Public Administrative Department Government Departments Closing in 5 days TDR #58341790

Tender For Improvement Of Water Distribution Network At Manikpur (Part) Block (Id- 1026, Activity Code-126153684)

Issued by Government Departments · Bongaigaon, Assam
Tender Value
43.47 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
5 days left
EMD
86954
Bank guarantee accepted
Document Fee
1350
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bongaigaon → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Improvement Of Water Distribution Network At Manikpur (Part) Block (Id- 1026, Activity Code-126153684)

BOQ

Name of Work:- Improvement of Water Distribution Network at Manikpur (Part) Block (ID- 1026, Activity Code-126153684)
Sl. No. Item Description
1Odex/Reverse Odex: Providing installation and commissioning of 150 mm dia deep tubewell by Rotary Rig within the jurisdiction of different PHE divisions including preparation of site for placing of drilling rig, transportation of rig and ancillary equipments and drilling the DTW including extraction of drill pipes etc., lowering, fitting, fixing 150 mm diameter UPVC pipe assembly comprising of strainer, pipes and cone in potable water bearing strata, washing the bore well etc., supplying necessary jointing materials, developing the DTW with air compressor Make-Kirloskar/Cummins for a period of 24 hours and supplying and packing pea gravel of size 1/8” to 3/8” around the periphery of casing including screening, washing etc., all complete to the satisfaction of the department.
2Providing, laying, fitting & fixing GI (Medium Class) Pipe conforming to IS-1239 (Pt-I) 2004 (with up to date amendment) including ISI marked GI specials and jointing material, cutting of pipe materials and necessary earthwork in trenching and refilling of earth and restore to its original condition including dressing, dewatering including bailing out water where necessary all complete and also necessary testing and commissioning as per direction of the engineer in charge. 50 mm dia GI.
3Providing, installation and commissioning Solar submersible pump and Centrifugal pump (with different heads) with Power unit (Solar Modules), Controller, Module mounting Structure, Tracking (Manual Sun tracking system), 3 core cable, earthing, lighting protection, Civil work (excavation and installation of base for panels), miscellaneous accessories. Solar module cleaning system, all items conforming to relevant IS/IEC standards with warranty of 5 years and transportation to Guwahati Assam for the following capacity as directed by department and subjected to SOPs guidelines issued from department.2 HP + 3 HP
4Collection from the field and testing in the laboratory of undisturbed soil samples for sub-soil investigation (as per relevant I.S. code) by open drive sampler (100 mm dia boring) through clayey soil layer/sandy soil layer/sandy clay/sandy silt layer/clayey silt layer, conduction standard penetration test (SPT) and collection of SPT sampler, observation of ground water table, spot level survey to the bore location and carrying out R.L. from nearest B.M., laboratory test (particle size analysis, hydrometer test, determination of liquid limit, plastic limit, bulk density, moisture content, specific gravity, conducting triaxial test, direct shear test, unconfined compression test, consolidation test including preparation of sub-soil investigation report complete with necessary printing and binding (minimum 5 copies).
5Earthwork in excavation for foundation trenches of walls, retaining walls, footings of columns, steps, septic tank etc., including refilling (return filling) the quantity as necessary. After completion of work, breaking clods in return filling, dressing, watering and ramming etc., removal of surplus earth with all lead and lift as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00 m below existing ground level; (a) in ordinary soil.
6Providing brick soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid in panel after preparing the subgrade as directed including all labour and materials and, if necessary, dewatering complete. (a) Brick flat soling.
7Plain Cement Concrete work with coarse aggregate of size 13 mm to 32 mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including curing complete (shuttering where necessary will be paid and measured separately). In proportion 1:3:6.
8Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and lengths as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. No extra measurement for lap, hook, chair, anchor etc. will be entertained as included in the rate (up to first floor level).(ii) Super Ductile (SD) TMT reinforcement bars.
9(c) ISI approved Mild steel reinforcement bar (M.S. Bar).6 mm dia MS bar
10Providing formwork of ordinary timber planking or sheeting so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work.3.1.1.1 Foundation, footing, bases of columns, pile cap, raft and mass concrete works etc.; using 25 mm thick plank.
113.1.1.3 Column, pillar, post & struts; square, rectangular, polygonal or any shape (i) using 38 mm thick plank.
123.1.1.8 Vertical surface such as walls (any thickness), parapet walls, partition wall, retaining wall, wall of septic tank, inspection pit, culverts and like (i) using 38 mm thick plank
133.1.1.5 Flat surface such as soffits of suspended floors, roof, landing, cantilever slab, chajja etc., floors up to 200 mm thick; (i)using 38 mm thick plank.
14Providing and laying plain/reinforced cement concrete works, cement, coarse sand & 20 mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of formwork and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately).(i) Using Mixer Machine; (A) In substructure up to plinth level; foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, septic tank, inspection pit and other works not less than 100 mm thick up to plinth level.N) Without using admixture, plasticiser; d) M30 grade concrete.
15(B) In superstructure from plinth level up to 1st floor level.(i) Walls (thickness not less than 100 mm) including attached pilasters, buttresses, and string course etc.; (P) using admixture/plasticiser etc.; d) M30 grade concrete.
16(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing), including preparing the top surface and finishing of nosing; d) M30 grade concrete.
17(P) Without using admixture, plasticiser; a) M15 grade concrete or Prop. 1:2:4.
18Extra for providing and mixing normal plasticiser/plasticiser plus of Sikhna India Ltd. @ 200 gms per bag of cement in concrete for water proofing as specified and directed by the department at all levels.(ii) In 1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone) or M-20 grade.
19Brick work in cement mortar with 1st class brick including raking out joints and curing complete as directed.(b) In proportion 1:4 (1 cement:4 sand).
20Providing dressed wood work in post, walls, battens, post plate bressumers etc., including supplying and fixing with spikes, nails, bolt and nuts of 12 mm dia (M.S.) and required length etc. complete with kiricide oiling two coats to faces in contact with C.C. or masonry (M.S. flats, angle cleats and bolt and nuts required for flats, angle cleats wherever use shall be measured and paid separately).(e) With 2nd class treated timber.
21(a) Providing, fitting and fixing 1st class local wood battened, ledged and braced door and window shutters including oxidised iron butt hinges (100 mm x 58 mm x 1.90 mm), 6 nos with necessary screws.
2215 mm thick cement plaster in single coat on fair side of single or half brick/concrete wall for interior plastering up to first floor level including arises, internal rounded angles, not exceeding 80 mm in girth and finished even and smooth including curing complete as directed.A) On rough side; a) In cement mortar 1:3.
23(b) In proportion 1:4 outside.OHR
24Extra over item 6.2.1 to 6.2.3 for providing and mixing waterproofing materials in cement mortar in proper proportions as recommended by manufacturer including curing complete as directed.(ii) 15 mm thick plaster, (a) in cement mortar 1:3.
25(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and smooth and sand papered smooth.
26Finishing of new wall with waterproofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian paints of required shade after cleaning the surface etc., including scaffolding complete as directed at all levels (two coats).
27(c) Applying one coat of distemper primer of approved brand and manufacture on wall surface after thoroughly brushing the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and smooth and sand papered smooth.
28(g) Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade after thoroughly brushing the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and smooth and sand papered smooth.
29Labour charge for carrying, providing and fixing full way wheel valve of approved quality with supplying jointing materials all complete as directed. (g) 65 mm dia.
30Making provision for Ladder arrangement.
31CI D/F SLUICE VALVE WITH CAP/WHEEL AS PER IS 14846/2000 PN 1.0 WITH ISI MARKING; 100 mm dia sluice valve.
32Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap), C.I. reflex valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints), 100 mm dia.
33Supplying, laying, fitting & fixing HDPE pipes (High Density Poly Ethylene pipes PE 100) conforming to IS 4984/2016 (with up to date amendment) with necessary jointing material like mechanical connector or jointing pipes by heating the ends of pipes with help of Teflon coated electric mirror/heater to the required temperature and then pressing the ends together against each other to form a monolithic and leak proof joint by thermosetting process. It may be required to be done with jack/hydraulic jacks/butt fusion machine (50 mm & above fusion jointed & below 50 mm mechanically jointed). The HDPE fitting should be ISI marked conforming to relevant BIS code.(a) In CWPM (Inlet Pipe) b) Delivery pipe 63mm HDPE pipe
34c) Overflow & Backwash pipe 63mm dia HDPE pipe
35d) Waste water pipe 63mm dia HDPE pipe
36Lowering, laying and jointing H.D.P.E./M.D.P.E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevant IS code complete with all materials; 63 mm dia.
37Providing, fitting and fixing steel windows/ventilators (openable) of standard rolled steel sections as per relevant I.S. Code 1038 joints mitred and welded with 15 mm x 3 mm x 100 mm long embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65 mm and not less than 15 mm wide) bolting device and steel handles, peg stays of 300 mm long etc. complete as per drawing including applying a priming coat of red-lead paint.
38Providing Solar Power operated Aviation Warning Lamp with auto switching on/off devices at roof of the reservoir including supplying, fitting, fixing of all necessary accessories, all complete as directed and specified.
39Sand Gravel
40Supplying, fitting and fixing of lightning arrestor system at roof of the reservoir including conductor strip and 2 nos plate earth station etc. complete as directed and specified.
41SINTEX make Triple Wall Water Storage Tank of 5000 Ltrs capacity as per Code No. TLWS 750-01 TLW.
42Providing, laying, fitting & fixing GI (Medium Class) Pipe conforming to IS-1239 (Pt-I) 2004 (with up to date amendment) including ISI marked GI specials and jointing material, cutting of pipe materials and necessary earthwork in trenching and refilling of earth and restore to its original condition including dressing, dewatering including bailing out water where necessary, all complete and also necessary testing and commissioning as per direction of the engineer in charge.80 mm dia GI.
43Providing, installation, testing and commissioning of Bulk Flow Meter with removable mechanism class \\"B\\" confirming to ISO: 4064/1 including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipe line etc., complete in all respect as per technical specification and as per direction of Engineer.i) BFM80 for DN 80 mm
44Providing, laying, jointing & field testing of HDPE pipes (High Density Poly Ethylene Pipes—PE 100) conforming to IS 4984/2016 (with up to date amendment) with necessary jointing material like mechanical connector or jointing pipes by heating the ends of pipes with the help of Teflon-coated electric mirror/heater to the required temperature and then pressing the ends together against each other, to form a monolithic and leak-proof joint by thermosetting process. It may be required to be done with jack/hydraulic jacks/butt fusion machine. (50 mm & above fusion jointed & below 50 mm mechanically jointed.) The HDPE fitting should be ISI marked conforming to relevant BIS code. 110mm dia HDPE PN6
4590 mm dia HDPE PN6
4675 mm dia HDPE PN6
4763 mm dia HDPE PN6
48Constructing of Brick masonry Sluice Valve Chamber 750 mm (L) x 750 mm (B) x 1250 mm (H) inside, in 230 mm brick work in cement mortar 1:5 (1 cement : 5 coarse sand) and precast R.C.C cover slab in proportion 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), reinforced with 10 mm M.S. bar @ 150 mm centre both ways, tying with 20 gauge black annealed wire, including necessary earthwork (excavation and return filling), 75 mm PCC in proportion 1:4:8 (1 cement : 4 coarse sand : 8 coarse aggregate), brick flat soling and 15 mm thick inside plastering and outside plastering (up to 150 mm from top) with cement mortar 1:5 (1 cement : 5 coarse sand), complete as per standard design, including supplying, carrying, placing in position, fitting and fixing 80 mm diameter CI/DF sluice valve, all complete as directed. Approved good for construction drawing will be issued by the department.A) For 80 mm dia sluice valve against 90 mm / 75 mm dia distribution pipeline — 1 no. 80 mm dia CI/DF sluice valve.
49Constructing of Brick masonry Sluice Valve Chamber 900 mm (L) x 900 mm (B) x 1250 mm (H) inside, in 230 mm brick work in cement mortar 1:5 (1 cement : 5 coarse sand) and precast R.C.C cover slab in proportion 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), reinforced with 10 mm M.S. bar @ 150 mm centre both ways, tying with 20 gauge black annealed wire, including necessary earthwork (excavation and return filling), 75 mm PCC in proportion 1:4:8 (1 cement : 4 coarse sand : 8 coarse aggregate), brick flat soling and 15 mm thick inside plastering and outside plastering (up to 150 mm from top) with cement mortar 1:5 (1 cement : 5 coarse sand), complete as per standard design, including supplying, carrying, placing in position, fitting and fixing 100 mm / 125 mm / 150 mm diameter CI/DF sluice valve, all complete as directed. Approved good for construction drawing will be issued by the department.A) For 100 mm dia sluice valve against 110 mm dia distribution pipeline — 1 no. 100 mm dia CI/DF sluice valve with cap/wheel as per IS 14846-2000 PN 1.0.
50Providing Functional Household Tap Connection including earthwork in excavation for pipeline (both for connection in distribution line and service connection) and refilling, dressing etc.; providing PVC/HDPE Saddle Piece of average size 110 mm x 15 mm (i.e. ranging from 63 mm to 160 mm), making holes in the distribution pipe, providing 15 mm dia bronze ferrule cock (PN-16) conforming to IS:2692 (1989) as amended from time to time; flow control valve of SS316 with flow of 3 LPM at standard operating pressure of 0.5 bar to 1.5 bar of minimum weight 125 gm, connecting it to the saddle piece, providing and fixing 3 layer (Outer green/GREY coloured UV stabilised, middle black coloured UV Stabilised and inner most layer white coloured with anti microbial property) Fusion welded PP-R (Polypropylene-random co polymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 of average length 10 m from saddle piece to the standpost (pipes of make empanelled manufacturers and PN-16 Pipe, 20 mm OD, SDR-7.4), including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good the damages, including all taxes and duties as applicable and including the cost of all required labour and materials as directed and specified. The item also includes construction and installation of R.C.C Hydrant Pillar with cement concrete in proportion 1:2:4 sheathed in SWR pipe of dia 100 mm height 1200 mm encasing 15 mm dia PPR pipe inside the hydrant, inclusive of cost of transportation to site and also supplying, fitting and fixing PVC Bibcock all complete as directed and specified. Approved good for construction drawing will be issued by the department.
51Providing, laying, fitting & fixing GI (Medium Class) Pipe conforming to IS-1239 (Pt-I) 2004 (with up to date amendment) including ISI marked GI specials and jointing material, cutting of pipe materials and necessary earthwork in trenching and refilling of earth and restore to its original condition including dressing, dewatering including bailing out water where necessary, all complete and also necessary testing and commissioning as per direction of the engineer in charge.(a) 80 mm dia
52Supplying, fitting and fixing chain link fencing of 10 S.W.G. G.I. wire 50 mm x 50 mm mesh fitted to M.S angle iron post at 2000 mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I. wire 10 S.W. Gauge, middle and bottom and one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following:(a) Corner and end posts with M.S angle of size 50 mm x 50 mm x 5 mm and length not less than 1800 mm, only duly slotted and bottom torqued with two nuts as stay posts.(b) Intermediate post with M.S angle of size 40 mm x 40 mm x 5 mm and length not less than 1800 mm, only duly slotted and bottom torqued and splayed.(c) Stay post with M.S angle of size 35 mm x 35 mm x 5 mm and length not less than 1800 mm, duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600 mm.(d) Intermediate post with M.S angle of size 40 mm x 40 mm x 5 mm and length not less than 1800 mm, only duly slotted and bottom torqued and splayed.(e) Stay post with M.S angle of size 35 mm x 35 mm x 5 mm and length not less than 1800 mm, duly slotted and bottom torqued and splayed.
53Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50 mm x 6 mm M.S. flat iron with another horizontal flat at the middle, 20 mm dia M.S bars at 200 mm apart from bottom flat to top flat and 20 mm dia M.S bars at 200 mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100 mm above the top flat and top flat is to be flattened and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos. (minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts.)
54Raising low site around the Treatment Plant site with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royalty, sales tax, land compensation, municipal gate fees, if any, monthly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.
55Making sign board of size 3 m (W) x 1.2 m (H) with 50 mm MS square pipe supporting post in a frame of 32 mm MS square boundary pipes with 3 nos. 25 mm MS square strut pipe welded with a 3 mm thick MS plain sheet (3 m x 1.2 m), including foundation work, all complete as directed by the Engineer-in-charge.
56Providing flat brick soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level with plain cement concrete works with coarse aggregate of sizes 13 mm to 32 mm in proportion 1:3:6 with 15 mm thick cement plaster in single coat as directed by the Department.
57Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100 mm thick CC (1:3:6) base over one brick flat soling including 15 mm thick cement plastering in proportion 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.(i) 300 mm wide and average 150 mm deep with bed slope 1 in 150 with initial depth of 100 mm. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58341790
AUTHORITY Government Departments
TENDER VALUE 43.47 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Bodoland Territorial Council
Work Description Tender for Improvement Of Water Distribution Network At Manikpur (Part) Block (Id- 1026, Activity Code-126153684)
Basic Detail
Tender No BTDB/15th FC(Tender)/2026-27/18
Bidding Type Tender
Location
City Bongaigaon
State Assam
Key Dates
Publish Date 03 Nov 2026
Submission Date 24 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 43.47 Lakhs
Tender Fee 1350
EMD 86954
Exemption Available
Document List
BOQ_85774.xls
d47298ce-ac39-47b5-9a76-bdf4b5ff1278.html
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_85774.xls

html

d47298ce-ac39-47b5-9a76-bdf4b5ff1278.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender