Housing Urban and Rular Development Government Departments Closing in 4 days TDR #58341049

Tender For Supply And Installation Of Electrical Life Safety Equipment Such As Supply Installation Testing and Commissioning of Electrical Protection System, Spd And Earthing Protection System To All Panel Board And Rccb And Rcbo To All Db Box And Up

Issued by Government Departments · Ganjam, Odisha
Tender Value
49.83 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
4 days left
EMD
49900
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganjam → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply And Installation Of Electrical Life Safety Equipment Such As Supply Installation Testing and Commissioning of Electrical Protection System, Spd And Earthing Protection System To All Panel Board And Rccb And Rcbo To All Db Box And Upgradation Of Cable Laying Of Different Buildings Of Dhh, City Hospital At Berhampur In The District Of Ganjam.

BOQ

Name of Work:- Supply and Installation of Electrical life safety equipment such as SITC of Electrical protection system, SPD and earthing protection System to all Panel board and RCCB and RCBO to all DB Box and upgradation of cable laying of different buildings of DHH, City Hospital at Berhampur in the District of Ganjam.
Sl. No. Item Description
1Surge Protection Device for Power Line Protection: Supply and fixing Surge protection Device (SPD) Class- B, Type - I,Especially designed to handle Lightning Impulse current 10/350 s waveform. Connected in Main Incoming Panel - Three phase with neutral system (TT& TN-S System). Made of - Encapsulated /Non extinguising spark gap Technology, Impulse discharge current limp (10/350)s -50 (KA)/Pole and Maximum Discharge Current Imax 12.5 kA (10/350)s. Voltage protection level,Up <1.3 KV, Response time ta <100 ns, Operating temperature range -(-)40°C to (+)80°C. Mounting on - Din Rail, Degree of protection of enclosure - IP 20, Connection Cross Section (Flexiable) - 10sqmm-25sqmm., Available LED Indication for Healthy and Failure, Testing Standards/ Certifications - IEC 61643-11 with Transperant Enclosure in complete as per the direction of Engineer in charge.Make-Legrand/OBO/DEHN/Schneider/ABB/Siemens
2Supply of Surge protection Device (SPD) Clasee B+C, Type - 1+11 for handling Lightning surges of 10/350 s & Switching surges of 8/20 us waveform. Installed in DB and Sub DB. Technology (L-N)-MOV with built in thermal fuse, (N-PE)-Spark Gap Encapsulated/Non-exhausting, Maximum Continuous operating Voltage -320V per pole, Nominal Discharge Current In 30 kA (8/20 sec), Maximum Discharge Current Imax 40 kA (8/20 sec). Lightning Impulse Current 7 kA (10/350 sec)/pole 25 KA (10/350 sec) Total. Voltage protection level,Up <1.3 KV, Response time ta -(L-N) - 25ns (N-PE) <100 ns,Operating temperature range -(-)40°C to (+)80°C. Mounting on Din Rail, Degree of protection of enclosure - IP 20, Standards/ Certifications - IEC 61643-1 in complete as per the direction of Engineer in charge. .Model: V25 B+C- 3+NPE-320 with Transperant Enclosure.Make-Legrand/OBO/DEHN/Schneider/ABB/Siemens
3400 A MAIN Panel Board AT RDC GF/O/o SUPERINTENDENT GFS/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.60X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 400A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS(FROM EX TRANSFORMER)In commer-2-01 number of 400A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS (DG INCOMMER)01 no of 400A 4P onload changeover switch (MakeABB/Siemens/Schneider/Legrand)Busbar-1&2 04 numbers of 500Amps AL busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)Outgoing- 08 numbers of 125 A 4P Icu=100%Ics, 25 KA MCCB with adjustable TM based Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS) TO GF. Outgoing- 03 number of 250 A 4P Icu=100%Ics, 25 KA MCCB with adjustable TM based Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS) TO 1FInstrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data for all the incoming feeders2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND/ Siemens/ Schneider/ABB/OBO/DEHN )
4630 A MAIN Panel Board AT RDC GF/O/o SUPERINTENDENT GFS/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.60X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 630A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS(FROM EX TRANSFORMER)In commer-2-01 number of 630A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS (DG INCOMMER)01 no of 630A 4P onload changeover switch (MakeABB/Siemens/Schneider/Legrand)Busbar-1&2 04 numbers of 500Amps AL busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)Outgoing- 08 numbers of 125 A 4P Icu=100%Ics, 25 KA MCCB with adjustable TM based Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS) TO GF. Outgoing- 03 number of 400 A 4P Icu=100%Ics, 25 KA MCCB with adjustable TM based Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS) TO 1FInstrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data for all the incoming feeders2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND/ Siemens/ Schneider/ABB/OBO/DEHN )
5S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 250A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS(FROM EX TRANSFORMER)In commer-2-01 number of 250A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS (DG INCOMMER)In commer-2- 01 no of 250A 4P onload changeover switch (MakeABB/Siemens/Schneider/Legrand)Busbar-1&2 04 numbers of 300Amps AL busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Outgoing- 06 numbers of 125 A 4P Icu=100%Ics, 25 KA MCCB with adjustable TM based Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS)Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data for all the incoming feeders2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND/ Siemens/ Schneider/ABB/OBO/DEHN )
6Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 300 sq mm.
73.5Cx240 sqmm
83.5Cx185 sqmm
93.5Cx70 sqmm
103.5Cx50 sqmm
11100Amp TPN bus bar-300 X 32 X 3mm size
12S/F of 90W LED street light fitting (Make-Havels/Philips/Bajaj/ Crompton/Helonix)
13S/F of 200W LED flood light fitting (Make-Havells/Philips/C&S/Crompton)
14Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x300 sq mm
153.5 core x240sq mm
163.5 core x185sq mm
173.5 core x70 sq mm
18Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation, refilling the trench etc. as required but excluding sand cushioning and protective covering.
19Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, refilling the trench etc. as required but excluding sand cushioning and protective covering.
20Supplying and fixing 63Amps 4P 415 volts MCB, C Series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year.
21Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years..
22Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The RCCB should be Replacement Warranty will be 1 year
23Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit .(4X10+2X6)
24Supply ,installation ,testing & commissioning of 10-20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,240V, with built in BMS with IMD and Acoustic and Visual alaram system battery back up up to 30-45 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/ APC/ Vertiv)as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.
25Battery: 12v/26ah SMF batteries (Exide / Quanta/eq. make only) With Wide Range DC BUS facility, with Certification of IEC62040-1,2,3 Certification with CE/RoHS & PEP Compliance. SMF BATTER UP OF 60 MINUTES WITH DC CABLE 7 MTR, BREAKER, LINKS AND MS RACK FOR BATTERY HOUSING. with Two years warranty on both UPS & battery.
26Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit FRLS(Make-AKG/kinjol/Precision/Plasto/Polycab/Anchor/BEC/Norpack with fire proof) with 6Amp ,250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, G.I Metal box (Make-Schneider/ABB/Hager/Gliston/Legrand/Anchor) with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/Polycab/V-Guard/Anchor/KEI/RHINO/Glowstar) Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6Amp and 6Amp Modular switches connection ( Legrand mylinc/ Schneider clipsal/Hager insysta/Anchor Dura)
27Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand FRLSH copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Finolex/Polycab/Anchor/Havells/V-Guard/KEI/RHINO) 2 X 2.5sq.mm +1 X 1.5sqmm
282 X 4sq.mm +1 X 1.5sqmm.
29CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWERSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
30Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
31Supply and Fixing of PVC cable Trunk on Surface or Undergrounding Size 80mm(H) x 200mm(W) Heavy Duty MAKE- AKG/OBO/Neidax/Plasto/Precision UL specifications as required as per direction of Engg.-in-Charge.
32Supply and fixing copper plate earthing 600 mm X 600 mm X 3.15 mm thick ISI marked including accessories and providing masonary with charcoal and salt as required.
33Supply and laying of 25 mm x 5 mm copper strip on surface or in recess for connection etc as required.
34Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required
35Earthing Copper Busbar with insulator, Copper Lugs and nut bolt as required as per direction of Engineer-in-charge
36Foam type 5Ltrs, Fire extingusher
37Co2 4.5Kgs
38Dry Power 5KG
39Fire Bucket with Stand (4nos.in each stand)
40HT rubber mat (1Mtrx2mtr)
41Shock Treatment chart Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58341049
AUTHORITY Government Departments
TENDER VALUE 49.83 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Supply And Installation Of Electrical Life Safety Equipment Such As Supply Installation Testing and Commissioning of Electrical Protection System, Spd And Earthing Protection System To All Panel Board And Rccb And Rcbo To All Db Box And Upgradation Of Cable Laying Of Different Buildings Of Dhh, City Hospital At Berhampur In The District Of Ganjam.
Basic Detail
Tender No SE (R and B) Divn. I BAM No25/2026-27
Bidding Type Tender
Location
City Ganjam
State Odisha
Key Dates
Publish Date 02 Nov 2026
Submission Date 09 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 49.83 Lakhs
Tender Fee 6000
EMD 49900
Exemption Not Available
Document List
7d280098-1570-4ee7-bf9d-5bc93e0ed2b5.html
BOQ_617502.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

7d280098-1570-4ee7-bf9d-5bc93e0ed2b5.html

xls

BOQ_617502.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender