Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #58340116

Tender For Repair, Maintenance, Replacement Of Security Lights, Street Lights, Flood Lights, Timer Panels, Perimeter Lights, High Mast Tower And Connected Items At Tech Area At Af Stn Naliya

Issued by Statutory Bodies & Commissions/Committees · Kachchh, Gujarat
Tender Value
25 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
3 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair, Maintenance, Replacement Of Security Lights, Street Lights, Flood Lights, Timer Panels, Perimeter Lights, High Mast Tower And Connected Items At Tech Area At Af Stn Naliya

BOQ

Name of Work:- REPAIR, MAINTENANCE, REPLACEMENT OF SECURITY LIGHTS, STREET LIGHTS, FLOOD LIGHTS, TIMER PANELS, PERIMETER LIGHTS, HIGH MAST TOWER AND CONNECTED ITEMS AT TECH AREA AT AF STN NALIYA
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/ loose soil, for laying of under ground electric cable complete all as specified and directed.
2Taking out LT UG cables of any size by excavation and earth work in any type of soil, removing bricks or PCC cover of any size complete all as specified and directedNote:- Excavation, Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separately.
3Relaying old serviceable under ground LT cable of any size obtained from serial item number 2.00 above complete all as specified and directed.
4Supply, laying, jointing and testing in repairs/replacement of LT cable XLPE insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100V grade, of size 04 Sqmm 2 core with proper size of lugs and laid in trenches / ducts / through GI pipe / fixed to poles etc complete all as specified and directed. Note:- Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately under respective item of this Schedule.
5All as per serial item number 4.00 here-in-before but of size 16 Sqmm 4 core
6Material and labour for river bed sand used in trenches/ ducts 08 cm under cable and 15 cm above the cable for cushioning/protection to cable and get thick 18cm after hand punning complete all as specified and directed
7Laying only serviceable un-reinforced precast concrete cable cover class LV, Type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over for cable protection complete all as specified and directed.
8Supply and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over for cable protection complete all as specified and directed.
9Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed
10Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
11Supply, fixing and testing LT cable jointing kit straight through type heat shrinkable suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100 volts grade LT cable of size 3.5/4 core 16 to 50 sqmm and including taking out cable from faulty portion in any situation/position complete all as specified and directed.
12All as per serial item number 11.00 here-in-before but size 3.5 core 70 sqmm to 150 sqmm .
13Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads in drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, pipes of 40 mm bore , fixed in repair complete all as specified and as directed.
14All as per serial item number 13.00 here-in-before but of size 50 mm.
15Dismantling / taking down in repairs the street light / security lights of any capacity & description from existing LT pole/walls at any height and refixing the fittings in existing / another location after repair work (replacement of defective parts, checking for loose connections etc) complete all as specified and as directed.Note:- (i) Replacement of defective parts / accessories shall be measured and paid separately under relevant items. (ii) Transport and T & P i.e. Ladder, safety items,lugs,insulation tape, GI screws, nut bolts etc. or any other equipment for repair of street light shall be provided by Contractor and cost for the same deemed to be include in respective items.(iii) Contractor shall submit job card for each repairs/maintenace under this item to concern JE (Printed Job card shall be provied by the contractor as per format given by Engineer-in-Charge). Charges for printing job card shall be inclusive in the item rate.
16Supply and fix in repairs, brackets for street light fitting made out of 32 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to pole with suitable size of M.S. clamps made of M.S flat of size 40 mm x 3 mm, 2 Nos, M.S nut & bolt with cup washers and dismantling old rusted/unserviceable bracket with its rusted clamps and nut bolts complete all as specified and directed. Note :- Rate of GI Pipe, clamps, flat and nut bolts inclusive in the item rate.
17Supply and fix in repairs, flexible PVC insulated multicore FR PVC sheathed multistranded copper conductor cable of 1.0 Sqmm x 3 core for voltage grade up to 1100 V conforming to IS 694 : 2010 for connection of light fitting from junction box or from over head conductors to fitting complete all as specified and directed. Note :- PVC Conduit shall be measuerd and paid seperately under respective item.
18Supply and fix in repairs, service wire 1100 volts grade PVC insulated PVC sheathed cable weather proof multi stranded with aluminum conductor of size 2 core 4.0 sqmm complete all as specified and directed.
19Material and labour for cutting under road/PCC path and passing GI pipe for cable protection and making good as existing complete all as specified and as directed.
20Supply and fix in repairs, LED street light fitting 60/70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
21Supply and fix in repairs, LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
22Supply and fix in repairs, LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
23Supply and fix in repairs, LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
24Supply and fix in repairs, LED Aviation light at overhead tank/Signal tower/Telephone tower or any high rise buildings at any location of Red colour, 230V AC complete all as specified and directed.
25Supply and fix in repairs/replacement of auto /manual street light timer nature switch weather proof IP 54 protection enclosure made out of UV stabilized, FR grade special molding compound, rust proof, electric sock proof, vermin proof outdoor pole mountable with mounting bracket made out of GI and nut, bolts, washers including cable glands, openable door with 05 kW single phase load with Power contactors rating 25 Amps 01 nos as incoming and outgoing with MCB rating of 32 Amps/phase and circuit wiring of min 6 sqmm including taking down existing switch complete all as specified and directed. Note :- Rate of GI clamps, nut bolts inclusive in the item rate.
26Supply and fix in repairs/replacement of auto /manual street light timer nature switch weather proof IP 54 protection enclosure made out of UV stabilized, FR grade special molding compound, rust proof, electric sock proof, vermin proof outdoor pole mountable with mounting bracket made out of GI and nut, bolts, washers including cable glands, openable door with 08 kW three phase load with Power contactors rating 25 Amps 3 nos as incoming and outgoing with MCB rating of 32 Amps/phase and circuit wiring of min 16 sqmm including taking down existing switch complete all as specified and directed. Note :- Rate of GI clamps, nut bolts inclusive in the item rate.
27Supply and fix in repairs/replacement for kiosk box for luminaries, weather proof made out of PVC/HDPE /FRP housing fire retardant, non fusing, shock & rust proof, single piece molded and cover with hinged door, pole mounting type comprising of aluminum TPN bus bar of 20 Amps of minimum size 333x233x120mm, fixed on pole with MS, clamps 30x5mm with necessary nuts, washer including MCB 16 Amps for out going complete all as specified and directed. Note :- Rate of TPN bus bar and MS clamp inclusive in the item rate.
28All as per serial item number 27.00 here-in-before but of size 450 x 375 x 200 mm.
29Supply and fix in repairs, LED driver 45/50W 1500mA suitable for LED light fitting complete all as specified and dircted.
30Supply and fix in repairs, LED driver 75W/80W 2600mA suitable for LED light fitting complete all as specified and dircted.
31Supply and fix in repairs, LED driver 100W,2600mA suitable for LED light fitting complete all as specified and dircted.
32Supply and fix in repairs, LED driver 150/240W3000mA suitable for 240 watt LED light fitting complete all as specified and dircted.
33Material and labour for maintenance/repair of highmast light of height upto 16 mtr. after safely lowering down head frame lantern carriage accomodating flood lights. Greasing and adequate tightening of all movable parts of base section i.e motor chain, sprockets, shaft of 3 phase elect wintch motor, steel wire rope after removing all rust/stain over surface of equipments by stain remover. Checking all electrical connections of feeder pillar box and replacing defective flood lights, drivers, switchgears, lugs etc before liftinglantern carriage frame assembly in its initial position complete all as specified and directed.Note:- (i) Replacement of defective flood lights/drivers shall be measured and paid separately under relevant items. (ii) Transport and T & P i.e. Ladder, safety items, or any other equipment for repair of high mast light shall be provided by Contractor and cost for the same to be incl in job itself. (iii) Contractor will ensure that periodical check to be done for making good all defects by replacing nuts/bolts/PVC connection etc and keep the light fitting in working condition through out the period of contract.
34Trimming of tree branches touching to over head lines, up to 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearance of HT/LT pole and sub station premises complete all as specified and directed. Note:- (i) Trimming of all branches of trees falling under one span between two pole shall be considered as one span only. (ii) Contractor have to arrange all T&P, safety equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishappening occurred due to negligence of safety aspects.
35Restretching/ tightening of ACSR conductor of any type and size by disconnecting from insulators from any location complete all as specified and directed.Note:- (i) Proper shut down has to be taken from MES. (ii) T & P i.e. Ladder, safety items, or any other equipment for repair tightening of ACSR conductor shall be provided by Contractor and cost for the same deemed to be included in respective items.
36Supply and fix in repairs, pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 volts grade complete all as specified and drected.
37Supply and fix in repairs, shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, 1100 volt grade of size 75 mm height and 90mm dia complete all as specified and directed.
38S&F in replacement, Contactor Triple Pole 18 Amps, 415 V ,9.0 kW cat part CE15D1 or equivalent for street light Auto Timers complete all as specified and directed.
39Supply and fix in replacement, MCB Triple Pole and Neutral 40/63 Amps, 415 V ,10KA B curve breaking capacity complete all as specified and directed.
40Supply and fix in replacement, MCB Single Pole 6 to 32 Amps, 240 V ,10KA B curve breaking capacity complete all as specified and directed. Please Enable Macros to View BoQ information
41Supply and fix in replacement, MCB Single Pole 6 to 32 Amps, 240 V ,10KA B curve breaking capacity complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58340116
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 23-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair, Maintenance, Replacement Of Security Lights, Street Lights, Flood Lights, Timer Panels, Perimeter Lights, High Mast Tower And Connected Items At Tech Area At Af Stn Naliya
Basic Detail
Tender No 8242/E8
Bidding Type Tender
Location
City Kachchh
State Gujarat
Key Dates
Publish Date 03 Nov 2026
Submission Date 23 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
11e1ec92-d680-47ba-9600-f071c09b51c3.html
BOQ_893969.xls
Tender8242.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

11e1ec92-d680-47ba-9600-f071c09b51c3.html

xls

BOQ_893969.xls

pdf

Tender8242.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender