Housing Urban and Rular Development Government Departments Closing in 7 days TDR #58343597

Tender For Camc Of Fire Fighting System At Cancer Hospital, Pratap Nagar, Jaipur

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
5.69 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
7 days left
EMD
11380
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Camc Of Fire Fighting System At Cancer Hospital, Pratap Nagar, Jaipur

BOQ

Name of Work:- CAMC of Fire Fighting System at Cancer Hospital, Pratap Nagar, Jaipur
Sl. No. Item Description
1All in all comprehensive maintenance of fire protection system including jockey Pump , main motor pump , terrace pump , Diesel pump , water sprinkles pipelines ,wet /dry risers , various type of valves , over head / under ground water tanks , First aid hose reels , Indoor / out door hydrants , air vessels , hose pipes , branch pipes , hose cabinets , control panel , all type of fire extinguishers , battery charger ,wiring/cabling etc complete in all respect.( excluding replacement of battery and refilling of fire extinguishers .)
22280 /2250 LPM, 88 Mtr Head main pump fire station
3All in all comprehensive maintenance of microprocessor based addressable firedetection control system including control panel , repeater panel, all types ofdetectors & devices (total 125 Nos) , fault isolation module , manual call point ,response indicators , speakers/hooters . PA system , wiring/cabling etc completein all respect as per OEM's recommendations / guide lines to put the systemhealthy and functional
4Providing experienced and Highly skilled/skilled/ semi-skilled/Un Skilled labourfor electric repair/ maintenance / operation of Air conditioning/Air cooling/Firefighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as perrequirement (one shift of 8 Hrs per day for 26 Working Days in a month)
5Highly skilled Labour
6Skilled Labour
7Un Skilled labour
8Add for extra working on Holidays.
9Highly skilled Labour
10Skilled Labour
11Un Skilled labour
12Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications including cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of required shade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
13100 mm dia
14150 mm dia
15Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick), nuts, bolts, washers, gaskets, etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
16Single Headed with 75 mm Dia. Flanged Inlet
17Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A) 63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304 male and female couplings (IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.
18Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required. (A) Thermoplastic / Rubber Hose (B)20 mm dia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall. (D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1 through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
19With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969 and Bursting pressure 42 Kg/sqcm
20Supplying and Fixing of PN 1.6 Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
21100 mm dia
22150 mm dia
23Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
24150 mm dia
25Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
26Three phase Ammeter with Inbuilt Selector Switch
27Three phase Voltmeter with Inbuilt Selector Switch
28Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
29Red/yellow/Green colour Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58343597
AUTHORITY Government Departments
TENDER VALUE 5.69 Lakhs
LAST DATE 12-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Camc Of Fire Fighting System At Cancer Hospital, Pratap Nagar, Jaipur
Basic Detail
Tender No EE_DIV2_NIT_28_2026_27
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 03 Nov 2026
Submission Date 12 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 5.69 Lakhs
Tender Fee 500
EMD 11380
Exemption Available
Document List
04conditions.pdf
BOQ_1073388.xls
e9ee2fff-72da-4b88-8c27-58f15b9f6ed8.html
Schedulecover4.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

04conditions.pdf

xls

BOQ_1073388.xls

html

e9ee2fff-72da-4b88-8c27-58f15b9f6ed8.html

pdf

Schedulecover4.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender