Coal and Mines Boards / Undertakings / PSU Closing in 0 days TDR #58340954

Tender For Drawing Of 6.6 Kv Overhead Line Up To Erection Yard (Excavation Department) From Dipka Unit Substation For Enabling The Assembling And Commissioning Of New Tata Hitachi Electric Hydraulic Shovel Along With Wiring Works At Erection Yard Und

Issued by Boards / Undertakings / PSU · Korba, Chhattisgarh
Tender Value
9.13 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
0 days left
EMD
11500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Korba → Chhattisgarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Drawing Of 6.6 Kv Overhead Line Up To Erection Yard (Excavation Department) From Dipka Unit Substation For Enabling The Assembling And Commissioning Of New Tata Hitachi Electric Hydraulic Shovel Along With Wiring Works At Erection Yard Under Power Supply, Gevra Project.

BOQ

Name of Work:- Drawing of 6.6 kV overhead line up to Erection Yard (Excavation Department) from Dipka Unit Substation for enabling the assembling and commissioning of new Tata Hitachi Electric Hydraulic Shovel along with wiring works at Erection Yard under Power Supply, Gevra Project.
Sl. No. Item Description
1Erection of Metallic pole 10.00 metre and upto 13.00 metre in cement concrete 0.3cmtr per pole, 1:3:6 (1 cement : 3 coarse sand : 6 graded stone) foundation including excavation and refilling etc. as required as per instruction of Engr. Inc.
2Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20mm X 600 mm ), 7/4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
3Stringing of line(Dog) all three conductor
4Supply and erection of 11KV/6.6 pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
5Supply and erection of 11/6.6KV disc insulator for 11/6.6 KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps ,bolt, nuts, washers etc.as required.
6Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 6.6/11/22/33 KV as required.
7Erection of double pole 3 wire cross arm for 6.6/11/22/33 KV over head lines as required.
8Stringing of line(Rabbit) Single conductor
9Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50cm outside the periphery of the area cleared.(Tree Trimming)
10Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick inclucding accessories and providing masonry enclosure with cover plate having locking arrangement watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
11Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
12Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required -Group A
13Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required- Group B
14Wiring for circuit/submain wiring alongwth earthwire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel/PVC conduit as required -.2*2.5sqmm + 1*2.5sqmm earth wire
15Wiring for circuit/submain wiring alongwth earthwire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel/PVC conduit as required. - 2*4sqmm + 1*4sqmm earth wire
16Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required -20mm
17Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required - 25mm
18Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required - 5/6 amps switch
19Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required - 6 pin 15/16A socket outlet
20Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required -15/16A switch
21Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required -3 pin 5/6 A socket outlet
22Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
23Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
24Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
25Laying of one number PVC insulated abd PVC sheathed/XLPE power cable of 1.1kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required. - Upto 35sqmm.
26Laying of one number PVC insulated abd PVC sheathed/XLPE power cable of 1.1kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required. - Above 35 sq. mm and upto 95sqmm
27Providing and fixing of following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel,making connections etc as required.Providing and fixing of 3pole MCCB 800A, 50kA
28Providing and fixing of following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel,making connections etc as required.Providing and fixing of 4pole MCCB 400A, 50kA
29Providing and fixing of TP switch 200amp(Rewirable type)
30Providing and fixing of LED tubelight fittings 20W with all accessories as required.
31Providing and fixing of Sunmica board 10X12
32Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Aeres in the existing MCB DB complete with connections, testing and commissioning etc. as required.63Amps RCCB 4Pole
33Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Providing and fixing of 12 way SPN double door MCB DB
34Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single Pole
35Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.(Fabrication and priming coat of Angle and Channel)(Angle and Channel will be provided by SECL)
36Providing and fixing bolts including nuts and washers complete.
37Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58340954
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 9.13 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name South Eastern Coalfields Limited
Work Description Tender for Drawing Of 6.6 Kv Overhead Line Up To Erection Yard (Excavation Department) From Dipka Unit Substation For Enabling The Assembling And Commissioning Of New Tata Hitachi Electric Hydraulic Shovel Along With Wiring Works At Erection Yard Under Power Supply, Gevra Project.
Basic Detail
Tender No SECL/GA/SO ENM/26-27/E-TENDER/80 dt. 02/11/2026
Bidding Type Tender
Location
City Korba
State Chhattisgarh
Key Dates
Publish Date 03 Nov 2026
Submission Date 16 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value 9.13 Lakhs
Tender Fee Ref. Documents
EMD 11500
Exemption Not Available
Document List
bbed7562-eb67-4645-b37c-8eb70b833bc2.html
BOQ_381037.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

bbed7562-eb67-4645-b37c-8eb70b833bc2.html

xls

BOQ_381037.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender