Tender For construction Of Kantasahi-I & Bhanarnijigada-Iv Community Lift Irrigation Project (Medium/Deep Tube Well) Under Balipatna Block Of Khordha District Under Ridf 2026-27
Tender Overview
Project Description
Tender for construction Of Kantasahi-I & Bhanarnijigada-Iv Community Lift Irrigation Project (Medium/Deep Tube Well) Under Balipatna Block Of Khordha District Under Ridf 2026-27
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Nov-2026 | Corrigendum No.1391 Dt.02.11.2026 | Other | 16-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer in charge including use of own Rigs with its accessories, tools and plants and all consumables (like coir rope, cotton waste and bentonite powder etc. complete) etc. for lowering of finished bore suitable for lowering (minimum 400 mm dia.) of 200mm dia GI/PVC Pipe for housing fitted with sockets and with or without well screen as per the necessity for the soft medium, hard and boulder formations (. GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion ) including lower and withdrawing of casing pipes after drilling 200mm to 400mm dia in over burden portion etc complete as per the Engineer-in-charge.Drilling of 400 X 200 mm dia Tube Well for lowering of 200 mm dia casing pipe upto 100 metre depth |
| 2 | Cost, Supplying of ISI marked scheduled-80 Casing pipes as per ASTM-D-1785/2021 of 200 mm Nominal diameter including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST etc complete as per the Engineer-in-charge. |
| 3 | Supply of all Labour & T&P for lowering the following sizes of PVC Pipes with or without slotted pipes as per the necessity from ground level & fitted & fixed up in perfectly verticaly position inlcuding cutting & threading pipe and slotted pipe and fixing all jointing materials etc, complete. and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fitting & joining materials. 200mm dia PVC Casing pipes |
| 4 | Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipments and labour as per the direction of Engineer-in-charge. |
| 5 | Supplying all materials, Labour T & P for logging the bore through departmental logging team (Till logging team arrives at site the contractor is to keep the bore intact by circulating system) and when the logging team arrive at the site. The contractor will withdraw the drill rod with cutter etc, and keep the bore suitable for logging and supply required labour to carry out the logging opperation. |
| 6 | Supplying all materials, Labour T&P for packing the bore with washed gravel size (P-6) arround the well screen and pipes in good quality including cost of gravel, conveyance, royality, etc complete as per direction of Engineer-in-charge. (120 mtr depth) = 0.786 x (0.4² - 0.2²) x 120 mtrs = 11.32 say 11.50 cum |
| 7 | Labour charges for cutting transverse slot on 200mm Ø PVC casing pipe with slot size 1.5 mm as per specification, direction of Engineer-in-charge. |
| 8 | 200mm dia pvc casing pipe threading chargesas including all cost etc complete, as per direction of Engineer-in-charge. |
| 9 | Cost of Supplying 200mm PVC threaded bail plug including all cost etc complete, as per the direction of Engineer-in-charge. |
| 10 | Cost of Supplying 8\\" PVC threaded end cap including all cost etc complete, as per the direction of Engineer-in-charge. |
| 11 | Cost of Supplying 200mm x 300 mm long PVC short piece including all cost etc complete, as per the direction of Engineer-in-charge. |
| 12 | Cost of Supplying 200 mm dia rubber 'O' ring aincluding all cost etc complete, as per the direction of Engineer-in-charge. |
| 13 | Cost of Supplying Silicon Sealant(Anabond) as per the direction of Engineer-in-charge. |
| 14 | Excavation in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels, within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods and stacking rubble or spreading and leveling within the site as the case may be etc; complete.asper direction of the Engineer-in-charge.(Mechanical 60% & Mannual 40%) |
| 15 | Earth work excavation of foundation in hard soil within initial lead of 50m & lift of 1.5m including dressing and levelling the bed etc. |
| 16 | Filling in F&P with excavated materials including well watered and rammed.in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels, within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods and stacking rubble or spreading and leveling within the site as the case may be etc; complete.asper direction of the Engineer-in-charge.(Mechanical plus mannual i.e. of item No. 1 above) |
| 17 | Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-incharge.(i.e. of item No. 2 above) |
| 18 | Filling in foundation and plinth with sand including watering and ramming etc complete as per the direction of the Engineer-incharge. |
| 19 | Cement concrite(1:4:8) with 4cm size h.g.b. crusser broken metal of approved quality from approved quarry with ramming watering and curring etc.complete including cost , taxes, royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 20 | Brick work with flyash Bricks 25cm x 12cm x 8cm size having croshing strength not less than 100kg/cm2 to149kg/cm2 with dimensional tolerrance± 8% in cement morter (1:6) in foundation and plinth etc. complete as per the Engineer-incharge. |
| 21 | Brick work with flyash Bricks 25cm x 12cm x 8cm size having croshing strength not less than 100kg/cm2 to149kg/cm2 with dimensional tolerrance± 8% in cement morter (1:6) in superstructure work etc. complete as per the Engineer-incharge. |
| 22 | 12mm thick cement plaster in cement morter(1:6)finished smooth to brick work after racking out joints including watering and curring etc.complete including cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-in-charge. |
| 23 | R.C.C work for Roof slab of M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 24 | R.C.C work for Lintels and chajja of M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 25 | R.C.C work for Foundation,plinth band and footings bases of column mass concrete pre cast slabsof M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 26 | R.C.C work for beams,columns, of M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 27 | R.C.C work for walls and fins of M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 28 | Cost of suplying HYSD steel bars for R.C.C. work including Labour charges for cutting, bending,binding,Straightening and laying grills and placing in position including cost of binding wire 18 to 20 gauge |
| 29 | Cement punning over plastering including watering & curing with cost, taxes, royality & conveyance charges of all materials & supply of all materials & T& P etc complte as per direction of Engineer- in - charge. |
| 30 | 2.5cm A.S. flooring with C.C.(1:2:4) including punning with 12mm size chips. |
| 31 | 20 mm thick grading plaster with cement mortar (1:4 ) finished smooth to the roof surface etc complete. |
| 32 | Cost , supplying, fabricatio, fixing of MS Double leaf Door of size (1.05 mx2.00m) made out of M.S.Frame (35mmx35mmx5mm) with G.P.Sheet pannel of 1.20 mm thick and MS Window of size (0.90mx1.20m) made out of M.S.Frame (30mm x30mm x5mm) with G.P.Sheet pannel of 1.20mm thick including fitting at site with all cost etc. complete as per direction of Engineer in charge. |
| 33 | Finishing walls with water proofing cement paint two coats over a coat of primer of approved shade on new work to give an even shade including cost of cement paint & primer, labour etc complete. |
| 34 | Painting two coats with enamel paint over a coat of red oxide primer for priming over iron work including cost of paint & labour etc complete. |
| 35 | Writing charge of required information and data on both side of the transperancy pillar & pump chamber including supplying of approved paints and required material for writing etc. complete. |
| 36 | Cost, supplying of all material, labour for internal wiring of pump chamber with all cost of wiring materials, labour etc complete. |
| 37 | Cost,Supplying of small T & P materials suitable for operation and maintainance of pumpsets and electrical devices of LI Projects of approved make including all cost,taxes etc. and handing over to PaniPanchayts (Sly wrench, DE & Ring spanner set ,Screw drivers set,Hand glooves, Godrej make 6 lever lock etc. complete.) |
| 38 | Laying and Fitting of 200 mm outer dia High Density Polythylene (HDPE) Pipes of specified material grade & pressure rating by butt fusion welding method as per speciication & laying in tranches including testing & all cost etc fitting & fixing of required nos. of HDPE Teee for outlet & shaddle & G.I. raiser, nipple for fitting of air valve, equal Tee etc. complete as per direction of Engineer - in-charge. |
| 39 | Laying and Fitting of 160 mm outer dia High Density Polythylene (HDPE) Pipes of specified material grade & pressure rating by butt fusion welding method as per speciication & laying in tranches including testing & all cost etc fitting & fixing of required nos. of HDPE Teee for outlet & shaddle & G.I. raiser, nipple for fitting of air valve, equal Tee etc. complete as per direction of Engineer - in-charge. |
| 40 | Labour charges for Installation of 10 HP/7.5HP Submerssible pump Sets including fitting , fixing ,Nut and bolt ,Rubber insertion etcof base frame, fitting & fixing suction and delivery pipe to motor,NR Valve, Foot valve, Sluice valve and other fitting materials including cutting, welding and etc. including transportation to project site and site clearance etc. complete as per the direction of the Engineer-incharge. |
| 41 | Fabrication of special joint including cutting and welding of pipes out of M.S. pipe / 100mm dia G.I.pipe including welding charges etc. complete. |
| 42 | Labour for fitting and fixing of HDPE pipe short pieces in vent of outlet tanks along the rising main/lateral pipelines. |
| 43 | Cost, Supplying of - 200mm Ø HDPE Pipe PE 80- PN 4 ISI marked High Density Polythelene (HDPE) Pipes for water supply as per IS 4984/2016 Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST |
| 44 | Cost, Supplying of - 160mm Ø HDPE Pipe PE 80- PN 4 ISI marked High Density Polythelene (HDPE) Pipes for water supply as per IS 4984/2016 Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST |
| 45 | Cost,supplying of-100mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr.Each pipe should bear IS certification and manufacturers name/trade mark. |
| 46 | Cost,supplying of- 100mm dia G.I.Bend (Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 47 | Cost,supplying of-100mm dia G.I.Socket (Medium Duty) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 48 | Cost,supplying of- 100mm dia G.I.Flange (Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 49 | Cost,supplying of--7.5 HP/5.62 KW Energy efficiency Submersible pumpset of total head 25 mtr having 900 LPM discharge of reputed brand with BEE 3 Star rated energy efficiency suitable for 200 mm dia tube well as per IS specification with 2 pair U-Clamp & 30 mtr of 4.00 sqmm flat cable and Impeller: Bronze grade LTB-2 of IS 318/1981 confirming to IS specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 50 | Cost,supplying of-100mm dia C.I.Double Flanged Non Return Valve swing type PN-1.0 (IS-5312(Part-I-2004) with bypass arrangement with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 51 | Cost,supplying of-100mm dia C.I.Sluice Valve Flanged type PN-1.0 as per (IS-14846-2000 Standard) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 52 | Cost,supplying of-150X100 mm dia G.I.Reducing Socket with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 53 | Cost, Supplying of Cost, supplying of 50mm dia Kirloskar make C.I double Air Release Valve PN 1.6 with saddle and Raiser pipe conforming to IS 14845 (SI) with ISI mark including all cost, conveyance, cess etc complete but excluding cost of GST |
| 54 | Cost, Supplying of 150mm dia C.I. Butter Fly Valve BS:5155/15: Kirloskar or equivalent make 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed including all cost, conveyance, cess etc complete but excluding cost of GST |
| 55 | Cost, Supplying of 200 mm HDPE elbow spigot design 6 Kg mm diameter bend ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 56 | Cost, Supplying of 160 mm HDPE elbow spigot design 6 Kg mm diameter bend ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 57 | Cost, Supplying of 200X 160 mm HDPE reducer ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 58 | Cost, Supplying of 200 mm slipon flange ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply of different nominal diameter as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 59 | Cost, Supplying of 160 mm slipon flange ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply of different nominal diameter as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 60 | Cost, Supplying of - 200 MM HDPE Tail piece 160 mm long ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 61 | Cost, Supplying of - 160 MM HDPE Tail piece 160 mm long ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 62 | Cost, Supplying of 200X200X160 mm HDPE Reducing Tee spigot design 10 kg ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 63 | Cost, Supplying of 160X160X160 mm HDPE Tee spigot design 6 kg ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST - |
| 64 | Cost, Supplying of - 200 MM HDPE End cap ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 65 | Cost, Supplying of - 160 MM HDPE End cap ISI marked HDPE pipe fitting materials for High Density Polythelene (HDPE) Pipes for water supply as per ISI speifications including the rates of ex-factory, transportation, Cess etc complete but excluding cost of GST |
| 66 | Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 67 | Cost, supplying of Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt Meter, Ameter, MCB in complete shape including Indicator Lamp reputed brand of ISI specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 68 | Cost, supplying of 63 AMP Triple Pole Mainswith confirming to IS No.4064(Part I & II) with ISI marking of reputed company having utilisation capacity cagegory AC- 22 reputed brand of ISI specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 69 | Cost, supplying of 4KVAR Power Shunt Capacitor with ISI mark of of reputed approved brand of ISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 70 | Cost, supplying of 200X100mm dia M.S.T/W Cap with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 71 | Cost,supplying of 100 mm dia MS Tube well Clamp (One pair) including all cost, conveyance, cess etc complete as per the direction of the Engineer-In-Charge but excluding cost of GST |
| 72 | Cost,supplying of T.W. safe guard including all cost, conveyance, cess etc complete as per the direction of the Engineer-In-Charge but excluding cost of GST |
| 73 | Cost, supplying of 12mm dia PVC insulated steel bar rope including ll cost, conveyance, cess etc complete as per the direction of the Engineer-In-Charge but excluding cost of GST |
| 74 | Cost,supplying of 4.0 mm2 Submerssible (3 Core) Flat Cable ISI mark of reputed brand of ISI specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 75 | Cost, supplying of 3x10 sqmm PVC insulated (HD) tropoder armoured Electric Cable with alluminum conductor for use in 3 phase power system of working voltage upto & including 1100 volts at 50Hz confirming to IS 7098 (Pt-II) of approved brand of ISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 76 | Electrical installation with electrical materials such as PVC tape, Ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, GI flexible conduite pipe, No. 6 GI wire, Copper cable socket, GI socket and flange and petty materials required for electrical installation.All materials should be as per IS |
| 77 | Electrical earthing including all materials complete as per the direction of the Engineer-incharge |
| 78 | Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation with 5mtrx3mtrx1.5mtr height mesonary toe wall /G.I. Flat fencing boundary wall with Flat with Polymer insulator ,L.T Dist Box with MCCB , Aluminim bus bar of single bay with kitkat fuse , sand filling and metal spearding with M.S.Grill gate ,all Channel matrials should be G.I , 7 Nos earthing with chamber with 3mtr G.I pipe of 40mm dia with connecting of 25mmx 5mm G.I flat to all earthing including 25KVA BIS Leble-II Star rated Transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm G.I.Channel, Transformer belting on 2.80 M long 50mm X 50mm X 5 mm G.I.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75mm X 40mm X 6 mm G.I.Channel and supported by 1.0 M long 50 X 50 X 5 mm G.I.Angle, with 3 No. 11 KV Lightening Arrestors and Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets as per TPCOCL specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning, SITC and Erection of GI fencing/ brick masonary boundary wall 16 running metre with grill gate etc. complete but excluding cost of 6% supervision & inspection chargesas per specification of TPCODL etc complete. |
| 79 | Construction of 3 phase 11 KV HT line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm AAA Conductor average span 40mtr , 11 KV \\"V\\" Cross arm required No.of 11 KV T & C Disc. polymer Insulators in tension point & 11 KV Pin Polymer insulators, Couping & Padding of Poles with all G.I.Channels. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc if required including cost of all materials, labour, transportation, erection & commissioning, earthing with chamber etc complete. |
| 80 | Construction of 3 Phase L.T line as per REC standard confirming to RE rule 1956 with 300 Kg 8 Mtr long PSC pole support in 0.33M span length with 3x35mm² +1x25 mm ² LT, XLPE AB cable with coil earthing device, LT dead end clam, Suspension clamp with G I hook , stay accessories such as wire insulator , clamp etc. nut bolts, alongwith concreting copping & padding of poles and stayset as per direction of Engineer in Charge. |
| 81 | 11 KV Line 90 Degree Cut Point including cost of all materials, labour transportation,inspection & commissioning etc. complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender