Tender For Drawing Of 6.6 Kv Overhead Line Up To Erection Yard (Excavation Department) From Dipka Unit Substation For Enabling The Assembling And Commissioning Of New Tata Hitachi Electric Hydraulic Shovel Along With Wiring Works At Erection Yard Und
Tender Overview
Project Description
Tender for Drawing Of 6.6 Kv Overhead Line Up To Erection Yard (Excavation Department) From Dipka Unit Substation For Enabling The Assembling And Commissioning Of New Tata Hitachi Electric Hydraulic Shovel Along With Wiring Works At Erection Yard Under Power Supply, Gevra Project.
BOQ
| Sl. No. | Item Description |
| 1 | Erection of Metallic pole 10.00 metre and upto 13.00 metre in cement concrete 0.3cmtr per pole, 1:3:6 (1 cement : 3 coarse sand : 6 graded stone) foundation including excavation and refilling etc. as required as per instruction of Engr. Inc. |
| 2 | Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20mm X 600 mm ), 7/4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 3 | Stringing of line(Dog) all three conductor |
| 4 | Supply and erection of 11KV/6.6 pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 5 | Supply and erection of 11/6.6KV disc insulator for 11/6.6 KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps ,bolt, nuts, washers etc.as required. |
| 6 | Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 6.6/11/22/33 KV as required. |
| 7 | Erection of double pole 3 wire cross arm for 6.6/11/22/33 KV over head lines as required. |
| 8 | Stringing of line(Rabbit) Single conductor |
| 9 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50cm outside the periphery of the area cleared.(Tree Trimming) |
| 10 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick inclucding accessories and providing masonry enclosure with cover plate having locking arrangement watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 11 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 12 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required -Group A |
| 13 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required- Group B |
| 14 | Wiring for circuit/submain wiring alongwth earthwire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel/PVC conduit as required -.2*2.5sqmm + 1*2.5sqmm earth wire |
| 15 | Wiring for circuit/submain wiring alongwth earthwire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel/PVC conduit as required. - 2*4sqmm + 1*4sqmm earth wire |
| 16 | Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required -20mm |
| 17 | Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required - 25mm |
| 18 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required - 5/6 amps switch |
| 19 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required - 6 pin 15/16A socket outlet |
| 20 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required -15/16A switch |
| 21 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required -3 pin 5/6 A socket outlet |
| 22 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 23 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 24 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 25 | Laying of one number PVC insulated abd PVC sheathed/XLPE power cable of 1.1kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required. - Upto 35sqmm. |
| 26 | Laying of one number PVC insulated abd PVC sheathed/XLPE power cable of 1.1kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench as required. - Above 35 sq. mm and upto 95sqmm |
| 27 | Providing and fixing of following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel,making connections etc as required.Providing and fixing of 3pole MCCB 800A, 50kA |
| 28 | Providing and fixing of following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel,making connections etc as required.Providing and fixing of 4pole MCCB 400A, 50kA |
| 29 | Providing and fixing of TP switch 200amp(Rewirable type) |
| 30 | Providing and fixing of LED tubelight fittings 20W with all accessories as required. |
| 31 | Providing and fixing of Sunmica board 10X12 |
| 32 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Aeres in the existing MCB DB complete with connections, testing and commissioning etc. as required.63Amps RCCB 4Pole |
| 33 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Providing and fixing of 12 way SPN double door MCB DB |
| 34 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single Pole |
| 35 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.(Fabrication and priming coat of Angle and Channel)(Angle and Channel will be provided by SECL) |
| 36 | Providing and fixing bolts including nuts and washers complete. |
| 37 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender