Tender For Replacement Of Unserviceable Dbs Meter Panel Boards And Connected Works At Omqs And Smqs At Af Stn Tezpur
Tender Value
38.83 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
0 days left
EMD
77669
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Unserviceable Dbs Meter Panel Boards And Connected Works At Omqs And Smqs At Af Stn Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/ aluminium point wiring (light/fan/bell/ holder/socket or power point) complete inclusive of all fittings such as switches, ceiling roses, pendants, regulators, sockets, fittings etc. removing materials from site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed. |
| 2 | Taking down carefully aluminium sub main wiring of any type and size including fittings and fixtures, removing materials from site complete all as directed. |
| 3 | Disconnecting from electric circuit and taking out existing unserviceable MCB DB SPN of any number of ways including MCB etc removing materials from site complete all as specified. |
| 4 | Disconnecting from electric circuit and taking out electric meter from the existing sheet metal enclosure and deposited to MES for re-fixing complete all as specified. |
| 5 | Materials and labour for concealed point wiring with 1.5 Sqmm PVC insulated and unsheathed multistranded FRLSH copper conductor cable 1100 volts grade, single core, drawn through and including PVC concealed conduit (medium grade) not less than 20mm size complete with all fittings and accessories suitable for one light / one fan/ bell pint controlled by one switch including unsheathed single core stranded copper cable of size 1.5 Sqmm as earth continuity conductor connected to common earth and earty dolly and to be terminated to sunken/pressed flush box readily available covered with outer plates/inner plates etc as per site requirement and making good disturbed surfaces of walls,floors etc complete all as specified and as directed. Note:- 1. Metal box /modular plate/switches shall be measured and paid separaely including testing on completeion complete all as specified and as directed. |
| 6 | Materials and labour for concealed point wiring with 1.5 Sqmm PVC insulated and unsheathed multistranded FRLSH copper conductor cable 1100 volts grade, single core, drawn through and including PVC concealed conduit (medium grade) not less than 20mm size complete with all fittings and accessories suitable for one light controlled by two way switch including unsheathed single core stranded copper cable of size 1.5 Sqmm as earth continuity conductor connected to common earth and earty dolly and to be terminated to sunken/pressed flush box readily available covered with outer plates/inner plates etc as per site requirement and making good disturbed surfaces of walls,floors etc complete all as specified and as directed. Note:- 1. Metal box /modular plate/switches shall be measured and paid separaely including testing on completeion complete all as specified and as directed. |
| 7 | Supply and fixing for modular switch 6 Amps, 230 V, single pole, one way, 1 module complete all as specified and as directed |
| 8 | Supply and fixing for modular 2 way switch 6 Amps, 230 V, single pole, one way, 1 module complete all as specified and as directed |
| 9 | Supply and fixing for modular bell push 6 Amps 230V, single pole, one way, 1 module complete all as specified and as directed. |
| 10 | Supply and fixing for bell ding dong type AC 230 V, single pole complete all as specified and as directed. |
| 11 | Material and labour ceiling rose, surface bakelite, 65mm x 50mm three terminals complete all as specified and as directed. |
| 12 | Supply only modular metal flush box of 02/01 module complete all as specified and as directed. |
| 13 | Supply and fixing for modular cover plate with frame 02/01 module complete all as specified and as directed |
| 14 | Material and labour two single core PVC insulated unsheathed cable 6.0 sqmm (Nominal area) two run with multistranded copper conductor cable, 1100 volts grade, drawn through and including PVC concealled conduit with accessories and continious earth wire of single core PVC insulated, unsheathed cable 6.00 sqmm (Nominal area) with ultistranded copper conductor (green)one run 1100 volts grade for sub main wiring and making good disturbed surfaces complete all as specified and as directed. Note:- (i) Two run of wiring cable, one run of earth wire shall be measured as one unit. |
| 15 | Material and labour two single core PVC insulated unsheathed cable 10.0 sqmm (Nominal area) two run with multistranded copper conductor cable, 1100 volts grade, drawn through and including PVC concealled conduit with accessories and continious earth wire of single core PVC insulated, unsheathed cable 10 sqmm (Nominal area) with ultistranded copper conductor (green)one run 1100 volts grade for sub main wiring and making good disturbed surfaces complete all as specified and as directed. Note:- (i) Two run of wiring cable, one run of earth wire shall be measured as one unit. |
| 16 | Taking down and M&L sub main wiring with four single core PVC insulated unsheathed cable 6.00 Sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade drawn through and including PVC conduit of size not less than 25mm with accessories and earth continuity conductor of two single core PVC insulated, unsheathed cable 6.00 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade and making good disturbed surfaces complete all as specified and directed. Note - (i) Four run of wiring cable, two run of earth wire and one run of PVC Conduit shall be measured as one unit. |
| 17 | Taking down and M&L sub main wiring with four single core PVC insulated unsheathed cable 10.00 Sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade drawn through and including PVC conduit of size not less than 25mm with accessories and earth continuity conductor of two single core PVC insulated, unsheathed cable 10.00 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade and making good disturbed surfaces complete all as specified and directed. Note - (i) Four run of wiring cable, two run of earth wire and one run of PVC Conduit shall be measured as one unit. |
| 18 | Supply & fix 10 W surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of pressure die casting housing with acrylic diffuser high brightness LEDs complete all as specified and as directed. |
| 19 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket including GI Pipe light grade 32/40mm dia adjustable bend 1.5mtr and impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 20 | S&F sheet metal enclosures MCB DB 8 way SPN, Vertical type , double door, IP54 Protection with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies complete all as specified and directed. |
| 21 | Supply and fix Miniature circuit breaker (MCBs) Single Pole, 240 Volts, 10KA, 6 to 32 Amps, 'C' curve complete all as specified and directed. |
| 22 | Supply and fix MCB SPN 6 to 32 Amps 10KA ‘C’ series 240 volts complete all as specified and as directed. |
| 23 | Fixing only and connecting electric meters upto 25 amps obtained from BOQ item No 4.00 complete all as specified and directed. |
| 24 | Taking down carefully the existing unserviceable energy meter of any size and making good the disturbed surfaces of walls, Supply and fixing energy meter enclosure of size 110cm x 85 cm x 24 cm fabricated out of 2mm thick MS sheet front openable with lock and key arrangement including weather, dust and vermin proof suitable for fixing single phase electric energy meter-8 Nos and fixed over the wall with necessary grouting arrangement and refixing electric meters/circuits as per site condition including one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 25 | S&F sheet metal enclosures MCCB DB 4 way VTPN, double door, vertical type, with 200 Amp rated bus bar including earth & neutral link, IP 43 protection, complete fixing accessories and taking out existing unserviceable cutout any type etc any number of ways including MCB etc and making good disturbed surfaces of floors/walls/ceiling etc. complete all as specified and directed. |
| 26 | Taking down old change over switch/cutout and S&F Moulded case circuit breaker (MCCBs) Triple pole and Nuetral, 415 Volts, adjustable type 100 Amps, 16KA with current carrying capacity in the DB complete all as specified and directed. |
| 27 | M & L for earthing complete with galvanized steel earth plate electrode 600mmx600mmx6mm thick buried directly in gournd (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized 4 mm dia earth wire as earthing lead upto 7.5 mtrs from testing point fixed by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 25mm bore medium grade galvanised iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore light grade galvanised iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (Compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1 50mm thick precast RCC M-20 nominal mix cover slab of size 450mm x 450mm reinforced with 8mm dia TMT bar 10 cm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in soft / loose soil and deposited soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No. 3 of MES shedule of SSR Part-I complete all as specified and as directed. |
| 28 | Supply and fix GI wire dia 4 mm size complete all as specified and as directed. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026