel Shall Conform To Is/Iec 61439-1, Is/Iec 61439-2 And Is/Iec 60947-2, Complete In All Respects.[ All Mccb With Spreader Links And Rotary Handle]Lt Enclosure Panel Along With 4 Pole 1000 Ampere Acb, Dust Proof, Vermins Proof, Cubical Design Modular, Floor Mounted Indoor, Plate Provision, 3Phase 4 Wire 415V, 50 Hz. , Aluminium Armoured Cable Xlpe Type Size: 3.5 Corex300 Sqmm. , Heavy Duty Hot Dip Galvanized (Hdg) Perforated Cable Tray Of Size 300 Mm Width × 75 Mm Height With Minimum 2 Mm Thickness, Complete With Matching Gi Cover, Couplers/Jointers, Angle Mounting Supports,Fasteners, And Threaded Gi Stud Rods,As Per Is Standard. , Double Compression Gland Suitable For 3.5Cx300 Sqmm Aluminium Armoured Cable Xlpe Type , Aluminium Lugs Size: 300 Sqmm , Aluminium Lugs Size: 185 Sqmm , Maintenance-Free Gi Chemical Plate Earthing Comprising 600 Mm × 600 Mm × 6 Mm Hot Dip Galvanized Gi Plate Electrode With Approved Conductive Chemical Backfill Compound, Complete With 25 Mm × 6 Mm Hdg Gi Earth Strip, Gi Watering Pipe With Funnel (Where Required), Test Link, Brick Masonry Earth Chamber With Heavy-Duty Ci/Rcc Cover, Excavation, Backfilling, All Accessories And Interconnections, Complete To Achieve Earth Resistance As Per Is 3043:2018 , Gi Earthing Strips Size:25 Mm × 6 Mm Hot Dip Galvanized (Hdg) Gi Earthing Strip Conforming To Is 2062 And Hot-Dip Galvanized As Per Is 4759 , Cable Tie 300 Mm , Pvc Tape Colour( R,Y,B,N & Green) , Supply, Installation, Testing And Commissioning Of 1000A, 4-Pole, Draw-Out Type Acb, 415V Ac, 50Hz, Minimum 50Ka Icu At 415V, With Electronic Lsig Trip Unit, Motorized Spring Charging, Closing Coil, Shunt Trip, Under-Voltage Release, Auxiliary Contacts, Draw-Out Cradle And Safety Shutters, Complete With All Accessories As Per Is/Iec 60947-2.The Scope Shall Include Modification Of Existing Lt Panel, Acb Mounting Arrangement, Busbar Modification/Extension With Suitable Rated Links And Supports, Insulation Barriers, Cts, Multifunction Energy Meter, Indication Lamps, Control Mcbs, Frls Control Wiring, Terminal Blocks, Earthing, Gland Plates, Labels And All Necessary Hardware/Consumables.Complete Work Shall Include Testing And Commissioning, Including Insulation Resistance, Contact Resistance, Primary/Secondary Injection And Functional Testing Of Acb Protection And Accessories. The Modified Lt Panel Assembly Shall Comply With Is/Iec 61439-1 And Is/Iec 61439-2, Complete In All Respects. , Sitc Of 1250A Electrolytic Aluminium Input And Output Busbars For Connection Of The 1000A Acb With The Existing Lt Panel, Complete With Suitable High-Strength Busbar Supports/Insulators, Jointing Hardware, Flexible/Rigid Links, Insulation Sleeves/Barriers And All Necessary Accessories, Including Fabrication, Cutting, Drilling, Bending, Installation, Jointing, Testing And Commissioning, Suitable For The Required Short-Circuit Withstand And Complying With Is/Iec 61439-1 & Is/Iec 61439-2, Complete In All Respects. , Supply, Fabrication, Installation, Testing And Commissioning Of Crca Sheet Steel Enclosure For Extension Of Existing Lt Panel, Cubicle Type, Size 2200(H) × 1100(W) × 1400(D) Mm, Complete With Suitable Ms Angle Base Frame/Stand, Hinged And Lockable Doors, Removable Gland Plates, Cable Alley, Ventilation Provisions, Panel Exhaust Fan With Thermostat And Panel Heater With Thermostat, Earthing Terminals, Internal Supports And Hardware, Suitable For Accommodating 1000A, 4-Pole Acb Incomer. The Scope Shall Also Include Sitc Of 1250A Electrolytic Aluminium Input And Output Busbars, Complete With Suitable Busbar Supports, Insulators, Links, Jointing Hardware, Sleeves/Insulation Barriers And Connections To The Existing Lt Panel Busbars. The Enclosure And Modified Panel Assembly Shall Comply With Is/Iec 61439-1 & Is/Iec 61439-2, And The Acb Shall Comply With Is/Iec 60947-2, Complete In All Respects.
Basic Detail
Tender No GEM/2026/B/8231572
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 03 Nov 2026
Submission Date 24 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 48000
Exemption Not Available
Document List
964ca62b-1b2d-44b4-bf59-b7c5bd316b86.pdf
1793682704.xlsx
technical_specification_2026-11-02-17-19-50_37b76efe33a4838066000c0b109d8309.pdf
ATC_883a700a-bcf2-41d3-b58f1793683648667_arvind.kr.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
pdf

964ca62b-1b2d-44b4-bf59-b7c5bd316b86.pdf

xlsx

1793682704.xlsx

pdf

technical_specification_2026-11-02-17-19-50_37b76efe33a4838066000c0b109d8309.pdf

kr

ATC_883a700a-bcf2-41d3-b58f1793683648667_arvind.kr.pdf

Disclaimer